Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Rev Bras Ortop (Sao Paulo) ; 59(4): e532-e541, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39239585

RESUMO

Objective Although autologous bone grafting is the most widely used treatment for bone defects, the most effective preparation remains unclear. This animal study aimed to compare different autologous bone grafting preparation for the treatment of rat́s calvaria critical bone defect. Methods 122 rats were randomly allocated into three groups: Simulado, Macerated and Chopped. The specimens underwent craniotomies at the top center of their calvarias with a 7mm diameter circumferential cutter drill. The critical bone defect produced was treated or not according to the group the specimen wasallocated. The rats were euthanized at 3, 6 or 12 weeks post-op and its calvarias were analyzed by histomorphometry, bone densitometry, nanocomputed tomography (nCT), and biomechanical tests. Results The histomorphometry analysis showed the highest percentage of fulfillment of the critical bone defect in the chopped and macerated group when compared to simulado. The densitometry assessment evidenced higher bone mass at all endpoints analysis (p < 0.05) in the chopped group. The nCT data exhibited an expressive increase of bone in the chopped group when compared with the simulado and macerated groups. The biomechanical tests exhibited highest values of deformation, maximum force, and relative stiffness in the chopped group at any time of euthanasia (p < 0.05). Conclusions Our experimental work showed that chopped bone grafting preparation exhibited significant better outcomes than macerated in the treatment of a critical bone defect in rat́s calvaria.

2.
Eur Spine J ; 33(2): 646-654, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37801129

RESUMO

PURPOSE: Abnormal leptin bioavailability has play key roles in the etiology of adolescent idiopathic scoliosis (AIS). Both leptin and its receptor levels may be modulated by the presence of genetic polymorphisms. This study aimed to evaluate the role of polymorphisms in the leptin (LEP) and its main receptor (LEPR) genes in the AIS susceptibility in girls. METHODS: A retrospective case-control study was conducted with 189 AIS and 240 controls. LEP rs2167270 and LEPR rs2767485 polymorphisms were genotyped using a TaqMan validated assay. Associations were evaluated by odds ratios (OR) and 95% confidence intervals (CI). RESULTS: The AIS group showed a predominance of girls under 18 years old (n = 140, 74.1%), 148 (78.3%) had low or normal BMI, 111 (58.7%) had Cobb ≥ 45º and 130 (68.7%) were skeletally mature. Minor allele frequencies of rs2167270 and rs2767485 were 35.7% and 18.3%, for AIS and 35.6% and 25.4% for controls, respectively. LEPR rs2767485 T and TC + TT were associated with higher risk of AIS (OR = 1.53; 95% CI = 1.09-2.13 and OR = 1.84; 95% CI = 1.69-2.01, respectively), since CC genotype was only present in the control group. In addition, the LEP rs2167270 GA + AA was more frequent in low weight group (BMI ≤ 24.9) of girls with AIS. There was no significant association between LEP rs2167270 and AIS susceptibility, and LEPR rs2767485 and BMI. CONCLUSION: The LEPR rs2767485 was associated with the genetic susceptibility of AIS and LEP rs2167270 with low BMI. These data can contribute to the identification of genetic biomarkers to improve the diagnosis and treatment.


Assuntos
Leptina , Escoliose , Feminino , Humanos , Adolescente , Masculino , Leptina/genética , Receptores para Leptina/genética , Estudos de Casos e Controles , Estudos Retrospectivos , Escoliose/genética , Polimorfismo de Nucleotídeo Único/genética
3.
Rev. Bras. Ortop. (Online) ; 59(4): 532-541, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1575593

RESUMO

Abstract Objective Although autologous bone grafting is the most widely used treatment for bone defects, the most effective preparation remains unclear. This animal study aimed to compare different autologous bone grafting preparation for the treatment of rats calvaria critical bone defect. Methods 122 rats were randomly allocated into three groups: Simulado, Macerated and Chopped. The specimens underwent craniotomies at the top center of their calvarias with a 7mm diameter circumferential cutter drill. The critical bone defect produced was treated or not according to the group the specimen wasallocated. The rats were euthanized at 3, 6 or 12 weeks post-op and its calvarias were analyzed by histomorphometry, bone densitometry, nanocomputed tomography (nCT), and biomechanical tests. Results The histomorphometry analysis showed the highest percentage of fulfillment of the critical bone defect in the chopped and macerated group when compared to simulado. The densitometry assessment evidenced higher bone mass at all endpoints analysis (p < 0.05) in the chopped group. The nCT data exhibited an expressive increase of bone in the chopped group when compared with the simulado and macerated groups. The biomechanical tests exhibited highest values of deformation, maximum force, and relative stiffness in the chopped group at any time of euthanasia (p < 0.05). Conclusions Our experimental work showed that chopped bone grafting preparation exhibited significant better outcomes than macerated in the treatment of a critical bone defect in rats calvaria.


Resumo Objetivo Embora enxertos ósseos autólogos sejam o tratamento mais utilizado para defeitos ósseos, a preparação mais eficaz ainda é obscura. Este estudo animal teve como objetivo comparar diferentes preparações de enxerto ósseo autólogo para o tratamento de defeito ósseo crítico no crânio de ratos. Métodos No total, 122 ratos foram alocados aleatoriamente em três grupos: Simulado, enxerto macerado e enxerto picado. Os espécimes foram submetidos a craniotomias no centro superior do crânio com broca de corte circunferencial de 7 mm de diâmetro. O defeito ósseo crítico produzido foi tratado ou não de acordo com o grupo de alocação do animal. Os ratos foram eutanasiados às 3, 6 ou 12 semanas após a cirurgia e seus crânios foram analisados por histomorfometria, densitometria óssea, nanotomografia computadorizada (nTC) e testes biomecânicos. Resultados A análise histomorfométrica mostrou maior percentual de preenchimento do defeito ósseo crítico no grupo picado e macerado em comparação ao simulado. A avaliação densitométrica evidenciou maior massa óssea em todos os desfechos de análise (p < 0,05) no grupo picado. Os dados de nTC revelaram um aumento ósseo expressivo no grupo picado em comparação aos grupos simulado e macerado. Os testes biomecânicos mostraram maiores valores de deformação, resistência máxima e rigidez relativa no grupo picado em qualquer momento da eutanásia (p < 0,05). Conclusões Nosso estudo mostrou que a preparação de enxerto ósseo picado gerou resultados significativamente melhores do que os enxertos macerados no tratamento de defeitos ósseos críticos no crânio de ratos.

