Int J Lab Hematol ; 43(5): 1229-1236, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33856126

RESUMO

INTRODUCTION: To perform comparability of instruments, the laboratory can select patient samples spanning the reportable range or can use plasma sets from commercial suppliers. We evaluated ExpertCor Routine (ECR) plasma set (Stago), a set of frozen plasmas enabling to verify the agreement between different coagulation analysers. Additionally, we evaluated whether the concept of transference of the reference range is acceptable between instruments, once comparability between the instruments is approved. METHODS: Patient samples and the ECR plasma set were evaluated for method comparison for prothrombin time, activated partial thromboplastin time and fibrinogen on five instruments. Results of one instrument were compared to the mean of all analysers by Passing-Bablok regression and Bland-Altman analysis. Reference ranges were checked on all instruments. RESULTS: The %mean difference was ≤5% and ≤3.7% for all analyser/parameter combinations, for ECR and patient sample data sets, respectively. All predefined criteria to fulfil good comparability between instruments were met. The between-instrument comparison with the ECR plasma set and the patient samples was equal for PT, INR and fibrinogen. After demonstrating comparability between instruments by either of the two plasma sample sets, reference ranges can be used interchangeably between identical instruments. CONCLUSION: Instrument-to-instrument reproducibility showed comparable results using a data set obtained with patient samples or a commercial plasma set. Once comparability between instruments is confirmed, defined reference ranges can be transferred from one instrument to the other instrument without additional testing. The ECR plasma set is a good alternative to the use of local patient samples to evaluate instrument comparability.


Assuntos
Testes de Coagulação Sanguínea/instrumentação , Plasma , Congelamento , Humanos , Plasma/química , Valores de Referência , Reprodutibilidade dos Testes
2.
Clin Exp Rheumatol ; 38(2): 212-219, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31287411

RESUMO

OBJECTIVES: Today, the contribution of myositis-specific autoantibodies (MSA) in the diagnostic workup of idiopathic inflammatory myopathies (IIM) is on the rise. The aim of this study was to document MSA frequency as detected by lineblot in a set of consecutive MSA requests and to correlate the results with clinical diagnosis, IIM subtype and indirect immunofluorescence (IIF) findings. Additionally, a comparison between two lineblots was performed. METHODS: A total of 118 consecutive samples of patients with suspicion of IIM were analysed on IIF and two lineblots. A total of 107 patients with autoimmune rheumatic diseases served as controls. RESULTS: MSA were detected in 55% of IIM patients (n=31) and 7.9% (n=12) of patients without clinical diagnosis of IIM or myositis overlap syndrome. All the IIM patients had a MSA-compatible clinical subtype. There was no to fair agreement between both lineblots for the individual antibodies, with most discrepancies observed for anti-TIF1γ (κ=-0.021), anti-SRP (κ=-0.006) and anti-SAE (κ=0.395). Differences between both assays were mostly observed in the non-IIM patients, also showing signi cantly lower blot signal intensities compared to IIM patients (p=0.0013). MSA in the non-IIM patients frequently showed an incompatible IIF pattern. CONCLUSIONS: Lineblot seems to be an interesting tool for MSA detection in a clinical context, allowing the identification of clinical subtypes. However, considerable caution must be exercised in interpreting the results in case of low positive MSA signal intensity, discordant lineblot results and/or an incompatible IIF pattern.


Assuntos
Autoanticorpos/imunologia , Miosite/diagnóstico , Miosite/imunologia , Autoanticorpos/sangue , Doenças Autoimunes , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Síndrome
3.
Am J Clin Pathol ; 147(6): 611-622, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575180

RESUMO

OBJECTIVES: Free light chain (FLC) measurement gained a lot of interest for diagnostic workup of monoclonal gammopathy. METHODS: We evaluated the performance of turbidimetric polyclonal Freelite (The Binding Site, Birmingham, UK) assays on Cobas 6000 (Roche Diagnostics, Rotkreuz, Switzerland) and nephelometric monoclonal N Latex (Siemens Healthcare Diagnostics, Marburg, Germany) assays on BN ProSpec (Dade Behring, Deerfield, IL) vs established nephelometric Freelite assays on BN ProSpec. RESULTS: Analytical performance was acceptable. Method comparison (n = 118) showed significant proportional FLC differences for N Latex assays. However, good correlation and clinical concordance were shown. Recovery study in the low concentration range demonstrated consistent over- and underrecovery for Freelite reagents, hampering future research on prognostic value of suppressed noninvolved FLC. Antigen excess detection was successful for κ FLC in three-fourths of cases with Freelite reagents and in all cases with N Latex reagents. However, the latter resulted in underestimated κ FLC concentrations. CONCLUSIONS: FLC analysis requires continuous awareness of analytical limitations. Monitoring of disease response requires FLC analysis on the same platform using the same reagents.


