1.
Light Sci Appl ; 13(1): 134, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849346

RESUMO

MINFLUX has achieved extraordinary resolution in superresolution imaging and single fluorophore tracking. It is based on localizing single fluorophores by rapid probing with a patterned beam that features a local intensity minimum. Current implementations, however, are complex and expensive and are limited in speed and robustness. Here, we show that a combination of an electro-optical modulator with a segmented birefringent element such as a spatial light modulator produces a variable phase plate for which the phase can be scanned on the MHz timescale. Bisected or top-hat phase patterns generate high-contrast compact excitation point-spread functions for MINFLUX localization in the x, y, and z-direction, respectively, which can be scanned across a fluorophore within a microsecond, switched within 60 microseconds and alternated among different excitation wavelengths. We discuss how to compensate for non-optimal performance of the components and present a robust 3D and multi-color MINFLUX excitation module, which we envision as an integral component of a high-performance and cost-effective open-source MINFLUX.

3.
Science ; 379(6636): 1010-1015, 2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36893247

RESUMO

Dynamic measurements of molecular machines can provide invaluable insights into their mechanism, but these measurements have been challenging in living cells. Here, we developed live-cell tracking of single fluorophores with nanometer spatial and millisecond temporal resolution in two and three dimensions using the recently introduced super-resolution technique MINFLUX. Using this approach, we resolved the precise stepping motion of the motor protein kinesin-1 as it walked on microtubules in living cells. Nanoscopic tracking of motors walking on the microtubules of fixed cells also enabled us to resolve the architecture of the microtubule cytoskeleton with protofilament resolution.


Assuntos
Células , Cinesinas , Microscopia de Fluorescência , Microtúbulos , Células/química , Células/metabolismo , Corantes Fluorescentes/análise , Cinesinas/química , Cinesinas/metabolismo , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Microtúbulos/química , Microtúbulos/metabolismo , Movimento (Física) , Humanos
4.
HardwareX ; 13: e00407, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36875260

RESUMO

Modern microscopy relies increasingly on microscope automation to improve throughput, ensure reproducibility or observe rare events. Automation requires computer control of the important elements of the microscope. Furthermore, optical elements that are usually fixed or manually movable can be placed on electronically-controllable elements. In most cases, a central electronics board is necessary to generate the control signals they require and to communicate with the computer. For such tasks, Arduino microcontrollers are widely used due to their low cost and programming entry barrier. However, they are limiting in their performance for applications that require high-speed or multiple parallel processes. Field programmable gate arrays (FPGA) are the perfect technology for high-speed microscope control, as they are capable of processing signals in parallel and with high temporal precision. While plummeting prices made the technology available to consumers, a major hurdle remaining is the complex languages used to configure them. In this work, we used an affordable FPGA, delivered with an open-source and friendly-to-use programming language, to create a versatile microscope control platform called MicroFPGA. It is capable of synchronously triggering cameras and multiple lasers following complex patterns, as well as generating various signals used to control microscope elements such as filter wheels, servomotor stages, flip-mirrors, laser power or acousto-optic modulators. MicroFPGA is open-source and we provide online Micro-Manager, Java, Python and LabVIEW libraries, together with blueprints and tutorials.

5.
Nat Commun ; 13(1): 3362, 2022 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-35690614

RESUMO

Modern implementations of widefield fluorescence microscopy often rely on sCMOS cameras, but this camera architecture inherently features pixel-to-pixel variations. Such variations lead to image artifacts and render quantitative image interpretation difficult. Although a variety of algorithmic corrections exists, they require a thorough characterization of the camera, which typically is not easy to access or perform. Here, we developed a fully automated pipeline for camera characterization based solely on thermally generated signal, and implemented it in the popular open-source software Micro-Manager and ImageJ/Fiji. Besides supplying the conventional camera maps of noise, offset and gain, our pipeline also gives access to dark current and thermal noise as functions of the exposure time. This allowed us to avoid structural bias in single-molecule localization microscopy (SMLM), which without correction is substantial even for scientific-grade, cooled cameras. In addition, our approach enables high-quality 3D super-resolution as well as live-cell time-lapse microscopy with cheap, industry-grade cameras. As our approach for camera characterization does not require any user interventions or additional hardware implementations, numerous correction algorithms that rely on camera characterization become easily applicable.


