Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neth Heart J ; 21(11): 485-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24150598
2.
Neth Heart J ; 14(6): 232-238, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25696642
4.
J Am Coll Cardiol ; 30(3): 780-3, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9283540

RESUMO

OBJECTIVES: We sought to establish the diagnostic accuracy of transesophageal echocardiography (TEE) during cardiopulmonary resuscitation. BACKGROUND: Because of its bedside diagnostic capabilities, excellent cardiac images and lack of interference with resuscitation efforts, TEE is ideally suited to determine the cause of a circulatory arrest that is not due to severe arrhythmia. However, the diagnostic accuracy of TEE during resuscitation is unknown. METHODS: TEE was performed in patients with prolonged circulatory arrest. The TEE diagnoses were compared with diagnoses from autopsy, surgery and clinical follow-up. RESULTS: Of the 48 study patients (29 male, 19 female, mean age +/- SD 61 +/- 20 years), 28 had an in-hospital cardiac arrest and 20 an out-of-hospital onset of arrest. Forty-four patients eventually died; four survived to discharge. The diagnoses made with TEE were cardiac tamponade (n = 6), myocardial infarction (n = 21), pulmonary embolism (n = 6), ruptured aorta (n = 1), aortic dissection (n = 4), papillary muscle rupture (n = 1), other diagnosis (n = 2) and absence of structural cardiac abnormalities (n = 7). A definite diagnosis from a reference standard was available in 31 patients. The TEE diagnosis was confirmed in 27 of the 31-by postmortem examination (n = 19), operation (n = 2), angiography (n = 2) or clinical course (n = 4). In the other four patients the TEE diagnosis proved incorrect by postmortem examination. The sensitivity, specificity and positive predictive value of TEE were 93%, 50% and 87%, respectively. In 15 patients (31%), major therapeutic decisions were based on TEE findings. CONCLUSIONS: TEE can reliably establish the cause of a circulatory arrest during cardiopulmonary resuscitation.


Assuntos
Tamponamento Cardíaco/diagnóstico por imagem , Reanimação Cardiopulmonar , Ecocardiografia Transesofagiana , Parada Cardíaca/etiologia , Infarto do Miocárdio/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Tamponamento Cardíaco/complicações , Feminino , Parada Cardíaca/diagnóstico por imagem , Parada Cardíaca/terapia , Ruptura Cardíaca/complicações , Ruptura Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Valor Preditivo dos Testes , Embolia Pulmonar/complicações , Sensibilidade e Especificidade
6.
Am Heart J ; 131(5): 865-71, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8615303

RESUMO

The pathogenesis of mitral regurgitation (MR) was determined by quantitative echocardiography in 188 patients with acute myocardial infarction (AMI) within 48 hours after admission. MR was classified, by using color Doppler, as significant (grades 3 to 4) or trivial (grades 0 to 2). Left ventricular (LV) function (global and regional), volume, and shape, as well as mitral valvular features, were measured and analyzed by stepwise logistic regression. Significant MR occurred in 25 (13%) patients. Univariately, recurrent infarction (p < 0.01), LV dilation (p < 0.001) and sphericity (p < 0.001), inferoposterolateral asynergy (p < 0.001), mitral annular dilatation (p < 0.005), and mitral leaflet restriction (p < 0.05) were associated with significant MR. In regression analysis, only recurrent infarction (odds ratio 5.08), LV sphericity index (odds ratio 1.12), and inferoposterolateral asynergy (odds ratio 6.07) were independently associated with significant MR, whereas none of the mitral valvular features examined had an independent association. In conclusion, changes in LV shape and regional function and not mitral valvular changes are prime determinants of significant MR after AMI.


Assuntos
Insuficiência da Valva Mitral/etiologia , Infarto do Miocárdio/complicações , Idoso , Análise de Variância , Ecocardiografia Doppler em Cores , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Infarto do Miocárdio/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
7.
J Hum Hypertens ; 10(1): 9-15, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8642194

