Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 22(8): 1940-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23708381

RESUMO

PURPOSE: Primary stability in arthrodesis of the knee can be achieved by external fixation, intramedullary nailing or plate fixation. Each method has different features and results. We present a practical algorithm for arthrodesis of the knee following a failed (infected) arthroplasty, based on our own results and a literature review. METHODS: Between 2004 and 2010, patients were included with an indication for arthrodesis after failed (revision) arthroplasty of the knee. Patients were analyzed with respect to indication, fusion method and bone contact. End-point was solid fusion. RESULTS: Twenty-six arthrodeses were performed. Eighteen patients were treated because of an infected arthroplasty. In total, ten external fixators, ten intramedullary nails and six plate fixations were applied; solid fusion was achieved in 3/10, 8/10 and 3/6, respectively. CONCLUSIONS: There is no definite answer as to which method is superior in performing an arthrodesis of the knee. Intramedullary nailing achieved the best fusion rates, but was used most in cases without--or cured--infection. Our data and the contemporary literature suggest that external fixation can be abandoned as standard fusion method, but can be of use following persisting infection. The Ilizarov circular external fixator, however, seems to render high fusion rates. Good patient selection and appropriate individual treatment are the key to a successful arthrodesis. Based upon these findings, a practical algorithm was developed.


Assuntos
Artrodese/métodos , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Idoso , Artrodese/instrumentação , Feminino , Humanos , Masculino , Infecções Relacionadas à Prótese/etiologia , Reoperação , Estudos Retrospectivos , Falha de Tratamento
2.
Scand J Rheumatol ; 40(3): 225-31, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21261551

RESUMO

OBJECTIVE: Insufficient data are available on the efficacy of combined conservative interventions recommended by treatment guidelines for knee/hip osteoarthritis (OA). The aims of this observational cohort study were (i) to estimate the results of an evidence-based 12-week tailored multimodal conservative treatment protocol for patients with knee/hip OA and (ii) to identify predictors for response. METHODS: After obtaining data on previous OA-related interventions, multimodal treatment was offered to patients with knee and/or hip OA at a specialized outpatient clinic. Treatment with analgesics was tailored using a numeric rating scale (NRS) for pain, aiming for NRS ≤ 4. The following outcome measures were assessed: (i) the proportion of patients fulfilling OMERACT-OARSI (Outcome Measures in Rheumatoid Arthritis Clinical Trials/Osteoarthritis Research Society International) responder criteria and (ii) the proportion of patients with NRS pain ≤ 4 after 12 weeks. RESULTS: A total of 183 out of 299 patients was included. OMERACT-OARSI responder criteria were fulfilled at 12 weeks in 47% of patients; 39% reached NRS pain ≤ 4. The only independent predictor for response was the number of previously used non-steroidal anti-inflammatory drugs (NSAIDs). The majority of patients had not been exposed adequately to conservative treatment modalities for knee and/or hip OA in the past (81%). CONCLUSION: Evidence-based multimodal conservative treatment using a standardized protocol for knee and/or hip OA is feasible and successful in 47% of patients. In general, response could not be predicted. Basic first-line recommended conservative treatment options have not been used adequately prior to referral to secondary care in the vast majority of patients.


Assuntos
Analgésicos/uso terapêutico , Suplementos Nutricionais , Osteoartrite do Quadril/terapia , Osteoartrite do Joelho/terapia , Dor/tratamento farmacológico , Modalidades de Fisioterapia , Condroitina/administração & dosagem , Estudos de Coortes , Medicina Baseada em Evidências , Feminino , Glucosamina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/fisiopatologia , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/fisiopatologia , Dor/etiologia , Dor/fisiopatologia , Medição da Dor , Índice de Gravidade de Doença , Inquéritos e Questionários , Resultado do Tratamento
4.
J Bone Joint Surg Br ; 91(1): 31-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19092001

