Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 83(22): 8566-74, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21992470

RESUMO

According to the Italian laws, some categories of workers entrusted with duties possibly constituting a threat to security, physical safety, and health of third parties have to be screened to exclude the use/abuse of the following drugs of abuse: opiates, cocaine, cannabinoids, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, methadone, and buprenorphine. Toxicological tests can be performed with urinary on-site rapid screening devices, provided that sensitivities up to specified cutoffs are ensured. The present study reports performances, in terms of sensitivity, specificity, and accuracy, of an automatic on-site test and of an FPIA-based device, using gas chromatography/mass spectrometry (GC/MS) as a reference methodology. Three levels of concentration were tested, corresponding to the cutoff and to 2 and 3 times the limits, respectively. In terms of sensitivities, neither the on-site nor the benchtop instrumentations gave positive results, since values of zero percentage were obtained for concentrations up to 2-fold the limits. Even if good results were obtained in terms of specificity and accuracy by both devices, none of them seem to be adequate for the current application to the toxicological screening at workplaces. In fact, a rapid screening device can be used for drug tests provided that it ensures sensitivity at the prescribed cutoffs. Data showed that such is completely rejected and a more sensitive instrumentation should be preferred.


Assuntos
Drogas Ilícitas/urina , Detecção do Abuso de Substâncias/métodos , Imunoensaio de Fluorescência por Polarização/instrumentação , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Itália , Sensibilidade e Especificidade , Local de Trabalho
2.
Rapid Commun Mass Spectrom ; 24(1): 49-56, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19957293

RESUMO

Ketamine is an anaesthetic compound used in human and veterinary medicine with hallucinogen properties that have resulted in its increased illicit use by teenagers at rave parties. Although several gas chromatography/mass spectrometry (GC/MS) methods have been reported for the quantification of the drug both in urine and in hair, its electron ionization (EI) fragmentation after derivatization with different reagents has been not yet fully investigated. The present work reports the study of the fragmentation of ketamine, derivatized with heptafluorobutyric anhydride (HFBA-Ket), using gas chromatography/electron ionization mass spectrometry (GC/EI-MS). The complete characterization of the fragmentation pattern represented an intriguing exercise and required tandem mass spectrometry (MS(n)) experiments, high-resolution accurate mass measurements and the use of deuterated d(4)-ketamine to corroborate the proposed structures and to characterize the fragment ions carrying the unchanged aromatic moiety. Extensive fragmentation was observed, mainly located at the cyclohexanone ring followed by rearrangement of the fragment ions, as confirmed by the mass spectra obtained from the deuterated molecule. The GC/EI-MS analysis of HFBA-Ket will represent a useful tool in forensic science since high-throughput analyses are enabled, preserving both the GC stationary phase and the cleanliness of the mass spectrometer ion optics.


Assuntos
Algoritmos , Fluorocarbonos/análise , Fluorocarbonos/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Ketamina/análise , Ketamina/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Gases/análise , Gases/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...