Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
PLoS One ; 15(1): e0225638, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31923229

RESUMO

INTRODUCTION: This study explores the possibility of a relationship between the sphericity degree of a target volume with the dose distribution. This relationship is evaluated based on the ratio isodose volume / target volume (IV/TV) and the metrics coverage, i.e., selectivity, gradient index, conformity index and mean dose when planning radiosurgery for vestibular schwannoma. METHODS: Sphericity degree (φ) was calculated for each target volume (TV) of 64 patients who underwent stereotactic radiosurgery (SRS) for vestibular schwannoma. The calculation of this parameter was developed using the theoretical definition for operational sphericity φ = VP/VCS. The values found are evaluated considering the following metrics:-Coverage (C), selectivity (S), gradient index (GI), Paddick conformity index (CIPaddick) and dose distribution (IV/TV). The planning was also carried out considering a spherical target volume defined in a spherical phantom. The spherical volume is the same as the target used in the treatment plan. The planning of the spherical target was considered as a reference plan to evaluate the dose distribution inside and outside the volume. RESULTS: It was possible to observe that the majority of target volumes has (ϕ) around 0,66-0,77, corresponding to 54,7% of the total. Considering the mean values for metrics, the results are: C = 0,98, S = 0,78, GI = 3,11 and CI = 0,81. The dose distribution was equivalent for treatment plans and reference plans. Quantitative analysis for IV/TV shows that these values are higher than 30% for treatment plans where shot density is large. CONCLUSION: This study demonstrates that de sphericity degree (φ) can be related to the dose distribution (IV/TV). Therefore the sphericity degree is a good parameter to evaluate the dose distribution of a plan for vestibular schwannoma treatment, considering the reference plan as being a spherical target using a leksell gamma knife® perfexion (LGKP). This study shows that the sphericity degree offers important information of the dose distribution outside and inside the target volume. This is not evaluated by the other parameters already implemented as metric to analyzing the GKP plans.


Assuntos
Neoplasias Encefálicas/radioterapia , Neuroma Acústico/radioterapia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Neoplasias Encefálicas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neuroma Acústico/patologia , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
Fetal Diagn Ther ; 42(1): 28-34, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27656888

RESUMO

OBJECTIVE: To present the feasibility of fetal myelomeningocele (MMC) repair through a mini-hysterotomy and to describe the perinatal results from our initial experience. METHODS: A descriptive study of cases of fetal MMC correction via mini-hysterotomy performed between 2014 and 2016. RESULTS: Forty-five women underwent fetal surgery and 87% (39/45) delivered. A complete multilayer correction of the MMC was possible in all cases. There were no maternal, fetal or neonatal deaths. No maternal or fetal complications occurred from fetal MMC correction until maternal hospital discharge. The average gestational age (GA) at surgery was 24.5 weeks (standard deviation, SD: 1.7; range: 20.7-26.9). The median hysterotomy length was 3.05 cm (SD: 0.39; range: 2.50-3.50). One patient (1/39; 2.6%) experienced chorioamniotic separation. Nine patients (9/39; 23.1%) had premature preterm rupture of membranes at a median GA of 34.1 weeks (range: 31.1-36.0). The average GA at delivery was 35.3 weeks (SD: 2.2; range: 27.9-39.1). Ninety-five percent (37/39) of our patients had an intact hysterotomy site at delivery. Ventriculoperitoneal shunt placement was necessary for 7.7% (3/39) of the neonates. CONCLUSION: Fetal MMC repair is feasible through a mini-hysterotomy. This approach appears to be associated with reduced risks of very preterm delivery and maternal, fetal and neonatal complications.


Assuntos
Histerotomia/efeitos adversos , Meningomielocele/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Adulto , Malformação de Arnold-Chiari/etiologia , Malformação de Arnold-Chiari/prevenção & controle , Brasil/epidemiologia , Estudos de Viabilidade , Feminino , Ruptura Prematura de Membranas Fetais/epidemiologia , Ruptura Prematura de Membranas Fetais/etiologia , Ruptura Prematura de Membranas Fetais/prevenção & controle , Seguimentos , Idade Gestacional , Humanos , Hidrocefalia/etiologia , Hidrocefalia/prevenção & controle , Hidrocefalia/cirurgia , Incidência , Recém-Nascido , Masculino , Meningomielocele/embriologia , Meningomielocele/fisiopatologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Gravidez , Segundo Trimestre da Gravidez , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/etiologia , Nascimento Prematuro/prevenção & controle , Risco , Derivação Ventriculoperitoneal/efeitos adversos
4.
J Neurosurg ; 125(Suppl 1): 129-138, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27903188

RESUMO

OBJECTIVE The role of tractography in Gamma Knife thalamotomy (GK-T) planning is still unclear. Pyramidal tractography might reduce the risk of radiation injury to the pyramidal tract and reduce motor complications. METHODS In this study, the ventralis intermedius nucleus (VIM) targets of 20 patients were bilaterally defined using Iplannet Stereotaxy Software, according to the anterior commissure-posterior commissure (AC-PC) line and considering the localization of the pyramidal tract. The 40 targets and tractography were transferred as objects to the GammaPlan Treatment Planning System (GP-TPS). New targets were defined, according to the AC-PC line in the functional targets section of the GP-TPS. The target offsets required to maintain the internal capsule (IC) constraint of < 15 Gy were evaluated. In addition, the strategies available in GP-TPS to maintain the minimum conventional VIM target dose at > 100 Gy were determined. RESULTS A difference was observed between the positions of both targets and the doses to the IC. The lateral (x) and the vertical (z) coordinates were adjusted 1.9 mm medially and 1.3 mm cranially, respectively. The targets defined considering the position of the pyramidal tract were more medial and superior, based on the constraint of 15 Gy touching the object representing the IC in the GP-TPS. The best strategy to meet the set constraints was 90° Gamma angle (GA) with automatic shaping of dose distribution; this was followed by 110° GA. The worst GA was 70°. Treatment time was substantially increased by the shaping strategy, approximately doubling delivery time. CONCLUSIONS Routine use of DTI pyramidal tractography might be important to fine-tune GK-T planning. DTI tractography, as well as anisotropy showing the VIM, promises to improve Gamma Knife functional procedures. They allow for a more objective definition of dose constraints to the IC and targeting. DTI pyramidal tractography introduced into the treatment planning may reduce the incidence of motor complications and improve efficacy. This needs to be validated in a large clinical series.


Assuntos
Encefalopatias/diagnóstico por imagem , Encefalopatias/radioterapia , Imagem de Tensor de Difusão , Radiocirurgia/métodos , Tálamo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...