Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Animals (Basel) ; 14(4)2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38396601

RESUMO

Peritoneopericardial diaphragmatic hernia (PPDH) is an opening between the pericardial sac and the pleuroperitoneal membrane. Pneumopericardium is an infrequent complication of PPDH. This condition is a serious circumstance in which free gas accumulates in the pericardial sac. The present report describes the occurrence of pneumopericardium and pericardial effusion after elective ovariectomy in a dog affected by PPDH. The presence of an umbilical and diaphragmatic hernia was highlighted during ovariectomy, and a pneumopericardium was seen during an X-ray exam. At the time of admission to the hospital, the dog was asymptomatic. The diagnosis was performed by X-ray and ultrasonographic exams. Computed tomography examination confirmed the diagnosis and directed for a surgical approach of the congenital defect. Surgery resulted in resolution of PPDH and of pneumopericardium.

2.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37846769

RESUMO

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Criocirurgia/métodos , Itália/epidemiologia , Sistema de Registros , Ablação por Cateter/métodos , Recidiva
3.
Artigo em Inglês | MEDLINE | ID: mdl-37775727

RESUMO

BACKGROUND: Criteria such as electrograms voltage or late potentials have been largely utilized in the past to help identify areas of substrate maps that are within the ventricular tachycardia (VT) isthmus; yet their specificity and positive predictive value are quite low. The Lumipoint fractionation tool of the Rhythmia system illuminates regions with fractionated electrograms irrespective of their timing and annotation. We aimed to ascertain whether the use of this tool can rapidly identify areas within VT isthmuses from substrate maps. METHODS: Thirty patients with structural cardiomyopathy in whom a complete right ventricular-paced substrate map and a full reconstruction of the diastolic isthmus during VT could be obtained were enrolled. The VT isthmus border was projected on each substrate map to verify whether the areas illuminated by Lumipoint fell within those borders. The behavior of the electrograms detected at the illuminated areas of the substrate maps was studied during a right ventricular drive train and extra stimulus protocol: if the near field potentials showed a delayed conduction after a single extra stimulus, defined as a minimum of 10 ms increase of the time interval between the far field and the near field activation measured during the drive train, the electrogram was said to have a "decremental" behavior. RESULTS: The logistic analysis showed that areas with fractionated electrograms illuminated by the Lumipoint software and showing the greatest decremental behavior fell within the VT isthmus borders (OR = 1.66, CI: 1.41-1.75, p<0.001; OR=1.57 CI: 1.32-1.72, p<0.001, respectively) with a sensitivity, specificity, and positive predictive value of 87%, 96%, and 97%, respectively. CONCLUSIONS: Fractionated electrograms illuminated by the automated Lumipoint software on right ventricular-paced substrate maps showing the greatest decremental behavior fall within the VT isthmus borders with a probability of 0.97, irrespective of their timing, annotation, or voltage, without any need for subjective assessment of their involvement in slow conduction areas.

5.
Appl Spectrosc ; 77(7): 764-773, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37278152

RESUMO

Ice cream is a complex product containing four different phases that affect its microstructure. Viscosity is a critical ice cream quality parameter that is typically measured using off-line methodologies, such as rheometry. In-line viscosity measurements allow continuous and instant analysis compared to off-line methodologies, yet they still constitute a challenge. This work focused on the preliminary study of the potential application of near-infrared (NIR) and Raman spectroscopy as analytical tools to assess the viscosity of ice cream mixes. Historically, partial least squares regression (PLSR) is a standard algorithm used for analysis of spectral data and in the development of predictive models. This methodology was implemented over a range of viscosity values, obtained by varying the ice cream fat content and homogenization conditions. Individual PLSR models showed some predictive ability and better performance compared to the integrated model obtained by data fusion. Lower prediction errors and higher coefficients of determination were obtained for NIR, making this technique more suitable based on model performance. However, other considerations should be accounted during the selection of the best method, such as implementation limitations. This study offers a preliminary comparison of the spectroscopic methods for quantitative analysis of viscosity of aged ice cream mixes and a starting point for an in-situ application study.

