Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Belg Soc Radiol ; 108(1): 22, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38435134

RESUMO

Large gastric hernias are common and usually cause minor symptoms. Rarely, complete intrathoracic herniation of the stomach is complicated by strangulation. The underlying mechanism can be gastric volvulus or the less recognized phenomenon of gastric fundus redescent. We describe a case where this rare but potentially lethal complication of gastric herniation is present. Additionally, we show that gastric pneumatosis, a sign associated with ischemia, can be initially visualized on a plain chest radiograph in this setting. Teaching point: Redescent of the fundus is a possible, but unrecognized cause of gastric strangulation in intrathoracic stomachs.

2.
Am J Case Rep ; 24: e940789, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37779307

RESUMO

BACKGROUND AL amyloidomas are solitary, localized, tumor-like deposits of immunoglobulin light-chain-derived amyloid fibrils in the absence of systemic amyloidosis. A rare entity, they have been described in various anatomical sites, typically in spatial association with a sparse lymphoplasmacytic infiltrate, ultimately corresponding to a clonal, malignant, lymphomatous disorder accounting for the amyloidogenic activity. Most frequently, the amyloidoma-associated hematological disorder corresponds to either a solitary plasmacytoma or an extranodal marginal zone lymphoma of MALT. Much rarer is the association with lymphoplasmacytic lymphoma, which by itself is usually a bone marrow-bound disorder with systemic burden. The almost anecdotic combination of an amyloidoma and a localized lymphoplasmacytic lymphoma deserves attention, as it entails a thorough diagnostic workup to exclude systemic involvement and a proportionate therapeutic approach to avoid overtreatment. A review of the literature provides an insight on pathogenesis and prognosis, and can assist both pathologists and clinicians in establishing optimal patient management strategies. CASE REPORT We herein report the incidental finding of a subcutaneous amyloidoma caused by a spatially related, similarly localized lymphoplasmacytic lymphoma diagnosed in a 54-year-old female patient with no other disease localizations and a complete remission following 2 subsequent surgical excisions. CONCLUSIONS Whatever the specific combination of an amyloidoma and the related hematological neoplasm, a multidisciplinary collaboration and a comprehensive clinical-pathological staging are warranted to exclude systemic involvement and identify patients with localized diseases who would benefit from local active treatment and close follow-up.


Assuntos
Amiloidose , Linfoma de Zona Marginal Tipo Células B , Plasmocitoma , Neoplasias de Tecidos Moles , Macroglobulinemia de Waldenstrom , Feminino , Humanos , Pessoa de Meia-Idade , Amiloidose/diagnóstico , Amiloidose/terapia , Amiloide , Linfoma de Zona Marginal Tipo Células B/diagnóstico , Linfoma de Zona Marginal Tipo Células B/terapia , Macroglobulinemia de Waldenstrom/complicações , Macroglobulinemia de Waldenstrom/diagnóstico , Macroglobulinemia de Waldenstrom/terapia , Plasmocitoma/diagnóstico , Plasmocitoma/terapia
3.
BMC Med Imaging ; 21(1): 18, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33546626

RESUMO

BACKGROUND: Accurate staging of patients with gastric cancer is necessary for selection of the most appropriate and personalized therapy. Computed tomography (CT) is currently used as primary staging tool, being widely available with a relatively high accuracy for the detection of parenchymal metastases, but with low sensitivity for the detection of peritoneal metastases. Magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) has a very high contrast resolution, suggesting a higher diagnostic performance in the detection of small peritoneal lesions. The aim of this study was to retrospectively evaluate the added value of whole-body diffusion-weighted MRI (WB-DWI/MRI) to CT for detection of peritoneal carcinomatosis (PC) and distant metastases in the preoperative staging of gastric cancer. METHODS: This retrospective study included thirty-two patients with a suspicion of gastric cancer/recurrence, who underwent WB-DWI/MRI at 1.5 T, in addition to CT of thorax and abdomen. Images were evaluated by two experienced abdominal radiologists in consensus. Histopathology, laparoscopy and/or 1-year follow-up were used as reference standard. RESULTS: For overall tumour detection (n = 32), CT sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) was 83.3%, 100%, 100% and 82.4% respectively. For WB-DWI/MRI these values were 100%, 92.9%, 94.7% and 100%, respectively. For staging (n = 18) malignant lymph nodes and metastases, CT had a sensitivity, specificity/PPV/NPV of 50%/100%/100%/71.4%, and 15.4%/100%/100%/31.3% respectively. For WB-DWI/MRI, all values were 100%, for both malignant lymph nodes and metastases. WB-DWI/MRI was significantly better than CT in detecting tumour infiltration of the mesenteric root, serosal involvement of the small bowel and peritoneal metastases for which WB-DWI/MRI was correct in 100% of these cases, CT 0%. CONCLUSIONS: WB-DWI/MRI is highly accurate for diagnosis, staging and follow-up of patients with suspected gastric cancer.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Tomografia Computadorizada por Raios X , Imagem Corporal Total/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células em Anel de Sinete/diagnóstico por imagem , Carcinoma de Células em Anel de Sinete/patologia , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Estadiamento de Neoplasias , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/secundário , Projetos Piloto , Valor Preditivo dos Testes , Período Pré-Operatório , Estudos Retrospectivos
4.
Clin Gastroenterol Hepatol ; 19(5): 947-954.e2, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32360982