4.
J Pers Med ; 13(3)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36983638

RESUMO

BACKGROUND: The authors conducted a 2-year retrospective follow-up to investigate the efficiency of an extraforaminal full-endoscopic approach with foraminoplasty used to treat lateral compressive diseases of the lumbar spine in 247 patients. METHODS: The visual analogue scale (VAS), Oswestry disability index (ODI), and MacNab scale were used to analyze the results collected during the preoperative and postoperative periods. RESULTS: The most common diagnosis was disk herniation with lateral recess stenosis, and the most common surgical level among patients was between L4 and L5 on the left side. Pain decreased over time, as determined during sessions held to evaluate pain in the lumbar, gluteal, led, and foot regions. The ODI demonstrated significant enhancement over the evaluation period and the MacNab scale classified the surgery as good or excellent. The most common complication was dysesthesia. CONCLUSIONS: An extraforaminal full-endoscopic approach with foraminoplasty can be recommended in cases of lateral herniation or stenosis for patients with symptoms of radiculopathy, and for those who have not responded to conventional rehabilitation treatment or chronic pain management. Few complications arose as a result of this approach, and most of them were treated clinically.

5.
Coluna/Columna ; 22(1): e262504, 2023. graf, il
Artigo em Inglês | LILACS | ID: biblio-1421316

RESUMO

ABSTRACT Objectives: Evaluate the treatment outcome and the performance of the uCentum spinal fixation system in treating traumatic, degenerative, and tumoral diseases of the spine. Methods: This is a therapeutic study to investigate treatment outcomes and level of evidence III, including twenty-three adult patients of both sexes undergoing surgical treatment of degenerative (13 patients), traumatic (04 patients), or tumor diseases (06 patients). Patients were prospectively evaluated using clinical parameters: pain (visual analog scale), clinical and functional assessment questionnaires (SF-36, Oswestry and Roland-Morris), and radiological criteria (arthrodesis consolidation, loosening, breakage or deformation of the implants). Results: Twenty patients were followed for a period of 01 month to 12 month (mean 6,5±7,77). Three patients died due to complications unrelated to the primary disease (traumatic brain injury, septicemia, and lung tumor). Improvements were observed in clinical parameters and scores of the evaluation questionnaires used. No implant-related complications (breakage, loosening, deformation) were observed. Conclusion: the uCentum fixation system showed great versatility for performing the surgical treatment, allowing the performance of open, percutaneous procedures, the introduction of acrylic cement inside the implants, and conversion of polyaxial screws into monoaxial screws intraoperatively. Level of Evidence III; Therapeutic Studies - Investigating the Results of Treatment.


Resumo: Objetivos: Avaliar o resultado do tratamento e o desempenho do sistema uCentum de fixação vertebral no tratamento de doenças traumáticas, degenerativas e tumorais da coluna vertebral. Métodos: Trata-se de um estudo terapêutico de investigação dos resultados do tratamento e nível de evidência III, incluindo vinte e três pacientes adultos de ambos os sexos submetidos ao tratamento cirúrgico de doenças degenerativas (13 pacientes), traumáticas (04 pacientes) ou tumorais (06 pacientes). Os pacientes foram prospectivamente avaliados por meio de parâmetros clínicos: dor (escala visual analógica), questionários de avaliação clínica e funcional (SF-36, Oswestry e Roland-Morris), e critérios radiológicos (consolidação da artrodese, soltura, quebra ou deformação dos implantes). Resultados: vinte pacientes foram seguidos por um período de 01 a 12 meses (média 6,5 ± 7,77). Três pacientes foram a óbito devido a complicações não relacionadas com a doença primária (trauma cranioencefálico, septicemia e tumor pulmonar). Foi observada melhora dos parâmetros clínicos e escores dos questionários de avaliação utilizados. Não foram observadas complicações relacionadas com os implantes (quebra, soltura, deformação). Conclusão: o sistema de fixação uCentum apresentou grande versatilidade para a realização do tratamento cirúrgico, permitindo a realização de procedimentos abertos, percutâneos, introdução de cimento acrílico no interior dos implantes e conversão dos parafusos poliaxiais em monoaxiais no intra-operatório. Nível de Evidencia III; Estudos terapêuticos - Investigação dos resultados do tratamento.


Resumen: Objetivos: Evaluar el resultado del tratamiento y el desempeño del sistema de fijación vertebral uCentum en el tratamiento de enfermedades traumáticas, degenerativas y tumorales de la columna vertebral. Métodos: Este es un estudio terapéutico para investigar los resultados del tratamiento y el nivel de evidencia III, que incluye veintitrés pacientes adultos de ambos sexos sometidos a tratamiento quirúrgico de enfermedades degenerativas (13 pacientes), traumáticas (04 pacientes) o tumorales (06 pacientes). Los pacientes fueron evaluados prospectivamente mediante parámetros clínicos: dolor (escala analógica visual), cuestionarios de evaluación clínica y funcional (SF-36, Oswestry y Roland-Morris) y criterios radiológicos (consolidación de artrodesis, aflojamiento, rotura o deformación de los implantes). Resultados: veinte pacientes fueron seguidos durante un período de 1 a 12 meses (media 6,5 + 7,77). Tres pacientes fallecieron por complicaciones no relacionadas con la enfermedad primaria (lesión cerebral traumática, septicemia y tumor pulmonar). Se observaron mejoras en los parámetros clínicos y puntuaciones de los cuestionarios de evaluación utilizados. No se observaron complicaciones relacionadas con el implante (rotura, aflojamiento, deformación). Conclusión: el sistema de fijación uCentum mostró una gran versatilidad para realizar el tratamiento quirúrgico, permitiendo la realización de procedimientos abiertos, percutáneos, introducción de cemento acrílico en el interior de los implantes y conversión de los tornillos poliaxiales en tornillos monoaxiales en el intraoperatorio. Nivel de Evidencia III; Estudios terapéuticos - Investigación de los resultados del tratamiento.


Assuntos
Humanos , Masculino , Feminino , Fixação de Fratura , Procedimentos Ortopédicos
6.
Coluna/Columna ; 22(1): e262409, 2023. tab, graf, il
Artigo em Inglês | LILACS | ID: biblio-1421317

RESUMO

ABSTRACT Objectives: Evaluate the reliability and reproducibility of the kyphosis measurement in thoracolumbar spine traumatic fractures by different assessment methods in different types of fractures. Methods: Fifteen fractures of the thoracolumbar spine, previously classified into types A, B, and C according to Magerl's classification, were evaluated. The value of kyphosis was measured using five different methods: (1) Cobb angle; (2) Gardner's method; (3) back wall method; (4) angle of adjacent endplates; and (5) wedge angle. The measurements were performed by five independent observers and repeated five times with a minimum interval of two weeks between each evaluation. Results: Intraobserver reliability was excellent among the five observers, evidencing good reproducibility of the methods. The five methods used also showed great intraobserver reliability in the global analysis, with methods one and four being more consistent. Conclusion: Although there is no universal agreement on measuring kyphosis in thoracolumbar fractures, our study concluded that method 1 (Cobb angle) and method 4 (adjacent endplate angle) presented the best interobserver reliabilities. Furthermore, the use of digitized radiographs and a simple computer program allowed the performance of highly reliable and reproducible measurements by all methods, given the high intraobserver reliability. Level of Evidence II; Comparative study.