Assuntos
Cadeias Leves de Imunoglobulina/sangue , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Nefelometria e Turbidimetria/métodos , Paraproteinemias/diagnóstico , Anticorpos Monoclonais/imunologia , Humanos , Cadeias Leves de Imunoglobulina/imunologia , Cadeias kappa de Imunoglobulina/imunologia , Cadeias lambda de Imunoglobulina/imunologia , Paraproteinemias/imunologia , Prognóstico , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
5.
Clin Chem Lab Med ; 55(10): 1564-1573, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28222018

RESUMO

BACKGROUND: We evaluated the analytical performance of six different faecal calprotectin immunoassays together with their diagnostic accuracy in the discrimination between functional and organic bowel disorders. METHODS: The faecal samples were obtained from inflammatory bowel disease patients (n=27) at the time of diagnosis [Crohn's disease (n=15), colitis ulcerosa (n=12)], gastroenterologic disease control patients (n=52) and rheumatologic disease control patients (n=26). All individuals included in the study underwent a concurrent ileocolonoscopy. Analytical performance (imprecision, accuracy, carry-over, correlation and agreement) and diagnostic accuracy (sensitivity, specificity, likelihood ratios) of the different assays were evaluated. RESULTS: All methods demonstrated good analytical performance, but within-run and total imprecision varied depending on the assay methodology used. Using Passing Bablok and Bland-Altman analyses, low quantitative agreement was observed between the assays. All assays showed excellent diagnostic accuracy, with areas under the receiver operating characteristic curves (ROC) ranging from 0.974 to 0.998. The AUCs were not significantly different between assays (p>0.05). Diagnostic sensitivity at the cut-off at a fixed specificity of 75% ranged from 95.2% to 100%. Introduction of multiple result intervals increased the clinical interpretation of all the assays. CONCLUSIONS: Analytical and diagnostic performance of the evaluated faecal calprotectin assays is good, but numerical values differ substantially between the assays necessitating the use of different clinical cut-offs. Introduction of multiple result intervals aids in clinical decision-making.


Assuntos
Fezes/química , Imunoensaio , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Colonoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Adulto Jovem
6.
Clin Chem Lab Med ; 55(9): 1435-1446, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28076305

RESUMO

BACKGROUND: We evaluated the (pre-)analytical and diagnostic performance of two automated fecal calprotectin (FC) immunoassays, Liaison® Calprotectin (Diasorin) on Liaison® XL and fCAL™ turbo (Bühlmann laboratories AG) on Cobas C501 (Roche Diagnostics), and compared it with our established Bühlmann ELISA method. METHODS: Our study comprised 229 consecutive patients with clinical suspicion of inflammatory bowel disease (IBD). RESULTS: All assay related stool extraction procedures showed excellent correlation with the established method, but the new stool extraction devices tend to give higher results as compared with stool weight methods. Both automated assays demonstrated good performance in terms of precision (CVt≤8.1%), accuracy (bias≤6.7%) and total error (≤16.4%). Method comparison with established enzyme linked immunosorbent assay (ELISA) showed good correlation (rs>0.925), but regression analysis showed significant proportional differences. Diagnostic performance characteristics with regard to diagnosis of IBD were good and in line with other reports. In addition, we were able to show that optimization of manufacturer's cut-off and moreover, the introduction of a gray zone resulted in a significant increase of post-test probability. CONCLUSIONS: In conclusion, the newly developed stool extraction device protocols showed acceptable and comparable performance to the stool weight method. Overall, the automated Liaison® Calprotectin and fCAL™ turbo assay showed good analytical and diagnostic performance for detection of IBD.


Assuntos
Fezes/química , Imunoensaio , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Feminino , Humanos , Imunoensaio/normas , Masculino , Pessoa de Meia-Idade , Adulto Jovem