Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
J Extracell Vesicles ; 13(7): e12457, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007430

RESUMO

Seminal plasma induces immune tolerance towards paternal allogenic antigens within the female reproductive tract and during foetal development. Recent evidence suggests a role for extracellular vesicles in seminal plasma (spEVs). We isolated spEVs from seminal plasma that was donated by vasectomized men, thereby excluding any contributions from the testis or epididymis. Previous analysis demonstrated that such isolated spEVs originate mainly from the prostate. Here we observed that when isolated fluorescently labelled spEVs were mixed with peripheral blood mononuclear cells, they were endocytosed predominantly by monocytes, and to a lesser extent also by T-cells. In a mixed lymphocyte reaction, T-cell proliferation was inhibited by spEVs. A direct effect of spEVs on T-cells was demonstrated when isolated T cells were activated by anti-CD3/CD28 coated beads. Again, spEVs interfered with T cell proliferation, as well as with the expression of CD25 and the release of IFN-γ, TNF, and IL-2. Moreover, spEVs stimulated the expression of Foxp3 and IL-10 by CD4+CD25+CD127- T cells, indicating differentiation into regulatory T-cells (Tregs). Prior treatment of spEVs with proteinase K revoked their effects on T-cells, indicating a requirement for surface-exposed spEV proteins. The adenosine A2A receptor-specific antagonist CPI-444 also reduced effects of spEVs on T-cells, consistent with the notion that the development of Tregs and their immune suppressive functions are under the influence of adenosine-A2A receptor signalling. We found that adenosine is highly enriched in spEVs and propose that spEVs are targeted to and endocytosed by T-cells, after which they may release their adenosine content into the lumen of endosomes, thus allowing endosome-localized A2A receptor signalling in spEVs targeted T-cells. Collectively, these data support the idea that spEVs can prime T cells directly for differentiation into Tregs.


Assuntos
Diferenciação Celular , Vesículas Extracelulares , Sêmen , Linfócitos T Reguladores , Humanos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/imunologia , Linfócitos T Reguladores/imunologia , Linfócitos T Reguladores/metabolismo , Sêmen/metabolismo , Sêmen/imunologia , Masculino , Proliferação de Células , Ativação Linfocitária/imunologia
2.
Clin Chem Lab Med ; 62(7): 1352-1361, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38205847

RESUMO

OBJECTIVES: Correct interpretation of thyroid function tests relies on correct reference intervals (RIs) for thyroid-stimulating hormone (TSH) and free thyroxine (FT4). ISO15189 mandates periodic verification of RIs, but laboratories struggle with cost-effective approaches. We investigated whether indirect methods (utilizing historical laboratory data) could replace the direct approach (utilizing healthy reference individuals) and compared results with manufacturer-provided RIs for TSH and FT4. METHODS: We collected historical data (2008-2022) from 13 Dutch laboratories to re-establish RIs by employing indirect methods, TMC (for TSH) and refineR (for FT4). Laboratories used common automated platforms (Roche, Abbott, Beckman or Siemens). Indirect RIs (IRIs) were determined per laboratory per year and clustered per manufacturer (>1.000.000 data points per manufacturer). Direct RIs (DRIs) were established in 125 healthy individuals per platform. RESULTS: TSH IRIs remained robust over the years for all manufacturers. FT4 IRIs proved robust for three manufacturers (Roche, Beckman and Siemens), but the IRI upper reference limit (URL) of Abbott showed a decrease of 2 pmol/L from 2015. Comparison of the IRIs and DRIs for TSH and FT4 showed close agreement using adequate age-stratification. Manufacturer-provided RIs, notably Abbott, Roche and Beckman exhibited inappropriate URLs (overall difference of 0.5-1.0 µIU/mL) for TSH. For FT4, the URLs provided by Roche, Abbott and Siemens were overestimated by 1.5-3.5 pmol/L. CONCLUSIONS: These results underscore the importance of RI verification as manufacturer-provided RIs are often incorrect and RIs may not be robust. Indirect methods offer cost-effective alternatives for laboratory-specific or platform-specific verification of RIs.


