Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Inflamm Bowel Dis ; 28(10): 1614-1617, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-35348692

RESUMO

Patients with MS and IBD were as likely to have stricturing, fistulizing, and extensive IBD as IBD controls. Although MS-IBD patients were less likely to initiate anti-TNF therapy, they did not have worsened risk of progression to surgery on follow-up.


Assuntos
Doenças Inflamatórias Intestinais , Esclerose Múltipla , Humanos , Doenças Inflamatórias Intestinais/complicações , Infliximab , Esclerose Múltipla/complicações , Esclerose Múltipla/epidemiologia , Estudos Retrospectivos , Fator de Necrose Tumoral alfa
2.
Proc (Bayl Univ Med Cent) ; 31(3): 324-325, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29904299

RESUMO

Acute pancreatitis is an inflammatory condition of the pancreas manifesting with abdominal pain and elevated serum levels of pancreatic enzymes. Gallstones and chronic alcohol use are the most commonly described causes. A less studied cause is cholesterolosis, gallbladder polyps that cause mechanical obstruction of the sphincter of Oddi. Here, we present the case of a 55-year-old woman who presented with acute pancreatitis and was found to have cholesterol polyps in her gallbladder with no evidence of gallstones. The patient underwent cholecystectomy with complete resolution of her symptoms.

3.
J Appl Clin Med Phys ; 18(3): 37-43, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28407345

RESUMO

PURPOSE: In SBRT for prostate cancer, higher fractional dose to the rectum is a major toxicity concern due to using smaller PTV margin and hypofractionation. We investigate the dosimetric impact on rectum using endorectal balloon (ERB) in prostate SBRT. MATERIALS AND METHODS: Twenty prostate cancer patients were included in a retrospective study, ten with ERB and 10 without ERB. Optimized SBRT plans were generated on CyberKnife MultiPlan for 5 × 7.25 Gy to PTV under RTOG-0938 protocol for early-stage prostate cancer. For the rectum and the anterior half rectum, mean dose and percentage of volumes receiving 50%, 80%, 90%, and 100% prescription dose were compared. RESULTS: Using ERB, mean dose to the rectum was 62 cGy (P = 0.001) lower per fraction, and 50 cGy (P = 0.024) lower per fraction for the anterior half rectum. The average V50% , V80% , V90% , and V100% were lower by 9.9% (P = 0.001), 5.3% (P = 0.0002), 3.4% (P = 0.0002), and 1.2% (P = 0.005) for the rectum, and lower by 10.4% (P = 0.009), 8.3% (P = 0.0004), 5.4% (P = 0.0003), and 2.1% (P = 0.003) for the anterior half rectum. CONCLUSIONS: Significant reductions of dose to the rectum using ERB were observed. This may lead to improvement of the rectal toxicity profiles in prostate SBRT.


Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Reto/efeitos da radiação , Humanos , Masculino , Neoplasias da Próstata/patologia , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiometria , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...