Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq. bras. cardiol ; 113(1 supl.2): 47-47, jul., 2019.
Artigo em Português | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1015790

RESUMO

INTRODUÇÃO: É inegável que o uso de oxigenação por membrana extracorpórea (ECMO) nos pacientes admitidos em centros de terapia intensiva cardiopediátrica, especialmente para suporte no pós-operatório de cardiopatias congênitas complexas, impactou drasticamente no manejo e prognóstico de crianças cardiopatas. OBJETIVO: Descrever os resultados e avanços no uso de ECMO em instituição de referência para crianças cardiopatas. MÉTODOS: Análise retrospectiva de perfil, diagnóstico, indicação, duração, desmame, complicações e sobrevida dos pacientes que usaram suporte extracorpóreo. RESULTADOS: 42 pacientes foram submetidos à ECMO no período de janeiro de 2013 a maio de 2018, a maioria do sexo masculino (64%), com até dois anos de idade (66,6%) e peso inferior a 10 Kg (66,6%). Em relação ao diagnóstico inicial, apenas três casos se tratavam de cardiopatias adquiridas (miocardiopatia) e os demais (92,8%) de cardiopatias congênitas complexas, sendo mais frequente a Transposição das Grandes Artérias (16,6%). A principal indicação para a instalação do suporte circulatório foi a falência ventricular esquerda e/ou direita no pós-operatório imediato (64,2%). Em todos, utilizou-se canulação venoarterial. A duração da ECMO variou de 1 hora a 34 dias, sendo superior a uma semana em 38,1% dos casos. As complicações mais observadas foram politransfusão (100%), plaquetopenia (100%), injúria renal aguda dialítica (80,9%) e sangramento com revisão da hemostasia (76,1%). No que diz respeito ao desfecho da ECMO, o desmame ocorreu com sucesso em 24 pacientes (57,1%), resultando em 14 altas hospitalares (33,3%). Entre os óbitos, incluem-se todos os quatro pacientes com fisiologia univentricular. Destacam-se evoluções notadamente mais favoráveis após os dois anos iniciais de uso dessa tecnologia. A causa do óbito se deu majoritariamente em decorrência de choque cardiogênico por falência ventricular não recuperada e/ou por fatores diretamente relacionados à assistência extracorpórea. CONCLUSÃO: ECMO configura-se em uma opção terapêutica revelante e complexa no manejo das crianças cardiopatas, que exige treinamento e investimento constantes para obtenção de resultados minimamente aceitáveis. Diante disso, como já relatado na literatura especializada, após a curva de aprendizado inicial da equipe, notou-se melhora progressiva na indicação, na condução e no desmame desse suporte, permitindo índices de sobrevida mais satisfatórios e consistentes, que justificam a sua utilização. (AU)


Assuntos
Humanos , Oxigenação por Membrana Extracorpórea , Cardiopatias Congênitas
2.
Int J Cardiovasc Imaging ; 32(5): 729-39, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26723574

RESUMO

Stenting for CoA has become an acceptable treatment modality in the last 20 years. However little is known about arterial changes after this procedure. To assess arterial structure and function including peripheral reactivity and stiffness and intima-media thickness (IMT) pre and post stenting for coarctation of the aorta (CoA). Twenty-one patients [median age: 15 years (8-39)] were studied at baseline, 1 day, 6 months and 1 year after stenting. Twenty-one healthy subjects (1:1 matched) were used as controls. Left ventricular (LV) mass, ejection fraction, flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of left brachial artery, common carotid (CC) and right subclavian artery (RSCA) IMT and pulse wave velocity (PWV) were assessed by echocardiography and vascular ultrasound. CoA patients had higher LV indexed mass (p < 0.0001), impaired FMD (p < 0.0001) and NMD (p < 0.0001), increased PWV (p < 0.0001), carotid and RSCA IMT (both p < 0.0001). All procedures were successful and resulted in significant gradient reduction (p < 0.001). One year after stenting there was improvement in LV function (p = 0.034) and although there was significant reduction of LV mass (103.29 ± 24.77 vs. 74.39 ± 22.07 g/m(2), p < 0.0001) values did not normalize. There was no significant change in FMD, NMD, PWV and CC or RSCA IMT. In patients with CoA, arterial reactivity is impaired and LV mass, arterial stiffness and thickness are increased. Although stenting is successful to relieve the obstruction resulting in better LV function and mass reduction, arterial structure and function remains abnormal after 1 year of follow-up.


Assuntos
Coartação Aórtica/terapia , Artéria Braquial , Artérias Carótidas , Procedimentos Endovasculares/instrumentação , Stents , Artéria Subclávia , Adolescente , Adulto , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Aortografia/métodos , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiopatologia , Brasil , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Espessura Intima-Media Carotídea , Criança , Angiografia por Tomografia Computadorizada , Ecocardiografia , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Análise de Onda de Pulso , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Volume Sistólico , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler , Remodelação Vascular , Rigidez Vascular , Vasodilatação , Função Ventricular Esquerda , Adulto Jovem
3.
Int J Cardiovasc Imaging ; 32(5): 729-739, 2016.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063481

RESUMO

Stenting for CoA has become an acceptable treatment modality in the last 20 years. However little is known about arterial changes after this procedure. To assess arterial structure and function including peripheral reactivity and stiffness and intima-media thickness (IMT) pre and post stenting for coarctation of the aorta (CoA). Twenty-one patients [median age: 15 years (8-39)] were studied at baseline, 1 day, 6 months and 1 year after stenting. Twenty-one healthy subjects (1:1 matched) were used as controls. Left ventricular (LV) mass, ejection fraction, flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of left brachial artery, common carotid (CC) and right subclavian artery (RSCA) IMT and pulse wave velocity (PWV) were assessed by echocardiography and vascular ultrasound. CoA patients had higher LV indexed mass (p < 0.0001), impaired FMD (p < 0.0001) and NMD (p < 0.0001), increased PWV (p < 0.0001), carotid and RSCA IMT (both p < 0.0001). All procedures were successful and resulted in significant gradient reduction (p < 0.001). One year after stenting there was improvement in LV function (p = 0.034) and although there was significant reduction of LV mass (103.29 ± 24.77 vs...


Assuntos
Espessura Intima-Media Carotídea , Stents , Vasodilatação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...