Assuntos
Tireotropina , Tiroxina , Humanos , Tiroxina/sangue , Tiroxina/análise , Tireotropina/sangue , Tireotropina/análise , Tireotropina/normas , Valores de Referência , Testes de Função Tireóidea/normas , Testes de Função Tireóidea/métodos , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Rotulagem de Produtos/normas
4.
Rev Assoc Med Bras (1992) ; 69(12): e20230716, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37971126

RESUMO

OBJECTIVE: The delayed increase in serum creatinine levels poses challenges in the timely diagnosis of acute kidney injury. This study aimed to investigate the relationship between serum angiotensinogen and urinary angiotensinogen levels and the prognosis of renal function in patients diagnosed with acute kidney injury. METHODS: A total of 79 newly diagnosed acute kidney injury patients aged 18 years and older were enrolled. Serum angiotensinogen and urinary angiotensinogen levels were measured at the onset of the disease, as well as on the 15th and 30th days of follow-up. After 3 months, renal function was evaluated by measuring serum creatinine levels. RESULTS: Among the acute kidney injury patients, those in Kidney Disease: Improving Global Outcomes stage 3 exhibited significantly higher urinary angiotensinogen/urine creatinine levels compared with stages 1 and 2 patients at the time of diagnosis (p<0.05). Furthermore, a positive correlation was observed between the urinary angiotensinogen/urine creatinine level at the time of diagnosis and the serum creatinine level at the third month (r=0.408, p=0.048). CONCLUSION: The findings suggest that urinary angiotensinogen levels can serve as an indicator of the severity of acute kidney injury. Monitoring urinary angiotensinogen levels could potentially contribute to the prognosis assessment and management of acute kidney injury patients.


Assuntos
Injúria Renal Aguda , Angiotensinogênio , Humanos , Prognóstico , Angiotensinogênio/urina , Estudos Prospectivos , Creatinina , Biomarcadores , Injúria Renal Aguda/diagnóstico , Rim
5.
Adv Skin Wound Care ; 36(11): 1-9, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37861670

RESUMO

OBJECTIVE: To understand the problems experienced by healthcare workers (HCWs) who used personal protective equipment (PPE) on their face during the COVID-19 pandemic, their interventions to prevent these problems, and their recommendations for improving the quality of PPE. METHODS: This descriptive and qualitative study included HCWs (N = 29) from health institutions at different levels in Turkey. Researchers collected data using a semistructured data collection form (13 items) and in-depth individual interviews. Data were analyzed with descriptive statistics and qualitative inductive content analysis. RESULTS: Of the 29 participants, 15 (51.7%) were women, and 18 (62.1%) were nurses. Participants' answers regarding problems related to PPE use were grouped into four main categories, answers regarding the prevention of these problems were grouped into three main categories, and answers regarding improving the quality of PPE were grouped into three main categories. Skin concerns were the most commonly reported problems related to PPE, and interventions to prevent these problems primarily related to skin protection and care. Recommendations to improve the quality of PPE focused on using materials for masks and face shields that reduce pressure and friction; participants also suggested that face shields be produced in sterile and disposable packages. CONCLUSIONS: This research indicates that HCWs need support and they are able to create individual solutions for the problems with PPE that they experience. Skin-friendly PPE that ensures the safety and comfort of HCWs should be produced, and hospitals should develop policies for institutional use to prevent PPE injury.


Assuntos
COVID-19 , Pandemias , Feminino , Humanos , Masculino , Pandemias/prevenção & controle , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Equipamento de Proteção Individual/efeitos adversos , Pessoal de Saúde , COVID-19/prevenção & controle
6.
J Pediatr Nurs ; 73: e364-e371, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37806856

RESUMO

BACKGROUND: Burn dressing, a necessary and regular procedure for burn management, causes significant pain and distress for children. Recent technological advancements in VR have opened up new possibilities for pain management in children undergoing burn dressing. However, there is limited evidence regarding their efficacy in burn dressing specifically. This study aims to synthesize and analyze the effect of VR on pain during burn dressing in children. METHODS: In this review, we investigated studies from PubMed, Web of Science, Cochrane, MEDLINE, CINAHL, Scopus and Google Scholar databases that met inclusion criteria. We also assessed the studies' methodological quality with the Cochrane and JBI checklists. This study was performed based on the Guidelines of Systematic Reporting of Examination presented in the PRISMA checklist. The search protocol has been registered at the PROSPERO International Prospective Register of Systematic Reviews. RESULTS: A total of six published studies including 241 pediatric patients were included in this review. The meta-analysis results showed a significant effect of VR intervention on the pain levels of children (Hedge's g = -1199, Q = 31,106, I2 = 83,926%, p < 0.001). CONCLUSION: Findings from this study show that VR is a promising and effective intervention for reducing pain scores in children undergoing dressing changes for burn injuries. IMPLACATION TO PRACTICE: Our meta-analysis suggest that the significant potential of integrating VR into clinical practice, presenting a non-pharmacological intervention to reduce pain during dressing changes in pediatric burn patients. Implementing VR in healthcare settings can lead to improved pain management and better patient outcomes for pediatric population.


Assuntos
Queimaduras , Realidade Virtual , Criança , Humanos , Bandagens/efeitos adversos , Queimaduras/complicações , Queimaduras/terapia , Dor/etiologia , Dor/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Brain Commun ; 5(5): fcad223, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37731906

RESUMO

Nodding syndrome is a neglected, disabling and potentially fatal epileptic disorder of unknown aetiology affecting thousands of individuals mostly confined to Eastern sub-Saharan Africa. Previous studies have identified multiple associations-including Onchocerca volvulus, antileiomodin-1 antibodies, vitamin B6 deficiency and measles virus infection-yet, none is proven causal. We conducted a case-control study of children with early-stage nodding syndrome (symptom onset <1 year). Cases and controls were identified through a household survey in the Greater Mundri area in South Sudan. A wide range of parasitic, bacterial, viral, immune-mediated, metabolic and nutritional risk factors was investigated using conventional and state-of-the-art untargeted assays. Associations were examined by multiple logistic regression analysis, and a hypothetical causal model was constructed using structural equation modelling. Of 607 children with nodding syndrome, 72 with early-stage disease were included as cases and matched to 65 household- and 44 community controls. Mansonella perstans infection (odds ratio 7.04, 95% confidence interval 2.28-21.7), Necator americanus infection (odds ratio 2.33, 95% confidence interval 1.02-5.3), higher antimalarial seroreactivity (odds ratio 1.75, 95% confidence interval 1.20-2.57), higher vitamin E concentration (odds ratio 1.53 per standard deviation increase, 95% confidence interval 1.07-2.19) and lower vitamin B12 concentration (odds ratio 0.56 per standard deviation increase, 95% confidence interval 0.36-0.87) were associated with higher odds of nodding syndrome. In a structural equation model, we hypothesized that Mansonella perstans infection, higher vitamin E concentration and fewer viral exposures increased the risk of nodding syndrome while lower vitamin B12 concentration, Necator americanus and malaria infections resulted from having nodding syndrome. We found no evidence that Onchocerca volvulus, antileiomodin-1 antibodies, vitamin B6 and other factors were associated with nodding syndrome. Our results argue against several previous causal hypotheses including Onchocerca volvulus. Instead, nodding syndrome may be caused by a complex interplay between multiple pathogens and nutrient levels. Further studies need to confirm these associations and determine the direction of effect.

8.
Mol Biol Rep ; 50(10): 8551-8563, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37644370

RESUMO

BACKGROUND: Liver cancer is the third leading cause of cancer-related deaths worldwide, and hepatocellular carcinoma (HCC) is the most common type of liver cancer. Transarterial interventions are among the chemotherapeutic approaches used in hardly operable regions prior to transplantation, and in electrochemotherapy, where doxorubicin is used. However, the efficacy of treatment is affected by resistance mechanisms. Previously, we showed that overexpression of the CUE5 gene results in doxorubicin resistance in Saccharomyces cerevisiae (S. cerevisiae). In this study, the effect of Toll-interacting protein (TOLLIP), the human ortholog of CUE5, on doxorubicin resistance was evaluated in HCC cells to identify its possible role in increasing the efficacy of transarterial interventions. METHODS AND RESULTS: The NIH Gene Expression Omnibus (GEO) and Oncomine datasets were analyzed for HCC cell lines with relatively low and high TOLLIP expression, and SNU449 and Hep3B cell lines were chosen, respectively. TOLLIP expression was increased by plasmid transfection and decreased by TOLLIP-siRNA in both cell lines and evaluated by RT-PCR and ELISA. Cell proliferation and viability were examined using xCELLigence and MTT assays after doxorubicin treatment, and growth inhibitory 50 (GI 50) concentrations were evaluated. Doxorubicin GI 50 concentrations decreased approximately 2-folds in both cell lines upon silencing TOLLIP after 48 h of drug treatment. CONCLUSIONS: Our results showed for the first time that silencing TOLLIP in hepatocellular carcinoma cells may help sensitize these cells to doxorubicin and increase the efficacy of chemotherapeutic regimens where doxorubicin is used.