6.
J Pers Med ; 12(12)2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36556203

RESUMO

Purpose: The present study reports the preliminary outcomes in terms of adverse events and quality of life in the first 100 patients treated with 1.5T MR-guided daily-adaptive stereotactic body radiotherapy for prostate cancer. Methods: From October 2019 to December 2020, 100 patients, enrolled in a prospective study, received MR-guided SBRT for prostate cancer. Rectal spacer insertion was optional and administered in 37 patients. In total, 32 patients received androgen deprivation therapy in accordance with international guidelines. A prospective collection of data regarding toxicity and quality of life was performed. Results: The median age was 71 years (range, 52-84). The median total dose delivered was 35 Gy (35-36.25 Gy) in five sessions, either on alternate days (n = 25) or consecutive days (n = 75). For acute toxicity, we recorded: seven cases of acute G2 urinary pain and four cases of G2 gastrointestinal events. The median follow-up was 12 months (3-20), recording three late G2 urinary events and one G3 case, consisting of a patient who required a TURP 8 months after the treatment. For gastrointestinal toxicity, we observed 3 G ≥ 2 GI events, including one patient who received argon laser therapy for radiation-induced proctitis. Up to the last follow-up, all patients are alive and with no evidence of biochemical relapse, except for an M1 low-volume patient in distant progression two months after radiotherapy. QoL evaluation reported a substantial resolution of any discomfort within the second follow-up after radiotherapy, with the only exception being sexual items. Notably, after one year, global health items were improved compared to the baseline assessment. Conclusions: This study reports very promising outcomes in terms of adverse events and QoL, supporting the role of 1.5T MR-guided SBRT for prostate cancer. To date, this series is one of the first and largest available in the literature. Long-term results are warranted.

7.
Front Cardiovasc Med ; 9: 985182, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439999

RESUMO

Introduction: Unrecognized incomplete pulmonary vein (PV) isolation during the index procedure, can be a major cause of clinical recurrences of atrial fibrillation (AF) after cryoballoon (CB) ablation. We aimed to characterize the extension of the lesions produced by CB ablation and to assess the value of using an ultra-high resolution electroanatomic mapping (UHDM) system to detect incomplete CB lesions. Materials and methods: Twenty-nine consecutive patients from the CHARISMA registry undergoing AF ablation at four Italian centers were prospectively evaluated. The Rhythmia™ mapping system and the Orion™ (Boston Scientific) mapping catheter were used to systematically map the left atrium and PVs before and after cryoablation. Results: A total of 116 PVs were targeted and isolated. Quantitative assessment of the lesions revealed a significant reduction of the antral surface area of the PV, resulting in an ablated area of 5.7 ± 0.7 cm2 and 5.1 ± 0.8 cm2 for the left PV pair and right PV pair, respectively (p = 0.0068). The mean posterior wall (PW) area was 22.9 ± 2 cm2 and, following PV isolation, 44.8 ± 6% of the PW area was ablated. After CB ablation, complete isolation of each PV was documented by the POLARMap™ catheter in all patients. By contrast, confirmatory UHDM and the Lumipoint™ tool unveiled PV signals in 1 out of 114 of the PVs (0.9%). Over 30-day follow-up, no major procedure-related adverse events were reported. After a mean follow-up of 333 days, 89.7% of patients were free from arrhythmia recurrence. Conclusion: The lesion extension achieved by the new CB ablation system involved the PV antrum, with less than 50% of the PW remaining untouched. The new system, with short tip and circular mapping catheter, failed to achieve PV isolation in only 0.9% of all PVs treated. Clinical trial registration: [http://clinicaltrials.gov/], identifier [NCT03793998].

8.
Int J Mol Sci ; 23(15)2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35955601

RESUMO

In this work, an innovative model is proposed as a design tool to predict both the inner and outer radii in rolled structures based on polydimethylsiloxane bilayers. The model represents an improvement of Timoshenko's formula taking into account the friction arising from contacts between layers arising from rolling by more than one turn, hence broadening its application field towards materials based on elastomeric bilayers capable of large deformations. The fabricated structures were also provided with surface topographical features that would make them potentially usable in different application scenarios, including cell/tissue engineering ones. The bilayer design parameters were varied, such as the initial strain (from 20 to 60%) and the bilayer thickness (from 373 to 93 µm). The model matched experimental data on the inner and outer radii nicely, especially when a high friction condition was implemented in the model, particularly reducing the error below 2% for the outer diameter while varying the strain. The model outperformed the current literature, where self-penetration is not excluded, and a single value of the radius of spontaneous rolling is used to describe multiple rolls. A complex 3D bioinspired hierarchical elastomeric microstructure made of seven spirals arranged like a hexagon inscribed in a circumference, similar to typical biological architectures (e.g., myofibrils within a sarcolemma), was also developed. In this case also, the model effectively predicted the spirals' features (error smaller than 18%), opening interesting application scenarios in the modeling and fabrication of bioinspired materials.


