1.
Forensic Sci Int Genet ; 7(3): 367-79, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23571070

RESUMO

A fluorescence-based assay specifically targeting human spermatozoa was tested and optimized for best staining results using a variety of mock sexual assault samples. Swab clippings versus whole swabs were evaluated for best sample preparation and to simplify workflow (direct application versus swab extraction). The practicality and sensitivity of Sperm Hy-Liter™ was compared to our current phase contrast microscopy protocol for searching for the presence of spermatozoa. Sperm Hy-Liter™ was more sensitive than phase contrast microscopy and was able to detect spermatozoa more effectively in actual sexual assault samples (recent [N=240] or 24 years old [N=4]) containing few spermatozoa. Correlations were drawn between the Sperm Hy-Liter™ spermatozoa counts and the AmpFlSTR(®) Profiler(®) Plus male profiles generated from the sperm cell DNA fractions of semen containing swabs and swab clippings. In addition, recovered spermatozoa from Sperm Hy-Liter™-stained slides with greater than 40 spermatozoa produced full STR male profiles in 20.3% of slides tested and partial STR male profiles in 52.8% of slides tested. The adoption of Sperm Hy-Liter™ offers a means to standardize and improve the efficiency of the microscopic screening of sexual assault evidence.


Assuntos
Delitos Sexuais , Espermatozoides , Humanos , Masculino , Microscopia de Fluorescência , Projetos Piloto , Reprodutibilidade dos Testes , Manejo de Espécimes
2.
Forensic Sci Int Genet ; 6(5): 511-22, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22264505

RESUMO

The Promega DNA IQ™ system is easily amenable to automation and has been an integral part of standard operating procedures for many forensic laboratories including those of the Royal Canadian Mounted Police (RCMP) since 2004. Due to some failure to extract DNA from samples that should have produced DNA using our validated automated DNA IQ™-based protocol, the competition for binding sites on the DNA IQ™ magnetic beads was more closely examined. Heme from heavily blooded samples interfered slightly with DNA binding. Increasing the concentration of Proteinase K during lysis of these samples did not enhance DNA recovery. However, diluting the sample lysate following lysis prior to DNA extraction overcame the reduction in DNA yield and preserved portions of the lysates for subsequent manual or automated extraction. Dye/chemicals from black denim lysates competed for binding sites on the DNA IQ™ beads and significantly reduced DNA recovery. Increasing the size or number of black denim cuttings during lysis had a direct adverse effect on DNA yield from various blood volumes. The dilution approach was successful on these samples and permitted the extraction of high DNA yields. Alternatively, shortening the incubation time for cell lysis to 30 min instead of the usual overnight at 56 °C prevented competition from black denim dye/chemicals and increased DNA yields.


Assuntos
DNA/metabolismo , Magnetismo , Automação , Sítios de Ligação , Humanos , Repetições de Microssatélites/genética