RESUMO

BACKGROUND & AIMS: Higher infliximab trough levels are associated with clinical and endoscopic remission in patients with Crohn's disease (CD). We investigated pharmacodynamic features of infliximab and radiological healing. METHODS: We performed a substudy of the TAILORIX trial (patients with active luminal CD in Europe, treated with infliximab), analyzing baseline and week 54 magnetic resonance enterography (MRE) data. MREs were scored using the MaRIA score by blinded central readers. Radiologic response and remission were defined, based on MaRIA criteria in all segments, as scores below 11 and 7, respectively. We collected data on infliximab trough levels, biomarkers, and endoscopic findings. Our primary aim was to evaluate pharmacodynamic features associated with radiologic response and remission, based on MRE assessments at baseline and at 54 weeks after initiation of infliximab therapy. RESULTS: We analyzed data from 36 patients (50% female; median age 35.7 years; interquartile age range, 25.6-48.6 years; median disease duration, 1.5 months; interquartile duration range, 0.6-22.4 months). At week 54 of treatment, 36.4% of patients had a radiologic response, 30.3% of patients were in remission, and 71% had endoscopic features of remission. At baseline, there was a correlation between the CD endoscopic index of severity and MaRIA scores (κ = 0.46; P = .008), but we found no correlation at week 54 (κ = 0.06; P = .75). Radiologic remission correlated with infliximab trough level at week 14 (P = .049) when the infliximab trough level cut-off value was set at 7.8 µg/mL (area under the curve, 0.74; 75% sensitivity; 86% specificity; 90% negative predictive value; 57% positive predictive value). Radiologic response correlated with infliximab trough levels at week 14 (P = .048) when the infliximab trough level cut-off value was set at 7.8 µg/mL (area under the curve, 0.73; 70% sensitivity; 90% specificity; 86% negative predictive value; 78% positive predictive value) and with continuous pharmacologic evidence of response (infliximab trough levels above 5.0 µg/mL at all time points) (P = .034). CONCLUSIONS: In a substudy of data from the TAILORIX trial of patients with active luminal CD, we identified a relationship between exposure to infliximab and radiologic evidence of outcomes.


Assuntos
Doença de Crohn , Adulto , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/tratamento farmacológico , Feminino , Fármacos Gastrointestinais/uso terapêutico , Humanos , Infliximab/uso terapêutico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
5.
Radiol Cardiothorac Imaging ; 2(2): e200196, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33778576

RESUMO

PURPOSE: To demonstrate the accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of coronavirus disease 2019 (COVID-19) infection in patients in the emergency department. MATERIALS AND METHODS: This was a Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective study. From March 14 to 24, 2020, 192 patients in the emergency department with symptoms suggestive of COVID-19 infection were studied by using low-dose chest CT and real-time reverse transcription polymerase chain reaction (RT-PCR). Image analysis included the likelihood of COVID-19 infection and the semiquantitative extent of lung involvement. CT images were analyzed by two radiologists blinded to the RT-PCR results. Reproducibility was assessed using the McNemar test and intraclass correlation coefficient. Time between CT acquisition and report was measured. RESULTS: When compared with RT-PCR, low-dose submillisievert chest CT demonstrated excellent sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosis of COVID-19 (86.7%, 93.6%, 91.1%, 90.3%, and 90.2%, respectively), in particular in patients with clinical symptoms for more than 48 hours (95.6%, 93.2%, 91.5%, 96.5%, and 94.4%, respectively). In patients with a positive CT result, the likelihood of disease increased from 43.2% (pretest probability) to 91.1% or 91.4% (posttest probability), while in patients with a negative CT result, the likelihood of disease decreased to 9.6% or 3.7% for all patients or those with clinical symptoms for >48 hours. The prevalence of alternative diagnoses based on chest CT in patients without COVID-19 infection was 17.6%. The mean effective radiation dose was 0.56 mSv ± 0.25 (standard deviation). Median time between CT acquisition and report was 25 minutes (interquartile range: 13-49 minutes). Intra- and interreader reproducibility of CT was excellent (all intraclass correlation coefficients ≥ 0.95) without significant bias in the Bland-Altman analysis. CONCLUSION: Low-dose submillisievert chest CT allows for rapid, accurate, and reproducible assessment of COVID-19 infection in patients in the emergency department, in particular in patients with symptoms lasting longer than 48 hours. Chest CT has the additional advantage of offering alternative diagnoses in a significant subset of patients.© RSNA, 2020.