Resumo: Objetivos: Avaliar a confiabilidade e reprodutibilidade da mensuração da cifose nas fraturas traumáticas da coluna toracolombar por diferentes métodos de avaliação nos diferentes tipos de fraturas. Métodos: Foram avaliadas 15 fraturas na coluna toracolombar previamente classificadas em tipo A, B e C de acordo com a classificação de Magerl. Em cada caso, foi medido o valor da cifose através de cinco diferentes métodos: (1) ângulo de Cobb; (2) método de Gardner; (3) método das paredes posteriores; (4) ângulo das placas terminais adjacentes; e (5) ângulo de cunha. As mensurações foram realizadas por cinco avaliadores independentes e repetidas cinco vezes com intervalo mínimo de duas semanas entre cada avaliação. Resultados: A confiabilidade intraobservador mostrou-se excelente entre os cinco avaliadores, evidenciando boa reprodutibilidade dos métodos. Os cinco métodos utilizados também apresentaram grande confiabilidade intraobservador na análise global, sendo mais consistentes o método 1 e o método 4. Conclusão: Apesar de não haver concordância universal em como medir a cifose nas fraturas toracolombares, nosso estudo concluiu que o método 1 (ângulo de Cobb) e o método 4 (ângulo das placas terminais adjacentes) apresentaram as melhores confiabilidades interobservadores. Além disso, o uso de radiografias digitalizadas e um programa computadorizado simples permitiram a realização de medidas altamente confiáveis e reprodutíveis por todos os métodos, visto pela elevada confiabilidade intraobservador. Nível de evidência II; Estudo Comparativo.


Resumen: Objetivos: Evaluar la fiabilidad y reproducibilidad de mensuración de cifosis en fracturas traumáticas de la columna toracolumbar por diferentes métodos de valoración en diferentes tipos de fracturas. Métodos: Se evaluaron quince fracturas de columna toracolumbar, previamente clasificadas en los tipos A, B y C según la clasificación de Magerl. En cada caso, el valor de la cifosis se midió utilizando cinco métodos diferentes: (1) ángulo de Cobb; (2) método de Gardner; (3) método de la pared posterior; (4) ángulo de placas de extremo adyacentes; y (5) ángulo de cuña. Las mediciones fueron realizadas por cinco evaluadores independientes y repetidas cinco veces con un intervalo mínimo de dos semanas entre cada evaluación. Resultados: La confiabilidad intraobservador fue excelente entre los cinco evaluadores, evidenciando una buena reproducibilidad de los métodos. Los cinco métodos utilizados también mostraron una gran fiabilidad intraobservador en el análisis global, siendo el método 1 y el método 4 más consistentes. Conclusión: Aunque no existe un acuerdo universal sobre cómo medir la cifosis en las fracturas toracolumbares, nuestro estudio concluyó que el método 1 (ángulo de Cobb) y el método 4 (ángulo de la placa terminal adyacente) presentaron las mejores confiabilidades entre observadores. Además, el uso de radiografías digitalizadas y un programa informático simple permitieron realizar mediciones altamente fiables y reproducibles por todos los métodos, dada la alta fiabilidad intraobservador. Nivel de evidencia II; Estudio Comparativo.


Assuntos
Humanos , Coluna Vertebral , Intensificação de Imagem Radiográfica , Fraturas da Coluna Vertebral
7.
Coluna/Columna ; 22(2): e273438, 2023. tab, graf, il. color
Artigo em Inglês | LILACS | ID: biblio-1448038

RESUMO

ABSTRACT Objective: The study correlates angular radiographic measurements and measurements from photographs of the trunk of patients with adolescent idiopathic scoliosis. Methods: a cross-sectional study of 10 patients with adolescent idiopathic scoliosis and indication for surgical treatment in follow-up in the spine sector of HCRFMRP-USP. They were evaluated through measurements taken from clinical photographs of the patient's torso and angles on panoramic radiographs of the spine. Results: only the correlation between the axilla angle (AHA) and the proximal thoracic curve and main thoracic curve was observed in the sample studied. No correlation was observed between the other compared variables. The study was carried out in a sample with a small number of patients, whose objective was to carry out a pilot study to explore this topic. Conclusion: the analysis of deformities should consider the aesthetic aspect and radiographic evaluation; however, in this study, no statistical correlation was observed between these parameters. Level of Evidence IV; Case Series Study.


RESUMO: Objetivo: O estudo correlaciona as mensurações radiográficas angulares e as mensurações oriundas das fotografias do tronco de pacientes com escoliose idiopática do adolescente. Métodos: estudo transversal de 10 pacientes com escoliose idiopática do adolescente e com indicação de tratamento cirúrgico, em seguimento no setor de coluna vertebral do HCRFMRP-USP. Foram avaliados por meio de mensurações das fotografias clínicas do tronco dos pacientes e mensurações dos ângulos nas radiografias panorâmicas da coluna. Resultados: na amostra estudada foi observada somente a correlação entre o ângulo axila (AHA) e a curva torácica proximal e curva torácica principal. Não foi observado correlação entre as demais variáveis comparadas. O estudo foi realizado em amostra com pequeno número de pacientes, cujo objetivo era a realização de estudo piloto para explorar esse tópico. Conclusão: a análise das deformidades deve considerar o aspecto estético e avaliação radiográfica, porem neste estudo não foi observado correlação estatística entre estes parâmetros. Nível de Evidência IV; Estudo de Série de Casos.


RESUMEN: Objetivo: El estudio correlaciona medidas radiográficas angulares y medidas de fotografías del tronco de pacientes con escoliosis idiopática del adolescente. Métodos: estudio transversal de 10 pacientes con escoliosis idiopática del adolescente y con indicación de tratamiento quirúrgico, en seguimiento en el sector de columna del HCRFMRP-USP. Se evaluaron mediante medidas tomadas de fotografías clínicas del torso de los pacientes y medidas de ángulos en radiografías panorámicas de la columna vertebral. Resultados: en la muestra estudiada solo se observó la correlación entre el ángulo axilar (AHA) y la curva torácica proximal y torácica principal. No se observó correlación entre las otras variables comparadas. El estudio se realizó en una muestra con un número reducido de pacientes, cuyo objetivo fue realizar un estudio piloto para explorar este tema. Conclusión: el análisis de las deformidades debe considerar el aspecto estético y la evaluación radiográfica, sin embargo, en este estudio no se observó correlación estadística entre estos parámetros. Nivel de Evidencia IV; Estudio de Serie de Casos.