Assuntos
Algoritmos , Artefatos , Microscopia de Fluorescência/métodos , Fótons , Imagem Individual de Molécula
6.
Opt Express ; 29(20): 32169-32178, 2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34615294

RESUMO

The shape of an instance hole (keyhole) created via a high-power laser was measured using a low-coherence interferometer with the following parameters: repetition rate, 10 MHz; center wavelength, 1550 nm; absolute spatial resolution, 10 µm; and measurement range, 5 mm. The keyhole was created on a 3-mm-thick stainless-steel plate using a high-power laser with 8-kW peak power and 1070-nm center wavelength. The cross-sectional area of the keyhole was measured to be 0.42 mm × 0.78 mm (width × depth) using the interferometer, and its side dimension was 0.46 mm × 0.78 mm (width × depth).

7.
J Opt Soc Am A Opt Image Sci Vis ; 38(7): 1075-1084, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34263763

RESUMO

In image scanning microscopy, the pinhole of a confocal microscope is replaced by a detector array. The point spread function for each detector element can be interpreted as the probability density function of the signal, the peak giving the most likely origin. This thus allows a form of maximum likelihood restoration, and compensation for aberrations, with similarities to adaptive optics. As an example of an aberration, we investigate theoretically and experimentally illumination with a vortex doughnut beam. After reassignment and summation over the detector array, the point spread function is compact, and the resolution and signal level higher than in a conventional microscope.

8.
J Clin Pathol ; 74(2): 84-90, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32467319

RESUMO

AIM: Cathepsins are proteases that regulate a wide range of physiological processes, including protein turnover, cell signalling and antigen presentation. Recent studies have shown that cathepsins are highly upregulated in many types of tumours. Of the 15 cathepsins in humans, cathepsins V and S are abundantly expressed in the thymus, and we previously showed that the immunostaining of these cathepsins could serve as diagnostic markers for thymic epithelial tumours. However, little is known about the expression of other cathepsins in thymic epithelial tumours. To determine the diagnostic implications of cathepsins, we performed immunohistochemical analysis of cathepsin B (CTB), cathepsin D (CTD) and cathepsin K (CTK), all of which have been reported to correlate with the progression of squamous cell carcinoma. METHODS: The association between cathepsin expression and clinicopathological features was evaluated in 122 cases of thymoma and thymic carcinoma. RESULTS: CTB and CTD were frequently expressed in type A and type AB thymomas. In contrast, CTB and CTD were significantly less common in type B thymomas than in type A or AB thymomas. In type AB thymomas, the expression of CTB correlated with histological features, and was found predominantly in the type A component. Notably, CTK was expressed most commonly in thymic carcinomas, and patients who died of the disease showed increased expression of CTK. CONCLUSIONS: The expression of CTB and CTD correlated with the histological subtype of thymoma. In addition, the expression of CTK appears to be useful for the diagnosis of thymic carcinomas and as a prognostic marker.


Assuntos
Biomarcadores Tumorais/metabolismo , Catepsina B/biossíntese , Catepsina D/biossíntese , Catepsina K/biossíntese , Neoplasias Epiteliais e Glandulares/patologia , Neoplasias do Timo/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Epiteliais e Glandulares/metabolismo , Neoplasias do Timo/metabolismo , Adulto Jovem
9.
Biomed Opt Express ; 11(11): 6293-6310, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33282491

RESUMO

Dynamic biological systems present challenges to existing three-dimensional (3D) optical microscopes because of their continuous temporal and spatial changes. Most techniques are rigid in adapting the acquisition parameters over time, as in confocal microscopy, where a laser beam is sequentially scanned at a predefined spatial sampling rate and pixel dwell time. Such lack of tunability forces a user to provide scan parameters, which may not be optimal, based on the best assumption before an acquisition starts. Here, we developed volumetric Lissajous confocal microscopy to achieve unsurpassed 3D scanning speed with a tunable sampling rate. The system combines an acoustic liquid lens for continuous axial focus translation with a resonant scanning mirror. Accordingly, the excitation beam follows a dynamic Lissajous trajectory enabling sub-millisecond acquisitions of image series containing 3D information at a sub-Nyquist sampling rate. By temporal accumulation and/or advanced interpolation algorithms, the volumetric imaging rate is selectable using a post-processing step at the desired spatiotemporal resolution for events of interest. We demonstrate multicolor and calcium imaging over volumes of tens of cubic microns with 3D acquisition speeds of 30 Hz and frame rates up to 5 kHz.

10.
J Opt Soc Am A Opt Image Sci Vis ; 37(10): 1639-1649, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33104611

RESUMO

Image scanning microscopy is a technique of confocal microscopy in which the confocal pinhole is replaced by a detector array, and the image is reconstructed most straightforwardly by pixel reassignment. In the fluorescence mode, the detector array collects most of the fluorescent light, so the signal-to-noise ratio is much improved compared with confocal microscopy with a small pinhole, while the resolution is improved compared with conventional fluorescence microscopy. Here we consider two cases in which the illumination and detection point spread functions are dissimilar: illumination with a Bessel beam and multiphoton microscopy. It has been shown previously that for Bessel beam illumination in image scanning microscopy with a large array, the imaging performance is degraded. On the other hand, it is also known that the resolution of confocal microscopy is improved by Bessel beam illumination. Here we analyze image scanning microscopy with Bessel beam illumination together with a small array and show that an improvement in transverse resolution (width of the point spread function) by a factor of 1.78 compared with a conventional fluorescence microscope can be obtained. We also examine the behavior of image scanning microscopy in two- or three-photon fluorescence and for two-photon excitation also with Bessel beam illumination. The combination of the optical sectioning effect of image scanning microscopy with multiphoton microscopy reduces background from the sample surface, which can increase penetration depth. For a detector array size of two Airy units, the resolution of two-photon image scanning microscopy is a factor 1.85 better and the peak of the point spread function 2.84 times higher than in nonconfocal two-photon fluorescence. The resolution of three-photon image scanning microscopy is a factor 2.10 better, and the peak of the point spread function is 3.77 times higher than in nonconfocal three-photon fluorescence. The resolution of two-photon image scanning microscopy with Bessel beam illumination is a factor 2.13 better than in standard two-photon fluorescence. Axial resolution and optical sectioning in two-photon or three-photon fluorescence are also improved by using the image scanning modality.

11.
Mod Rheumatol Case Rep ; 4(1): 110-115, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-33086974

RESUMO

Gout, which is characterized by the deposition of monosodium urate monohydrate (MSU) in the synovial fluid and other tissues, is the most common form of inflammatory arthritis. Unlike the easily recognized acute and monoarticular gouty arthritis, advanced gout induces multiple finger joint disorders and may sometimes mimic rheumatoid arthritis (RA) or vice versa. The gold standard for gout diagnosis is the identification of MSU crystals via aspiration in the symptomatic joints or nodules; however, its feasibility and specificity may be inadequate. Recently, there have been important advances in imaging techniques, assisting in the non-invasive diagnosis of gout. Ultrasonography (US) has been known to have the ability to detect deposition of MSU crystals in patients with gout. Herein, we report an evocative case of long-standing gout with precisely detected specific US features indicating MSU crystal deposition and inflammation in multiple joints. Comprehensive US assessment included the bone, hyaline cartilage, soft tissue, subcutaneous nodules and tendon; we also discriminated gouty arthritis from RA.


Assuntos
Gota/diagnóstico , Gota/etiologia , Ultrassonografia , Ácido Úrico/efeitos adversos , Humanos , Cartilagem Hialina/patologia , Cristais Líquidos , Líquido Sinovial , Ultrassonografia/métodos
12.
J Opt Soc Am A Opt Image Sci Vis ; 37(1): 154-162, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32118893

RESUMO

Image scanning microscopy is a technique based on confocal microscopy, in which the confocal pinhole is replaced by a detector array, and the resulting image is reconstructed, usually by the process of pixel reassignment. The detector array collects most of the fluorescent light, so the signal-to-noise ratio is much improved compared with confocal microscopy with a small pinhole, while the resolution is improved compared with conventional (wide-field) microscopy. In previous studies, it has usually been assumed that pixels should be reassigned by a constant factor, to a point midway between the illumination and detection spots. Here it is shown that the peak intensity of the effective point spread function (PSF) can be further increased by 4% by a new choice of the pixel reassignment factor. For an array of two Airy units, the peak of the effective PSF is 1.90 times that of a conventional microscope, and the transverse resolution is 1.53 times better. It is confirmed that image scanning microscopy gives optical sectioning strength identical to that of a confocal microscope with a pinhole equal to the size of the detector array. However, it is shown that image scanning microscopy exhibits axial resolution superior to a confocal microscope with a pinhole the same size as the detector array. For a two-Airy-unit array, the axial resolution is 1.34 times better than in a conventional microscope for the standard reassignment factor, and 1.28 times better for the new reassignment factor. The axial resolution of a confocal microscope with a two-Airy-unit pinhole is only 1.04 times better than conventional microscopy. We also examine the signal-to-noise ratio of a point object in a uniform background (called the detectability), and show that it is 1.6 times higher than in a confocal microscope.

13.
ACS Nano ; 13(8): 9673-9681, 2019 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-31369704

RESUMO

The application of ultrafast pulsed laser sources and spectroscopic techniques enables label-free, deep-tissue optical microscopy. However, circumvention of the diffraction limit in this field is still an open challenge. Among such approaches, pump-probe microscopy is of increasing interest thanks to its highly specific nonfluorescent-based contrast mechanisms for the imaging of material and life science samples. In this paper, a custom femtosecond-pulsed near-infrared pump-probe microscope, which exploits transient absorption and stimulated Raman scattering interactions, is presented. The conventional pump-probe configuration is combined with a spatially shaped saturation pump beam, which allows for the reduction of the effective focal volume exploiting transient absorption saturation. By optimizing the acquisition parameters, such as power and temporal overlap of the saturation beam, we can image single-layer graphene deposited on a glass surface at the nanoscale and with increased layer sensitivity. These results suggest that saturation pump-probe nanoscopy is a promising tool for label-free high-resolution imaging.


Assuntos
Grafite/química , Microscopia/métodos , Imagem Molecular , Humanos , Lasers , Luz , Análise Espectral , Análise Espectral Raman
14.
Nat Commun ; 10(1): 3103, 2019 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-31308370

RESUMO

Fourier ring correlation (FRC) has recently gained popularity among fluorescence microscopists as a straightforward and objective method to measure the effective image resolution. While the knowledge of the numeric resolution value is helpful in e.g., interpreting imaging results, much more practical use can be made of FRC analysis-in this article we propose blind image restoration methods enabled by it. We apply FRC to perform image de-noising by frequency domain filtering. We propose novel blind linear and non-linear image deconvolution methods that use FRC to estimate the effective point-spread-function, directly from the images. We show how FRC can be used as a powerful metric to observe the progress of iterative deconvolution. We also address two important limitations in FRC that may be of more general interest: how to make FRC work with single images (within certain practical limits) and with three-dimensional images with highly anisotropic resolution.

15.
Nat Methods ; 16(2): 175-178, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30643212

RESUMO

Image scanning microscopy (ISM) can improve the effective spatial resolution of confocal microscopy to its theoretical limit. However, current implementations are not robust or versatile, and are incompatible with fluorescence lifetime imaging (FLIM). We describe an implementation of ISM based on a single-photon detector array that enables super-resolution FLIM and improves multicolor, live-cell and in-depth imaging, thereby paving the way for a massive transition from confocal microscopy to ISM.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Algoritmos , Animais , Biologia Computacional , Células HEK293 , Células HeLa , Humanos , Camundongos , Camundongos Transgênicos , Mitocôndrias/metabolismo , Poro Nuclear/metabolismo , Imagem Óptica , Fótons , Software , Tubulina (Proteína)/química
16.
Neuropharmacology ; 138: 232-244, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29913186

RESUMO

Since Cav3.2 T-type Ca2+ channels (T-channels) expressed in the primary afferents and CNS contribute to intractable pain, we explored T-channel-blocking components in distinct herbal extracts using a whole-cell patch-clamp technique in HEK293 cells stably expressing Cav3.2 or Cav3.1, and purified and identified sophoraflavanone G (SG) as an active compound from SOPHORAE RADIX (SR). Interestingly, hop-derived SG analogues, (2S)-6-prenylnaringenin (6-PNG) and (2S)-8-PNG, but not naringenin, also blocked T-channels; IC50 (µM) of SG, (2S)-6-PNG and (2S)-8-PNG was 0.68-0.75 for Cav3.2 and 0.99-1.41 for Cav3.1. (2S)-6-PNG and (2S)-8-PNG, but not SG, exhibited reversible inhibition. The racemic (2R/S)-6-PNG as well as (2S)-6-PNG potently blocked Cav3.2, but exhibited minor effect on high-voltage-activated Ca2+ channels and voltage-gated Na+ channels in differentiated NG108-15 cells. In mice, the mechanical allodynia following intraplantar (i.pl.) administration of an H2S donor was abolished by oral or i.p. SR extract and by i.pl. SG, (2S)-6-PNG or (2S)-8-PNG, but not naringenin. Intraperitoneal (2R/S)-6-PNG strongly suppressed visceral pain and spinal ERK phosphorylation following intracolonic administration of an H2S donor in mice. (2R/S)-6-PNG, administered i.pl. or i.p., suppressed the neuropathic allodynia induced by partial sciatic nerve ligation or oxaliplatin, an anti-cancer agent, in mice. (2R/S)-6-PNG had little or no effect on open-field behavior, motor performance or cardiovascular function in mice, and on the contractility of isolated rat aorta. (2R/S)-6-PNG, but not SG, was detectable in the brain after their i.p. administration in mice. Our data suggest that 6-PNG, a hop component, blocks T-channels, and alleviates neuropathic and visceral pain with little side effects.


Assuntos
Analgésicos não Narcóticos/farmacologia , Bloqueadores dos Canais de Cálcio/farmacologia , Flavonoides/farmacologia , Neuralgia/tratamento farmacológico , Dor Visceral/tratamento farmacológico , Analgésicos não Narcóticos/química , Analgésicos não Narcóticos/isolamento & purificação , Animais , Bloqueadores dos Canais de Cálcio/química , Bloqueadores dos Canais de Cálcio/isolamento & purificação , Canais de Cálcio Tipo T/genética , Canais de Cálcio Tipo T/metabolismo , Modelos Animais de Doenças , Flavonoides/química , Flavonoides/isolamento & purificação , Células HEK293 , Humanos , Humulus , Hiperalgesia/tratamento farmacológico , Hiperalgesia/metabolismo , Masculino , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Neuralgia/metabolismo , Compostos Fitoquímicos/química , Compostos Fitoquímicos/isolamento & purificação , Compostos Fitoquímicos/farmacologia , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Distribuição Aleatória , Ratos Wistar , Dor Visceral/metabolismo
17.
Chem Pharm Bull (Tokyo) ; 66(7): 741-747, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29695658

RESUMO

Hydroxychavicol (HC), which is obtained from the leaves of Piper betle LINN. (Piperaceae), inhibits xanthine oxidase (XO) with an IC50 value of 16.7 µM, making it more potent than the clinically used allopurinol (IC50=30.7 µM). Herein, a structure-activity relationship analysis of the polar part analogs of HC was conducted and an inhibitor was discovered with a potency 13 times that of HC. Kinetic studies have revealed that HC and its active analog inhibit XO in an uncompetitive manner. The binding structure prediction of these inhibitor molecules to the XO complex with xanthine suggested that both compounds (HC and its analog) could simultaneously form hydrogen bonds with xanthine and XO.


Assuntos
Inibidores Enzimáticos/química , Inibidores Enzimáticos/farmacologia , Eugenol/análogos & derivados , Simulação de Acoplamento Molecular , Xantina Oxidase/antagonistas & inibidores , Relação Dose-Resposta a Droga , Inibidores Enzimáticos/isolamento & purificação , Eugenol/química , Eugenol/isolamento & purificação , Eugenol/farmacologia , Humanos , Estrutura Molecular , Piperaceae/química , Folhas de Planta/química , Relação Estrutura-Atividade , Xantina Oxidase/metabolismo
18.
Small ; 14(5)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29251417

RESUMO

Development of fluorescent and electron dense markers is essential for the implementation of correlative light and electron microscopy, as dual-contrast landmarks are required to match the details in the multimodal images. Here, a novel method for correlative microscopy that utilizes fluorescent nanodiamonds (FNDs) as dual-contrast probes is reported. It is demonstrated how the FNDs can be used as dual-contrast labels-and together with automatic image registration tool SuperTomo, for precise image correlation-in high-resolution stimulated emission depletion (STED)/confocal and transmission electron microscopy (TEM) correlative microscopy experiments. It is shown how FNDs can be employed in experiments with both live and fixed cells as well as simple test samples. The fluorescence imaging can be performed either before TEM imaging or after, as the robust FNDs survive the TEM sample preparation and can be imaged with STED and other fluorescence microscopes directly on the TEM grids.

19.
J Cell Sci ; 130(18): 3094-3107, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28775156

RESUMO

Sharpin, a multifunctional adaptor protein, regulates several signalling pathways. For example, Sharpin enhances signal-induced NF-κB signalling as part of the linear ubiquitin assembly complex (LUBAC) and inhibits integrins, the T cell receptor, caspase 1 and PTEN. However, despite recent insights into Sharpin and LUBAC function, a systematic approach to identify the signalling pathways regulated by Sharpin has not been reported. Here, we present the first 'Sharpin interactome', which identifies a large number of novel potential Sharpin interactors in addition to several known ones. These data suggest that Sharpin and LUBAC might regulate a larger number of biological processes than previously identified, such as endosomal trafficking, RNA processing, metabolism and cytoskeleton regulation. Importantly, using the Sharpin interactome, we have identified a novel role for Sharpin in lamellipodium formation. We demonstrate that Sharpin interacts with Arp2/3, a protein complex that catalyses actin filament branching. We have identified the Arp2/3-binding site in Sharpin and demonstrate using a specific Arp2/3-binding deficient mutant that the Sharpin-Arp2/3 interaction promotes lamellipodium formation in a LUBAC-independent fashion.This article has an associated First Person interview with the first author of the paper.


Assuntos
Complexo 2-3 de Proteínas Relacionadas à Actina/metabolismo , Proteínas do Tecido Nervoso/metabolismo , Mapas de Interação de Proteínas , Pseudópodes/metabolismo , Movimento Celular , Citoesqueleto/metabolismo , Ontologia Genética , Células HeLa , Humanos , Espectrometria de Massas , Ligação Proteica , Imagem com Lapso de Tempo
20.
Mol Cell Biochem ; 432(1-2): 131-139, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28293874

RESUMO

Osteoclasts are multinucleated bone-resorbing cells with a dynamic actin cytoskeleton. Osteoclasts are derived from circulating mononuclear precursors. Confocal and stimulated emission depletion (STED) super-resolution microscopy was used to investigate peripheral blood-derived human osteoclasts cultured on glass surfaces. STED and confocal microscopy demonstrated that the actin was curved and branched, for instance, in the vicinity of membrane ruffles. The overall architecture of the curved actin network extended from the podosomes to the top of the cell. The other novel finding was that a micrometer-level tube containing actin bridged the osteoclasts well above the level of the culture glass. The actin filaments of the tubes originated from the network of curved actin often surrounding a group of nuclei. Furthermore, nuclei were occasionally located inside the tubes. Our findings demonstrated the accumulation of c-Src, cortactin, cofilin, and actin around nuclei suggesting their role in nuclear processes such as the locomotion of nuclei. ARP2/3 labeling was abundant at the substratum level of osteoclasts and in the branched actin network, where it localized to the branching points. We speculate that the actin-containing tubes of osteoclasts may provide a means of transportation of nuclei, e.g., during the fusion of osteoclasts. These novel findings can pave the way for future studies aiming at the elucidation of the differentiation of multinucleated osteoclasts.


Assuntos
Citoesqueleto de Actina/metabolismo , Actinas/metabolismo , Forma Celular , Microtúbulos/metabolismo , Osteoclastos/metabolismo , Células Cultivadas , Humanos , Osteoclastos/citologia
SELEÇÃO DE REFERÊNCIAS