Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
Case Rep Cardiol ; 2020: 6562316, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32158564

RESUMO

A healthy 66-year-old female presented to the emergency department with acute chest pain, T-wave inversion in the anterior leads, and elevated troponin-I. Coronary angiography showed a stenosis in the midportion of the left anterior descending coronary artery (LAD), which did not wrap the left ventricle (LV) apex. LV angiography demonstrated a large LV apical akinetic systolic ballooning with a 45% ejection fraction. Fractional flow reserve (FFR) of LAD lesion was 0.71. Percutaneous intervention was performed. At six months, transthoracic echocardiography was normal. Fifteen months later, the patient presented with chest pain and a small rise in troponin-I. Coronary angiogram was unchanged. Repeat FFR in distal LAD was 0.86 and left ventriculography was normal. Diagnostic criteria for Takotsubo cardiomyopathy (TTC) require the absence of obstructive coronary artery disease. In the present case, TTC was highly suspected on the basis of typical LV apex ballooning. However, significant ischemia in the same territory was demonstrated by positive FFR, which could not be falsely positive in this context. Current TTC diagnostic criteria increase specificity for diagnosing TTC. This case reminds us that it is at the price of reduced sensitivity, since there is no reason to believe that coronary lesions may protect from TTC.

3.
Am J Physiol Lung Cell Mol Physiol ; 318(2): L331-L344, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31721596

RESUMO

Propylene glycol and glycerol are e-cigarette constituents that facilitate liquid vaporization and nicotine transport. As these small hydrophilic molecules quickly cross the lung epithelium, we hypothesized that short-term cessation of vaping in regular users would completely clear aerosol deposit from the lungs and reverse vaping-induced cardiorespiratory toxicity. We aimed to assess the acute effects of vaping and their reversibility on biological/clinical cardiorespiratory parameters [serum/urine pneumoproteins, hemodynamic parameters, lung-function test and diffusing capacities, transcutaneous gas tensions (primary outcome), and skin microcirculatory blood flow]. Regular e-cigarette users were enrolled in this randomized, investigator-blinded, three-period crossover study. The periods consisted of nicotine-vaping (nicotine-session), nicotine-free vaping (nicotine-free-session), and complete cessation of vaping (stop-session), all maintained for 5 days before the session began. Multiparametric metabolomic analyses were used to verify subjects' protocol compliance. Biological/clinical cardiorespiratory parameters were assessed at the beginning of each session (baseline) and after acute vaping exposure. Compared with the nicotine- and nicotine-free-sessions, a specific metabolomic signature characterized the stop-session. Baseline serum club cell protein-16 was higher during the stop-session than the other sessions (P < 0.01), and heart rate was higher in the nicotine-session (P < 0.001). Compared with acute sham-vaping in the stop-session, acute nicotine-vaping (nicotine-session) and acute nicotine-free vaping (nicotine-free-session) slightly decreased skin oxygen tension (P < 0.05). In regular e-cigarette-users, short-term vaping cessation seemed to shift baseline urine metabolome and increased serum club cell protein-16 concentration, suggesting a decrease in lung inflammation. Additionally, acute vaping with and without nicotine decreased slightly transcutaneous oxygen tension, likely as a result of lung gas exchanges disturbances.


Assuntos
Coração/fisiopatologia , Metaboloma , Respiração , Abandono do Hábito de Fumar , Vaping/metabolismo , Vaping/urina , Adulto , Biomarcadores/sangue , Biomarcadores/urina , Pressão Sanguínea , Difusão , Análise Discriminante , Frequência Cardíaca , Hemodinâmica , Hemoglobinas/metabolismo , Humanos , Análise dos Mínimos Quadrados , Lesão Pulmonar/sangue , Lesão Pulmonar/patologia , Lesão Pulmonar/urina , Microcirculação , Nicotina/sangue , Oximetria , Oxigênio/metabolismo , Pressão Parcial , Fluxo Sanguíneo Regional , Testes de Função Respiratória , Pele/irrigação sanguínea , Vaping/sangue , Vaping/fisiopatologia
4.
Am J Physiol Lung Cell Mol Physiol ; 316(5): L705-L719, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30724099

RESUMO

When heated by an electronic cigarette, propylene glycol and glycerol produce a nicotine-carrying-aerosol. This hygroscopic/hyperosmolar aerosol can deposit deep within the lung. Whether these deposits trigger local inflammation and disturb pulmonary gas exchanges is not known. The aim of this study was to assess the acute effects of high-wattage electronic cigarette vaping with or without nicotine on lung inflammation biomarkers, transcutaneous gas tensions, and pulmonary function tests in young and healthy tobacco smokers. Acute effects of vaping without nicotine on arterial blood gas tensions were also assessed in heavy smokers suspected of coronary artery disease. Using a single-blind within-subjects study design, 25 young tobacco smokers underwent three experimental sessions in random order: sham-vaping and vaping with and without nicotine at 60 W. Twenty heavy smokers were also exposed to sham-vaping (n = 10) or vaping without nicotine (n = 10) in an open-label, randomized parallel study. In the young tobacco smokers, compared with sham-vaping: 1) serum club cell protein-16 increased after vaping without nicotine (mean ± SE, -0.5 ± 0.2 vs. +1.1 ± 0.3 µg/l, P = 0.013) and vaping with nicotine (+1.2 ± 0.3 µg/l, P = 0.009); 2) transcutaneous oxygen tension decreased for 60 min after vaping without nicotine (nadir, -0.3 ± 1 vs. -15.3 ± 2.3 mmHg, P < 0.001) and for 80-min after vaping with nicotine (nadir, -19.6 ± 2.8 mmHg, P < 0.001). Compared with sham vaping, vaping without nicotine decreased arterial oxygen tension for 5 min in heavy-smoking patients (+5.4 ± 3.3 vs. -5.4 ± 1.9 mmHg, P = 0.012). Acute vaping of propylene glycol/glycerol aerosol at high wattage with or without nicotine induces airway epithelial injury and sustained decrement in transcutaneous oxygen tension in young tobacco smokers. Intense vaping conditions also transiently impair arterial oxygen tension in heavy smokers.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Pneumonia , Mucosa Respiratória , Vaping , Adulto , Monitorização Transcutânea dos Gases Sanguíneos , Feminino , Humanos , Inflamação/sangue , Inflamação/etiologia , Inflamação/patologia , Inflamação/fisiopatologia , Masculino , Nicotina/farmacocinética , Pneumonia/sangue , Pneumonia/etiologia , Pneumonia/patologia , Pneumonia/fisiopatologia , Testes de Função Respiratória , Mucosa Respiratória/metabolismo , Mucosa Respiratória/patologia , Mucosa Respiratória/fisiopatologia , Uteroglobina/sangue , Vaping/efeitos adversos , Vaping/sangue , Vaping/patologia , Vaping/fisiopatologia
6.
Sci Rep ; 8(1): 10378, 2018 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-29991814

RESUMO

Propylene glycol and glycerol are electronic cigarettes vehicles allowing liquid vaporization and nicotine transport. The respective effects of these different constituents on the cardiovascular system are unknown. We assessed the differential effects of vehicles (propylene glycol and glycerol) and nicotine on microcirculatory function, arterial stiffness, hemodynamic parameters and oxidative stress. Twenty-five tobacco smokers were exposed to vaping with and without nicotine, and sham vaping, in a randomized, single blind, 3-period crossover design study. Neither sham-vaping nor vaping in the absence of nicotine resulted in modifications of cardiovascular parameters or oxidative stress. In contrast, vaping with nicotine: 1) impaired acetylcholine mediated vasodilation (mean ± standard error mean) (area under curve, perfusion unit (PU), 3385 ± 27PU to 2271 ± 27PU, p < 0.0001); 2) increased indices of arterial stiffness, namely augmentation index corrected for heart rhythm (-3.5 ± 1.5% to 1.9 ± 2.3%; p = 0.013) and pulse wave velocity (4.9 ± 0.1 m.s-1 to 5.3 ± 0.1 m.s-1; p < 0.0001); 3) increased systolic and diastolic blood pressures as well as heart rate (all p < 0.0001) and finally; 4) raised plasma myeloperoxidase (median [interquartile range]) (13.6 ng.ml-1 [10-17.7] to 18.9 ng.ml-1 [12.2-54.4], p = 0.005). Our findings demonstrated that high temperature e-cigarette vehicle vaporization does not alter micro- and macro-vascular function, and oxidative stress, and that these effects are solely attributable to nicotine.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Endotélio Vascular/fisiopatologia , Estresse Oxidativo/efeitos dos fármacos , Vaping/efeitos adversos , Rigidez Vascular/efeitos dos fármacos , Estudos Cross-Over , Feminino , Glicerol/farmacologia , Humanos , Masculino , Microcirculação/efeitos dos fármacos , Nicotina/farmacologia , Propilenoglicol/farmacologia , Adulto Jovem
7.
J Invasive Cardiol ; 30(6): 202-206, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29656279

RESUMO

OBJECTIVES: To assess feasibility and short-term clinical outcomes associated with resorbable magnesium scaffold (RMS) implantation in the setting of primary percutaneous coronary intervention for ST-segment elevation myocardial infarction (STEMI). BACKGROUND: RMS implantation has demonstrated favorable clinical outcomes in stable coronary artery disease patients. However, to date, data are lacking in the setting of STEMI. METHODS: This is a single-center prospective non-randomized pilot study. Patients admitted for STEMI were enrolled according to prespecified inclusion and exclusion criteria. The primary endpoint was device-oriented composite endpoint (DOCE), including cardiac death, target-vessel myocardial infarction, and target-lesion revascularization (TLR) within 30 days of the index procedure. Secondary endpoints were procedural success, any probable/definite scaffold thrombosis, and DOCE at subsequent follow-up. RESULTS: From December 1, 2016 to October 30, 2017, a total of 18 patients were included. Follow-up data were available for 17 patients (94%). There was no primary endpoint event. Procedural success was 100%. Patients were followed for a median of 153 days (range, 59-326 days). Over that extended follow-up period, 1 case of TLR occurred 102 days after the index procedure. There was no case of definite or probable scaffold thrombosis. CONCLUSIONS: This pilot study is the first to assess feasibility and clinical outcomes associated with RMS implantation in selected STEMI patients. The results seem reassuring, with favorable short-term clinical outcomes and absence of definite/probable scaffold thrombosis, and should prompt further research including randomized controlled trials evaluating RMS implantation in the setting of STEMI.


Assuntos
Stents Farmacológicos/efeitos adversos , Magnésio/administração & dosagem , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Implantes Absorvíveis/efeitos adversos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Magnésio/efeitos adversos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Projetos Piloto , Estudos Prospectivos , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Resultado do Tratamento
8.
EuroIntervention ; 13(13): 1603-1611, 2018 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-28966159

RESUMO

AIMS: This study aimed to assess the safety and efficacy at midterm follow-up of left atrial appendage occlusion (LAAO) using different devices, in real life in Belgium. METHODS AND RESULTS: Between June 2009 and November 2016, 457 consecutive patients (63% male, 75±12 yrs, CHA2DS2-VASc 4±0.6, HAS-BLED 3.5±0.7) undergoing LAAO were included. Technical success was 97.1%. There were 19 periprocedural major adverse events (4.1%) including three deaths (0.6%), nine tamponades (1.9%), four major bleedings (0.8%) and two device embolisations (0.4%). Among patients successfully implanted having a complete follow-up (672 patient-years, median follow-up 370 days), the actual annual stroke rate was 1.2%, lower than the expected stroke risk of 4% (70% reduction). The observed bleeding rate was 2%, while the calculated risk was 3.7% (46% reduction). Kaplan-Meier analysis showed a similar overall survival (93±2% and 87±3% versus 91±3% and 87±4%; p=0.35) and event-free survival (92±2% and 84±3% versus 88±3% and 80±5%; p=0.17) at one and two years, for the ACP/Amulet versus the WATCHMAN groups of patients, respectively. CONCLUSIONS: The data from the Belgian left atrial appendage occlusion registry suggest that the procedure is effective and relatively safe in a real-world setting, using either the WATCHMAN or the ACP/Amulet device.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Bélgica , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
9.
Echocardiography ; 34(11): 1733-1735, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28929519

RESUMO

We herein describe the previously unreported combination of partial anomalous venous connection to the superior vena cava combined with situs inversus totalis. Following peripheral contrast injection, bubbles appeared initially in the left atrium allowing the diagnosis of a supra-atrial connection to be made using transthoracic echocardiography, but this timing was not anymore reproduced during transesophageal echocardiography performed minutes later. Cardiac computed tomography allowed the final diagnosis to be made. This case emphasizes the importance of performing bubble studies both during transesophageal and transthoracic echocardiography.


Assuntos
Ecocardiografia/métodos , Veias Pulmonares/diagnóstico por imagem , Situs Inversus/diagnóstico por imagem , Veia Cava Superior/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Situs Inversus/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Veia Cava Superior/fisiopatologia
11.
Acta Cardiol ; 69(5): 523-31, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25638840

RESUMO

OBJECTIVE: Biodegradable polymer drug-eluting stents may improve biocompatibility and reduce the risk of very late stent thrombosis (ST) but outcomes are nevertheless unknown in diabetic patients. The purpose of this study was to assess the long-term efficacy and safety of the biodegradable polymer biolimus A9-eluting stent (BP-BES) in comparison with the current reference durable polymer everolimus-eluting stent (DP-EES) in diabetic patients. METHODS AND RESULTS: 119 BP-BES and 178 DP-EES were implanted respectively in 105 and 146 diabetic patients presenting similar clinical and peri-procedural characteristics. The median follow-up time was 20.8 months. No statistically significant difference was observed between the BP-BES and DP-EES groups in terms of occurrence of the composite primary end point of cardiac death, spontaneous myocardial infarction and clinically indicated target lesion revascularization (8 patients [8%] in the BP-BES group versus 24 patients [17%] in the DP-EES group; HR 1.36, 95% CI 0.59-3.15, P = 0.47) and of the rate of ST (5 patients [5%] in the BP-BES group versus 11 patients [8%] in the DP-EES group; HR 0.73, 95% CI 0.22-2.37, P = 0.60). CONCLUSIONS: In spite of a trend in favour of the BP-BES, long-term efficacy and safety were similar for both the BP-BES and the DP-EES in this specific population of diabetic patients. Considering the low incidence of the studied clinical events, other studies with larger population sizes are needed to confirm this observation.


Assuntos
Doenças Cardiovasculares/tratamento farmacológico , Complicações do Diabetes/tratamento farmacológico , Stents Farmacológicos , Imunossupressores/administração & dosagem , Sirolimo/análogos & derivados , Idoso , Materiais Revestidos Biocompatíveis , Everolimo , Feminino , Humanos , Masculino , Segurança do Paciente , Polímeros , Estudos Prospectivos , Sistema de Registros , Sirolimo/administração & dosagem
12.
Europace ; 14(4): 496-501, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22071380

RESUMO

AIMS: This prospective non-randomized single-centre registry compared clinical outcome, pacing parameters, and long-term survival in patients receiving VDD or DDD pacemaker (PMs) for symptomatic atrioventricular (AV) block. METHODS AND RESULTS: Single-lead VDD (n= 166) and DDD (n= 254) PMs were implanted in 420 successive patients with isolated AV block between January 2001 and December 2009. At the end of the follow-up period [median 25 (1-141) months], there was no difference in the incidence of atrial fibrillation [11.2% in the VDD group; 11.4% in the DDD group (P= 0.95)], myocardial infarction [31.1% in the VDD group; 25.2% in the DDD group (P= 0.20)], or dilated cardiomyopathy [9.9% in the VDD group; 8.9% in the DDD group (P= 0.74)]. At last follow-up, 65.9% of the VDD PMs and 89.3% of the DDD PMs were still programmed in their original mode with good atrial sensing. Due to permanent atrial fibrillation, 7.9% patients out of the VDD group had been switched to VVIR mode and 8.7% patients out of the DDD group to VVIR or DDIR mode. The P-wave amplitude was poor (sensed P-wave <0.5 mV) in 19.1% of the VDD PM and 1.6% of the DDD PM (P< 0.001) and 7.1% of the VDD patients and 0.4% of the DDD patients had been switched to VVIR pacing mode due to P-wave undersensing and AV dissociation (P= 0.003). Symptomatic atrial undersensing requiring upgrading was similar in both groups. The overall survival, adjusted for age, was not significantly different in the VDD and the DDD group (log rank: 0.26). Moreover, Cox survival analysis excluded the pacing mode as a significant predictor of mortality [hazard ratio (HR) = 0.79, confidence interval (CI) (0.46-1.35), P= 0.39]. CONCLUSION: Comparing VDD and DDD pacing, a significantly larger number of VDD-paced patients developed poor atrial signal detection without clinical impact. However, atrial under sensing did not influence the incidence of atrial fibrillation, myocardial infarction, dilated cardiomyopathy, or mortality.


Assuntos
Bloqueio Atrioventricular/mortalidade , Bloqueio Atrioventricular/prevenção & controle , Estimulação Cardíaca Artificial/mortalidade , Estimulação Cardíaca Artificial/métodos , Idoso , Bélgica/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Prevalência , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...