Assuntos
Materiais Biomiméticos , Materiais Biomiméticos/química
9.
J Cardiovasc Electrophysiol ; 33(7): 1587-1589, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35557022

RESUMO

INTRODUCTION: A new dielectric-based method (KODEX-EPD mapping system, EPD Solutions, a Philips company) for measuring tissue thickness at the catheter-tissue interface has recently been developed. We reported preliminarydata on real-time catheter-based measuring myocardial wall thickness in vivo, during typical atrial flutter radio frequency ablation. METHODS AND RESULTS: The study population consisted of 12 consecutive patients, suffering from symptomatic paroxysmal or persistent cavo-tricuspid isthmus dependent, counter clockwise and clockwise AFL, under going a first catheter ablation between April 2021 and November 2021. The new KODEX-EPD function, Wall Viever, was used to calculate atrialwall thickness. The atrial wall thickness was significantly higher closeto the tricuspid annulus than close to the inferior vena cava (3.6 ± 0.5 mm vs 2.4 ± 0.3 mm, p < .001) and a trend towards a progressive decrease of atrial wall thickness was observed moving the mapping catheter from the tricuspidvalve to the inferior vena cava. CONCLUSIONS: Thenew KODEX-EPD function, Wall Viever, allowed us to assess atrial wall thickness during atrial flutter radio frequency ablation.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Humanos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
10.
J Cardiovasc Electrophysiol ; 33(7): 1414-1424, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35524404

RESUMO

INTRODUCTION: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system. METHODS: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity. The Lumipoint™ (Boston Scientific) map-analysis tool was used sequentially on each PV component. The ablation endpoint was PV isolation (PVI) and electrical quiescence in the antral region. RESULTS: Fifty-eight cases of AF ablation were analyzed. A total of 86 PVGs in 34 (58.6%) patients and 44 RAPs in 34 patients (58.6%) were found. In 16 (27.6%) cases, we found at least one RAP in patients with complete absence of PV conduction. RAPs showed a lower mean voltage than PVG (0.3 ± 0.2 mV vs. 0.7 ± 0.5 mV, p < .0001), whereas the mean number of electrogram peaks was higher (8.4 ± 1.4 vs. 3.2 ± 1.5, p < .0001). The percentage of patients in whom RAPs were detected through Lumipoint™ was higher than through propagation map analysis (58.6% vs. 36.2%, p = .025). Acute procedural success was 100%, with all PVs successfully isolated and RAPs completely abolished in all study patients. During a mean follow-up of 453 ± 133 days, 6 patients (10.3%) suffered an AF/AT recurrence. CONCLUSION: Local vulnerabilities in antral lesion sets were easily discernible by means of the UHDM system in both de novo and redo patients when no PV conduction was present.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
11.
Front Oncol ; 12: 858740, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35494082

RESUMO

Background: Prostate re-irradiation is an attractive treatment option in the case of local relapse after previous radiotherapy, either in the definitive or in the post-operative setting. In this scenario, the introduction of MR-linacs may represent a helpful tool to improve the accuracy and precision of the treatment. Methods: This study reports the preliminary data of a cohort of 22 patients treated with 1.5T MR-Linacs for prostate or prostate bed re-irradiation. Toxicity was prospectively assessed and collected according to CTCAE v5.0. Survival endpoints were measured using Kaplan-Meier method. Results: From October 2019 to October 2021, 22 patients received 1.5T MR-guided stereotactic body radiotherapy for prostate or prostate-bed re-irradiation. In 12 cases SBRT was delivered to the prostate, in 10 to the prostate bed. The median time to re-RT was 72 months (range, 12-1460). SBRT was delivered concurrently with ADT in 4 cases. Acute toxicity was: for GU G1 in 11/22 and G2 in 4/22; for GI G1 in 7/22, G2 in 4/22. With a median follow-up of 8 months (3-21), late G1 and G2 GU events were respectively 11/22 and 4/22. Regarding GI toxicity, G1 were 6/22, while G2 3/22. No acute/late G≥3 GI/GU events occurred. All patients are alive. The median PSA-nadir was 0.49 ng/ml (0.08-5.26 ng/ml), for 1-year BRFS and DPFS rates of 85.9%. Twenty patients remained free from ADT with 1-year ADT-free survival rates of 91.3%. Conclusions: Our experience supports the use of MR-linacs for prostate or prostate bed re-irradiation as a feasible and safe treatment option with minimal toxicity and encouraging results in terms of clinical outcomes.