Assuntos
Humanos , Adolescente , Radiografia , Fotografia , Ortopedia , Diagnóstico por Imagem
8.
Acta Ortop Bras ; 30(4): e249351, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36092173

RESUMO

Introduction: Reduction of spinopelvic mobility is associated with an increased dislocation of total hip arthroplasty (THA). Objective: To assess 1) spinopelvic mobility in patients with primary hip osteoarthritis and THA indication and 2) the influence of hip flexion contracture on spinopelvic mobility. Methods: Thirty adult patients with primary hip osteoarthritis and THA indication were evaluated using radiographic parameters (pelvic incidence, pelvic tilt, sacral slope, lumbar flexibility, and spinopelvic mobility). Results: Spinopelvic mobility ranged from 6.90 a 54.50° (mean 32.79 ± 11.42) and the group of patients with hip flexion contracture had higher mobility. Spinopelvic mobility was correlated with pelvic tilt as well as with lumbar flexibility. Conclusion: Around 13.4% of patients had spinopelvic mobility under 20° , indicating reduced spinopelvic mobility and risk of THA dislocation. Level of Evidence III, Retrospective Comparative Study.


Introdução: A redução da mobilidade espinopélvica tem sido associada com o risco de luxação da prótese total do quadril. Objetivos: Avaliar a mobilidade espinopélvica nos pacientes com artrose primária da articulação do quadril e com indicação de artroplastia total do quadril (ATQ), e a influência da contratura em flexão do quadril sobre a mobilidade espinopélvica. Métodos: Trinta pacientes adultos com artrose primária do quadril e indicação de ATQ foram avaliados por meio de parâmetros radiográficos (incidência pélvica, versão pélvica, inclinação do sacro, mobilidade da coluna lombar e mobilidade espinopélvica). Resultados: A mobilidade espinopélvica variou de 6,90 a 54,50 graus (média 32,79 ± 11,42), e foi estatisticamente maior no grupo de pacientes com contratura em flexão do quadril. Foi observado correlação entre a mobilidade espinopélvica e a versão pélvica e flexibilidade da coluna lombar. Conclusão: A mobilidade espinopélvica abaixo de 20 graus, que caracteriza a redução da mobilidade espinopélvica e risco aumentado de luxação ou impacto dos componentes da prótese total foi observada em 13,4% dos pacientes. Nível de Evidência III, Estudo Retrospectivo Comparativo.

9.
Rev Bras Ortop (Sao Paulo) ; 57(3): 375-383, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785130

RESUMO

Objective The present study aimed to develop and evaluate the use of customized guides in patients undergoing surgery to correct vertebral deformity with a pedicular fixation system. Methods Four patients with spinal deformity (three with idiopathic scoliosis and one with congenital kyphoscoliosis) underwent surgical treatment to correct the deformity with a pedicular fixation system. Prototypes of 3D cost guides were developed and evaluated using technical feasibility, accuracy, and radiation exposure. Results The present study included 85 vertebral pedicles in which pedicle screws were inserted into the thoracic spine (65.8%) and into the lumbar spine (34.2%). Technical viability was positive in 46 vertebral pedicles (54.1%), with 25 thoracic (54%) and 21 lumbar (46%). Technical viability was negative in 39 pedicles (45.9%), 31 of which were thoracic (79.5%), and 8 were lumbar (20.5%). In assessing accuracy, 36 screws were centralized (78.2%), of which 17 were in the thoracic (36.9%) and 19 in the lumbar spine (41.3%). Malposition was observed in 10 screws (21.7%), of which 8 were in the thoracic (17.4%) and 2 in the lumbar spine (4.3%). The average radiation record used in the surgical procedures was of 5.17 ± 0.72 mSv, and the total time of use of fluoroscopy in each surgery ranged from 180.3 to 207.2 seconds. Conclusion The customized guide prototypes allowed the safe preparation of the pilot orifice of the vertebral pedicles in patients with deformities with improved accuracy and reduced intraoperative radiation.

10.
Rev. Bras. Ortop. (Online) ; 57(3): 375-383, May-June 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1388029

RESUMO

Abstract Objective The present study aimed to develop and evaluate the use of customized guides in patients undergoing surgery to correct vertebral deformity with a pedicular fixation system. Methods Four patients with spinal deformity (three with idiopathic scoliosis and one with congenital kyphoscoliosis) underwent surgical treatment to correct the deformity with a pedicular fixation system. Prototypes of 3D cost guides were developed and evaluated using technical feasibility, accuracy, and radiation exposure. Results The present study included 85 vertebral pedicles in which pedicle screws were inserted into the thoracic spine (65.8%) and into the lumbar spine (34.2%). Technical viability was positive in 46 vertebral pedicles (54.1%), with 25 thoracic (54%) and 21 lumbar (46%). Technical viability was negative in 39 pedicles (45.9%), 31 of which were thoracic (79.5%), and 8 were lumbar (20.5%). In assessing accuracy, 36 screws were centralized (78.2%), of which 17 were in the thoracic (36.9%) and 19 in the lumbar spine (41.3%). Malposition was observed in 10 screws (21.7%), of which 8 were in the thoracic (17.4%) and 2 in the lumbar spine (4.3%). The average radiation record used in the surgical procedures was of 5.17 ± 0.72 mSv, and the total time of use of fluoroscopy in each surgery ranged from 180.3 to 207.2 seconds. Conclusion The customized guide prototypes allowed the safe preparation of the pilot orifice of the vertebral pedicles in patients with deformities with improved accuracy and reduced intraoperative radiation.


Resumo Objetivo O presente estudo teve como objetivo desenvolver e avaliar a utilização de guias personalizadas em pacientes submetidos a cirurgia para correção de deformidades vertebrais com sistema de fixação pedicular. Métodos Quatro pacientes com deformidade espinhal (três casos de escoliose idiopática e um caso de cifoescoliose congênita) foram submetidos a tratamento cirúrgico corretivo com sistema de fixação pedicular. Protótipos de guias tridimensionais foram desenvolvidos e avaliados quanto à viabilidade técnica, precisão e exposição à radiação. Resultados O presente estudo incluiu 85 pedículos vertebrais submetidos à inserção de parafusos pediculares na coluna torácica (65,8%) e na coluna lombar (34,2%). A viabilidade técnica foi positiva em 46 pedículos vertebrais (54,1%), sendo 25 torácicos (54%) e 21 lombares (46%). A viabilidade técnica foi negativa em 39 pedículos (45,9%), sendo 31 torácicos (79,5%) e 8 lombares (20,5%). Quanto à precisão, 36 parafusos foram centralizados (78,2%), sendo 17 na coluna torácica (36,9%) e 19 na coluna lombar (41,3%). O mau posicionamento foi observado em 10 parafusos (21,7%), sendo 8 na coluna torácica (17,4%) e 2 na coluna lombar (4,3%). A radiação média registrada nos procedimentos cirúrgicos foi de 5,17 ± 0,72 mSv, e o tempo total de uso da fluoroscopia em cada cirurgia variou de 180,3 a 207,2 segundos. Conclusão Os protótipos de guias personalizadas permitiram o preparo seguro do orifício piloto nos pedículos vertebrais em casos de deformidade, com maior precisão e menor exposição intraoperatória à radiação.


