Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Clin Microbiol Infect Dis ; 34(3): 535-42, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25326870

RESUMO

Conventional diagnosis of infectious diarrhea caused by bacteria is time-consuming, labor-intensive, and has a suboptimal sensitivity. We have therefore developed a multiplex real-time polymerase chain reaction (PCR) for the simultaneous detection of Campylobacter jejuni, Salmonella spp., Shigella spp./enteroinvasive Escherichia coli (EIEC), and Yersinia enterocolitica in fecal samples. No cross reactivity between the different pathogens was observed, and the multiplex setup of the assay did not have an impact on the sensitivity of the PCR. The analytical sensitivity was 87 CFU/mL for C. jejuni, 61 CFU/mL for Shigella spp./EIEC, 5,528 CFU/mL for Salmonella spp., and 1,306 CFU/mL for Y. enterocolitica. An extensive validation of the assay was performed by testing 1,687 patient samples by both PCR and with conventional techniques. The use of PCR increased the overall clinical sensitivity from 78 to 100 % (p < 0.0001), the specificity was 99.4 % for the PCR, compared with 99.9 % for conventional culture. The novel PCR assay allows for rapid, sensitive, inexpensive, and high-throughput testing of the most common bacterial causes of gastroenteritis.


Assuntos
Infecções por Campylobacter/diagnóstico , Campylobacter jejuni/isolamento & purificação , Infecções por Enterobacteriaceae/diagnóstico , Enterobacteriaceae/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Fezes/microbiologia , Humanos , Sensibilidade e Especificidade
2.
Int J Environ Anal Chem ; 26(3-4): 279-93, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3533808

RESUMO

Linear Alkylbenzenesulphonates (LAS), a major anionic surfactant used in laundry products, can be measured specifically in the environment by instrumental analysis. In addition to a desulphonation-gas chromatography approach, a method based on high performance liquid chromatography has been developed. The main features of the methods are outlined, and LAS concentrations measured in sewage sludge, sediments and sludge amended soils are reported. Knowledge of usage volumes, sewage treatment practices and environmental transport and transformation mechanisms has been used to predict concentrations of LAS. These calculated concentrations were found to agree well with those actually measured in the environment. Both measured and calculated ambient concentrations of LAS are below those which could produce potentially adverse effects in representative surface water, benthic and terrestrial organisms.


Assuntos
Benzenossulfonatos/análise , Esgotos/análise , Poluentes do Solo/análise , Solo/análise , Poluentes Químicos da Água/análise , Poluentes da Água/análise , Alcanos/análise , Alcanos/toxicidade , Animais , Benzenossulfonatos/toxicidade , Biodegradação Ambiental , Cromatografia Líquida de Alta Pressão , Humanos , Poluentes do Solo/toxicidade , Microbiologia da Água , Poluentes Químicos da Água/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...