RESUMO

We report the long-term outcome of a modified second-generation cementing technique for fixation of the acetabular component of total hip replacement. An earlier report has shown the superiority of this technique assessed by improved survival compared with first-generation cementing. The acetabular preparation involved reaming only to the subchondral plate, followed by impaction of the bone in the anchorage holes. Between 1978 and 1993, 287 total hip replacements were undertaken in 244 patients with a mean age of 65.3 years (21 to 90) using a hemispherical Weber acetabular component with this modified technique for cementing and a cemented femoral component. The survival with acetabular revision for aseptic loosening as the endpoint was 99.1% (95% confidence interval 97.9 to 100 after ten years and 85.5% (95% confidence interval 74.7 to 96.2) at 20 years. Apart from contributing to a long-lasting fixation of the component, this technique also preserved bone, facilitating revision surgery when necessary.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Cimentos Ósseos/uso terapêutico , Cimentação/métodos , Prótese de Quadril/efeitos adversos , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia , Radiografia , Amplitude de Movimento Articular/fisiologia , Resultado do Tratamento , Adulto Jovem
5.
J Bone Joint Surg Am ; 87(7): 1522-33, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15995120

RESUMO

BACKGROUND: The mechanisms leading to aseptic loosening of a total hip replacement are not fully understood. A fibrous tissue interface can be present around the implant. Hypothetically, component micromovements can compress this interface and cause increased fluid pressure according to biphasic models. We tested the hypothesis that compression of a fibrous membrane with or without the presence of high-density polyethylene particles leads to bone degradation. METHODS: A titanium implant was inserted in forty-five rabbit tibiae, and, after osseous integration was achieved, a fibrous tissue interface was generated. The animals were randomized to undergo a sham operation, treatment with compression of the fibrous membrane, treatment with high-density polyethylene particles, or treatment with both compression and particles. Morphometric analysis of the surrounding bone was performed on cryostat sections after Giemsa staining and staining of tartrate-resistant acid phosphatase activity. RESULTS: Forty specimens were available for analysis; five tibiae with an infection were excluded. After nine weeks, the controls showed vital bone, whereas the specimens treated with compression showed necrosis of bone and replacement of bone by cartilage in a discontinuous layer (p < 0.05 for both) but not fibrous tissue. Treatment with high-density polyethylene particles caused replacement of bone by fibrous tissue (p < 0.05) but not necrosis or cartilage formation. Compression combined with the presence of high-density polyethylene particles caused bone necrosis and loss of bone with replacement by cartilage and fibrous tissue (p < 0.05). CONCLUSIONS: In this in vivo study in rabbits, fibrous membrane compression led to bone necrosis and cartilage formation, possibly because of fluid pressure or fluid flow, whereas the presence of high-density polyethylene particles led to the loss of bone with replacement of bone by fibrous tissue. Cartilage formation may be a protective response to fluid pressure and/or fluid flow. Fibrous membrane compression may play an important role in the early stages of loosening of a total hip replacement.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Tecido Conjuntivo/fisiopatologia , Prótese de Quadril/efeitos adversos , Polietileno/efeitos adversos , Falha de Prótese , Animais , Osso e Ossos/fisiopatologia , Força Compressiva , Modelos Animais , Coelhos , Titânio/efeitos adversos
6.
Clin Orthop Relat Res ; (419): 107-14, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15021140

RESUMO

Between 1974 and 1989, 315 primary total hip replacements (274 patients) were done using the cemented Weber Rotation prosthesis and standardized operative technique, which was modified for the stem in 1978. After the first postoperative year, all patients had routine clinical and radiologic examinations at 2-year intervals. Twenty-one patients (22 hips) were lost to followup. At the most recent followup, 30 of 293 hips (253 patients) had been revised: 24 hips for aseptic loosening, five hips for infection, and one hip for a femoral fracture. Survivorship analyses with revision for aseptic loosening as an end point for the 315 hips showed 93% and 78% survival after 10 and 15 years, respectively. Separate survival analyses for the socket showed 99% and 89% survival after 10 and 15 years, respectively. The stem had a survival of 94% and 81%, respectively, during the same time. Survival at 15 years with radiologic evidence of loosening as an end point was 85% for the socket and 72% for the stem. The cementing technique and the design of the acetabular component significantly influenced the rate of loosening. Survivorship analyses with revision for aseptic loosening of the socket, using a modified second generation cementing technique and a hemispheric socket, showed 100% survival after 10 years and 98% after 13 years.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Instabilidade Articular/cirurgia , Infecções Relacionadas à Prótese/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Estudos de Coortes , Intervalos de Confiança , Feminino , Seguimentos , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Humanos , Instabilidade Articular/etiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Probabilidade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/terapia , Recuperação de Função Fisiológica , Reoperação , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...