RESUMO

The objective of this study was to assess the value of two substitutes for ambulatory blood pressure (BP) monitoring: nurse-measured BP and BP measured by an automated device during 1 h resting in the clinic (basal BP). Hypertensive patients in an academic out-patients clinic were selected consecutively. We compared the relation of indices of early target organ damage (echocardiographically determined left ventricular mass index (LVMI) and urinary albumin excretion (expressed as albumin/creatinine ratio: ACR) to physician measured and nurse measured basal and ambulatory BP. The relation of BP to LVMI and the logACR were also studied for both sexes separately. Sixty-two patients (28 men, 34 women) were included, all untreated for >3 months. Systolic office BP was not significantly related to the LVMI (r2 = 0.04, P > 0.05), whereas nurse measured (r2 = 0.11, P < 0.05), basal (r2 = 0.13, P < 0.01) and ambulatory daytime (r2 = 0.13, P < 0.05) and night time (r2 = 0.17, p < 0.001) SBP did have a significant relation to LVMI. There was no difference in the relation of office, nurse, basal or ambulatory BP to logACR. In contrast to the highly significant relation of SBP to LVMI for male patients (day: r2 = 0.29, P < 0.01, night: r2 = 0.46, P < 0.001) this relation was non-existent for female patients (day: r2 = 0.09, P > 0.05, night: r2 = 0.02, P > 0.05). The relation between BP and logACR did not differ between the sexes. We conclude that: (1) to some degree nurse measured and basal BP may be considered as better predictors of early hypertensive target organ damage than physician measured BP; and (2) there is a pronounced sex difference in the relation of BP to left ventricular mass.


Assuntos
Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Adolescente , Adulto , Idoso , Albuminúria , Instituições de Assistência Ambulatorial , Determinação da Pressão Arterial/enfermagem , Monitorização Ambulatorial da Pressão Arterial , Creatinina/urina , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Médicos , Caracteres Sexuais
8.
Eur J Cardiothorac Surg ; 10(7): 513-20, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8855422

RESUMO

OBJECTIVES: In the mitral annulus bi-leaflet mechanical valves can be oriented in two ways: the anatomical orientation with the hinge line parallel to a line through the commissures of the native valve (90 degrees). The influence of this orientation on the left ventricular spatial flow pattern and valve leaflet opening was investigated in pigs. METHODS: In 9 pigs a CarboMedics mitral valve prosthesis was implanted in the ) degree position and in 9 pigs in the 90 degree orientation. Two dimensional echocardiographic and color Doppler recordings were performed before surgery, immediately after surgery and after 6 weeks. RESULTS: In the native valve the diastolic flow pattern was characterized by a central inflow and backflow away from the apex along the left ventricular wall. In the 0 degree orientation a diastolic flow pattern with an asymmetrical inflow was observed, resulting from a greater extension of the jet along the lateral wall compared to the jet along the interventricular septum. Mid-diastolic back-flow away from the left ventricular apex was directed towards the valve prosthesis. In the 2-dimensional echocardiographic recordings the opening angle of both prosthetic leaflets was different showing a larger opening angle of the posterior leaflet. In the 90 degree orientation a diastolic flow pattern with paradoxical flow directions was recorded, that could only be explained in a 3-dimensional way: one inflow jet along the anterior wall, one inflow jet along the posterior wall and back-flow away from the apex sandwiched in between the two inflow jets. In this orientation the 2-dimensional echocardiographic recordings showed symmetrical opening of the two leaflets of the prosthesis. CONCLUSIONS: The orientation of the CarboMedics bi-leaflet mechanical valve prosthesis in the mitral valve annulus determines the left ventricular spatial flow pattern. The flow pattern resulting from the 0 degree orientation, was associated with asymmetrical leaflet motion, while the 90 degree orientation flow pattern was associated with symmetrical leaflet motion. These findings may be of importance for prosthetic valve function as well as for left ventricular kinetics.


Assuntos
Próteses Valvulares Cardíacas , Função Ventricular Esquerda/fisiologia , Animais , Diástole , Ecocardiografia , Ecocardiografia Doppler em Cores , Valva Mitral , Suínos
9.
Am J Cardiol ; 76(16): 1112-4, 1995 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-7484893

RESUMO

Transesophageal atrial stimulation (TRAS) was combined with 2-dimensional echocardiography in 69 consecutive patients on days 3 to 5 (mean 3.3) of their first, uncomplicated myocardial infarction, to determine if inducible remote asynergy (i.e., not directly adjacent to the infarcted area and supposedly related to another vascular territory) provides information regarding (1) extent of coronary artery disease, and (2) future ischemic events. Uncomplicated, adequate stress studies were performed in 59 of 69 patients (86%); all these patients had regional asynergy at rest. Remote asynergy at rest was present in 7 patients and during TRAS in 26 patients. Coronary angiography was performed within 2 to 3 weeks after the acute phase. Multivessel disease was present in 23 of these patients and absent in 3. Of the 33 patients without remote asynergy during TRAS, 5 had multivessel disease. Sensitivity of remote asynergy during TRAS for detecting multivessel CAD was 82%, specificity 90%, and predictive accuracy 86%. New ischemic events, defined as recurrent infarction, cardiac death, or revascularization within 12 to 18 months (mean 12.6) occurred in 24 patients (41%); remote asynergy during TRAS was present in 16 of these patients (67%). It is concluded that TRAS combined with 2-dimensional echocardiography can safely be performed in the early days of acute myocardial infarction; remote asynergy during TRAS reliably identifies patients with multivessel disease and future ischemic events.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Infarto do Miocárdio/diagnóstico , Adulto , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo
11.
J Am Coll Cardiol ; 25(6): 1341-6, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7722131

RESUMO

OBJECTIVES: The value of Doppler-derived left ventricular spatial flow patterns in predicting left ventricular thrombus formation after myocardial infarction was compared with that of conventional clinical and echocardiographic variables. BACKGROUND: Assessment of left ventricular thrombosis risk after myocardial infarction is important because of potential embolic sequelae that are reduced by oral anticoagulant agents. METHODS: Clinical, two-dimensional and Doppler echocardiographic data were prospectively obtained in 104 patients with acute myocardial infarction within 48 h of admission. Ventricular flow was assessed by Doppler echocardiography and considered normal when brisk ventricular inflow with simultaneous onset at the mitral valve and apical levels was present, together with alternating directions of apical flow throughout the cardiac cycle. In addition to normal flow, two abnormal flow patterns were recognized: apical rotating flow and vortex ring formation. Oral anticoagulant agents were prescribed only to patients with abnormal flow at admission. The incidence of left ventricular thrombosis was assessed by echocardiography during 9 months of follow-up. RESULTS: Abnormal flow pattern had a positive predictive value of 63% and a negative predictive value of 99%. On stepwise logistic regression analysis, only abnormal flow pattern had an independent relation to left ventricular thrombus (odds ratio 92). CONCLUSIONS: Left ventricular flow pattern derived by Doppler echocardiography soon after admission is superior to conventional clinical and two-dimensional echocardiographic assessment in estimating the risk of left ventricular thrombosis after myocardial infarction.


Assuntos
Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/complicações , Trombose/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler em Cores , Eletrocardiografia , Seguimentos , Cardiopatias/etiologia , Cardiopatias/fisiopatologia , Cardiopatias/prevenção & controle , Heparina/uso terapêutico , Humanos , Modelos Logísticos , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Trombose/etiologia , Trombose/fisiopatologia , Trombose/prevenção & controle , Função Ventricular Esquerda
12.
J Inflamm ; 45(3): 193-206, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8597874

RESUMO

In the present study the protective effect of a recombinant endotoxin-binding protein rBPI23 on the circulatory changes in experimental endotoxemia in humans was investigated. In a controlled, blinded crossover study, eight volunteers were challenged twice with an intravenous bolus injection of endotoxin (40 EU/kg body weight), and concurrently received either rBPI23 (1 mg/kg) or placebo (human serum albumin, 0.2 mg/kg). Hemodynamic parameters were obtained non-invasively by means of M-mode, two-dimensional, and Doppler echocardiography. rBPI23 significantly reduced indices of the endotoxin-induced hyperdynamic circulation. rBPI23 treatment significantly reduced increase in cardiac index (P = 0.0156). rBPI23 treatment diminished the endotoxin-induced decrease in systemic vascular resistance index (P = 0.0304). rBPI23 did not prevent the endotoxin-induced rise in body temperature and systolic, diastolic and mean arterial pressure were not significantly different in the rBPI23- and placebo-treatment arm. Both treatment periods showed a small reduction in end diastolic and end systolic volumes. rBPI23 treatment slightly reduced the increase in M-mode ejection fraction and fractional shortening. These results indicate that rBPI23 is capable of attenuating the potentially deleterious circulatory effects of endotoxin in humans.


Assuntos
Endotoxinas/farmacologia , Hemodinâmica , Proteínas de Membrana/farmacologia , Adulto , Pressão Sanguínea , Débito Cardíaco , Endotoxinas/sangue , Frequência Cardíaca , Humanos , Masculino , Proteínas de Membrana/uso terapêutico , Proteínas Recombinantes/farmacologia , Volume Sistólico , Temperatura , Resistência Vascular
13.
Pediatr Cardiol ; 15(5): 225-8, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7997426

