Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Ophthalmol ; : 11206721241261099, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38870390

RESUMO

PURPOSE: To compare the staining properties of Monoblue inner limiting membrane (ILM) View and Monoblue DUAL View (study products) vital stains during vitrectomy surgery to those of ILM Blue or Membrane Blue Dual (control products). METHODS: In this study, 105 patients were included in the Ophthalmic Clinic of the University Hospitals Leuven from September 2021 to April 2022. For prospective data collection in this study, patients were randomized between a control group (ILM Blue or Membrane Blue Dual, manufactured and commercialized by DORC®) and a study group (Monoblue ILM View or Monoblue DUAL View, manufactured and commercialized by Arcadophta®-BVI®). For retrospective data collection, patients were divided into similar surgery groups. Efficacy was analyzed using a binary subjective evaluation of the visualization of stained membranes during vitrectomy. The rate and severity of potential adverse events related to the study products were tracked, allowing both treatment groups to be compared with the corresponding control groups (ILM Blue and Membrane Blue Dual). RESULTS: Based on the results and findings, none of the comparisons (primary outcomes) were statistically significant, showing similar efficacy of the dyes used. The study products were found to be safe in this study since no serious adverse events were reported. CONCLUSIONS: The present findings indicate that the Monoblue ILM View and Monoblue DUAL View dyes can safely be used during vitrectomy to stain the ILM and/or epiretinal membrane (ERM) when removal is needed.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38602516

RESUMO

PURPOSE: To study the visual results and tolerance of a Zeiss CT Lucia 601P intraocular lens (IOL) implanted in the sulcus after complicated cataract surgery or during IOL exchange for clouded IOL. METHODS: In total, 64 patients who underwent sulcus implantation were recalled to the hospital to undergo subjective and objective refraction, best corrected visual acuity measurement, tonometry, optical coherence tomography, laser flare photometry, biometry, and wavefront aberrometry. RESULTS: In spite of a large variation in preoperative refraction, the target refraction was obtained within 1.5 diopters in approximately 97% of patients and within 0.5 diopter in 53% of patients. Average BCVA was high (Snellen 0.86) and related to concomitant (mostly retinal) pathologies in eyes with poorer visual performance. Wavefront aberrometry showed no evidence of IOL tilting or decentration after long-term implantation in the sulcus. Tonometry was not different from the fellow eye of the patient (p > 0.5). In 53 patients with bilateral pseudophakia, the laser flare photometry was not significantly different from the fellow eye (p < 0.05). CONCLUSION: This study demonstrates that this single-piece angulated foldable acrylic IOL can be considered for implantation in the sulcus. The visual results are favorable, and the IOL can be well-positioned and tolerated in the sulcus. Moreover, there were no safety issues found since there was no evidence of elevated IOP or chronic uveitis.

3.
Graefes Arch Clin Exp Ophthalmol ; 261(12): 3465-3474, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37584791

RESUMO

PURPOSE: To report patient satisfaction after unilateral/bilateral extended depth-of-focus (EDOF) intraocular lens (IOL) implantation in a young population after vitrectomy. METHODS: Patients that underwent phaco-vitrectomy or phaco following vitrectomy with an AT LARA EDOF IOL, aged between 18 and 75 years, were asked to fill out a questionnaire to assess overall visual quality, near vision quality, and visual disturbances. The questionnaire was based on the Catquest, NAVQ, and APPLES questionnaires. RESULTS: A total of 89 participants (average age 56.7 years) filled out the questionnaire of which 53.9% received a unilateral EDOF IOL. The most common indications for vitrectomy were retinal detachments (38.2%), floaters (36.0%), and epiretinal membranes (16.9%). The Catquest and NAVQ score respectively showed a good overall satisfaction (3.44/4.0), a good intermediate vision (3.55/4.0), and an average near vision (2.75/4.0). The APPLES score showed acceptable visual disturbances. There were no differences between the unilateral and bilateral group, except for a higher spectacle dependency in the unilateral group (40% vs. 10.6%). Participants that underwent vitrectomy in case of floaters reported lower satisfaction rates. Other variables, like the pre-operative refraction, had no impact on both satisfaction and visual disturbances. CONCLUSION: Both unilateral and bilateral implantation of the AT LARA EDOF IOL showed a high satisfaction with no differences between both groups, except for a lower spectacle use in the latter. Hence, The AT LARA seems to be a possible choice in patients undergoing vitrectomy at a younger age, even for unilateral use.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Acuidade Visual , Satisfação do Paciente , Percepção de Profundidade , Refração Ocular , Desenho de Prótese , Pseudofacia
4.
Melanoma Res ; 25(3): 200-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25756553

