Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 99(3): 1055-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25742828

RESUMO

A 22-year-old patient with neurofibromatosis type 1 presented with acute chest pain. A computed tomography scan and coronary angiography revealed a partially thrombosed huge aneurysm of the left main coronary artery. Despite medical treatment, the patient's angina recurred. The patient underwent a coronary bypass grafting operation and surgical exclusion of the aneurysm. Postoperative imaging disclosed good permeability of the 3 coronary artery bypass grafts and complete thrombosis of the excluded aneurysm.


Assuntos
Aneurisma Coronário/etiologia , Neurofibromatose 1/complicações , Aneurisma Coronário/patologia , Aneurisma Coronário/cirurgia , Ponte de Artéria Coronária , Humanos , Masculino , Adulto Jovem
2.
J Thorac Cardiovasc Surg ; 148(5): 1903-11, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24685376

RESUMO

OBJECTIVE: Stentless xenograft bioprostheses may be the future valve of choice for aortic valve replacement. The study aim was to investigate the long-term clinical outcome after aortic valve replacement with the Medtronic Freestyle bioprosthesis (Medtronic Inc, Minneapolis, Minn). METHODS: Between April 1997 and November 2004, a total of 500 patients (mean age, 74.5±9.6 years; 52% were male) underwent aortic valve replacement with a Freestyle bioprosthesis, without population selection. The surgical procedure used a modified subcoronary technique in 479 patients and a complete root replacement in 21 patients, conducted with mini-extracorporeal circulation. Concomitant procedures included coronary artery bypass grafting in 122 patients (24%) and mitral valve repair/replacement in 11 patients. RESULTS: The mean cardiopulmonary bypass time was 98±26 minutes, and total aortic crossclamp time was 77±19 minutes. Operative mortality was 5.2%. The median follow-up time was 104.8±5.7 months. During this period, there were 224 deaths (n=122 cardiovascular and n=102 noncardiovascular deaths). The actuarial survivals from cardiovascular and valve-related mortality were 67%±3% and 70%±4%, respectively, at 10 years. Freedom from structural valve deterioration at 10 years was 94%±2%. The linearized structural valve deterioration incidence was 0.6% per patient/year. Multivariate Cox regression analysis revealed that older age, impaired renal function, and coronary artery disease were independent predictors of cardiovascular death. In the subgroup of patients aged less than 65 years at implantation (n=45), the actuarial cardiovascular survival was 83%±8% and freedom from structural valve deterioration was 89%±6% at 10 years. CONCLUSIONS: The use of the Freestyle bioprosthesis for aortic valve replacement resulted in good long-term cardiovascular survival and freedom from structural valve deterioration in this cohort regardless of age at implantation.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Ponte Cardiopulmonar , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Duração da Cirurgia , Complicações Pós-Operatórias/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Heart Valve Dis ; 15(2): 247-52, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16607908

RESUMO

BACKGROUND AND AIM OF THE STUDY: Stentless bioprostheses may be the future valve of choice for aortic valve replacement (AVR). The study aim was to investigate mid-term clinical outcome after AVR with the Medtronic Freestyle valve. METHODS: Between April 1997 and November 2004, a total of 500 patients (241 females, 259 males) was implanted with a Freestyle bioprosthesis for AVR, without population selection, by a single surgical team at the authors' institutions. Mean patient age was 74.5 +/- 9.6 years (range: 26-91 years); 34 patients (7%) were aged < 60 years, 121 (24%) were aged > 80 years, and 205 (41%) were in NYHA classes III or IV. The surgical procedure used included a modified subcoronary technique in 482 cases and complete root replacement in 18, conducted with mini-extracorporeal circulation. Concomitant procedures included coronary artery bypass grafting in 123 patients (25%), mitral valve repair/replacement in five, and maze in two. Follow up was 98% complete; the mean follow up was 31.3 months (range: 4-95 months). RESULTS: The mean cardiopulmonary bypass time was 98 +/- 26 min, and total aortic cross-clamp time 77 +/- 19 min. Operative mortality was 5.2% (n = 26), and no patients aged under 60 years died. At eight years, freedom from structural valve deterioration was 100% (0% in the young population), freedom from endocarditis 97.2%, freedom from reoperation 97%, and overall survival 83%. Most of the late deaths (n = 56) were of non-cardiac origin, and occurred in older patients. After one year, the mean aortic echocardiographic gradient was 11.5 +/- 1.1 mmHg, and was improved compared to that at discharge. No significant aortic insufficiency occurred. CONCLUSION: Use of the Freestyle stentless bioprosthesis for AVR resulted in excellent short-term survival in the octogenarian population, and excellent mid-term results in the younger population. In time, experience will indicate whether the Freestyle should be considered as the bioprosthesis of choice for patients of all ages.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...