RESUMO

Transmitral flow was studied using Doppler echocardiography with the A/E ratio as a parameter of left ventricular diastolic function in 21 patients (ages 2.5-30.0 years) who had undergone early surgical correction of an isolated secundum type atrial septal defect (ASD) compared to a healthy cohort of 21 subjects. Pre- and postoperative M-mode recordings were compared in 12 of the 21 patients to evaluate the effect of operation on interventricular septal motion (IVS) and left ventricular (LV) and right ventricular (RV) end-diastolic diameter ratio (LVDD/RVDD) as parameters of right ventricular volume overload. No significant difference in A/E ratio was found between the patient and control groups. IVS was shown to normalize in 11 of 12 patients postoperatively and to improve from paradox to flattened in 1 of 12. LVDD/RVDD increased from 1.26 +/- 0.31 to 2.10 +/- 0.51 (p = 0.0008), with no significant difference remaining between the control and patient groups postoperatively. These findings support the conclusion that an intrinsic abnormality of the left ventricle is not responsible for its diastolic dysfunction in patients with ASD who develop left ventricular failure, thereby implicating an acquired abnormality. Mechanical sequelae of right ventricular volume overload were shown to normalize in all patients subsequent to operation in the present study, and therefore cannot be excluded as a cause of left ventricular failure in ASD.


Assuntos
Comunicação Interatrial/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia Doppler , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Humanos
15.
J Card Surg ; 9(2 Suppl): 255-61, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8186578

RESUMO

An endoscope was used to study the anatomy and morphology of the native mitral valve inside an isolated pig heart working under physiological conditions. Annulus motion, valve leaflet function, and the anatomy of the chords and branching pattern are described. Anatomical and functional details relevant to mitral valve reconstruction and valve replacement are outlined. Because of the similarity with the human heart, we have assumed that the observations made in the pig heart also apply to humans.


Assuntos
Valva Mitral/anatomia & histologia , Valva Mitral/cirurgia , Adulto , Animais , Cordas Tendinosas/anatomia & histologia , Cordas Tendinosas/fisiologia , Vasos Coronários/anatomia & histologia , Endoscopia , Feminino , Átrios do Coração/anatomia & histologia , Septos Cardíacos/anatomia & histologia , Ventrículos do Coração/anatomia & histologia , Humanos , Masculino , Valva Mitral/fisiologia , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/fisiopatologia , Contração Miocárdica/fisiologia , Músculos Papilares/anatomia & histologia , Músculos Papilares/fisiologia , Suínos
16.
Am J Cardiol ; 71(11): 976-81, 1993 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-8465792

RESUMO

Transesophageal echocardiography was performed in 46 healthy subjects to define characteristics of normal left atrial appendage blood flow. Three different flow wave patterns were observed that were heart rate dependent (p < 0.01). A quadriphasic pattern, consisting of 2 diastolic forward (emptying) flow waves each followed by a backward (filling) flow wave, was present in 36 subjects (78%). Triphasic appendage flow was observed in 6 subjects (13%) and biphasic flow in 4 (9%). Mean heart rates among subjects with quadri-, tri- and biphasic flows were 75 +/- 11, 95 +/- 6 and 112 +/- 7 beats/min, respectively. Analysis of pulsed Doppler recordings of subjects with quadriphasic or triphasic appendage flow patterns showed that the onset of transmitral early diastolic peak flow wave was followed at 17 +/- 15 ms by the onset of pulmonary venous diastolic flow and at 43 +/- 17 ms by the onset of the first diastolic forward flow in the appendage. This sequence was constant and independent of heart rate (p < 0.01), suggesting a causal relation between left ventricular relaxation and the first diastolic forward flow wave in the appendage. The second diastolic forward flow followed the P wave on the electrocardiogram at 79 +/- 23 ms. Thus, left atrial appendage blood flow pattern in normal subjects is heart rate dependent, and ventricular relaxation appears to initiate early diastolic emptying of the appendage.


Assuntos
Função Atrial , Adulto , Velocidade do Fluxo Sanguíneo , Ecocardiografia/métodos , Ecocardiografia Doppler , Feminino , Átrios do Coração/diagnóstico por imagem , Frequência Cardíaca , Humanos , Masculino , Veias Pulmonares/fisiologia , Fluxo Sanguíneo Regional/fisiologia
17.
J Am Soc Echocardiogr ; 5(3): 274-6, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1622619

RESUMO

An 80-year-old woman was evaluated by transesophageal echocardiography after coronary artery bypass surgery and subsequent cardioembolic stroke. In addition to spontaneous echo contrast demonstrating a counterclockwise rotating blood flow pattern, we observed free vortex ring formation in the left atrium, originating in the left auricle. To our knowledge, this is the first reported case of abnormal free vortex ring type flow pattern in the left atrium.


