EJNMMI Phys ; 3(1): 19, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27562024

RESUMO

The search for novel image contrasts has been a major driving force in the magnetic resonance (MR) research community, in order to gain further information on the body's physiological and pathological conditions.Chemical exchange saturation transfer (CEST) is a novel MR technique that enables imaging certain compounds at concentrations that are too low to impact the contrast of standard MR imaging and too low to directly be detected in MRS at typical water imaging resolution. For this to be possible, the target compound must be capable of exchanging protons with the surrounding water molecules. This property can be exploited to cause a continuous buildup of magnetic saturation of water, leading to greatly enhanced sensitivity.The goal of the present review is to introduce the basic principles of CEST imaging to the general molecular imaging community. Special focus has been given to the comparison of state-of-the-art CEST methods reported in the literature with their positron emission tomography (PET) counterparts.

3.
Clin Radiol ; 71(7): 660-72, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27108800

RESUMO

Integrated positron-emission tomography and computed tomography (PET/CT) is one of the most important imaging techniques to have emerged in oncological practice in the last decade. Hybrid imaging, in general, remains a rapidly growing field, not only in developing countries, but also in western industrialised healthcare systems. A great deal of technological development and research is focused on improving hybrid imaging technology further and introducing new techniques, e.g., integrated PET and magnetic resonance imaging (PET/MRI). Additionally, there are several new PET tracers on the horizon, which have the potential to broaden clinical applications in hybrid imaging for diagnosis as well as therapy. This article aims to highlight some of the major technical and clinical advances that are currently taking place in PET/CT and PET/MRI that will potentially maintain the position of hybrid techniques at the forefront of medical imaging technologies.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/tendências , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Previsões , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Phys Med Biol ; 58(7): 2267-80, 2013 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-23478566

RESUMO

Among the proposed system architectures capable of delivering positron emission tomography/magnetic resonance (PET/MR) datasets, tri-modality systems open an interesting field in which the synergies between these modalities can be exploited to address some of the problems encountered in standalone systems. In this paper we present a feasibility study of the correction of dental streak artifacts in computed tomography (CT)-based attenuation correction images using complementary MR data. The frequency and severity of metal artifacts in oncology patients was studied by inspecting the CT scans of 152 patients examined at our hospital. A prospective correction algorithm using CT and MR information to automatically locate and edit the region affected by metal artifacts was developed and tested retrospectively on data from 15 oncology patients referred for a PET/CT scan. In datasets without malignancies, the activity in Waldeyer's ring was used to measure the maximum uptake variation when the proposed correction was applied. The measured bias ranged from 10% to 30%. In datasets with malignancies on the slices affected by artifacts, the correction led to lesion uptake variations of 6.1% for a lesion 3 cm away from the implant, 1.5% for a lesion 7 cm away and <1% for a lesion 8 cm away.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Metais , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Implantes Dentários , Humanos , Neoplasias/diagnóstico por imagem , Estudos Retrospectivos
5.
Phys Med Biol ; 56(7): 2145-60, 2011 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-21389354

RESUMO

The evaluation of coronary plaque vulnerability could be of great diagnostic value in cardiology. Positron emission tomography (PET) is a good candidate due to its ability to quantify micromolar concentrations of targeted drugs. However, the detectability of sub-voxel targets such as coronary plaque is limited by partial volume effects and by cardiorespiratory motion. The goal of this paper is to investigate the impact of these factors in the detectability of plaque uptake. Radioactive markers were implanted on the epicardium of a pig and in vivo scans were performed. This was complemented with phantom measurements to determine the minimum detectable uptake as a function of background activity. Simulations were used to evaluate the effect of cardiorespiratory motion on the reconstructed lesions. Despite cardiorespiratory motion of up to 7 mm, the markers were detectable in the in vivo scans even after the injection of background. A lower limit of 250 Bq was found for a target to be detectable. Motion reduced the contrast of the reconstructed lesions to 23% of their static counterpart. Respiratory gating improved this to 49% of the static value. The results suggest that coronary plaque evaluation with PET is possible, provided that sufficient plaque-to-myocardium uptake contrast (50 to 100) can be achieved. This requirement increases exponentially for lesions with uptake below 250 Bq. The described experiments provide a means of estimating the minimum uptake and contrast required to ensure the detectability of plaque lesions.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Animais , Feminino , Guias como Assunto , Imagens de Fantasmas , Suínos
6.
Phys Med Biol ; 55(15): 4361-74, 2010 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-20647598

RESUMO

The combination of magnetic resonance imaging (MR) and positron emission tomography (PET) scanners can provide a powerful tool for clinical diagnosis and investigation. Among the challenges of developing a combined scanner, obtaining attenuation maps for PET reconstruction is of critical importance. This requires accounting for the presence of MR hardware in the field of view. The attenuation introduced by this hardware cannot be obtained from MR data. We propose the creation of attenuation models of MR hardware, to be registered into the MR-based attenuation map prior to PET reconstruction. Two steps were followed to assess the viability of this method. First, transmission and emission measurements were performed on MR components (RF coils and medical probes). The severity of the artifacts in the reconstructed PET images was evaluated. Secondly, a high-exposure computed tomography (CT) scan was used to obtain a model of a head coil. This model was registered into the attenuation map of PET/CT scans of a uniform phantom fitted with the coil. The resulting PET images were compared to the PET/CT reconstruction in the absence of coils. The artifacts introduced by misregistration of the model were studied. The transmission scans revealed 17% count loss due to the presence of head and neck coils in the field of view. Important sources of attenuation were found in the lock, signal cables and connectors. However, the worst source of attenuation was the casing between both coils. None of the measured medical probes introduced a significant amount of attenuation. Concerning the attenuation model of the head coil, reconstructed PET images with model-based correction were comparable to the reference PET/CT reconstruction. However, inaccuracies greater than 1-2 mm in the axial positioning of the model led to important artifacts. In conclusion, the results show that model-based attenuation correction is possible. Using a high-exposure scan to create an attenuation model of the coils has been proved feasible. However, adequate registration of the model is mandatory.


Assuntos
Artefatos , Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Imagem Corporal Total/instrumentação , Cabeça , Humanos , Modelos Teóricos , Pescoço , Imagens de Fantasmas , Fótons