Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Soc Nephrol ; 32(12): 3208-3220, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34588184

RESUMO

BACKGROUND: Preliminary evidence suggests patients on hemodialysis have a blunted early serological response to SARS-CoV-2 vaccination. Optimizing the vaccination strategy in this population requires a thorough understanding of predictors and dynamics of humoral and cellular immune responses to different SARS-CoV-2 vaccines. METHODS: This prospective multicenter study of 543 patients on hemodialysis and 75 healthy volunteers evaluated the immune responses at 4 or 5 weeks and 8 or 9 weeks after administration of the BNT162b2 or mRNA-1273 vaccine, respectively. We assessed anti-SARS-CoV-2 spike antibodies and T cell responses by IFN-γ secretion of peripheral blood lymphocytes upon SARS-CoV-2 glycoprotein stimulation (QuantiFERON assay) and evaluated potential predictors of the responses. RESULTS: Compared with healthy volunteers, patients on hemodialysis had an incomplete, delayed humoral immune response and a blunted cellular immune response. Geometric mean antibody titers at both time points were significantly greater in patients vaccinated with mRNA-1273 versus BNT162b2, and a larger proportion of them achieved the threshold of 4160 AU/ml, corresponding with high neutralizing antibody titers in vitro (53.6% versus 31.8% at 8 or 9 weeks, P <0.0001). Patients vaccinated with mRNA-1273 versus BNT162b2 exhibited significantly greater median QuantiFERON responses at both time points, and a larger proportion achieved the threshold of 0.15 IU/ml (64.4% versus 46.9% at 8 or 9 weeks, P <0.0001). Multivariate analysis identified COVID-19 experience, vaccine type, use of immunosuppressive drugs, serum albumin, lymphocyte count, hepatitis B vaccine nonresponder status, and dialysis vintage as independent predictors of the humoral and cellular responses. CONCLUSIONS: The mRNA-1273 vaccine's greater immunogenicity may be related to its higher mRNA dose. This suggests a high-dose vaccine might improve the impaired immune response to SARS-CoV-2 vaccination in patients on hemodialysis.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Humanos , Vacina BNT162 , Vacina de mRNA-1273 contra 2019-nCoV , Estudos Prospectivos , COVID-19/prevenção & controle , SARS-CoV-2 , Anticorpos Antivirais , Imunidade Celular
2.
Clin Immunol ; 142(3): 252-68, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22177848

RESUMO

In a phase I/IIa clinical trial, 17 HIV-1 infected patients, stable on cART, received 4 vaccinations with autologous dendritic cells electroporated with mRNA encoding Tat, Rev and Nef, after which cART was interrupted. Vaccination was safe and feasible. During the analytical treatment interruption (ATI), no serious adverse events were observed. Ninety-six weeks following ATI, 6/17 patients remained off therapy. Although induced and/or enhanced CD4(+) and CD8(+) T-cell responses specific for the immunogens were observed in most of the patients, we found no correlation with the number of weeks off cART. Moreover, CD4(+) T-cell counts, plasma viral load and the time remaining off cART following ATI did not differ from historical control data. To conclude, the vaccine was safe, well tolerated and resulted in vaccine-specific immune responses. Since no correlation with clinical parameters could be found, these results warrant further research in order to optimize the efficacy of vaccine-induced T-cell responses.


Assuntos
Vacinas contra a AIDS/imunologia , Células Dendríticas/imunologia , Infecções por HIV/terapia , HIV-1/imunologia , Imunização , Adulto , Idoso , Células Cultivadas , Produtos do Gene rev/imunologia , Produtos do Gene tat/imunologia , Infecções por HIV/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Produtos do Gene nef do Vírus da Imunodeficiência Humana/imunologia
3.
Blood Coagul Fibrinolysis ; 17(2): 155-60, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16479199

RESUMO

The factor V-corrected activated protein C resistance assay is the test of choice to screen for the factor V Leiden mutation. During the past 2 years, local test results with the frequently used Coatest APCR kit were evaluated and compared with the results of DNA analysis, the 'gold standard'. Samples of 278 patients were analysed by both techniques. We were unable to confirm that factor V Leiden carriers can clearly be delineated from normal individuals with the Coatest APCR test. A ratio of 2.0 as the cut-off provides 99.0% sensitivity and 95.4% specificity.To evaluate the lupus anticoagulant interference, we retrospectively analysed 16 lupus anticoagulant-positive patients. In this study, two (12.5%) showed a false-positive activated protein C resistance result. Six out of 16 (37.5%) lupus anticoagulant-positive patients were also carriers of the factor V Leiden mutation. Four out of eight (50%) false-positive activated protein C resistance results presented with an abnormal baseline clotting time. In order to prevent reporting false-positive results, a maximum baseline clotting time (65.8 s) was calculated. A new scheme for interpreting activated protein C resistance ratios was proposed.


Assuntos
Resistência à Proteína C Ativada/sangue , Fator V/análise , Inibidor de Coagulação do Lúpus/sangue , Tempo de Tromboplastina Parcial , Resistência à Proteína C Ativada/genética , Análise Mutacional de DNA/métodos , Fator V/genética , Reações Falso-Positivas , Feminino , Humanos , Inibidor de Coagulação do Lúpus/genética , Masculino , Programas de Rastreamento/métodos , Tempo de Tromboplastina Parcial/métodos , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...