Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Biomech (Bristol, Avon) ; 71: 59-67, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31704536

RESUMO

BACKGROUND: Novel lower-limb prostheses aim to improve the quality of locomotion of individuals with an amputation. This study evaluates the biomechanics of a novel bionic foot during walking. METHODS: Able-bodied individuals (n = 7) and individuals with a transfemoral (n = 6) or transtibial amputation (n = 6) were included. Able-bodied individuals conducted one experimental trial, whereas individuals with transtibial and transfemoral amputations conducted a familiarization (with current prosthesis) and two experimental trials using a passive and bionic prosthesis. Each trial consisted of 3 bouts of 2 min of treadmill walking at different speeds. Biomechanical data were gathered using a force platform and motion capture system and analysed using Statistical Parametric Mapping and (non)-parametric tests. FINDINGS: Conventional prosthetic feet alter gait patterns and induce locomotion difficulties. While walking at a normal speed with the passive prosthesis, transtibial amputees display reduced maximum heel forces, increased ankle and trunk angular velocities at midstance, and increased knee angle during stance and swing phases on their effected side (P ≤ 0.026). Improved lower-limb kinematics was demonstrated during slow and normal speed walking with the bionic prosthesis; however, dynamic trunk stability was negatively impacted during this condition. The bionic prosthesis did not benefit transfemoral amputees at any walking speed. INTERPRETATION: Transtibial amputees can better approximate typical movement patterns at slow and normal walking speeds using the novel bionic prosthesis; however the same benefit was not observed in transfemoral amputees.


Assuntos
Amputados , Membros Artificiais , Marcha/fisiologia , Perna (Membro)/fisiologia , Adulto , Amputação Cirúrgica , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Feminino , Humanos , Locomoção , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Caminhada/fisiologia , Velocidade de Caminhada
2.
Med Eng Phys ; 36(12): 1567-76, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25217007

RESUMO

Endovascular treatment for patients with a proximal neck anatomy outside instructions for use is an ongoing topic of debate in endovascular aneurysm repair. This paper employs the finite element method to offer insight into possible adverse effects of deploying a stent graft into an angulated geometry. The effect of angulation, straight neck length and device oversize was investigated in a full factorial parametric analysis. Stent apposition, area reduction of the graft, asymmetry of contact forces and the ability to find a good seal were investigated. Most adverse effects are expected for combinations of high angulation and short straight landing zones. Higher oversize has a beneficiary effect, but not enough to compensate the adverse effects of (very) short and angulated angles. Our analysis shows that for an angle between the suprarenal aorta and proximal neck above 60°, proximal kinking of the device can occur. The method used offers a engineering view on the morphological limits of EVAR for a clinically used device.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares , Stents , Algoritmos , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular/efeitos adversos , Simulação por Computador , Procedimentos Endovasculares/efeitos adversos , Análise de Elementos Finitos , Humanos , Modelos Cardiovasculares , Desenho de Prótese , Stents/efeitos adversos
3.
J Biomech ; 47(4): 890-8, 2014 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-24480704

RESUMO

Carotid artery stenting is emerging as an alternative technique to surgery for the treatment of symptomatic severe carotid stenosis. Clinical and experimental evidence demonstrates that both plaque morphology and biomechanical changes due to the device implantation can be possible causes of an unsuccessful treatment. In order to gain further insights of the endovascular intervention, a virtual environment based on structural finite element simulations was built to emulate the stenting procedure on generalized atherosclerotic carotid geometries which included a damage model to quantify the injury of the vessel. Five possible lesion scenarios were simulated by changing both material properties and vascular geometrical features to cover both presumed vulnerable and stable plaques. The results were analyzed with respect to lumen gain and wall stresses which are potentially related to the failure of the procedure according to previous studies. Our findings show that an elliptic lumen shape and a thinner fibrous cap with an underlying lipid pool result in higher stenosis reduction, while large calcifications and fibrotic tissue are more prone to recoil. The shielding effect of a thicker fibrous cap helps to reduce local compressive stresses in the soft plaque. The presence of a soft plaque reduces the damage in the healthy vascular structures. Contrarily, the presence of hard plaque promotes less damage volume in the fibrous cap and reduces stress peaks in this region, but they seem to increase stresses in the media-intima layer. Finally the reliability of the achieved results was put into clinical perspective.