RESUMO

To further elucidate the genetic underpinnings of uveal melanoma (UM) and identify new markers that correlate with disease outcome, archival formalin-fixed, paraffin-embedded enucleation specimens from 25 patients with UM and a mean follow-up of 14 years were analyzed for whole-genome copy-number alterations using OncoScan analysis. Copy-number alterations of chromosomes 1, 3, 6, and 8 were also analyzed in these tumors using multiplex ligation-dependent probe-amplification, and mutations in GNAQ, GNA11, and BAP1 were searched for by Sanger sequencing. Our study confirms the previously reported GNAQ and GNA11 mutation frequencies in UMs as well as the presence of monosomy 3 as a factor strongly indicating poor prognosis. Two cases with metastatic disease, but without monosomy of chromosome 3, showed loss of a small region in the distal part of chromosome 2p. Also, UMs leading to metastatic disease had more chromosomal aberrations than those without metastases. Three UMs lacking a GNAQ or a GNA11 mutation showed a gain of chromosome 8q; one of these cases showed extensive chromothripsis. Another case (with suspect lung metastasis) showed focal chromothripsis. Our whole-genome copy-number analysis shows that focal loss of chromosome 2p may be involved in the metastatic spread of UMs without monosomy 3; metastatic UMs carry more chromosomal aberrations than those without metastases; and chromothripsis may play a role in the oncogenesis of UMs, but does not necessarily indicate a poor prognosis. The clinical and particularly diagnostic utility of these findings needs to be corroborated in a larger set of patients with UM.


Assuntos
Carcinogênese , Aberrações Cromossômicas , Variações do Número de Cópias de DNA , Melanoma/genética , Modelos Genéticos , Neoplasias Uveais/genética , Centros Médicos Acadêmicos , Adulto , Idoso , Corioide/metabolismo , Corioide/patologia , Corpo Ciliar/metabolismo , Corpo Ciliar/patologia , Feminino , Seguimentos , Estudo de Associação Genômica Ampla , Humanos , Masculino , Melanoma/diagnóstico , Melanoma/metabolismo , Melanoma/patologia , Melanoma/secundário , Pessoa de Meia-Idade , Mutação , Países Baixos , Prognóstico , Estudos Retrospectivos , Translocação Genética , Neoplasias Uveais/diagnóstico , Neoplasias Uveais/metabolismo , Neoplasias Uveais/patologia
5.
Ned Tijdschr Geneeskd ; 158: A7813, 2014.
Artigo em Holandês | MEDLINE | ID: mdl-25308223

RESUMO

In the nineteen-nineties, there was much hype in the European media about presumed laser pointer maculopathy. However, the recent introduction of more powerful and therefore more dangerous laser pointers and their easy availability on the internet necessitates vigilance on the issue. This is an urgent matter, as here we report three cases of proven maculopathy due to an unsafe laser pointer. Three boys aged 13, 9 and 12 years used an unsafe laser pointer as a toy and looked repeatedly into the pointer, resulting in a permanent reduction in visual acuity due to macular damage. Laser pointers are not designed to be children's toys or instruments to annoy people in a crowd. Health authorities and the ophthalmic community should be aware of the potential danger of improper use of high-output laser pointers and warn the general public before the widespread availability of unsafe laser pointers and consequently laser pointer-induced macular damage becomes a true social problem.


Assuntos
Traumatismos Oculares/etiologia , Lasers/efeitos adversos , Acuidade Visual , Adolescente , Conscientização , Criança , Humanos , Internet , Degeneração Macular/etiologia , Masculino , Jogos e Brinquedos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...