Assuntos
Humanos , Anormalidades Congênitas , Vértebras Torácicas/anormalidades , Fraturas Ósseas/cirurgia , Corpo Vertebral
11.
BMC Musculoskelet Disord ; 23(1): 430, 2022 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-35526034

RESUMO

BACKGROUND: Fibrillin-1 (FBN1) is an extracellular matrix glycoprotein essential to the structural component of microfibrils and FBN1 gene polymorphisms can be associated with adolescent idiopathic scoliosis (AIS) susceptibility. This study aimed to evaluate the potential role of the FBN1 rs12916536 polymorphism in AIS development or severity and the variation in Cobb angle in relation to patient's characteristics. METHODS: DNA from 563 subjects (185 AIS patients and 378 controls) were genotyped using a validated TaqMan allelic discrimination assay. A multivariate logistic regression model evaluated the association between polymorphism and AIS, using the adjusted odds ratios (OR) with their respective 95% confidence intervals (95% CI). A linear regression analysis evaluated the variation in Cobb angle according to the patient's age and body mass index (BMI). RESULTS: Among the AIS group there was a predominance of females (12:1), low or normal BMI (90%), 58% had a Cobb angle greater than 45° and 74% were skeletally mature. Age was a risk factor (4-fold) for curve progression higher than BMI (P < 0.001). The allelic frequency of the rs12916536 G > A polymorphism was 40% in controls and 31% in AIS cases; and this difference was statistically significant (P = 0.004). FBN1 rs12916536 GA + AA genotypes were associated with a lower risk of AIS susceptibility (OR = 0.58 and 95% CI = 0.35-0.98), after adjustment for age, sex and BMI. However, no significant differences were detected in polymorphism distribution with the severity of the disease (Cobb < 45° or ≥ 45°). CONCLUSION: Age was a risk factor for progression of the scoliotic curve and FBN1 rs12916536 polymorphism a protective factor for AIS susceptibility.


Assuntos
Fibrilina-1 , Escoliose , Adolescente , Estudos de Casos e Controles , Feminino , Fibrilina-1/genética , Humanos , Masculino , Polimorfismo de Nucleotídeo Único , Escoliose/diagnóstico por imagem , Escoliose/genética , Índice de Gravidade de Doença
12.
Int J Health Plann Manage ; 37(3): 1708-1721, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35170106

RESUMO

BACKGROUND: Readmission followed by surgery to treat spinal fractures has a substantial impact on patient care costs and reflects a hospital's quality standards. This article analyzes the factors associated with hospital readmission followed by surgery to treat spinal fractures. METHODS: This was a cross-sectional study with time-series analysis. For prediction analysis, we used Cox proportional hazards and machine-learning models, using data from the Healthcare Cost and Utilization Project, Inpatient Database from Florida (USA). RESULTS: The sample comprised 215,999 patients, 8.8% of whom were readmitted within 30 days. The factors associated with a risk of readmission were male sex (1.1 [95% confidence interval 1.06-1.13]) and >60 years of age (1.74 [95% CI: 1.69-1.8]). Surgeons with a higher annual patient volume presented a lower risk of readmission (0.61 [95% CI: 0.59-0.63]) and hospitals with an annual volume >393 presented a lower risk (0.92 [95% CI: 0.89-0.95]). CONCLUSION: Surgical procedures and other selected predictors and machine-learning models can be used to reduce 30-day readmissions after spinal surgery. Identification of patients at higher risk for readmission and complications is the first step to reducing unplanned readmissions.


Assuntos
Readmissão do Paciente , Fraturas da Coluna Vertebral , Estudos Transversais , Bases de Dados Factuais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fraturas da Coluna Vertebral/cirurgia
13.
Acta ortop. bras ; Acta ortop. bras;30(4): e249351, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1393780

RESUMO

ABSTRACT Introduction: Reduction of spinopelvic mobility is associated with an increased dislocation of total hip arthroplasty (THA). Objective: To assess 1) spinopelvic mobility in patients with primary hip osteoarthritis and THA indication and 2) the influence of hip flexion contracture on spinopelvic mobility. Methods: Thirty adult patients with primary hip osteoarthritis and THA indication were evaluated using radiographic parameters (pelvic incidence, pelvic tilt, sacral slope, lumbar flexibility, and spinopelvic mobility). Results: Spinopelvic mobility ranged from 6.90 a 54.50° (mean 32.79 ± 11.42) and the group of patients with hip flexion contracture had higher mobility. Spinopelvic mobility was correlated with pelvic tilt as well as with lumbar flexibility. Conclusion: Around 13.4% of patients had spinopelvic mobility under 20° , indicating reduced spinopelvic mobility and risk of THA dislocation. Level of Evidence III, Retrospective Comparative Study.


RESUMO Introdução: A redução da mobilidade espinopélvica tem sido associada com o risco de luxação da prótese total do quadril. Objetivos: Avaliar a mobilidade espinopélvica nos pacientes com artrose primária da articulação do quadril e com indicação de artroplastia total do quadril (ATQ), e a influência da contratura em flexão do quadril sobre a mobilidade espinopélvica. Métodos: Trinta pacientes adultos com artrose primária do quadril e indicação de ATQ foram avaliados por meio de parâmetros radiográficos (incidência pélvica, versão pélvica, inclinação do sacro, mobilidade da coluna lombar e mobilidade espinopélvica). Resultados: A mobilidade espinopélvica variou de 6,90 a 54,50 graus (média 32,79 ± 11,42), e foi estatisticamente maior no grupo de pacientes com contratura em flexão do quadril. Foi observado correlação entre a mobilidade espinopélvica e a versão pélvica e flexibilidade da coluna lombar. Conclusão: A mobilidade espinopélvica abaixo de 20 graus, que caracteriza a redução da mobilidade espinopélvica e risco aumentado de luxação ou impacto dos componentes da prótese total foi observada em 13,4% dos pacientes. Nível de Evidência III, Estudo Retrospectivo Comparativo.

14.
Coluna/Columna ; 20(4): 300-304, Oct.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1356187

RESUMO

ABSTRACT Objectives: To evaluate the complications of surgical treatment in a group of patients with spinal metastasis with epidural compression, undergoing surgical treatment. Methods: This is a comparative retrospective study (level of evidence III), which evaluated 96 patients with spinal metastases undergoing surgical treatment. Intra- and postoperative complications were obtained from the patients' medical records and correlated with the following clinical characteristics: tumor type, tumor location, neurological deficit, age, number of affected vertebrae, Tokuhashi scale, Tomita scale, Karnofsky performance scale, and type of approach. Results: Complications of surgical treatment were observed in 29 (30.20%) patients. Surgical wound infection was the most frequent complication, observed in 15% of patients. Conclusions: Surgical treatment of spinal metastases presents complications in about 30% of patients and their occurrence should be considered in the treatment planning, weighing the risks and benefits for achieving the treatment goals. Level III evidence; Retrospective Study.


