1.
Med Dosim ; 46(3): 253-258, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33685768

RESUMO

BACKGROUND AND PURPOSE: There are several alternatives to the widespread ITV strategy in order to account for breathing-induced motion in PTV margins. The most sophisticated one includes the generation of a motion-compensated CT scan with the CTV placed in its average position - the mid-position approach (MidP). In such configuration, PTV margins integrate breathing as another random error. Despite overall irradiated volume reduction, such approach is barely used in clinical practice because of its dependence to deformable registration and its unavailability in commercial treatment planning systems. As an alternative, the mid-ventilation approach (MidV) selects the phase in the 4D-CT scan that is the closest to the MidP, with a residual error accounted for in the PTV margin. We propose a treatment planning system-integrated strategy, aiming at better approximating the MidP approach without its drawbacks: Hybrid MidV-MidP approach, i.e., the delineation on the MidV-CT and translation at the mid-position coordinates using treatment planning system built-in capabilities. MATERIAL AND METHODS: Forty-five lung lesions treated with stereotactic radiotherapy were selected. PTV was defined using MidP, MidV, Hybrid MidV-MidP and ITV strategies. Margin definitions were adapted and resulting PTVs were compared. RESULTS: Hybrid MidV-MidP showed similar target volume and location than the MidP and confirmed that margin-incorporated tumor motion strategies lead to significantly smaller PTVs than the ITV with mean reduction of 26 ± 7%. CONCLUSION: We report on the successful implementation of a pseudo-MidP solution without its inherent drawbacks. It answers the need for TPS-embedded tumor motion range identification and related margin's component calculation.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Estudos de Viabilidade , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/radioterapia , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador , Respiração
2.
Z Med Phys ; 31(2): 192-202, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33726960

RESUMO

PURPOSE: The aims of this work are to study the response of a small-gap plane-parallel ionization chamber in the presence of charge multiplication and suggest an experimental method to determine the product of the recombination correction factor (ks) and the charge multiplication correction factor (kCM) in order to investigate the latter. METHODS: Experimental data were acquired in scanned proton beams and in a Cobalt-60 beam. Measurements were carried out using an IBA PPC05 chambers of which the electrode gap is 0.6mm. The study is based on the determination of Jaffé plots by operating the chambers at different voltages. Experimental results are compared to theoretical equations describing initial and volume recombination as well as charge multiplication for continuous and pulsed beams. RESULTS: Results obtained in protons and Cobalt-60 with the same PPC05 chamber indicate that the charge multiplication effect is independent of the beam quality, while results obtained in different proton beams with two different PPC05 chambers show that the charge multiplication effect is chamber dependent. CONCLUSIONS: The approach to be taken when using a small-gap plane-parallel ionization chamber with a high voltage (e.g. 300V or 500V) for reference dosimetry in scanned proton beams depends on which correction factors were applied to the chamber response during its calibration in terms of absorbed dose to water: In both cases, it is recommended to use the ionization chamber at the same operating voltage used during its ND,w-calibration. Another solution consists of operating the PPC05 chamber at a lower voltage (e.g. 50V) with larger ks and smaller kCM and determining the product of both factors with higher accuracy using a linear extrapolation method.


Assuntos
Prótons , Radiometria , Calibragem , Água
3.
Strahlenther Onkol ; 194(6): 591-599, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29450589