Assuntos
Carcinoma Hepatocelular , Peptídeos e Proteínas de Sinalização Intracelular , Neoplasias Hepáticas , Humanos , Apoptose , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/genética , Carcinoma Hepatocelular/metabolismo , Linhagem Celular Tumoral , Doxorrubicina/farmacologia , Doxorrubicina/uso terapêutico , Resistencia a Medicamentos Antineoplásicos/genética , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/metabolismo , Saccharomyces cerevisiae , Peptídeos e Proteínas de Sinalização Intracelular/genética
9.
Clin Chem Lab Med ; 61(12): 2167-2177, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37401696

RESUMO

OBJECTIVES: Measurement of plasma albumin is pivotal for clinical decision-making in patients with chronic kidney disease (CKD). Routinely used methods as bromocresol green (BCG) and bromocresol purple (BCP) can suffer from aselectivity, but the impact of aselectivity on the accuracy of plasma albumin results of CKD-patients is still unknown. Therefore, we evaluated the performance of BCG-, BCP- and JCTLM-endorsed immunological methods in patients with various stages of CKD. METHODS: We evaluated the performance of commonly used albumin methods in patients with CKD stages G1 through G5, the latter divided in two groups based on whether they received hemodialysis treatment. In total, 163 patient plasma samples were measured at 14 laboratories, on six different BCG and BCP-platforms, and four different immunological platforms. The results were compared with an ERM-DA-470k-corrected nephelometric assay. The implications on outcome is evaluated by the proportion of patient results <38 g/L for the diagnosis of protein energy wasting. RESULTS: Albumin results determined with BCP- and immunological methods showed the best agreement with the target value (92.7 and 86.2 %, respectively vs. 66.7 % for BCG, namely due to overestimation). The relative agreement of each method with the target value was platform-dependent, with larger variability in agreement between platforms noted for BCG and immunological methods (3.2-4.6 and 2.6-5.3 %) as opposed to BCP (0.7-1.5 %). The stage of CKD had similar effects on the variability in agreement for the three method-groups (0.6-1.8 % vs. 0.7-1.5 % vs. 0.4-1.6 %). The differences between methods cause discrepancies in clinical decision-making, as structurally fewer patients were diagnosed with protein energy wasting upon using BCG-based albumin results. CONCLUSIONS: Our study shows that BCP is fit for the intended use to measure plasma albumin levels in CKD patients from all stages, including patients on hemodialysis. In contrast, most BCG-based platforms falsely overestimate the plasma albumin concentration.


Assuntos
Verde de Bromocresol , Insuficiência Renal Crônica , Humanos , Albumina Sérica/análise , Púrpura de Bromocresol , Diálise Renal , Insuficiência Renal Crônica/diagnóstico
10.
J Pediatr Nurs ; 72: e130-e138, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37344345

RESUMO

PROBLEM: To determine the pooled incidence and prevalence rate of medical device-related pressure injuries(MDRPIs) using the Braden QD scale, medical devices that frequently cause MDRPIs, and anatomical locations that are vulnerable to them. ELIGIBILITY CRITERIA: Using the Braden QD scale, being published in English between 01/01/2018-and 01/03/2023. METHODS: This study was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis recommendations and registered in the International Prospective Register of Systematic Reviews database (No: CRD42021276501). SAMPLE: A total of 7 studies with 25,742 pediatric patients were included. RESULTS: The pooled prevalence and cumulative incidence of hospital-acquired pressure injuries(HAPIs) were 7.8% (95% CI: 5.2-11.4%) and 3.9% (95% CI: 0.5-24.6%) respectively, and the incidence rate was 8.2/1000 person-days (95% CI: 2.4-14.2/1000 person-days). The pooled prevalence and cumulative incidence of MDRPIs were 7% (95% CI: 5.5-8.8%) and 5% (95% CI: 3.2-7.8%) respectively, and the incidence rate was 6.7/1000 person-days (95% CI, 0.11-13.4/1000 person-days). The most affected anatomical locations were the face (29.1%), ankle/foot (20.1%), and head (15.7%). Medical devices that frequently caused MDRPIs were external monitoring devices (24.5%), respiratory devices (22.8%), and supportive/securing devices (14.9%). CONCLUSIONS: According to the current systematic review and meta-analyses, the incidence and prevalence of HAPIs and MDRPIs are moderate to high. IMPLICATIONS: The findings suggested that healthcare providers should pay more attention to reducing HAPIs and MDRPIs and future studies should be conducted to understand their characteristics and risk factors.