RESUMO Objetivo: Avaliar as complicações do tratamento cirúrgico em grupo de pacientes com metástase da coluna vertebral, compressão epidural e submetidos ao tratamento cirúrgico. Métodos: Trata-se de estudo retrospectivo comparativo (nível de evidência III), que avaliou 96 pacientes com metástase da coluna vertebral, submetidos ao tratamento cirúrgico. As complicações intra e pós-operatórias foram obtidas dos prontuários dos pacientes e correlacionadas com características clínicas: tipo de tumor, localização do tumor, déficit neurológico, idade, número de vértebras acometidas, escala de Tokuhashi, escala de Tomita, escala de performance de Karnofsky e tipo de acesso. Resultados: As complicações do tratamento cirúrgico foram observadas em 29 (30,20%) pacientes. A infecção da ferida operatória foi a complicação mais frequente e observada em 15% dos pacientes. Conclusões: O tratamento cirúrgico das metástases da coluna vertebral apresenta complicações em cerca de 30% dos pacientes, e a sua ocorrência deve ser considerada na elaboração do tratamento frente aos riscos e benefícios para a obtenção dos objetivos do tratamento. Evidência nível III; Estudo Retrospectivo.


RESUMEN Objetivos: Evaluar las complicaciones del tratamiento quirúrgico en un grupo de pacientes con metástasis vertebrales, compresión epidural y sometidos a tratamiento quirúrgico. Métodos: Se trata de un estudio comparativo retrospectivo (nivel de evidencia III), que evaluó a 96 pacientes con metástasis en la columna vertebral sometidos a tratamiento quirúrgico. Las complicaciones intra y postoperatorias se obtuvieron de la historia clínica de los pacientes y se correlacionaron con las características clínicas: tipo de tumor, localización del tumor, déficit neurológico, edad, número de vértebras afectadas, escala de Tokuhashi, escala de Tomita, escala de rendimiento de Karnofsky y tipo de acceso. Resultados: Se observaron complicaciones del tratamiento quirúrgico en 29 (30,20%) pacientes. La infección de la herida quirúrgica fue la complicación más frecuente y se observó en el 15% de los pacientes. Conclusiones: El tratamiento quirúrgico de las metástasis de columna vertebral presenta complicaciones en aproximadamente el 30% de los pacientes, y su ocurrencia debe ser considerada en la elaboración del tratamiento, considerando los riesgos y beneficios para lograr los objetivos del mismo. Evidencia de nivel III; Estudio retrospectivo.


Assuntos
Humanos , Metástase Neoplásica
15.
Acta Ortop Bras ; 29(4): 203-206, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34566479

RESUMO

OBJECTIVE: Study the in vitro pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw), a screw pedicle designed to be inserted using a direct insertion technique. METHODS: DSG Screws of 5.5 mm and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16 g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. RESULTS: Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared to line-to-line tapping. CONCLUSION: DSG Screw showed the highest pullout strength after its insertion without pilot hole and tapping. Level of Evidence V, Expert Opinion.


OBJETIVO: Estudar a resistência ao arrancamento in vitro do parafuso de inserção direta da SpineGuard/Zavation (parafuso DSG), um parafuso pedicular projetado para ser inserido usando a técnica de inserção direta. MÉTODOS: Parafusos DSG de 5,5 mm e 6,5 mm foram introduzidos em blocos de poliuretano com densidade de 10 PCF (0,16 g/cm3). De acordo com o grupo experimental, os parafusos foram inseridos sem orifício piloto, com orifício e sem macheamento e macheamento diâmetro inferior com mesma geometria. Os testes de resistência dos parafusos foram realizados usando uma máquina de teste universal após a inserção dos parafusos nos blocos de poliuretano. RESULTADOS: Os parafusos inseridos diretamente nos blocos de poliuretano sem orifício piloto e sem macheamento apresentaram uma resistência de arrancamento com significância estatística maior. A inserção do parafuso sem macheamento ou com macheamento com diâmetro inferior apresenta maior resistência ao arrancamento em comparação com o macheamento do mesmo diâmetro. CONCLUSÃO: O parafuso DSG apresentou a maior resistência ao arrancamento após sua inserção sem orifício piloto e sem macheamento. Nível de Evidência V, Opinião do Especialista.

16.
Coluna/Columna ; 20(3): 169-173, July-Sept. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1339744

RESUMO

ABSTRACT Objective To present the preliminary results of the bipolar technique for the surgical treatment of neuromuscular spine deformities. Methods Five patients with neuromuscular scoliosis (cerebral palsy - 3 patients, spinal amyotrophy - 1 patient, and genetic syndrome - 1 patient) underwent surgical treatment using the bipolar technique and were evaluated 12 months after the operation. Results General care and the ability to sit improved in all patients. The main curve ranged from 64.7 to 84.1 degrees (mean 70.58 ± 7.1) in the preoperative period and from 2.6 to 50.3 degrees (mean 25.50 ± 16.0) in the postoperative period with 64% correction. Corrections of pelvic obliquity (85%), T4-T12 kyphosis (43%), the Pisa angle (69%) and the sacroclavicular angle (60%) were observed 12 months following surgery. Postoperative infection (2 patients) and pneumonia (1 patient) were the complications observed. Conclusion The bipolar technique presented good clinical and radiological results associated with low morbidity in the treatment of neuromuscular spine deformities. Level of evidence IV; Case series.


RESUMO Objetivo Apresentar os resultados preliminares da técnica bipolar no tratamento cirúrgico das deformidades neuromusculares da coluna vertebral. Métodos Cinco pacientes com escoliose neuromuscular (paralisia cerebral - três pacientes, amiotrofia espinhal - um paciente, e síndrome genética - um paciente) foram submetidos ao tratamento cirúrgico por meio da técnica bipolar e avaliados 12 meses depois da cirurgia. Resultados Os cuidados gerais e a capacidade de sentar apresentaram melhora em todos os pacientes. A curva principal variou de 64,7 a 84,1 graus (média 70,58 ± 7,1) no pré-operatório e de 2,6 a 50,3 graus (média 25,50 ± 16,0) no pós-operatório, com correção de 64%. A correção da obliquidade pélvica (85%), de cifose T4-T12 (43%), do ângulo de Pisa (69%) e do ângulo sacro clavicular (60%) foi observada depois de 12 meses de pós-operatório. Infecção pós-operatória (dois pacientes) e pneumonia (um paciente) foram as complicações observadas. Conclusão A técnica bipolar apresentou bons resultados clínicos e radiológicos associados a pequena morbidade no tratamento de deformidades neuromusculares da coluna vertebral. Nível de evidência IV; Série de casos.


