Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 6(23): 9328-9332, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25558291

RESUMO

In the present paper, we showed the advantages of trapped ion mobility spectrometry coupled too mass spectrometry (TIMS-MS) combined with theoretical calculations for fast identification (millisecond timescale) of polycyclic aromatic hydrocarbons (PAH) compounds from complex mixtures. Accurate PAH collision cross sections (CCS, in nitrogen as a bath gas) are reported for the most commonly encountered PAH compounds and the ability to separate PAH geometric isomers is shown for three isobaric pairs with mobility resolution exceeding 150 (3-5 times higher than conventional IMS devices). Theoretical candidate structures (optimized at the DFT/B3LYP level) are proposed for the most commonly encountered PAH compounds showing good agreement with the experimental CCS values (<5%). The potential of TIMS-MS for the separation and identification of PAH compounds from complex mixtures without the need of lengthy pre-separation steps is illustrated for the case of a complex soil mixture.

2.
Surf Interface Anal ; 45(1): 134-137, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24163486

RESUMO

The current limitation for SIMS analyses is insufficient secondary ion yields, due in part to the inefficiency of traditional primary ions. Massive gold clusters are shown to be a route to significant gains in secondary ion yields relative to other commonly used projectiles. At an impact energy of 520 keV, [Formula: see text] is capable of generating an average of greater than ten secondary ions per projectile, with some impact events generating >100 secondary ions. The capability of this projectile for signal enhancement is further displayed through the observation of up to seven deprotonated molecular ions from a single impact on a neat target of the model pentapeptide leu-enkephalin. Positive and negative spectra of leu-enkephalin reveal two distinct emission regimes responsible for the emission of either intact molecular ions with low internal energies or small fragment species. The internal energy distribution for this projectile is measured using a series of benzylpyridinium salts and compared with the small polyatomic projectile [Formula: see text] at 110 keV as well as distributions previously reported for electrospray ionization and fast atom bombardment. These results show that [Formula: see text] offers high secondary ion yields not only for small fragment ions, e.g. CN-, typically observed in SIMS analyses, but also for characteristic molecular ions. For the leu-enkephalin example, the yields for each of these species are greater than unity.

3.
Surf Interface Anal ; 45(1): 329-332, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24163487

RESUMO

Secondary ion mass spectrometry (SIMS) applied in the event-by-event bombardment/detection mode is uniquely suited for the characterization of individual nano-objects. In this approach, nano-objects are examined one-by-one, allowing for the detection of variations in composition. The validity of the analysis depends upon the ability to physically isolate the nano-objects on a chemically inert support. This requirement can be realized by deposition of the nano-objects on a Nano-Assisted Laser Desorption/Ionization (NALDI™) plate. The featured nanostructured surface provides a support where nano-objects can be isolated if the deposition is performed at a proper concentration. We demonstrate the characterization of individual nano-objects on a NALDI™ plate for two different types of nanometric bacteriophages: Qß and M13. Scanning electron microscope (SEM) images verified that the integrity of the phages is preserved on the NALDI™ substrate. Mass spectrometric data show secondary ions from the phages are identified and resolved from those from the underlying substrate.

4.
Surf Interface Anal ; 45(1)2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24163488

RESUMO

The use of large cluster primary ions (e.g. C60, Au400) in secondary ion mass spectrometry has become prevalent in recent years due to their enhanced emission of secondary ions, in particular, molecular ions (MW ≤ 1500 Da). The co-emission of electrons with SIs was investigated per projectile impact. It has been found that SI and electrons yields increased with increasing projectile energy and size. The use of the emitted electrons from impacts of C60 for localization has been demonstrated for cholesterol deposited on a copper grid. The instrumentation, methodologies, and results from these experiments are presented.

5.
Surf Interface Anal ; 45(1)2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24163489

RESUMO

This paper describes the application of nanoparticle bombardment with time-of-flight secondary ion mass spectrometry (NP-ToF-SIMS) for the analysis of native biological surfaces for the case of sagittal sections of mammalian brain tissue. The use of high energy, single nanoparticle impacts (e.g. 520 keV Au400) permits desorption of intact lipid molecular ions, with enhanced molecular ion yield and reduced fragmentation. When coupled with complementary molecular ion fragmentation and exact mass measurement analysis, high energy nanoparticle probes (e.g. 520 keV Au400 NP) provide a powerful tool for the analysis of the lipid components from native brain sections without the need for surface preparation and with ultimate spatial resolution limited to the desorption volume per impact (~103 nm3).

6.
Nucl Instrum Methods Phys Res B ; 273: 270-273, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22393269

RESUMO

This paper describes the advantages of using single impacts of large cluster projectiles (e.g. C(60) and Au(400)) for surface mapping and characterization. The analysis of co-emitted time-resolved photon spectra, electron distributions and characteristic secondary ions shows that they can be used as surface fingerprints for target composition, morphology and structure. Photon, electron and secondary ion emission increases with the projectile cluster size and energy. The observed, high abundant secondary ion emission makes cluster projectiles good candidates for surface mapping of atomic and fragment ions (e.g., yield >1 per nominal mass) and molecular ions (e.g., few tens of percent in the 500 < m/z < 1500 range).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...