RESUMO

PURPOSE: By increasing lung volume and decreasing respiration-induced tumour motion amplitude, administration of continuous positive airway pressure (CPAP) during stereotactic ablative radiotherapy (SABR) could allow for better sparing of the lungs and heart. In this study, we evaluated the effect of CPAP on lung volume, tumour motion amplitude and baseline shift, as well as the dosimetric impact of the strategy. METHODS: Twenty patients with lung tumours referred for SABR underwent 4D-computed tomography (CT) scans with and without CPAP (CPAP/noCPAP) at two timepoints (T0/T1). First, CPAP and noCPAP scans were compared for lung volume, tumour motion amplitude, and baseline shift. Next, CPAP and noCPAP treatment plans were computed and compared for lung dose parameters (mean lung dose (MLD), lung volume receiving 20 Gy (V20Gy), 13 Gy (V13Gy), and 5 Gy (V5Gy)) and mean heart dose (MHD). RESULTS: On average, CPAP increased lung volume by 8.0% (p < 0.001) and 6.3% (p < 0.001) at T0 and T1, respectively, but did not change tumour motion amplitude or baseline shift. As a result, CPAP administration led to an absolute decrease in MLD, lung V20Gy, V13Gy and V5Gy of 0.1 Gy (p = 0.1), 0.4% (p = 0.03), 0.5% (p = 0.04) and 0.5% (p = 0.2), respectively, while having no significant influence on MHD. CONCLUSIONS: In patients referred for SABR for lung tumours, CPAP increased lung volume without modifying tumour motion or baseline shift. As a result, CPAP allowed for a slight decrease in radiation dose to the lungs, which is unlikely to be clinically significant.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Movimentos dos Órgãos/fisiologia , Radiometria , Tomografia Computadorizada por Raios X
4.
Strahlenther Onkol ; 193(10): 812-822, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28733723

RESUMO

AIM: The aim of the study was to assess the feasibility of an individualized 18F fluorodeoxyglucose positron emission tomography (FDG-PET)-guided dose escalation boost in non-small cell lung cancer (NSCLC) patients and to assess its impact on local tumor control and toxicity. PATIENTS AND METHODS: A total of 13 patients with stage II-III NSCLC were enrolled to receive a dose of 62.5 Gy in 25 fractions to the CT-based planning target volume (PTV; primary turmor and affected lymph nodes). The fraction dose was increased within the individual PET-based PTV (PTVPET) using intensity modulated radiotherapy (IMRT) with a simultaneous integrated boost (SIB) until the predefined organ-at-risk (OAR) threshold was reached. Tumor response was assessed during follow-up by means of repeat FDG-PET/computed tomography. Acute and late toxicity were recorded and classified according to the CTCAE criteria (Version 4.0). Local progression-free survival was determined using the Kaplan-Meier method. RESULTS: The average dose to PTVPET reached 89.17 Gy for peripheral and 75 Gy for central tumors. After a median follow-up period of 29 months, seven patients were still alive, while six had died (four due to distant progression, two due to grade 5 toxicity). Local progression was seen in two patients in association with further recurrences. One and 2-year local progression free survival rates were 76.9% and 52.8%, respectively. Three cases of acute grade 3 esophagitis were seen. Two patients with central tumors developed late toxicity and died due to severe hemoptysis. CONCLUSION: These results suggest that a non-uniform and individualized dose escalation based on FDG-PET in IMRT delivery is feasible. The doses reached were higher in patients with peripheral compared to central tumors. This strategy enables good local control to be achieved at acceptable toxicity rates. However, dose escalation in centrally located tumors with direct invasion of mediastinal organs must be performed with great caution in order to avoid severe late toxicity.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Idoso , Fracionamento da Dose de Radiação , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Centrada no Paciente/métodos , Compostos Radiofarmacêuticos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Resultado do Tratamento
5.
Phys Med ; 31(8): 963-968, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26386892

RESUMO

PURPOSE: Tomotherapy MV-CT acquisitions of lung tumors lead to artifacts due to breathing-related motion. This could preclude the reliability of tumor based positioning. We investigate the effect of these artifacts on automatic registration and determine conditions under which correct positioning can be achieved. MATERIALS AND METHODS: MV-CT and 4D-CT scans of a dynamic thorax phantom were acquired with various motion amplitudes, directions, and periods. For each acquisition, the average kV-CT image was reconstructed from the 4D-CT data and rigidly registered with the corresponding MV-CT scan in a region of interest. Different kV-MV registration strategies have been assessed. RESULTS: All tested registration methods led to acceptable registration errors (within 1.3 ± 1.2 mm) for motion periods of 3 and 6 s, regardless of the motion amplitude, direction, and phase difference. However, a motion period of 5 s, equal to half the Tomotherapy gantry period, induced asymmetric artifacts within MV-CT and significantly degraded the registration accuracy. CONCLUSIONS: As long as the breathing period differs from 5 s, positioning based on averaged images of the tumor provides information about its daily baseline shift, and might therefore contribute to reducing margins, regardless of the registration method.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Movimento , Radioterapia de Intensidade Modulada , Automação , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Respiração , Rotação
6.
Radiother Oncol ; 110(3): 529-37, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24424385

