Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38542624

RESUMO

This paper reports on the design, implementation, and characterization of a current-mode analog-front-end circuit for capacitance-to-voltage conversion that can be used in connection with a large variety of sensors and actuators in industrial and rehabilitation medicine applications. The circuit is composed by: (i) an oscillator generating a square wave signal whose frequency and pulse width is a function of the value of input capacitance; (ii) a passive low-pass filter that extracts the DC average component of the square wave signal; (iii) a DC-DC amplifier with variable gain ranging from 1 to 1000. The circuit has been designed in the current-mode approach by employing the second-generation current conveyor circuit, and has been implemented by using commercial discrete components as the basic blocks. The circuit allows for gain and sensitivity tunability, offset compensation and regulation, and the capability to manage various ranges of variations of the input capacitance. For a circuit gain of 1000, the measured circuit sensitivity is equal to 167.34 mV/pF with a resolution in terms of capacitance of 5 fF. The implemented circuit has been employed to measure the variations of the capacitance of a McKibben pneumatic muscle associated with the variations of its length that linearly depend on the circuit output voltage. Under step-to-step conditions of movement of the pneumatic muscle, the overall system sensitivity is equal to 70 mV/mm with a standard deviation error of the muscle length variation of 0.008 mm.

2.
IEEE Trans Biomed Circuits Syst ; 16(6): 1313-1324, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36155429

RESUMO

The paper describes the design, implementation, and characterization of a novel multilevel synchronized pulse position modulation paradigm for high efficiency optical biotelemetry links. The entire optoelectronic architecture has been designed with the aim to improve the efficiency of the data transmission and decrease the overall power consumption that are key factors for the fabrication of implantable and wearable medical devices. By employing specially designed digital architectures, the proposed modulation technique automatically transmits more than one bit per symbol together with the reference clock signal enabling the decoding process of the received coded data. In the present case, the paper demonstrates the capability of the modulation technique to transmit symbols composed by 3 and 4 bits. This has been achieved by developing a prototype of an optical biotelemetry system implemented on an FPGA board that, making use of 500 ps laser pulses, operates under the following two working conditions: (i) 40 MHz clock signal corresponding to a baud rate of 40 Mega symbol per second for symbols composed by 3 bits; (ii) 30 MHz clock signal corresponding to a baud rate of 30 Mega symbol per second for symbols composed by 4 bits. Thus, for both these two configurations the transmission data rate is 120 Mbps and the measured BER was lower than 10-10. Finally, the power consumption was found to be 1.95 and 1.8 mW and the resulting energy efficiencies were 16.25 and 15 pJ/bit for transmitted symbols composed by 3 and 4 bits/symbol, respectively.


Assuntos
Dispositivos Ópticos , Processamento de Sinais Assistido por Computador , Humanos , Desenho de Equipamento , Lasers , Próteses e Implantes
3.
IEEE Trans Biomed Circuits Syst ; 15(1): 177-187, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33606634

RESUMO

Size and absolute concentration of suspensions of nanoparticles are important information for the study and development of new materials and products in different industrial applications spanning from biotechnology and pharmaceutics to food preparation and conservation. Laser Transmission Spectroscopy (LTS) is the only methodology able to measure nanoparticle size and concentration by performing a single measurement. In this paper we report on a new variable gain calibration procedure for LTS-based instruments allowing to decrease of an order of magnitude the experimental indetermination of the particle size respect to the conventional LTS based on the double ratio technique. The variable gain calibration procedure makes use of a specifically designed tunable-gain, dual-channel, dual-phase Lock-In Amplifier (LIA) whose input voltage signals are those ones generated by two Si photodiodes that measure the laser beam intensities passing through the sample containing the nanoparticles and a reference optical path. The LTS variable gain calibration procedure has been validated by firstly using a suspension of NIST standard polystyrene nanoparticles even 36 hours after the calibration procedure was accomplished. The paper reports in detail the LIA implementation describing the design methodologies and the electronic circuits. As a case example of the characterization of biological nanostructures, we demonstrate that a single LTS measurement allowed to determine size density distribution of a population of extracellular vesicles extracted from orange juice (25 nm in size) with the presence of their aggregates having a size of 340 nm and a concentration smaller than 3 orders of magnitude.


Assuntos
Amplificadores Eletrônicos , Nanopartículas , Lasers , Tamanho da Partícula , Análise Espectral
4.
IEEE Trans Biomed Circuits Syst ; 14(3): 441-451, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32054584

RESUMO

This article reports an implantable transcutaneous telemetry for a brain machine interface that uses a novel optical communication system to achieve a highly energy-efficient link. Based on an pulse-based coding scheme, the system uses sub-nanosecond laser pulses to achieve data rates up to 300 Mbps with relatively low power levels when compared to other methods of wireless communication. This has been implemented using a combination of discrete components (semiconductor laser and driver, fast-response Si photodiode and interface) integrated at board level together with reconfigurable logic (encoder, decoder and processing circuits implemented using Xilinx KCU105 board with Kintex UltraScale FPGA). Experimental validation has been performed using a tissue sample that achieves representative level of attenuation/scattering (porcine skin) in the optical path. Results reveal that the system can operate at data rates up to 300 Mbps with a bit error rate (BER) of less than 10 -10, and an energy efficiency of 37 pJ/bit. This can communicate, for example, 1,024 channels of broadband neural data sampled at 18 kHz, 16-bit with only 11 mW power consumption.


Assuntos
Óptica e Fotônica/instrumentação , Telemetria/instrumentação , Tecnologia sem Fio/instrumentação , Animais , Interfaces Cérebro-Computador , Desenho de Equipamento , Humanos , Próteses e Implantes , Suínos
5.
Sensors (Basel) ; 16(6)2016 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-27338415

RESUMO

Less than thirty years after the giant magnetoresistance (GMR) effect was described, GMR sensors are the preferred choice in many applications demanding the measurement of low magnetic fields in small volumes. This rapid deployment from theoretical basis to market and state-of-the-art applications can be explained by the combination of excellent inherent properties with the feasibility of fabrication, allowing the real integration with many other standard technologies. In this paper, we present a review focusing on how this capability of integration has allowed the improvement of the inherent capabilities and, therefore, the range of application of GMR sensors. After briefly describing the phenomenological basis, we deal on the benefits of low temperature deposition techniques regarding the integration of GMR sensors with flexible (plastic) substrates and pre-processed CMOS chips. In this way, the limit of detection can be improved by means of bettering the sensitivity or reducing the noise. We also report on novel fields of application of GMR sensors by the recapitulation of a number of cases of success of their integration with different heterogeneous complementary elements. We finally describe three fully functional systems, two of them in the bio-technology world, as the proof of how the integrability has been instrumental in the meteoric development of GMR sensors and their applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...