RESUMEN Objetivo Presentar los resultados preliminares de la técnica bipolar en el tratamiento quirúrgico de las deformidades neuromusculares de la columna. Métodos Cinco pacientes con escoliosis neuromuscular (parálisis cerebral - 3 pacientes, amiotrofia espinal - 1 paciente y síndrome genético - 1 paciente) fueron sometidos a tratamiento quirúrgico mediante técnica bipolar y evaluados a los 12 meses de cirugía. Resultados Los cuidados generales y la capacidad de sentarse mejoraron en todos los pacientes. La curva principal osciló entre 64,7 y 84,1 grados (media 70,58 ± 7,1) en el preoperatorio y entre 2,6 y 50,3 grados (media 25,50 ± 16,0) en el postoperatorio con una corrección del 64%. La corrección de oblicuidad pélvica (85%), cifosis T4-T12 (43%), ángulo de Pisa (69%) y ángulo clavicular sacro (60%) se observó a los 12 meses del posoperatorio. Infección postoperatoria (2 pacientes) y neumonía (1 paciente) fueron las complicaciones observadas. Conclusión La técnica bipolar mostró buenos resultados clínicos y radiológicos asociados a la reducción de la morbilidad en el tratamiento de las deformidades neuromusculares de la columna. Nivel de evidencia IV; Serie de casos.


Assuntos
Humanos , Doenças Neuromusculares , Anormalidades Congênitas , Procedimentos Cirúrgicos Minimamente Invasivos
17.
Coluna/Columna ; 20(3): 156-160, July-Sept. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1339745

RESUMO

ABSTRACT Objective Evaluate and compare the mechanical resistance and the fatigue behavior associated with the use of three different modalities of vertebral fixation system rod connectors through in vitro pre-clinical mechanical tests developed specifically for this application (linear, lateral with square connector and lateral with oblique connector). Methods Cobalt chromium rods 5.5 mm in diameter were used and coupled with three types of connectors: a) side rod with oblique connector, b) side rod with square connector, and c) rod and linear connectors. Quasi-static mechanical four-point bending and fatigue tests were performed. The variables measured were (I) the bending moment at the yield limit, (II) the displacement at the yield limit, (III) the rigidity of the system in flexion and (IV) the number of cycles until system failure. Results The linear system presented the greatest force and the greatest moment at the yield limit, as well as the greatest stiffness equivalent to bending. All specimens with square and oblique connectors endured 2.5 million cycles in the minimum and maximum conditions of applied moment. The specimens with linear connector endured 2.5 million cycles with fractions of 40.14% of the bending moment at the yield limit, but failed with levels of 60.17% and 80.27%. Conclusions Systems with linear connectors showed greater mechanical resistance when compared to systems with square and oblique connectors. All systems supported cyclic loads that mimic in vivo demands. Level of evidence V; In vitro research.


RESUMO Objetivo Avaliar e comparar a resistência mecânica e o comportamento em fadiga associados ao uso de três modalidades distintas de conectores de hastes do sistema de fixação vertebral por meio de ensaios mecânicos pré-clínicos in vitro desenvolvidos especificamente para essa aplicação (linear, lateral com conector quadrado e lateral com conector oblíquo). Métodos Foram usadas hastes de Cromo-cobalto de 5,5 mm de diâmetro acopladas a três modalidades de conectores: a) haste lateral com conector oblíquo, b) haste lateral com conector quadrado e c) haste e conector lineares. Foram realizados ensaios mecânicos quase-estáticos e de fadiga sob flexão em quatro pontos. As variáveis medidas foram (I) o momento fletor no limite de escoamento, (II) o deslocamento no limite de escoamento e (III) a rigidez do sistema em flexão e (IV) número de ciclos até a falha do sistema. Resultados O sistema linear apresentou a maior força e o maior momento no limite de escoamento, bem como maior rigidez equivalente à flexão. Todos os corpos de prova com conectores quadrados e oblíquos suportaram 2,5 milhões de ciclos nas condições mínimas e máximas de momento aplicado. Os corpos de prova com conector linear suportaram 2,5 milhões de ciclos com frações de 40,14% do momento fletor no limite do escoamento, porém falharam com níveis de 60,17% e 80,27%. Conclusões Os sistemas com conectores lineares apresentaram maior resistência mecânica quando comparados aos sistemas com conectores quadrados e oblíquos. Todos os sistemas suportaram carregamentos cíclicos que mimetizam as solicitações in vivo. Nível de evidencia V; Pesquisa in vitro.


RESUMEN Objetivo Evaluar y comparar la resistencia mecánica y el comportamiento de fatiga asociado al uso de tres modalidades distintas de conectores de varilla del sistema de fijación vertebral a través de ensayos mecánicos preclínicos in vitro desarrollados específicamente para esta aplicación (lineal, lateral con conector cuadrado y lateral con conector oblicuo). Métodos Se utilizaron varillas de cromo-cobalto de 5,5 mm de diámetro acopladas a tres tipos de conectores: a) varilla lateral con conector oblicuo, b) varilla lateral con conector cuadrado y c) varilla y conector lineales. Se realizaron ensayos mecánicos y de fatiga cuasi-estáticos y ensayos por flexión de cuatro puntos. Las variables medidas fueron (I) el momento flector en el límite elástico, (II) el desplazamiento en el límite elástico y (III) la rigidez del sistema en flexión y (IV) el número de ciclos hasta la falla del sistema. Resultados El sistema lineal presentó la mayor fuerza y el mayor momento en el límite elástico, así como la mayor rigidez equivalente a la flexión. Todas las probetas con conectores cuadrados y oblicuos soportaron 2,5 millones de ciclos en las condiciones mínimas y máximas de momento aplicado. Las probetas con conector lineal soportaron 2,5 millones de ciclos con fracciones del 40,14% del momento flector en el límite elástico, pero fallaron con niveles de 60,17% y 80,27%. Conclusiones Los sistemas con conectores lineales mostraron mayor resistencia mecánica en comparación con los sistemas con conectores cuadrados y oblicuos. Todos los sistemas admitían cargas cíclicas que imitan las solicitudes in vivo. Nivel de Evidencia V; Investigación in vitro.


Assuntos
Humanos , Fusão Vertebral , Implantes Experimentais , Artrodese , Ensaio
18.
Acta ortop. bras ; Acta ortop. bras;29(4): 203-206, Aug. 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1339049

RESUMO

ABSTRACT Objective: Study the in vitro pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw), a screw pedicle designed to be inserted using a direct insertion technique. Methods: DSG Screws of 5.5 mm and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16 g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results: Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared to line-to-line tapping. Conclusion: DSG Screw showed the highest pullout strength after its insertion without pilot hole and tapping. Level of Evidence V, Expert Opinion.


RESUMO Objetivo: Estudar a resistência ao arrancamento in vitro do parafuso de inserção direta da SpineGuard/Zavation (parafuso DSG), um parafuso pedicular projetado para ser inserido usando a técnica de inserção direta. Métodos: Parafusos DSG de 5,5 mm e 6,5 mm foram introduzidos em blocos de poliuretano com densidade de 10 PCF (0,16 g/cm3). De acordo com o grupo experimental, os parafusos foram inseridos sem orifício piloto, com orifício e sem macheamento e macheamento diâmetro inferior com mesma geometria. Os testes de resistência dos parafusos foram realizados usando uma máquina de teste universal após a inserção dos parafusos nos blocos de poliuretano. Resultados: Os parafusos inseridos diretamente nos blocos de poliuretano sem orifício piloto e sem macheamento apresentaram uma resistência de arrancamento com significância estatística maior. A inserção do parafuso sem macheamento ou com macheamento com diâmetro inferior apresenta maior resistência ao arrancamento em comparação com o macheamento do mesmo diâmetro. Conclusão: O parafuso DSG apresentou a maior resistência ao arrancamento após sua inserção sem orifício piloto e sem macheamento. Nível de Evidência V, Opinião do Especialista.

19.
Rev Bras Ortop (Sao Paulo) ; 56(3): 360-367, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34239203

RESUMO

Objective To measure and document the clinical impact of the waiting time for surgical treatment of patients with spinal deformities in a quaternary center in Brazil. Methods In total, 59 patients with spinal deformity waiting for surgery on our hospital's list were evaluated to observe the impact of the waiting time on the progression of the deformity. Patient evaluation was performed using the SRS-22r questionnaire for health-related quality of life (HRQL) and radiographic images to evaluate the deformity of the spine at the time the patients were included in the waiting list and at the most recent appointment. The radiographic parameters selected for comparison were: Cobb angle of the primary and secondary curves, coronal alignment, apical vertebral translation, pelvic obliquity, sagittal vertebral axis, kyphosis (T5-T12), and lordosis (L1-S1). Results Low HRQL scores according to the SRS-22r questionnaire were observed in patients waiting for surgery. The radiographic parameters showed progression of the deformity on the initial evaluation when compared with the most recent follow-up evaluation. Conclusion The patients waiting for surgical treatment of spinal deformities in our center showed relatively low HRQL scores and radiographic progression of the deformity.

20.
Coluna/Columna ; 20(2): 78-83, Apr.-June 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1249663

RESUMO

ABSTRACT Objective: Cervical spondylotic myelopathy (CSM) is the main cause of spinal dysfunction in adults. The type of surgical approach to treatment is not well defined in the literature. The objective is to report the results obtained through isolated posterior decompression in patients with a previous indication of the combined approach for the treatment of cervical spondylotic myelopathy. Methods: This is a therapeutic study with level of evidence II, according to the Oxford classification table. Ten patients who underwent isolated posterior approach surgery for the treatment of cervical spondylotic myelopathy were evaluated through imaging and questionnaires (visual analog scale, mJOA-Br scale - Brazilian Portuguese version of the Modified Japanese Orthopedic Association Scale, and Neck Disability Index (NDI)), comparing pre- and postoperative results. Results: Late evaluation of the 10 patients was performed in the period ranging from 24 to 36 months (mean of 30.3 months ± 7.25) following surgery. The comparison of the clinical and radiological parameters in all patients showed a statistical difference in relation to the preoperative scales applied and to the degree of cervical lordosis (p <0.05), evidencing improvement after decompression and posterior fixation of the cervical spine. Conclusions: The isolated posterior approach (decompression, fixation and arthrodesis) allowed the clinical and radiological improvement of patients with cervical spondylotic myelopathy and who had an indication of the complementary anterior approach. Level of evidence II; Retrospective study.


RESUMO Objetivo: A mielopatia cervical espondilótica (MCE) é a principal causa de disfunção medular nos adultos. O tipo de abordagem cirúrgica para o tratamento não é bem definido na literatura. O objetivo é relatar os resultados obtidos por meio da descompressão posterior isolada nos pacientes com indicação prévia da abordagem combinada para o tratamento da mielopatia cervical espondilótica. Métodos: Trata-se de um estudo terapêutico com nível de evidência II, conforme a tabela de classificação Oxford. Dez pacientes submetidos apenas à abordagem cirúrgica posterior para tratamento de mielopatia cervical espondilótica foram avaliados por meio de exames de imagem e de questionários (escala visual analógica, escala mJOA-Br - Versão em Português da Escala Modificada da Sociedade Japonesa de Ortopedia e escala de incapacidade cervical - Neck Disability Index - NDI), comparando os resultados pré e pós-operatórios. Resultados: A avaliação tardia dos 10 pacientes foi realizada no período que variou de 24 a 36 meses (média de 30,3 meses ± 7,25) de pós-operatório. A comparação dos parâmetros clínicos e radiológicos em todos os pacientes mostrou diferença estatística com relação ao pré-operatório para as escalas aplicadas e para o grau de lordose cervical (p < 0,05), evidenciando a melhora depois da descompressão e da fixação posterior da coluna cervical. Conclusões: A abordagem posterior isolada (descompressão, fixação e artrodese) permitiu a melhora clínica e radiológica de pacientes com mielopatia cervical espondilótica e que tinham indicação da abordagem anterior complementar. Nível de evidência II; Estudo retrospectivo.


RESUMEN Objetivo: La mielopatía cervical espondilótica (MCE) es la principal causa de disfunción medular en los adultos. El tipo de abordaje quirúrgico para el tratamiento no está bien definido en la literatura. El objetivo es relatar los resultados obtenidos por medio de la descompresión posterior aislada en los pacientes con indicación previa del abordaje combinado para el tratamiento de la mielopatía cervical espondilótica. Métodos: Se trata de un estudio terapéutico con nivel de evidencia II, conforme a la tabla de clasificación Oxford. Diez pacientes sometidos únicamente al abordaje quirúrgico posterior para el tratamiento de la mielopatía cervical espondilótica fueron evaluados mediante exámenes de imagen y cuestionarios (escala analógica visual, escala mJOA-Br - versión en portugués de la escala modificada de la Sociedad Japonesa de Ortopedia y escala de incapacidad cervical - Neck Disability Index - NDI), comparando los resultados pre y postoperatorios. Resultados: La evaluación tardía de los 10 pacientes fue realizada en el período que varió de 24 a 36 meses (promedio de 30,3 meses ± 7,25) de postoperatorio. La comparación de los parámetros clínicos y radiológicos en todos los pacientes mostró diferencia estadística con relación al preoperatorio para las escalas aplicadas y para el grado de lordosis cervical (p <0,05), evidenciando la mejora después de la descompresión y de la fijación posterior de la columna cervical. Conclusiones: El abordaje posterior aislado (descompresión, fijación y artrodesis) permitió la mejora clínica y radiológica de pacientes con mielopatía cervical espondilótica y que tenían indicación del abordaje anterior complementario. Nivel de evidencia II; Estudio retrospectivo.


Assuntos
Humanos , Osteofitose Vertebral , Doenças da Medula Espinal , Vértebras Cervicais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA