Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-15135112

RESUMO

A simple high-performance liquid chromatographic method for the determination of dicloxacillin in plasma has been developed. The method only requires 0.5 ml of plasma, phosphate buffer solution (pH = 4.7), acidification with 0.5N hydrochloride acid and liquid extraction with dichloromethane. Posterior evaporation of organic under nitrogen steam and redissolution in mobile phase is carried out. The analysis was performed on a Spherisorb C18 (5 microm) column, using methanol -0.05 M phosphate buffer, pH = 4.7 (75:25; v/v) as mobile phase, with ultraviolet detection at 220 nm. Results showed that the assay is sensitive: 0.5 microg/ml. The response is linear in the range of 0.5 - 10 microg/ml. Maximum inter-day coefficient of variation was 12.4%. Mean extraction recovery obtained was 96.95%. Stability studies showed that the loss was not higher than 10%, samples are stable at room temperature for 6 h, at -20 Celsius for 2 months, processed samples were stable at least for 24 h and also after two freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in humans.


Assuntos
Antibacterianos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Dicloxacilina/sangue , Antibacterianos/farmacocinética , Dicloxacilina/farmacocinética , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta , Equivalência Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...