Assuntos
Lesões das Artérias Carótidas/etiologia , Estenose das Carótidas/terapia , Análise de Elementos Finitos , Modelos Cardiovasculares , Placa Aterosclerótica/terapia , Stents/efeitos adversos , Angioplastia/efeitos adversos , Angioplastia/métodos , Artérias Carótidas/patologia , Lesões das Artérias Carótidas/patologia , Estenose das Carótidas/patologia , Humanos , Placa Aterosclerótica/patologia , Reprodutibilidade dos Testes , Túnica Íntima/patologia
4.
J Biomech ; 46(14): 2477-82, 2013 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-23953501

RESUMO

The presented study details a combined experimental and computational method to assess and compare the mechanical behavior of the main body of 4 different stent graft designs. The mechanical response to a flat plate compression and radial crimping of the devices is derived and related to geometrical and material features of different stent designs. The finite element modeling procedure is used to complement the experimental results and conduct a solution sensitivity study. Finite element evaluations of the mechanical behavior match well with experimental findings and are used as a quantitative basis to discuss design characteristics of the different devices.


Assuntos
Desenho de Prótese , Stents , Ligas , Aorta , Análise de Elementos Finitos , Poliésteres , Aço Inoxidável
5.
J Mech Behav Biomed Mater ; 13: 129-39, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22842656

RESUMO

The presented study details the virtual deployment of a bifurcated stent graft (Medtronic Talent) in an Abdominal Aortic Aneurysm model, using the finite element method. The entire deployment procedure is modeled, with the stent graft being crimped and bent according to the vessel geometry, and subsequently released. The finite element results are validated in vitro with placement of the device in a silicone mock aneurysm, using high resolution CT scans to evaluate the result. The presented work confirms the capability of finite element computer simulations to predict the deformed configuration after endovascular aneurysm repair (EVAR). These simulations can be used to quantify mechanical parameters, such as neck dilations, radial forces and stresses in the device, that are difficult or impossible to obtain from medical imaging.


Assuntos
Análise de Elementos Finitos , Stents , Enxerto Vascular/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Teste de Materiais , Desenho de Prótese , Silicones
6.
J Biomech ; 45(8): 1353-9, 2012 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-22483228

RESUMO

There is a growing interest in virtual tools to assist clinicians in evaluating different procedures and devices for endovascular treatment. In the present study we use finite element analysis to investigate the influence of stent design and vessel geometry for stent assisted coiling of intracranial aneurysms. Nine virtual stenting procedures were performed: three nitinol stent designs ((i) an open cell stent resembling the Neuroform, (ii) a generic stiff and (iii) a more flexible closed cell design), were deployed in three patient-specific cerebral aneurysmatic vessels. We investigated the percentage of strut area covering the aneurysm neck, the straightening induced on the cerebrovasculature by the stent placement (quantified by the reduction in tortuosity), and stent apposition to the wall (quantified as the percentage of struts within 0.2mm of the vessel). The results suggest that the open cell design better covers the aneurysm neck (11.0±1.1%) compared to both the stiff (7.8±1.6%) and flexible (8.7±1.6%) closed cell stents, and induces less straightening of the vessel (-5.1±1.6% vs. -42.9±9.8% and -26.9±11.9% ). The open cell design has, however, less struts apposing well to the vessel wall (56.0±6.4%) compared to the flexible (73.4±4.6%) and stiff (70.4±5.1%) closed cell design. With the presented study, we hope to contribute to and improve aneurysm treatment, using a novel patient specific environment as a possible pre-operative tool to evaluate mechanical stent behavior in different vascular geometries.


Assuntos
Artérias Cerebrais/fisiopatologia , Artérias Cerebrais/cirurgia , Circulação Cerebrovascular , Aneurisma Intracraniano/fisiopatologia , Aneurisma Intracraniano/cirurgia , Modelos Cardiovasculares , Stents , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Prótese Vascular , Artérias Cerebrais/patologia , Simulação por Computador , Desenho Assistido por Computador , Análise de Falha de Equipamento , Humanos , Aneurisma Intracraniano/patologia , Desenho de Prótese , Resultado do Tratamento
8.
Epidemiol Infect ; 122(3): 359-65, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10459637

RESUMO

Potential risk factors for sporadic verocytotoxin-producing Escherichia coli (VTEC) infection in Belgium were investigated in a matched case-control study. Thirty-seven cases, 8 infected with O157 VTEC strains (all eaeA-positive), 29 with non-O157 VTEC strains (13 eaeA-positive and 16 eaeA-negative) and 69 matched controls were interviewed. In a conditional logistic regression analysis, consumption of fish appeared to be a risk factor for infection (adjusted odds ratio (OR) 3.25, P = 0.04). Contact with dogs (OR 0.27, P = 0.04) and consumption of shellfish (OR 0.19, P = 0.05) showed a negative association, corresponding to a decrease in risk. These findings might be explained if low level environmental exposure to VTEC induces protective immunity. Eating raw meat, a frequent habit in Belgium, or hamburgers, or eating in a fast-food restaurant was not more frequently reported by cases than controls. The exposures causing sporadic infections with VTEC, in particular non-O157 strains, may be very different from those which led to outbreaks, and may account for more cases overall.


Assuntos
Toxinas Bacterianas/biossíntese , Infecções por Escherichia coli/epidemiologia , Escherichia coli O157/isolamento & purificação , Escherichia coli/isolamento & purificação , Comportamento Alimentar , Adolescente , Adulto , Distribuição por Idade , Idoso , Animais , Bélgica/epidemiologia , Estudos de Casos e Controles , Criança , Pré-Escolar , Citotoxinas/biossíntese , Escherichia coli/patogenicidade , Infecções por Escherichia coli/microbiologia , Infecções por Escherichia coli/transmissão , Escherichia coli O157/patogenicidade , Feminino , Peixes , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Razão de Chances , Análise de Regressão , Fatores de Risco , Toxina Shiga I
9.
Horm Res ; 50(5): 271-5, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9873195

RESUMO

In a group of 15 male Wistar rats overfed with cafeteria foods (delivering a mean fat percentage of 60%) during 5 months from the age of 8 weeks and in a control group of 15 rats fed with a standard chow for the same period, serum leptin, insulin and corticosterone were measured by RIA and body composition was determined by dual-energy X-ray absorptiometry. Significantly higher fasting serum concentrations of leptin, insulin and corticosterone were found in the cafeteria-diet group. Fasting leptin concentrations were significantly higher in rats with a body fat percentage of more than 25% compared to the others, irrespective of the type of feeding. The log serum leptin correlated positively with body fat percentage and fasting insulin concentration but not with corticosterone concentration. Leptin concentration corrected for body fat mass was, however, comparable between the two diet groups, while the leptin/insulin ratio was lower in the cafeteria-diet group. In conclusion, chronic overfeeding resulting in an increased body fat percentage in rats is associated with hyperleptinemia, hyperinsulinemia and hypercorticism. Serum leptin levels appear to primarily track total body fat percentage and are unaffected by dietary fat manipulation in cafeteria-diet-induced obese rats.


Assuntos
Tecido Adiposo/metabolismo , Corticosterona/sangue , Dieta , Insulina/sangue , Proteínas/metabolismo , Absorciometria de Fóton , Animais , Composição Corporal , Gorduras na Dieta/administração & dosagem , Ingestão de Alimentos , Leptina , Masculino , Radioimunoensaio , Ratos , Ratos Wistar , Aumento de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA