Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Wiad Lek ; 76(8): 1790-1796, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37740972

RESUMO

OBJECTIVE: The aim: To study the osseointegrative properties of titanium and tantalum implants with different surface structures in animal experiments. PATIENTS AND METHODS: Materials and methods: The histological and morphometric study was carried out on 60 male white rats after titanium implants with different surface structures made by 3D printed technology were inserted in the distal femur bone: presented by the multilayered layers of interlacing pores of 300 microns (series 1); rough (> 2 microns) (series 2); and tantalum implants with 300 microns pores and 80% porosity (series 3) as control material. RESULTS: Results: On the 30 days we found statistically significant differences in the bone-implant contact rate between the 2nd experiment series (44.77 ± 1.86)% and 1st (59.91 ± 2.86)% (p=0.000047) and 3rd (53.89 ± 2.11)% (р=0.000065), on the 90 days between the 2nd experiment series (51.26 ± 2.7)% and 1st (66.84 ± 2.63)% (p=0.000187) and 3rd (70.35 ± 4.32)% (p=0.000349). There was a difference between the indices of the bone-implant volume at day 90 between the 1st (48.43 ± 2.2)% and 2nd (36.88 ± 2.56)% series (p=0.000919), between the 2nd and 3rd series (51.2 ± 3.06)% (p=0.000107). There were no significant differences between the studied indices in the 1st and 3rd series of the experiment. CONCLUSION: Conclusions: Titanium implants with multilayered interlaced pore layers of 300 microns and tantalum with 300 microns pore size and 80% porosity may be promising. Rough-surface titanium also has osseointegrative qualities, but they are lower compared to other materials.

2.
Wiad Lek ; 74(4): 992-997, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34156018

RESUMO

OBJECTIVE: The aim: Study of the dynamics of morphological rearrangement of bone under conditions of immediate occlusive functional load and the effect of splinting of implants with temporary orthopedic structures with the analysis of the coefficient of stability of implants during immediate implantation in the experiment. PATIENTS AND METHODS: Materials and methods: A series of experiments was performed on 6 male Duroc pigs at the age of 6 months and weighing 40-60 kg. In the course of recent advances, the following methods have been used: the clinical protocol of immediate - implantation of time-consuming clothes, the definition of COEFICIENT, morphometry and light microscopy of the slides, statistical analysis. RESULTS: Results: By morphometric examination after 3 months the BIC in the series with splinting was 1.68 times higher compared to 1 month. studies, in a series of experiments without splinting - 1.9 times, after 3 months. the difference between implantation experiments with splinting components and without splinting is 1.6 times. During the functional study of the resonant - frequency analyzer, there is an increase in the ISQ in the second and third months after surgery, but this figure is higher in the study using the splint component. CONCLUSION: Conclusions: Stagnation of the shingle component in the case of intrinsic intraoperative functional juvenile implantation accelerates the dynamics of osteointegration, so that high indicators of the efficiency of the implant stability can be achieved.


Assuntos
Implantes Dentários , Animais , Masculino , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...