Assuntos
Ecocardiografia , Átrios do Coração/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fluxo Sanguíneo Regional
18.
J Am Coll Cardiol ; 15(2): 355-60, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2299076

RESUMO

The predictive value of the left ventricular spatial flow pattern for thrombus formation was determined in 62 patients with acute myocardial infarction. A normal flow pattern by pulsed Doppler echocardiography was characterized by 1) simultaneous onset of blood motion at the mitral valve and apical level, and 2) a discontinuous Doppler signal along the lateral wall and interventricular septum. The flow pattern was assessed by these criteria, within 24 h after the onset of complaints and after 6 and 12 weeks. In 46 of the 62 patients, a normal flow pattern was found at the first examination; none of these 46 patients developed a thrombus during the study period. An abnormal flow pattern was seen at the first examination in 16 patients; this pattern normalized during follow-up in 6 patients, none of whom developed a thrombus. In the other 10 patients the abnormal flow pattern persisted, and 7 of these developed a thrombus. These findings suggest that a normal left ventricular flow pattern in the setting of acute myocardial infarction is not associated with subsequent thrombus formation. This observation may be of importance if anticoagulation is considered.


Assuntos
Doença das Coronárias/etiologia , Trombose Coronária/etiologia , Infarto do Miocárdio/complicações , Idoso , Anticoagulantes/uso terapêutico , Circulação Coronária , Trombose Coronária/fisiopatologia , Trombose Coronária/prevenção & controle , Ecocardiografia Doppler , Feminino , Seguimentos , Previsões , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Biomech ; 23(6): 607-15, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2341422

RESUMO

This study employs classical inviscid fluid dynamics theory to investigate whether LV diastolic inflow volume and the size of the LV play a role in vortex ring formation. Fluid injection across an orifice into a large container results in the generation of a vortex ring having a constant size and speed. Relations between the vortex size and speed and the injection were obtained by applying conservation laws regarding kinetic energy, impulse and vorticity; the initial state was computed using a bolus injection model, and the final state by using the Kelvin vortex model. An important parameter in the equations is the relative injection length, i.e., the ratio of the length of the injected bolus and the radius of the orifice (L/R). Its estimated highest value in man, L/R = 15, produces a rather thick vortex ring (relative thickness 0.77). Comparable results following from the Hill vortex model convinced us that the Kelvin vortex model can be applied in the whole range of injection lengths in the human left ventricle. In an in vitro model it is shown experimentally that vortex rings can be generated for L/R in the range from 2 to 16. The measured traveling speed of the vortex ring is in fair agreement with the theory, as well as the ring radius for large injections. A vortex ring located in a narrow channel cannot reach its proper traveling speed. The method of images is used to estimate the speed reduction of vortex rings within a cylinder. It turns out that propagation of vortex rings is possible when the ratio of orifice to cylinder radius is less than about 0.5.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Modelos Cardiovasculares , Função Ventricular , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Diástole/fisiologia , Hemodinâmica , Humanos
20.
Int J Card Imaging ; 5(4): 241-8, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2121844

RESUMO

To assess the relation between early Indium-111 monoclonal antimyosin antibody scintigraphy and degree of regional asynergy on discharge, 38 patients with a first acute myocardial infarct were studied (18 anterior, 20 inferoposterior infarctions). In 21 patients thrombolytic therapy was administered. On the first day of myocardial infarction, 80 MBq Indium-111 Antimyosin was injected. Planar images, anterior, lateral and left anterior oblique, were made 24 hours later. Localized myocardial uptake was present in 37/38 patients, and was evaluated for Count Density Index (count density of infarct zone/left lung count density) in the left anterior oblique images, which displayed the infarct zone well. Regional asynergy on discharge was evaluated by cross-sectional echocardiography and defined mild (hypokinesia) or severe (akinesia or dyskinesia). Count density index was significantly lower in 15 patients with mild asynergy, compared with 22 patients with severe asynergy (1.61 +/- 0.25 vs. 2.42 +/- 0.40, p less than 0.001). This difference was present in both patient groups treated with or without thrombolysis. We conclude that early count density index, reflecting the amount of local necrosis, is highly correlated to the ultimate degree of wall motion impairment.


Assuntos
Anticorpos Monoclonais , Radioisótopos de Índio , Infarto do Miocárdio/diagnóstico por imagem , Miosinas/imunologia , Compostos Organometálicos , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Infarto do Miocárdio/tratamento farmacológico , Cintilografia , Estreptoquinase/uso terapêutico , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...