12.
J Interv Card Electrophysiol ; 65(1): 97-102, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35378611

RESUMO

BACKGROUND: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. We evaluated the feasibility, efficacy and safety of the vHPSD ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). METHODS: This prospective non-randomized study enrolled 28 consecutive patients (FAST Group) with typical AFL undergoing CTI ablation. The vHPSD ablation was performed applying 90 W, for 4 s, with an irrigation of 8 ml/min. Thirty consecutive patients who, previously, underwent CTI ablation by means of a contact force surrounding flow catheter guided by ablation index (500) served as control group (AI Group). RESULTS: In the FAST Group, the mean CTI length was 29 ± 6 mm, and the mean number of RF tags was 20 ± 9. The CTI bidirectional "first pass" block was reached in 25 (89%) patients. There were no major procedural complications. After a mean follow-up of 6 ± 2 months, one (3.5%) patient had arrhythmia recurrence. The vHPSD ablation was as effective as AI-guided ablation in achieving acute CTI block (rate of first pass 89% vs 93%, p = 0.59), with a shorter RF time (88 ± 40 s vs 492 ± 269 s, p < 0.001) and similar procedure (30 ± 4 min vs 34 ± 10 min, p = 0.5) and fluoroscopy time (103 ± 29 vs 108 ± 52 s, p = 0.7). At 8 months, the freedom from AFL recurrence was 96% in the FAST group and 97% in the AI group. CONCLUSIONS: Our preliminary data show that the vHPSD ablation represents an effective and safe ablation strategy to achieve bidirectional block for the treatment of typical AFL.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/cirurgia , Humanos , Estudos Prospectivos , Temperatura , Resultado do Tratamento
13.
Radiother Oncol ; 169: 86-89, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35218788

RESUMO

Spasticity is a clinical condition secondary to central nervous system damage, which impairs patients' mobility and quality of life. Stereotactic radiosurgery (SRS) to the spinal roots responsible of the spasms might represent a non-invasive therapy. The present are the preliminary results of the first clinical use of this novel technique.


Assuntos
Neoplasias do Sistema Nervoso Central , Radiocirurgia , Neoplasias do Sistema Nervoso Central/radioterapia , Humanos , Qualidade de Vida , Radiocirurgia/métodos , Resultado do Tratamento
14.
Adv Radiat Oncol ; 7(3): 100865, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35198836

RESUMO

PURPOSE: Adaptive stereotactic body radiation therapy (SBRT) for prostate cancer (PC) by the 1.5 T MR-linac currently requires online planning by an expert user. A fully automated and user-independent solution to adaptive planning (mCycle) of PC-SBRT was compared with user's plans for the 1.5 T MR-linac. METHODS AND MATERIALS: Fifty adapted plans on daily magnetic resonance imaging scans for 10 patients with PC treated by 35 Gy (prescription dose [Dp]) in 5 fractions were reoptimized offline from scratch, both by an expert planner (manual) and by mCycle. Manual plans consisted of multicriterial optimization (MCO) of the fluence map plus manual tweaking in segmentation, whereas in mCycle plans, the objectives were sequentially optimized by MCO according to an a-priori assigned priority list. The main criteria for planning approval were a dose ≥95% of the Dp to at least 95% of the planning target volume (PTV), V33.2 (PTV) ≥ 95%, a dose less than the Dp to the hottest cubic centimeter (V35 ≤ 1 cm3) of rectum, bladder, penile bulb, and urethral planning risk volume (ie, urethra plus 3 mm isotropically), and V32 ≤ 5%, V28 ≤ 10%, and V18 ≤ 35% to the rectum. Such dose-volume metrics, plus some efficiency and deliverability metrics, were used for the comparison of mCycle versus manual plans. RESULTS: mCycle plans improved target dose coverage, with V33.2 (PTV) passing on average (±1 SD) from 95.7% (±1.0%) for manual plans to 97.5% (±1.3%) for mCycle plans (P < .001), and rectal dose sparing, with significantly reduced V32, V28, and V18 (P ≤ .004). Although at an equivalent number of segments, mCycle plans consumed moderately more monitor units (+17%) and delivery time (+9%) (P < .001), whereas they were generally faster (-19%) in terms of optimization times (P < .019). No significant differences were found for the passing rates of locally normalized γ (3 mm, 3%) (P = .059) and γ (2 mm, 2%) (P = .432) deliverability metrics. CONCLUSIONS: In the offline setting, mCycle proved to be a trustable solution for automated planning of PC-SBRT on the 1.5 T MR-linac. mCycle integration in the online workflow will free the user from the challenging online-optimization task.

