Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microsc ; 270(2): 150-155, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29323420

RESUMO

Some implementations of interference microscopy imaging use digital holographic measurements of complex scattered fields to reconstruct three-dimensional refractive index maps of weakly scattering, semi-transparent objects, frequently encountered in biological investigations. Reconstruction occurs through application of the object scattering potential which assumes an isotropic refractive index throughout the object. Here, we demonstrate that this assumption can in some circumstances be invalid for biological imaging due to the presence of lipid-induced optical anisotropy. We show that the nanoscale organization of lipids in the observation of cellular endocytosis with polarized light induces a significant change in far-field scattering. We obtain this result by presenting a general solution to Maxwell's equations describing light scattering of core-shell particles near an isotropic substrate covered with an anisotropic thin film. This solution is based on an extension of the Bobbert-Vlieger solution for particle scattering near a substrate delivering an exact solution to the scattering problem in the near field as well as far field. By applying this solution to study light scattering by a lipid vesicle near a lipid bilayer, whereby the lipids are represented through a biaxial optical model, we conclude through ellipsometry concepts that effective amounts of lipid-induced optical anisotropy significantly alter far-field optical scattering in respect to an equivalent optical model that neglects the presence of optical anisotropy.


Assuntos
Anisotropia , Endocitose , Exocitose , Imageamento Tridimensional/métodos , Microscopia de Interferência/métodos , Lipídeos
2.
Rev Sci Instrum ; 78(12): 123101, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18163714

RESUMO

The autofluorescence of biological tissue can be exploited for the detection and diagnosis of disease but, to date, its complex nature and relatively weak signal levels have impeded its widespread application in biology and medicine. We present here a portable instrument designed for the in situ simultaneous measurement of autofluorescence emission spectra and temporal decay profiles, permitting the analysis of complex fluorescence signals. This hyperspectral fluorescence lifetime probe utilizes two ultrafast lasers operating at 355 and 440 nm that can excite autofluorescence from many different biomolecules present in skin tissue including keratin, collagen, nicotinamide adenine dinucleotide (phosphate), and flavins. The instrument incorporates an optical fiber probe to provide sample illumination and fluorescence collection over a millimeter-sized area. We present a description of the system, including spectral and temporal characterizations, and report the preliminary application of this instrument to a study of recently resected (<2 h) ex vivo skin lesions, illustrating its potential for skin cancer detection and diagnosis.


Assuntos
Biomarcadores Tumorais/análise , Medições Luminescentes/instrumentação , Neoplasias Cutâneas/diagnóstico , Espectrometria de Fluorescência/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Técnicas de Sonda Molecular , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
3.
Opt Express ; 15(20): 12548-61, 2007 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19550524

RESUMO

We report a multifocal multiphoton time-correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) microscope system that uses a 16 channel multi-anode PMT detector. Multiphoton excitation minimizes out-of-focus photobleaching, multifocal excitation reduces non-linear in-plane photobleaching effects and TCSPC electronics provide photon-efficient detection of the fluorescence decay profile. TCSPC detection is less prone to bleaching- and movement-induced artefacts compared to wide-field time-gated or frequency-domain FLIM. This microscope is therefore capable of acquiring 3-D FLIM images at significantly increased speeds compared to single beam multiphoton microscopy and we demonstrate this with live cells expressing a GFP tagged protein. We also apply this system to time-lapse FLIM of NAD(P)H autofluorescence in single live cells and report measurements on the change in the fluorescence decay profile following the application of a known metabolic inhibitor.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...