7.
Perfusion ; 33(1): 16-24, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28766987

RESUMO

INTRODUCTION: Gaseous microemboli (GME) introduced during cardiac surgery are considered as a potential source of morbidity, which has driven the development of the first bubble counters. Two new generation bubble counters, introduced in the early 2000s, claim correct sizing and counting of GME. This in-vitro study aims to validate the accuracy of two bubble counters using monodisperse bubbles in a highly controlled setting at low GME concentrations. METHODS: Monodisperse GME with a radius of 43 µm were produced in a microfluidic chip. Directly after their formation, they were injected one-by-one into the BCC200 and the EDAC sensors. GME size and count, measured with the bubble counters, were optically verified using high-speed imaging. RESULTS: During best-case scenarios or low GME concentrations of GME with a size of 43 µm in radius in an in-vitro setup, the BCC200 overestimates GME size by a factor of 2 to 3 while the EDAC underestimates the average GME size by at least a factor of two. The BCC200 overestimates the GME concentration by approximately 20% while the EDAC overestimates the concentration by nearly one order of magnitude. Nevertheless, the calculated total GME volume is only over-predicted by a factor 2 since the EDAC underestimates the actual GME size. For the BCC200, the total GME volume was over-predicted by 25 times due to the over-estimation of GME size. CONCLUSIONS: The measured errors in the absolute sizing/counting of GME do not imply that all results obtained using the bubble counters are insignificant or invalid. A relative change in bubble size or bubble concentration can accurately be measured. However, care must be taken in the interpretation of the results and their absolute values. Moreover, the devices cannot be used interchangeably when reporting GME activity. Nevertheless, both devices can be used to study the relative air removal characteristics of CPB components or for the quantitative monitoring of GME production during CPB interventions.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/métodos , Embolia Aérea/etiologia , Desenho de Equipamento/métodos , Humanos
8.
Eur J Anaesthesiol ; 34(10): 688-694, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28834795

RESUMO

BACKGROUND: Induction of anaesthesia causes significant macrohaemodynamic changes, but little is known about its effects on the microcirculation. However, alterations in microvascular perfusion are known to be associated with impaired tissue oxygenation and organ dysfunction. Microvascular reactivity can be assessed with vascular occlusion testing, which evaluates the response of tissue oxygen saturation to transient ischaemia and reperfusion. OBJECTIVE: The aim of the current study was to evaluate the effects of an opioid-based anaesthesia induction on microvascular reactivity. We hypothesised that despite minimal blood pressure changes, microvascular function would be impaired. DESIGN: Prospective, observational study. SETTING: Single-centre, tertiary university teaching hospital, Belgium. PATIENTS: Thirty-five adult patients scheduled for elective coronary artery bypass grafting surgery. INTERVENTION: Microvascular reactivity was assessed before and 30 min after anaesthesia induction by means of vascular occlusion testing and near-infrared spectroscopy. MAIN OUTCOME MEASURES: Tissue oxygen saturations, desaturation rate, recovery time (time from release of cuff to the maximum value) and rate of recovery were determined. RESULTS: Data are expressed as median (minimum to maximum). Tissue oxygen saturation was higher after induction of anaesthesia [70 (54 to 78) vs. 73 (55 to 94)%, P = 0.015]. Oxygen consumption decreased after induction, appreciable by the higher minimum tissue oxygen saturation [45 (29 to 69) vs. 53 (28 to 81)%, P < 0.001] and the slower desaturation rate [11 (4 to 18) vs. 9 (5 to 16)% min, P < 0.001]. After induction of anaesthesia, recovery times were longer [40 (20 to 120) vs. 48 (24 to 356) s, P = 0.004] and the rate of recovery was lower [114 (12 to 497) vs. 80 (3 to 271)% min, P < 0.001]. CONCLUSION: After induction of anaesthesia, oxygen consumption was decreased. The longer recovery times and slower rates of recovery indicate impaired microvascular reactivity after induction of anaesthesia. TRIAL REGISTRATION: The research project was registered at ClinicalTrials.gov (NCT02034682).


Assuntos
Analgésicos Opioides/efeitos adversos , Anestesia/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Microcirculação/efeitos dos fármacos , Monitorização Intraoperatória/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Idoso , Anestesia/tendências , Procedimentos Cirúrgicos Cardíacos/tendências , Feminino , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Consumo de Oxigênio/efeitos dos fármacos , Consumo de Oxigênio/fisiologia , Estudos Prospectivos
9.
J Clin Pathol ; 69(9): 772-6, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26850632

RESUMO

AIMS: Human heart valves are prone to glycation, a fundamental process of ageing. The aim of this study was to establish the relationship between fructosamine formation and the mechanical properties of human aortic valves. METHODS: 67 patients (age: 76±8 years) diagnosed with an aortic valve stenosis, who underwent an aortic valve replacement were enrolled. Fructosamine and calcium concentrations in aortic valves were determined. Using a transthoracic Doppler echocardiography, aortic valve orifice area and transvalvular pressure gradients were measured. In a subgroup of 32 patients, the aortic valve orifice area was sufficient to carry out mechanical testing on a LFPlus Universal material tester. An in vitro removal of fructosamine of the valve was initiated using ATP-dependent fructosamine 3-kinase (FN3K). RESULTS: A significant correlation was found between the aortic valve fructosamine concentration and the calculated aortic valve orifice area: Y (aortic valve orifice area, mm(2))=1.050-0.228X (aortic valve fructosamine concentration, µmol/g valve) (r=-0.38). A significantly higher calcium concentration was measured in the aortic valves of diabetics in comparison with those of non-diabetics. A multiple regression analysis revealed that the presence of diabetes mellitus and aortic valve fructosamine concentration were the main predictors of the extensibility of the aortic valves. In the in vitro deglycation study, a significant lower aortic valve fructosamine concentration was detected after treatment with FN3K. This resulted in an increased flexibility of the aortic valves. CONCLUSIONS: Although no direct causativeness is proven with the presented results, which just show an association between fructosamine, the effect of FN3K and aortic valve stiffness, the present study points for the first time towards a possible additional role of the Amadori products in the biomechanical properties of ageing aortic valves.


Assuntos
Estenose da Valva Aórtica/metabolismo , Valva Aórtica/metabolismo , Frutosamina/metabolismo , Rigidez Vascular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Cálcio/metabolismo , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Fosfotransferases (Aceptor do Grupo Álcool)/farmacologia , Rigidez Vascular/efeitos dos fármacos
10.
Interact Cardiovasc Thorac Surg ; 16(6): 778-83, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23482374

RESUMO

OBJECTIVES: Many cardiac procedures using cardiopulmonary bypass (CPB) still require intraoperative transfusion. Retrograde autologous priming (RAP) has been introduced to decrease haemodilution and the blood transfusion rate. This study is designed to determine the influence or RAP on intraoperative haematocrit, transfusion and its clinical consequences. METHODS: The RAP effect was retrospectively studied in 753 patients during contemporary cardiac surgery, targeting a haematocrit of 25%. Multivariate linear regression analysis was performed to identify the independent factors influencing intraoperative haematocrit, transfusion rate and transfusion quantity. RESULTS: RAP was used in 498 patients and compared with 255 controls. RAP decreased the haemodilution level (nadir haematocrit 26.8 standard deviation [SD] 4.0% in RAP vs 25.8 SD 3.6% in controls; P = 0.001) and transfusion frequency (26.1 vs 33.3%, P = 0.04), despite smaller patients (body surface area [BSA] 1.86 SD 0.20 m(2) vs 1.91 SD 0.21 m(2) in RAP vs controls; P = 0.002) with lower preoperative haematocrit (38.9 SD 4.4% vs 40.5 SD 4.6%; P < 0.001). Optimal RAP volume was overall 475 ml (ROC area 0.55; 95% confidence interval [CI] 0.50-0.60; P = 0.04) and 375 ml in patients with BSA <1.7 m(2) (ROC area 0.63; 95% CI 0.54-0.73; P = 0.008) to decrease the transfusion incidence. Multivariate analysis revealed RAP volume as a significant determinant of nadir haematocrit (ß = 0.003, 95% CI 0.002-0.004, P < 0.001) and transfusion rate (odds ratio (OR) = 0.997, 95% CI 0.996-0.999, P < 0.001), independent of BSA, gender and preoperative haematocrit. CONCLUSIONS: Retrograde autologous priming is an effective adjunct to decrease the blood transfusion rate, coping with the CPB-related haemodilution and its adverse clinical effects. A RAP volume individualized to each patient offers most benefit as part of a multidisciplinary blood conservation approach.


Assuntos
Transfusão de Sangue Autóloga , Procedimentos Cirúrgicos Cardíacos , Hemodiluição , Idoso , Área Sob a Curva , Transfusão de Sangue Autóloga/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar , Distribuição de Qui-Quadrado , Feminino , Hematócrito , Hemodiluição/efeitos adversos , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
11.
Interact Cardiovasc Thorac Surg ; 10(6): 995-1001, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20197351

RESUMO

OBJECTIVES: Gaseous microemboli (GME) are a cause of neurocognitive deficit postcardiac surgery with cardiopulmonary bypass. However, the measurement of microbubbles during cardiopulmonary bypass is not easy, because blood is an opaque fluid and contains microparticles. Recently, two new microbubble counters, the Gampt BC200 and the emboli detection and classification (EDAC) quantifier, were developed for use during cardiac surgery. The accuracy of both devices was validated against industrial standards. METHODS: A clear blood analogue (30%/70% glycerol-water) was pumped, by means of a rollerpump out of a partially filled arterial line screen filter with a nominal pore size of 20 microm. Downstream the pump, all test sensors and an optical cuvette, were inserted in a vertically mounted 3/8 inch tubing. Measurements were taken at flows of 405, 1080, 3000 and 6000 ml/min. Backlight shadowgraphy and optical counting were used as industrial reference techniques for measuring size and counts. RESULTS: On average the EDAC quantifier underestimates average bubble diameter by 35+/-1%, 13+/-8%, 71+/-7% and 33+/-4% at 405, 1080, 3000 and 6000 ml/min, respectively. The Gampt BC200 has good sizing agreement at 1080 ml/min (+5+/-17%) and 3000 ml/min (+33+/-6%) but overestimates average diameter by 220+/-40% and 295+/-49% at 405 and 6000 ml/min, respectively. Both devices only partially count the number of microbubbles at higher flows. At 3 l/min the EDAC counts 38%, the Gampt 18% of total counts and at 6 l/min both the EDAC and Gampt only count 3% of total counts. CONCLUSIONS: Both the EDAC and Gampt can be used in a clinical setting for monitoring basal GME production. However, both devices have some major limitations when used for studying 'worst case' scenarios. One should take great caution when correlating measured data with neurocognitive outcome. Finally, results obtained by one device in a first study cannot be compared nor exchanged with results from the other device in a second study.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar/efeitos adversos , Embolia Aérea/diagnóstico por imagem , Microbolhas , Monitorização Intraoperatória/métodos , Ultrassonografia Doppler de Pulso , Velocidade do Fluxo Sanguíneo , Embolia Aérea/etiologia , Embolia Aérea/fisiopatologia , Desenho de Equipamento , Humanos , Lasers , Teste de Materiais , Monitorização Intraoperatória/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Espalhamento de Radiação , Ultrassonografia Doppler de Pulso/instrumentação