RESUMO

PURPOSE: To compare the mid-position (MidP) strategy to the conventional internal target volume (ITV) for lung tumor management in helical TomoTherapy, using 4D Monte Carlo (MC) plan simulations. MATERIALS AND METHODS: For NSCLC patients treated by SBRT (n = 8) or SIB-IMRT (n = 7), target volumes and OARs were delineated on a contrast-enhanced CT, while 4D-CT was used to generate either ITV or MidP volumes with deformable registrations. PTV margins were added. Conformity indexes, volumetric and dosimetric parameters were compared for both strategies. Dose distributions were also computed using a 4D MC model (TomoPen) to assess how intra-fraction tumor motion affects tumor coverage, with and without interplay effect. RESULTS: PTVs derived from MidP were on average 1.2 times smaller than those from ITV, leading to lower doses to OARs. Planned dose conformity to TVs was similar for both strategies. 4D MC computation showed that ITV ensured adequate TV coverage (D95 within 1% of clinical requirements), while MidP failed in 3 patients of the SBRT group (D95 to the TV lowered by 4.35%, 2.16% and 2.61%) due to interplay effect in one case and to breathing motion alone in the others. CONCLUSIONS: Compared to the ITV, the MidP significantly reduced PTV and doses to OARs. MidP is safe for helical delivery except for very small tumors (<5 cc) with large-amplitude motion (>10mm) where the ITV might remain the most adequate approach.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Radioterapia de Intensidade Modulada , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Método de Monte Carlo , Movimento (Física) , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Respiração
7.
Radiother Oncol ; 104(2): 173-80, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22841518

RESUMO

PURPOSE: To evaluate the impact of intra-fraction motion induced by regular breathing on treatment quality for helical tomotherapy treatments. MATERIAL AND METHODS: Four patients treated by simultaneous-integrated boost (SIB) and three by hypo-fractionated stereotactic treatments (hypo-fractionated, 18 Gy/fraction) were included. All patients were coached to ensure regular breathing. For the SIB group, the tumor volume was delineated using CT information only (CTV(CT)) and the boost region was based on PET information (GTV(PET), no CTV extension). In the hypo-fractionated group, a GTV based on CT information was contoured. In both groups, ITVs were defined according to 4D data. The PTV included the ITV plus a setup error margin. The treatment was planned using the tomotherapy TPS on 3D CT images. In order to verify the impact of intra-fraction motion and interplay effects, dose calculations were performed using a previously validated Monte Carlo model of tomotherapy (TomoPen): first on the planning 3D CT ("planned dose") and second, on the 10 phases of the 4D scan. For the latter, two dose distributions, termed "interplay simulated" or "no interplay" were computed with and without beamlet-phase correlation over the 10 phases and combined using deformable dose registration. RESULTS: In all cases, DVHs of "interplay simulated" dose distributions complied within 1% of the original clinical objectives used for planning, defined according to ICRU (report 83) and RTOG (trials 0236 and 0618) recommendations, for SIB and hypo-fractionated groups, respectively. For one patient in the hypo-fractionated group, D(mean) to the CTV(CT) was 2.6% and 2.5% higher than "planned" for "interplay simulated" and "no interplay", respectively. CONCLUSION: For the patients included in this study, assuming regular breathing, the results showed that interplay of breathing and tomotherapy delivery motions did not affect significantly plan delivery accuracy. Hence, accounting for intra-fraction motion through the definition of an ITV volume was sufficient to ensure tumor coverage.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Técnicas de Imagem de Sincronização Respiratória , Tomografia Computadorizada Espiral , Adenocarcinoma/patologia , Adenocarcinoma de Pulmão , Idoso , Artefatos , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Estadiamento de Neoplasias , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Medição de Risco , Estudos de Amostragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...