15.
Heart Vessels ; 37(1): 115-120, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34240266

RESUMO

Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX-EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system. In a retrospective, single center study, we enrolled 34 consecutive patients with paroxysmal AF divided in two groups: 17 patients in Conventional Group underwent the procedure under fluoroscopy guidance before the new system introduction, while 17 patient in KODEX-EPD Group underwent the procedure under fluoroscopy and KODEX-EPD imaging system guidance. There were no differences in any clinical and anatomical characteristics between the two study groups. Overall procedure time was comparable between the two groups (69 [IQR 63-98] min in Conventional Group vs. 65 [IQR 58-74] min in KODEX-EPD Group, p = 0.16), while fluoroscopy time (8 [IQR 5-9] min vs. 11 [IQR 9-12] min, p = 0.014) and dye use (35 [IQR 28-45] ml vs. 70 [IQR 57-83] ml, p < 0.001) were significantly lower in the KODEX-EPD Group. No 30-day complications were observed. At 12-month follow-up 7/37 (19%) patients had an atrial arrhythmias recurrence, without any difference between the two study groups (17.6% vs. 23.5%, p = 0.68). The use of a new dielectric imaging system allowed a significantly reduction in radiation exposure and dye use during CB ablation in patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Meios de Contraste , Fluoroscopia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
16.
J Interv Card Electrophysiol ; 64(3): 641-648, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34853986

RESUMO

PURPOSE: A new cryoballoon (CB) technology (POLARx™; Boston Scientific) for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF) has recently been introduced. The aim of this study was to evaluate procedural and biophysical parameters resulting in acute PV isolation when using this new CB. METHODS: We assessed the first 69 consecutive patients indicated for AF ablation who underwent PV isolation by means of a novel CB system. Procedural metrics were prospectively recorded. RESULTS: A total of 274 PVs were targeted in 69 patients. PV isolation was achieved in all patients by means of cryoablation alone. The median time to isolation (TTI) was 44 [31-68] s (median temperature at TTI = - 49 [- 53 to - 41] °C). The median duration of CB ablation was 180 [180 to 240] s. The median nadir temperature was - 56.0 [- 61 to - 52] °C, and the median thaw time to 0 °C was 18 [15-21] s. The median grade of PV occlusion was 4 [3 to 4]. On the basis of ROC analysis, we defined the following cut-off values for acute PV isolation: - 56 °C for nadir temperature (sensitivity = 73.3%, specificity = 64.6%, AUC = 0.716; positive predictive value = 88.1%), 30 s for TTT (60.2%, 53.3%, 0.578; 79.7%), thaw time > 17 s (65.3%, 70.0%, 0.709; 86.9%), and grade of PV occlusion = 4 (79.4%, 66.7%, 0.738; 88.5%). No major procedure-related adverse events were observed at 30-day post-procedure. CONCLUSIONS: The new POLARx™ CB appears to be effective and safe. A nadir temperature of - 56 °C, a thaw time to 0 °C ≥ 17 s, and complete PV occlusion were the best predictors of acute PV isolation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/Identifier : NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Sistema de Registros , Resultado do Tratamento
17.
J Neurol ; 269(5): 2610-2618, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34676446

RESUMO

INTRODUCTION: Little is known about metabolic changes in progressive supranuclear palsy. Goals of the present study are to: (1) investigate whether early progressive supranuclear palsy is associated with changes in energy expenditure, body composition and dietary intake compared with Parkinson's disease and healthy controls; (2) assess the accuracy of the Harris-Benedict equation to predict measured rest energy expenditure in progressive supranuclear palsy; (3) verify differences according to sex, phenotypes, disease severity and presence of dysphagia in progressive supranuclear palsy. METHODS: Twenty-one progressive supranuclear palsy, 41 Parkinson's disease and nine healthy controls were included. Rest energy expenditure was assessed with indirect calorimeter, body composition with bio-impedance analysis and physical activity and dietary intake were estimated with a validated frequency questionnaire. Parametric testing was used to analyze differences between groups. RESULTS: Progressive supranuclear palsy showed reduced total daily energy expenditure and physical activity compared to both other cohorts (p < 0.001) and a tendency toward lower fat-free mass compared to Parkinson's disease (p > 0.05). Limited accuracy was shown for the Harris-Benedict equation (accurate prediction frequency < 60%). Greater disease severity was associated with lower rest energy expenditure (p = 0.030), fat-free mass (p = 0.026) and muscle mass (p = 0.029). CONCLUSION: Greater disease severity is associated with reduction in rest energy expenditure likely due to the reduction in lean mass and muscle mass. Such data may pave the way to clinical trials evaluating the efficacy of muscle-targeted nutritional support and physical therapy in preserving muscle mass and improving motor performances in progressive supranuclear palsy at early stages.


Assuntos
Doença de Parkinson , Paralisia Supranuclear Progressiva , Composição Corporal , Metabolismo Energético , Comportamento Alimentar , Humanos , Doença de Parkinson/complicações , Doença de Parkinson/metabolismo , Paralisia Supranuclear Progressiva/complicações
18.
Breast Care (Basel) ; 16(4): 358-367, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34602941

RESUMO

INTRODUCTION: The aim of the present study was to estimate the impact of the addition of internal mammary chain (IMC) irradiation in node-positive left-sided breast cancer (BC) patients undergoing regional nodal irradiation (RNI) and comparatively evaluate excess relative and absolute risks of radiation-induced lung cancer/BC and ischaemic heart disease for intensity-modulated radiotherapy (IMRT) versus 3D conformal radiotherapy (3D-CRT). METHODS: Four treatment plans were created (3D-CRT and IMRT -/+ IMC) for each of the 10 evaluated patients, and estimates of excess relative risk (ERR) and 10-year excess absolute risk (EAR) were calculated for radiation-induced lung cancer/BC and coronary events using linear, linear-exponential and plateau models. RESULTS: The addition of IMC irradiation to RNI significantly increased the dose exposure of the heart, lung and contralateral breast using both techniques, increasing ERR for secondary lung cancer (58 vs. 44%, p = 0.002), contralateral BC (49 vs. 31%, p = 0.002) and ischaemic heart disease (41 vs. 27%, p = 0.002, IMRT plans). IMRT significantly reduced the mean cardiac dose and mean lung dose as compared to 3D-CRT, decreasing ERR for major coronary events (64% 3D-CRT vs. 41% IMRT, p = 0.002) and ERR for secondary lung cancer (75 vs. 58%, p = 0.004) in IMC irradiation, without a significant impact on secondary contralateral BC risks. CONCLUSION: Although IMC irradiation has been shown to increase survival rates in node-positive BC patients, it increased dose exposure of organs at risk in left-sided BC, resulting in significantly increased risks for secondary lung cancer/contralateral BC and ischaemic heart disease. In this setting, the adoption of IMRT seems advantageous when compared to 3D-CRT.

19.
Radiat Oncol ; 16(1): 197, 2021 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-34627313

RESUMO

BACKGROUND: Approximately one third of cancer patients will develop spinal metastases, that can be associated with back pain, neurological symptoms and deterioration in performance status. Stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) have been offered in clinical practice mainly for the management of oligometastatic and oligoprogressive patients, allowing the prescription of high total dose delivered in one or few sessions to small target volumes, minimizing the dose exposure of normal tissues. Due to the high delivered doses and the proximity of critical organs at risk (OAR) such as the spinal cord, the correct definition of the treatment volume becomes even more important in SBRT treatment, thus making it necessary to standardize the method of target definition and contouring, through the adoption of specific guidelines and specific automatic contouring tools. An automatic target contouring system for spine SBRT is useful to reduce inter-observer differences in target definition. In this study, an automatic contouring tool was evaluated. METHODS: Simulation CT scans and MRI data of 20 patients with spinal metastases were evaluated. To evaluate the advantage of the automatic target contouring tool (Elements SmartBrush Spine), which uses the identification of different densities within the target vertebra, we evaluated the agreement of the contours of 20 spinal target (2 cervical, 9 dorsal and 9 lumbar column), outlined by three independent observers using the automatic tool compared to the contours obtained manually, and measured by DICE similarity coefficient. RESULTS: The agreement of GTV contours outlined by independent operators was superior with the use of the automatic contour tool compared to manually outlined contours (mean DICE coefficient 0.75 vs 0.57, p = 0.048). CONCLUSIONS: The dedicated contouring tool allows greater precision and reduction of inter-observer differences in the delineation of the target in SBRT spines. Thus, the evaluated system could be useful in the setting of spinal SBRT to reduce uncertainties of contouring increasing the level of precision on target delivered doses.


Assuntos
Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Humanos , Variações Dependentes do Observador , Órgãos em Risco , Radiocirurgia/efeitos adversos , Neoplasias da Coluna Vertebral/patologia , Carga Tumoral
20.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...