1.
J Biomech Eng ; 142(9)2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32154843

RESUMO

Impact biomechanics research in occupant safety predominantly focuses on the effects of loads applied to human subjects during automotive collisions. Characterization of the biomechanical response under such loading conditions is an active and important area of investigation. However, critical knowledge gaps remain in our understanding of human biomechanical response and injury tolerance under vertically accelerated loading conditions experienced due to underbody blast (UBB) events. This knowledge gap is reflected in anthropomorphic test devices (ATDs) used to assess occupant safety. Experiments are needed to characterize biomechanical response under UBB relevant loading conditions. Matched pair experiments in which an existing ATD is evaluated in the same conditions as a post mortem human subject (PMHS) may be utilized to evaluate biofidelity and injury prediction capabilities, as well as ATD durability, under vertical loading. To characterize whole body response in the vertical direction, six whole body PMHS tests were completed under two vertical loading conditions. A series of 50th percentile hybrid III ATD tests were completed under the same conditions. Ability of the hybrid III to represent the PMHS response was evaluated using a standard evaluation metric. Tibial accelerations were comparable in both response shape and magnitude, while other sensor locations had large variations in response. Posttest inspection of the hybrid III revealed damage to the pelvis foam and skin, which resulted in large variations in pelvis response. This work provides an initial characterization of the response of the seated hybrid III ATD and PMHS under high rate vertical accelerative loading.


Assuntos
Explosões , Aceleração , Acidentes de Trânsito , Fenômenos Biomecânicos , Traumatismos por Explosões
2.
Biomed Sci Instrum ; 51: 151-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25996712

RESUMO

Underbody blast (UBB) events transmit high-rate vertical loads through the seated occupant’s lumbar spine and have a high probability of inducing severe injury. While previous studies have characterized the lumbar spine under quasi-static loading, additional work should focus on the complex kinetic and kinematic response under high loading rates. To discern the biomechanical influence of the lumbar spine’s anatomical structures during dynamic loading, the axial force, flexion-extension moments and range of motion for lumbar motion segments (n=18) were measured during different states of progressive dissection. Pre-compression was applied using a static mass while dynamic bending was applied using an offset drop mass. Dynamic loading resulted in peak axial loads of 4,224±133 N, while maximum peak extension and flexion moments were 19.6±12.5 and -44.8±8.6 Nm in the pre-dissected state, respectively. Upon dissection, transection of the interspinous ligament, ligamentum flavum and facet capsules resulted in significantly larger flexion angles, while the removal of the posterior elements increased the total peak angular displacement in extension from 3.3±1.5 to 5.0±1.7 degrees (p=0.002). This study provides insight on the contribution of individual anatomical components on overall lumbar response under high-rate loading, as well as validation data for numerical models.

3.
Biomed Sci Instrum ; 51: 206-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25996719

RESUMO

Underbody blast (UBB) events impart vertical loads through a victim’s lumbar spine, resulting in fracture, paralysis, and disc rupture. Validated biofidelic lumbar models allow characterization of injury mechanisms and development of personal protective equipment. Previous studies have focused on lumbar mechanics under quasi-static loading. However, it is unclear how the role and response of individual spinal components of the lumbar spine change under dynamic loading. The present study leverages high-rate impacts of progressively dissected two-vertebra lumbar motion segments and Split-Hopkinson pressure bar tissue characterization to identify and validate material properties of a high-fidelity lumbar spine finite element model for UBB. The annulus fibrosus was modeled as a fiber-reinforced Mooney-Rivlin material, while ligaments were represented by nonlinear spring elements. Optimization and evaluation of material parameters was achieved by minimizing the root-mean-square (RMS) of compressive displacement and sagittal rotation for selected experimental conditions. Applying dynamic based material models and parameters resulted in a 0.42% difference between predicted and experiment axial compression during impact loading. This dynamically optimized lumbar model is suited for cross validation against whole-lumbar loading scenarios, and prediction of injury during UBB and other dynamic events.

4.
Med Eng Phys ; 27(4): 343-6, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15823476

RESUMO

In surgery of the cervical spine, a Caspar pin distractor is often used to apply a tensile load to the spine in order to open up the disc space. This is often done in order to place a graft or other interbody fusion device in the spine. Ideally a tight interference fit is achieved. If the spine is over distracted, allowing for a large graft, there is an increased risk of subsidence into the endplate. If there is too little distraction, there is an increased risk of graft dislodgement or pseudoarthrosis. Generally, graft height is selected from preoperative measurements and observed distraction without knowing the intraoperative compressive load. This device was designed to give the surgeon an assessment of this applied load. Instrumentation of the device involved the application of strain gauges and the selection of materials that would survive standard autoclave sterilization. The device was calibrated, sterilized and once again calibrated to demonstrate its suitability for surgical use. Results demonstrate excellent linearity in the calibration, and no difference was detected in the pre- and post-sterilization calibrations.


Assuntos
Vértebras Cervicais/cirurgia , Laminectomia/instrumentação , Dispositivos de Fixação Ortopédica , Esterilização , Instrumentos Cirúrgicos , Transdutores , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Laminectomia/métodos , Estresse Mecânico
5.
J Biomech ; 38(5): 1011-21, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15797583

RESUMO

This study was performed to characterize the mechanical properties of the kidney capsular membrane at strain-rates associated with blunt abdominal trauma. Uniaxial quasi-static and dynamic tensile experiments were performed on fresh, unfrozen porcine and human renal capsules at deformation rates ranging from 0.0001 to 7 m/s (strain-rates of 0.005-250 s(-1)). Single stroke, dynamic tests were performed on samples of porcine renal capsule at strain-rates of 0.005 s(-1) (n = 33), 0.05 s(-1) (n = 17), 0.5 s(-1) (n = 38), 2 s(-1) (n = 10), 4 s(-1) (n = 10), 50 s(-1) (n = 21), 100 s(-1) (n = 18), 150 s(-1) (n = 17), 200 s(-1) (n = 10), and 250 s(-1) (n = 17). Due to limited availability of human tissues, only quasi-static tests were performed (0.005 s(-1), n = 25). Porcine renal capsule properties were found to match the material properties of human capsular tissue sufficiently well such that porcine tissue material can be used as a human test surrogate. The apparent elastic modulus and breaking stress of the porcine renal capsule were observed to increase significantly with increasing strain-rate (p < 0.01). Breaking strain was inversely related to strain-rate (p < 0.01). The effect of increasing strain-rate on material properties diminished appreciably at rates exceeding 150 s(-1). Empirically derived mathematical models of constitutive behavior were developed using a hyperelastic/viscoelastic Ogden formulation, as well as a Cowper-Symonds law material curve multiplication.


Assuntos
Rim/fisiologia , Modelos Biológicos , Animais , Simulação por Computador , Elasticidade , Humanos , Técnicas In Vitro , Membranas/fisiologia , Especificidade da Espécie , Estresse Mecânico , Suínos , Resistência à Tração/fisiologia , Viscosidade
6.
J Biomech Eng ; 118(4): 575-8, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8950662

RESUMO

In an attempt to test the hypothesis of spontaneous hip fracture, seven pairs of femurs, with ages ranging from 59 to 90, were tested under two loading conditions designed to simulate muscular contraction. Simulated iliopsoas contraction produced femoral neck fractures at an average normalized ultimate load of 5.2 +/- 0.8 times body weight. Simulated gluteus medius contraction produced sub-/inter-trochanteric fractures at an average normalized ultimate load of 4.1 +/- 0.6 times body weight. The average ultimate load for all specimens was 3040 +/- 720 N. Fracture patterns produced by both loading conditions were clinically relevant. The results from this study suggest that abnormal contraction produced by major rotator muscles could induce hip fracture.


Assuntos
Fraturas do Fêmur/fisiopatologia , Fraturas do Quadril/fisiopatologia , Suporte de Carga/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Modelos Biológicos , Contração Muscular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA