1.
Pacing Clin Electrophysiol ; 22(8): 1234-9, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10461302

RESUMO

This study compares LV performance during high right ventricular septal (RVS) and apical (RVA) pacing in patients with LV dysfunction who underwent His-bundle ablation for chronic AF. We inserted a passive fixation pacing electrode into the RVA and an active fixation electrode in the RVS. A dual chamber, rate responsive pulse generator stimulated the RVA through the ventricular port and the RVS via the atrial port. Patients were randomized to initial RVA (VVIR) or RVS (AAIR) pacing for 2 months. The pacing site was reversed during the next 2 months. At the 2 and 4 month follow-up visit, each patient underwent a transthoracic echocardiographical study and a rest/exercise first pass radionuclide ventriculogram. We studied nine men and three women (mean age of 68 +/- 7 years) with congestive heart failure functional Class (NYHA Classification): I (3 patients), II (7 patients), and III (2 patients). The QRS duration was shorter during RVS stimulation (158 +/- 10 vs 170 +/- 11 ms, P < 0.001). Chronic capture threshold and lead impedance did not significantly differ. LV fractional shortening improved during RVS pacing (0.31 +/- 0.05 vs 0.26 +/- 0.07, P < 0.01). RVS activation increased the resting first pass LV ejection fraction (0.51 +/- 0.14 vs 0.43 +/- 0.10, P < 0.01). No significant difference was observed during RVS and RVA pacing in the exercise time (5.6 +/- 3.2 vs 5.4 +/- 3.1, P = 0.6) or the exercise first pass LV ejection fraction (0.58 +/- 0.15 vs 0.55 +/- 0.16, P = 0.2). The relative changes in QRS duration and LV ejection fraction at both pacing sites showed a significant correlation (P < 0.01). We conclude that RVS pacing produces shorter QRS duration and better chronic LV function than RVA pacing in patients with mild to moderate LV dysfunction and chronic AF after His-bundle ablation.


Assuntos
Fibrilação Atrial/terapia , Fascículo Atrioventricular/cirurgia , Estimulação Cardíaca Artificial , Ablação por Cateter , Ventrículos do Coração/fisiopatologia , Cuidados Pós-Operatórios/métodos , Função Ventricular Direita , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Doença Crônica , Ecocardiografia , Eletrocardiografia , Feminino , Fluoroscopia , Seguimentos , Frequência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Ventriculografia de Primeira Passagem
2.
Pacing Clin Electrophysiol ; 22(12): 1797-801, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10642134

RESUMO

Lead failure places patients with implantable cardioverter defibrillators (ICD) at risk for sudden cardiac death or results in delivery of inappropriate shocks. This study describes a mechanism of lead malfunction occurring at the junction of the terminal ring with the conductor coil of the rate sensing terminal connector in one specific model of a transvenous ICD lead. We detected the problem in a population of 179 patients with a mean age of 61 +/- 10 years and a mean lead implant duration of 16 +/- 11 months. All patients underwent pectoral ICD implantation using a submuscular approach. The implanting physician chose to place the ICD on the left side in 155 patients (87%) and on the right side in 24 patients (13%). Cephalic vein cutdown provided central venous access in 147 patients (82%), and subclavian vein puncture provided access in 32 patients (18%). Follow-up examination detected lead failure in six patients (3.5% over 31 months) due to insulation damage with or without conductor coil fracture at the junction of the terminal ring and conductor coil of the IS-1 rate sense terminal. We detected lead disruption 17 +/- 9 months (range 5-31 months) after implantation. Multiple nonsustained arrhythmia episodes exhibiting nonphysiologic intervals associated with noisy rate sensing electrograms during pocket manipulation led to discovery in three patients. The other three patients presented with inappropriate device discharges confirmed by stored high-energy lead electrograms showing normal rhythm. Pacing lead impedance abnormally dropped in two patients. Impedance remained stable in the other four patients. In conclusion, the generator pocket represents an important site of ICD transvenous lead vulnerability. Lead failure may result from conductor coil and/or insulation disruption at the interface with the rate sensing terminal connector.


