1.
Artigo em Inglês | MEDLINE | ID: mdl-39001730

RESUMO

BACKGROUND: Global longitudinal strain (GLS) is reported to be more reproducible and prognostic than ejection fraction. Automated, transparent methods may increase trust and uptake. OBJECTIVES: The authors developed open machine-learning-based GLS methodology and validate it using multiexpert consensus from the Unity UK Echocardiography AI Collaborative. METHODS: We trained a multi-image neural network (Unity-GLS) to identify annulus, apex, and endocardial curve on 6,819 apical 4-, 2-, and 3-chamber images. The external validation dataset comprised those 3 views from 100 echocardiograms. End-systolic and -diastolic frames were each labelled by 11 experts to form consensus tracings and points. They also ordered the echocardiograms by visual grading of longitudinal function. One expert calculated global strain using 2 proprietary packages. RESULTS: The median GLS, averaged across the 11 individual experts, was -16.1 (IQR: -19.3 to -12.5). Using each case's expert consensus measurement as the reference standard, individual expert measurements had a median absolute error of 2.00 GLS units. In comparison, the errors of the machine methods were: Unity-GLS 1.3, proprietary A 2.5, proprietary B 2.2. The correlations with the expert consensus values were for individual experts 0.85, Unity-GLS 0.91, proprietary A 0.73, proprietary B 0.79. Using the multiexpert visual ranking as the reference, individual expert strain measurements found a median rank correlation of 0.72, Unity-GLS 0.77, proprietary A 0.70, and proprietary B 0.74. CONCLUSIONS: Our open-source approach to calculating GLS agrees with experts' consensus as strongly as the individual expert measurements and proprietary machine solutions. The training data, code, and trained networks are freely available online.

2.
Comput Biol Med ; 171: 108192, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38417384

RESUMO

Doppler echocardiography is a widely utilised non-invasive imaging modality for assessing the functionality of heart valves, including the mitral valve. Manual assessments of Doppler traces by clinicians introduce variability, prompting the need for automated solutions. This study introduces an innovative deep learning model for automated detection of peak velocity measurements from mitral inflow Doppler images, independent from Electrocardiogram information. A dataset of Doppler images annotated by multiple expert cardiologists was established, serving as a robust benchmark. The model leverages heatmap regression networks, achieving 96% detection accuracy. The model discrepancy with the expert consensus falls comfortably within the range of inter- and intra-observer variability in measuring Doppler peak velocities. The dataset and models are open-source, fostering further research and clinical application.


Assuntos
Aprendizado Profundo , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler/métodos , Valva Mitral/diagnóstico por imagem , Ultrassonografia Doppler
3.
Circ Cardiovasc Imaging ; 14(5): e011951, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33998247

RESUMO

BACKGROUND: requires training and validation to standards expected of humans. We developed an online platform and established the Unity Collaborative to build a dataset of expertise from 17 hospitals for training, validation, and standardization of such techniques. METHODS: The training dataset consisted of 2056 individual frames drawn at random from 1265 parasternal long-axis video-loops of patients undergoing clinical echocardiography in 2015 to 2016. Nine experts labeled these images using our online platform. From this, we trained a convolutional neural network to identify keypoints. Subsequently, 13 experts labeled a validation dataset of the end-systolic and end-diastolic frame from 100 new video-loops, twice each. The 26-opinion consensus was used as the reference standard. The primary outcome was precision SD, the SD of the differences between AI measurement and expert consensus. RESULTS: In the validation dataset, the AI's precision SD for left ventricular internal dimension was 3.5 mm. For context, precision SD of individual expert measurements against the expert consensus was 4.4 mm. Intraclass correlation coefficient between AI and expert consensus was 0.926 (95% CI, 0.904-0.944), compared with 0.817 (0.778-0.954) between individual experts and expert consensus. For interventricular septum thickness, precision SD was 1.8 mm for AI (intraclass correlation coefficient, 0.809; 0.729-0.967), versus 2.0 mm for individuals (intraclass correlation coefficient, 0.641; 0.568-0.716). For posterior wall thickness, precision SD was 1.4 mm for AI (intraclass correlation coefficient, 0.535 [95% CI, 0.379-0.661]), versus 2.2 mm for individuals (0.366 [0.288-0.462]). We present all images and annotations. This highlights challenging cases, including poor image quality and tapered ventricles. CONCLUSIONS: Experts at multiple institutions successfully cooperated to build a collaborative AI. This performed as well as individual experts. Future echocardiographic AI research should use a consensus of experts as a reference. Our collaborative welcomes new partners who share our commitment to publish all methods, code, annotations, and results openly.


Assuntos
Inteligência Artificial , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Aprendizado de Máquina , Humanos , Reprodutibilidade dos Testes , Reino Unido
SELEÇÃO DE REFERÊNCIAS