Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Dig Surg ; 24(5): 395-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17785986

RESUMO

Anti-Yo-associated paraneoplastic cerebellar degeneration is a cancer-related syndrome affecting the nervous system. This syndrome occurs almost exclusively in middle-aged women with gynecological cancers and it is rarely found in patients with other types of cancer or in males. In this report we describe a male patient adenocarcinoma of the gastroesophageal junction and PCD with anti-Yo antibodies. To our knowledge, this is only the third report of PCD with positive anti-Yo antibodies in an esophageal tumor and the first report in a tumor of the gastroesophageal junction.


Assuntos
Adenocarcinoma/imunologia , Neoplasias Esofágicas/imunologia , Junção Esofagogástrica , Proteínas do Tecido Nervoso/imunologia , Degeneração Paraneoplásica Cerebelar/imunologia , Adenocarcinoma/patologia , Neoplasias Esofágicas/patologia , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Degeneração Paraneoplásica Cerebelar/patologia
3.
Biomaterials ; 25(20): 5037-44, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15109866

RESUMO

Calcium sulfate as a bone graft substitute is rapidly resorbed in vivo releasing calcium ions but fails to provide long-term three-dimensional framework to support osteoconduction. The setting properties of calcium sulfate however allow it to be applied in a slurry form making it easier to handle and apply in different situations. This study examines the in vivo response of calcium sulfate alone and as a carrier for a coralline hydroxyapatite in an established bilateral corticocancellous defect model in rabbits. Defects were filled flush to the anterior cortex with a resorbable porous ceramic alone and in combination with calcium sulfate slurry, calcium sulfate slurry alone or calcium sulfate pellets and examined at time points up to 52 weeks. Specimens where assessed using Faxitron X-ray, light and electron microscopy. Calcium sulfate in either slurry or pellet form does indeed support new bone formation alone however, complete filling of the bone defect is not observed. Calcium sulfate in slurry form does however improve the surgical handling of particulate bone graft substitutes such as Pro Osteon 200 R, which remained as an osteoconductive scaffold for up to 52 weeks and may have played an important role in the ultimate closure of the cortical windows.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis , Substitutos Ósseos/química , Cerâmica/química , Hidroxiapatitas/química , Tíbia/patologia , Animais , Osso e Ossos/química , Cálcio/química , Sulfato de Cálcio/química , Durapatita , Microanálise por Sonda Eletrônica , Íons , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Transplante de Órgãos , Próteses e Implantes , Coelhos , Fatores de Tempo
4.
J Orthop Res ; 21(4): 655-61, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12798065

RESUMO

The success of converted corals as a bone graft substitute relies on a complex sequence of events of vascular ingrowth, differentiation of osteoprogenitor cells, bone remodeling and graft resorption occurring together with host bone ingrowth into and onto the porous coralline microstructure or voids left behind during resorption. This study examined the resorption rates and bone infiltration into a family of resorbable porous ceramic placed bilaterally in critical sized defects in the tibial metaphyseal-diaphyseal of rabbits. The ceramics are made resorbable by partially converting the calcium carbonate of corals to form a hydroxyapatite (HA) layer on all surfaces. Attempts have been made to control the resorption rate of the implant by varying the HA thickness. New bone was observed at the periosteal and endosteal cortices, which flowed into the centre of the defect supporting the osteoconductive nature of partially converted corals. The combination of an HA layer and calcium carbonate core provides a composite bone graft substitute for new tissue integration. The HA-calcium carbonate composite demonstrated an initial resorption of the inner calcium carbonate phase but the overall implant resorption and bone ingrowth behaviour did not differ with HA thickness.


Assuntos
Substitutos Ósseos/farmacologia , Cerâmica , Durapatita/farmacologia , Osseointegração/efeitos dos fármacos , Tíbia/cirurgia , Animais , Antozoários/ultraestrutura , Reabsorção Óssea/tratamento farmacológico , Carbonato de Cálcio/farmacocinética , Fosfatos de Cálcio/metabolismo , Diáfises/fisiologia , Diáfises/cirurgia , Microscopia Eletrônica de Varredura , Modelos Animais , Coelhos , Tíbia/fisiologia , Anormalidade Torcional , Suporte de Carga
5.
Calcif Tissue Int ; 71(2): 172-8, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12200649

RESUMO

The search for an ideal bone substitute is ongoing. Multiple osteoconductive bone substitutes are available today. Plaster of Paris (POP) (calcium sulfate) has been used for more than 100 years for treatment of skeletal defects. This implant is compared to a new material, hydroxyapatite/calcium carbonate (HA/CC), in a rabbit tibia model. HA/CC is made from partial conversion of coralline calcium carbonate to hydroxyapatite and has an outer hydroxyapatite layer and an inner calcium carbonate core, a combination that leads to faster resorption than that of pure hydroxyapatite. This study compares the histomorphometric and radiographic properties of POP and HA/CC in a rabbit tibial defect. Both implants preferentially restore bone to the cortex relative to the canal. Plaster of Paris was fully resorbed by 6 weeks both radiographically and histometrically and HA/CC was substantially resorbed by 42 weeks. No significant difference was noted in volume fraction of bone between the two implants at 42 weeks postimplantation. Hydroxyapatite/calcium carbonate is a biocompatible bone graft substitute with a rate of resorption significantly slower than plaster of Paris.


Assuntos
Substitutos Ósseos , Carbonato de Cálcio , Sulfato de Cálcio , Durapatita , Osseointegração , Tíbia/crescimento & desenvolvimento , Animais , Feminino , Teste de Materiais , Microscopia Eletrônica de Varredura , Coelhos , Tíbia/lesões , Tíbia/ultraestrutura
6.
J Biomed Mater Res ; 47(1): 71-8, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10400883

RESUMO

To improve the understanding of the functional requirements of trabecular bone substitutes, the structure-function relationships of coralline hydroxyapatite were determined and compared to those of trabecular bone from a variety of anatomic sites. Mechanical properties and permeability of cylindrical coralline hydroxyapatite specimens were measured and related to various morphological parameters that were obtained from analysis of high-resolution (20 microm) computer reconstructions of each specimen. Results indicated the average (+/-SD) Young's modulus (2900 +/- 1290 MPa, n = 20) and permeability (0.50 +/- 0.19 x 10(-9) m2, n = 21) of the coralline hydroxyapatite were within the range of values exhibited by high density trabecular bone; ultimate stress (5.87 +/- 1.92 MPa, n = 13), while in the range of mid-density trabecular bone, was low considering its high volume fraction (31.3 +/- 1.9%, n = 49); and ultimate strain (0.22 +/- 0.03%, n = 13) was much lower than that of trabecular bone from any anatomic site. The only correlation found between mechanical and morphological parameters was between Young's modulus and "fabric" (a scalar measure of architecture that combined the degree of microstructural anisotropy with orientation). These results provide insight into the in vivo performance of this implant, as well as the biomechanical requirements for successful trabecular bone substitutes in general.


Assuntos
Substitutos Ósseos/química , Cerâmica/química , Hidroxiapatitas/química , Animais , Fenômenos Biomecânicos , Bovinos , Humanos , Técnicas In Vitro , Teste de Materiais , Relação Estrutura-Atividade
7.
Am J Physiol ; 269(2 Pt 2): H433-42, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7653607

RESUMO

A new method has been developed for measuring the stress-strain relationship in excised canine pulmonary arteries. Segments of dog main right pulmonary arteries were isolated by making two transverse cuts at each end of a segment near the bifurcations, yielding short cylinders, which were then cut radially, relieving the residual stress, causing the cylindrical shells to spring open to approximately flat rectangular slabs with dimensions approximately 1.0 x 3.0 x 0.1 cm. The specimens were then tested using a biaxial tensile testing machine. The resulting data show an approximately linear relationship between Kirchhoff stress and Lagrangian strain with very little hysteresis. The following pseudostrain energy function serves as a practical approximation for pulmonary arteries subjected to physiological levels of stress and strain: rho 0W(2) = 1/2(a1E2xx + a2E2yy + 2 a4ExxEyy), where rho 0 is the density of the wall (mass per unit volume), W is the energy per unit mass [superscript "(2)" indicates this is a 2-dimensional strain energy function], E is strain, a1, a2, and a4 are material constants with units of stress, and the subscripts x and y refer to the circumferential and axial axes, respectively, of the artery. To assess the physiological level of strain in the main right pulmonary artery, vessels were perfused in situ at physiological pressure (26 cmH2O) with silicone elastomer. The arteries were then excised and marked with small ink spots. Photographs of the spots on four tangent planes of the excised artery indicate a maximum circumferential strain of 21.5% and a maximum axial strain of 36.5% relative to the zero-stress state. These values are within the range of strain used in the biaxial tests. The relationship between Kirchhoff stress and Green's strain is approximately linear within the physiological range. The stress levels required to cause tissue failure are at least 10 times greater than the estimated normal physiological level.


Assuntos
Artéria Pulmonar/fisiologia , Animais , Fenômenos Biomecânicos , Cardiologia/instrumentação , Cardiologia/métodos , Cães , Técnicas In Vitro , Modelos Cardiovasculares , Estresse Mecânico
8.
J Appl Physiol (1985) ; 76(2): 875-81, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8175602

RESUMO

To understand the hemodynamic alterations associated with chronic thromboembolic pulmonary hypertension, the large pulmonary arteries of mongrel dogs were chronically obstructed with lysis-resistant thrombi. Pulmonary hemodynamics were experimentally measured and described by multipoint pulmonary arterial pressure (PAP) vs. flow plots. In nine anesthetized chronically embolized dogs, but not in six control dogs, the PAP-flow line shifted significantly upward in a parallel fashion by 4.2 +/- 0.7 mmHg. The postembolic pulmonary circulation was further characterized by predictions from a morphometric-based elastic tube and sheet flow model of the canine pulmonary circulation. After model validation with the preembolic PAP-flow data, the derived postembolic PAP matched the in vivo results to within 1 mmHg. A detailed analysis of the model-derived PAP drop revealed that the PAP-flow line shift can be accounted for by a novel fixed resistor in the largest obstructed pulmonary artery.


Assuntos
Pressão Sanguínea , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Tromboembolia/fisiopatologia , Animais , Doença Crônica , Cães , Previsões , Hipertensão Pulmonar/etiologia , Modelos Cardiovasculares , Tromboembolia/complicações
9.
Am J Physiol ; 266(1 Pt 2): H1-10, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8304490

RESUMO

Although the mechanical properties of blood vessels have been studied extensively, the shear modulus of the blood vessel wall is still unknown. New data on the shear modulus of elasticity of rat arteries and its variation with axial stretch and blood pressure are presented. The data were obtained from a new instrument designed and constructed by us to perform simultaneous torsion, inflation, and longitudinal stretching tests. It was found under physiological conditions (pressure = 120 mmHg or 16 kPa; longitudinal stretch = 1.2 relative to zero-stress state), the shear modulus of normal rat thoracic aorta is G = 137 +/- 18 kPa. The difference of shear modulus at body temperature (37 degrees C) and room temperature (25 degrees C) is within 10%. The shear modulus varies significantly with changing longitudinal and circumferential strains in proportion to the strain energy due to these strains. A constitutive equation based on a pseudo strain energy function is proposed. The vessel wall is not transversely isotropic in the incremental sense. When the rat was subjected to high blood pressure due to constriction of its aorta, the shear modulus does not vary significantly with the length of time the animal was subjected to hypertension.


Assuntos
Artérias/fisiologia , Animais , Aorta Torácica/fisiologia , Artérias/fisiopatologia , Elasticidade , Hipertensão/fisiopatologia , Modelos Cardiovasculares , Ratos , Ratos Sprague-Dawley , Estresse Mecânico , Temperatura , Vasodilatação
10.
Ann Biomed Eng ; 21(1): 51-5, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8434820

RESUMO

Adherence of a biological graft to the wound surface is the most important factor influencing the ultimate success of graft viability. A machine has been developed to test the adherence of biological graft materials to a substrate such as a wound surface. The peeling mode, which yields reproducible quantitative measurements of adherence, is a standard method for testing adhesives. The device is designed to continuously measure the force required to peel the graft from the substrate at a constant rate. This force is a function of the energy of adhesion per unit area of adhered surface. This device has been used to measure the peeling force of (2 x 2 cm) skin grafts which are applied to full-thickness wounds on mice. Results of tests on adherence of autografts on mice show that the peeling force increases significantly with time over the first 9 days of healing. Thus, this device is useful in quantitative comparison of various skin grafting techniques and artificial grafts.


Assuntos
Teste de Materiais/instrumentação , Transplante de Pele/normas , Ferimentos e Lesões/terapia , Adesividade , Animais , Fenômenos Biomecânicos , Estudos de Avaliação como Assunto , Feminino , Humanos , Camundongos , Fatores de Tempo , Cicatrização , Ferimentos e Lesões/fisiopatologia
11.
J Appl Physiol (1985) ; 73(3): 1171-80, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1400033

RESUMO

The influence of temperature on the mechanical properties of excised saline-filled lung parenchyma of the dog was studied at low lung volume. The motivation of this study was to determine whether lung tissue material without the influence of surface tension undergoes a phase transition in the 20-40 degrees C range, as does synthetic elastin studied by Urry in 1984-1986. Dynamic biaxial and uniaxial tensile tests were done, and strain vs. Lagrangian stress curves were recorded during slow cooling and heating between 40 and 10 degrees C. To emphasize the effects of elastin, strains (defined as stretch ratio minus one) were kept below 30%. A slight decrease in compliance occurred with cooling over the entire temperature range. This effect may be attributed to collagen. It was accompanied by a gradual increase in length as the tissue cooled, an effect that may be attributed to elastin. This process was partially reversible with reheating. However, this effect is in contrast with the sudden drastic change in mechanical properties of synthetic elastin described by Urry. Hysteresis, creep, and stress relaxation were small at these low strains. Possible causes of these effects are discussed.


Assuntos
Pulmão/fisiologia , Mecânica Respiratória/fisiologia , Animais , Colágeno/fisiologia , Cães , Elasticidade , Elastina/fisiologia , Técnicas In Vitro , Complacência Pulmonar/fisiologia , Medidas de Volume Pulmonar , Modelos Biológicos , Atelectasia Pulmonar/fisiopatologia , Temperatura , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...