6.
Radiol Cardiothorac Imaging ; 2(5): e200441, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33778634

RESUMO

PURPOSE: To compare the prognostic value and reproducibility of visual versus AI-assisted analysis of lung involvement on submillisievert low-dose chest CT in COVID-19 patients. MATERIALS AND METHODS: This was a HIPAA-compliant, institutional review board-approved retrospective study. From March 15 to June 1, 2020, 250 RT-PCR confirmed COVID-19 patients were studied with low-dose chest CT at admission. Visual and AI-assisted analysis of lung involvement was performed by using a semi-quantitative CT score and a quantitative percentage of lung involvement. Adverse outcome was defined as intensive care unit (ICU) admission or death. Cox regression analysis, Kaplan-Meier curves, and cross-validated receiver operating characteristic curve with area under the curve (AUROC) analysis was performed to compare model performance. Intraclass correlation coefficients (ICCs) and Bland- Altman analysis was used to assess intra- and interreader reproducibility. RESULTS: Adverse outcome occurred in 39 patients (11 deaths, 28 ICU admissions). AUC values from AI-assisted analysis were significantly higher than those from visual analysis for both semi-quantitative CT scores and percentages of lung involvement (all P<0.001). Intrareader and interreader agreement rates were significantly higher for AI-assisted analysis than visual analysis (all ICC ≥0.960 versus ≥0.885). AI-assisted variability for quantitative percentage of lung involvement was 17.2% (coefficient of variation) versus 34.7% for visual analysis. The sample size to detect a 5% change in lung involvement with 90% power and an α error of 0.05 was 250 patients with AI-assisted analysis and 1014 patients with visual analysis. CONCLUSION: AI-assisted analysis of lung involvement on submillisievert low-dose chest CT outperformed conventional visual analysis in predicting outcome in COVID-19 patients while reducing CT variability. Lung involvement on chest CT could be used as a reliable metric in future clinical trials.

7.
J Cardiovasc Comput Tomogr ; 12(6): 509-515, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30509378

RESUMO

PURPOSE: To evaluate the performance and clinical feasibility of 0.25 mm resolution mode of a dual-energy photon-counting detector (PCD) computed tomography (CT) system for coronary stent imaging and to compare the results to state-of-the-art dual-energy energy-integrating detector (EID) CT. MATERIALS AND METHODS: Coronary stents with different diameters (2.0-4.0 mm) were examined inside a coronary artery phantom consisting of plastic tubes filled with iodine-based and gadolinium-based contrast material diluted to approximate clinical concentrations (n = 18). EID images were acquired using 2nd and 3rd generation dual-source CT systems (SOMATOM Flash and SOMATOM Force, Siemens Healthcare) at 0.60 mm (defined as standard-resolution (SR)) isotropic voxel size. Radiation-dose matched PCD images were acquired using a human prototype PCD system (Siemens Healthcare) at 0.50 mm (SR) and 0.25 mm (HR) imaging modes. Images were reconstructed using optimized convolution kernels. RESULTS: Dual-energy HR PCD images significantly better stent lumen visualization (median: 69.5%, IQR: 61.2-78.9%) over dual-energy EID, and standard-resolution PCD images (median: 53.2-57.4%, all P < 0.01). HR PCD acquisitions reconstructed at SR image voxel size showed 25.3% lower image noise compared to SR PCD acquisitions (P < 0.001). High-resolution iodine and gadolinium maps, as well as virtual monoenergetic images, were calculated from the PCD data and enabled estimation of contrast agent concentration in the lumen without interference from the coronary stent. CONCLUSION: HR spectral PCD imaging significantly improves coronary stent lumen visibility over dual-energy EID. When the PCD-HR data was reconstructed into standard voxel sizes (0.5 mm isotropic) the image noise decreased by 25% compared to SR acquisition of PCD. Both dual-energy systems were consistent in estimating contrast agent concentrations.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/instrumentação , Fótons , Stents , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste , Angiografia Coronária/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Imagens de Fantasmas , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Tomógrafos Computadorizados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...