Assuntos
Desfibriladores Implantáveis , Adulto , Idoso , Braço/irrigação sanguínea , Arritmias Cardíacas/diagnóstico , Artefatos , Veia Axilar , Cateterismo Venoso Central/instrumentação , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Eletrocardiografia , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Peitorais/cirurgia , Fatores de Risco , Veia Subclávia , Propriedades de Superfície , Venostomia
3.
Am J Cardiol ; 81(12): 1439-45, 1998 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-9645894

RESUMO

This study assesses a technique for quantifying the frequency spectrum of atrial fibrillation (AF) using the surface electrocardiogram. Electrocardiograhic recordings were obtained in 61 patients during AF. After bandpass filtering, the QRST complexes were subtracted using a template-matching algorithm. The resulting fibrillatory baseline signal was subjected to Fourier transformation and displayed as a frequency power spectrum. These frequency spectra were compared to direct measurements from the right atrium and coronary sinus in 35 patients undergoing electrophysiologic study. The clinical use of this technique was explored by correlating fibrillatory frequency with the behavior of the arrhythmia in 26 patients referred for cardioversion. The electrocardiographic frequency spectrum during AF was characterized by a single peak that varied widely between patients (range 228 to 480 beats/min). There was a strong correlation between electrocardiographic peak frequency and that measured in the right atrium and coronary sinus (r = 0.79 to 0.98, p <0.0001). Episodes of AF that terminated in < 5 minutes had a lower frequency than those that persisted > 5 minutes (324 +/- 36 vs 402 +/- 78 beats/min, p = 0.001). Chronic AF (< 3 months in duration) had a lower frequency than chronic AF (present > 3 months) (336 +/- 48 vs 408 +/- 60 beats/ min, p = 0.012). Fibrillation frequency was an accurate predictor of conversion with ibutilide. Success rate was 100% in patients with peak frequency < 360 beats/min versus 29% in patients with frequencies > or = 360 beats/min (p = 0.003). Automatic analysis of the frequency content of the fibrillatory baseline on the surface electrocardiogram accurately reflects the average rate of AF. This measurement correlates with the clinical pattern of the arrhythmia and predicts the response to administration of ibutilide.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/fisiopatologia , Sulfonamidas/uso terapêutico , Adulto , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador
5.
Am J Cardiol ; 80(2): 231-4, 1997 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-9230173

RESUMO

Intracardiac echocardiography was used to evaluate posteroseptal space anatomy in patients with atrioventricular nodal reentrant tachycardia compared with patients with other mechanisms of tachycardia. The posteroseptal space was found to be significantly wider in patients with atrioventricular nodal reentry, suggesting an anatomic basis for dual atrioventricular nodal physiology.


Assuntos
Vasos Coronários/patologia , Coração/anatomia & histologia , Taquicardia por Reentrada no Nó Atrioventricular/patologia , Adolescente , Adulto , Idoso , Vasos Coronários/diagnóstico por imagem , Ecocardiografia/métodos , Feminino , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia Paroxística/diagnóstico por imagem , Taquicardia Paroxística/patologia
6.
Am Heart J ; 130(3 Pt 1): 501-6, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7661067

RESUMO

The objective of this study was to assess the operative risk and efficacy of implantable defibrillators for preventing sudden death in patients with heart failure awaiting transplantation. The average waiting time for elective cardiac transplantation is 6 months to 1 year. Sudden cardiac death is the major source of mortality in outpatients in stable condition awaiting cardiac transplantation. The efficacy of implantable defibrillator therapy in this population is not established. We analyzed the operative risk, time to appropriate shock, and sudden death in 15 patients determined to be at high risk of sudden death who were accepted onto the outpatient cardiac transplant waiting list. Nonfatal postoperative complications occurred in two (13%) subjects with epicardial defibrillating lead systems and in none with transvenous lead systems. Defibrillation energies were 16 +/- 2 J versus 24 +/- 2 J with epicardial and transvenous lead systems, respectively. Sudden death free survival until transplantation was 93%. Most of the patients (60%) had an appropriate shock during a mean follow-up of 11 +/- 12 months. The mean time to an appropriate shock was 3 +/- 3 months. Hospital readmission was required in three (20%) subjects to await transplantation on an urgent basis. However, two of these subjects had received appropriate shocks before readmission. In selected patients at high risk for sudden death while on the outpatient cardiac transplant waiting list, the operative risk is low and adequate defibrillation energies can be obtained to allow implantable defibrillator placement. Most subjects will have an appropriate shock as outpatients before transplantation, and sudden death free survival is excellent.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Transplante de Coração , Cuidados Pré-Operatórios , Análise Atuarial , Adulto , Distribuição de Qui-Quadrado , Doença Crônica , Morte Súbita Cardíaca/epidemiologia , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Los Angeles/epidemiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Listas de Espera