Assuntos
Úlcera por Pressão , Criança , Humanos , Úlcera por Pressão/epidemiologia , Úlcera por Pressão/etiologia , Incidência , Prevalência , Fatores de Risco , Bases de Dados Factuais
11.
Eur J Dev Res ; : 1-22, 2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37361475

RESUMO

We examine the association between the Covid-19 pandemic and and access to basic needs, and how households respond using various coping strategies in the context of Nigeria. We use data from the Covid-19 National Longitudinal Phone Surveys (Covid-19 NLPS-2020) conducted during the Covid-19 lockdown. Our findings reveal that the Covid-19 pandemic is associated with households' exposure to shocks such as illness or injury, disruption of farming, job losses, non-farm business closure, and increase in price of food items and farming inputs. These negative shocks have severe consequences on access to basic needs of households, and the outcomes are heterogeneous across gender of household head and rural-urban residence. Households adopt a number of coping strategies, both formal and informal to mitigate the effects of the shocks on access to basic needs. The findings of this paper lend credence to the growing evidence on need to support households exposed to negative shocks and the role of formal coping mechanisms for households in developing countries.


Nous examinons le lien entre les chocs provoqués par la Covid-19 et l'accès aux services répondant aux besoins fondamentaux, et la façon dont les ménages ont réagi en utilisant diverses stratégies d'adaptation au Nigeria. Nous utilisons les données d'enquêtes téléphoniques longitudinales nationales Covid-19 (Covid-19 NLPS-2020) menées pendant le confinement lié à la Covid-19. Nos résultats révèlent que la pandémie de Covid-19 est associée à l'exposition des ménages à des chocs tels que la maladie ou les blessures, la perturbation de l'agriculture, les pertes d'emplois, la fermeture d'entreprises non agricoles et l'augmentation des prix des denrées alimentaires et des intrants agricoles. Ces chocs négatifs affectent gravement l'accès aux besoins fondamentaux des ménages, et les résultats sont hétérogènes selon le sexe des chefs de famille et selon le lieu de résidence rural ou urbain des ménages. Les ménages adoptent diverses stratégies d'adaptation formelles et informelles pour atténuer les effets des chocs sur l'accès aux besoins fondamentaux. Les conclusions de ce document donnent du crédit aux preuves de plus en plus nombreuses de la nécessité de soutenir les ménages exposés aux chocs négatifs et du rôle des mécanismes d'adaptation formels pour les ménages dans les pays en développement.

12.
Lancet ; 401(10388): 1595-1609, 2023 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-37088092

RESUMO

BACKGROUND: Anaemia affects 46% of pregnancies in Africa; oral iron is recommended by WHO but uptake and adherence are suboptimal. We tested a single dose of a modern intravenous iron formulation, ferric carboxymaltose, for anaemia treatment in Malawian pregnant women. METHODS: In this open-label, individually randomised controlled trial, we enrolled women with a singleton pregnancy of 13-26 weeks' gestation in primary care and outpatient settings across two regions in southern Malawi. Women were eligible if they had capillary haemoglobin of less than 10·0 g/dL and negative malaria rapid diagnostic test. Participants were randomised by sealed envelope 1:1. Assessors for efficacy outcomes (laboratory parameters and birthweight) were masked to intervention; participants and study nurses were not masked. Participants were given ferric carboxymaltose up to 1000 mg (given once at enrolment in an outpatient primary care setting), or standard of care (60 mg elemental iron twice daily for 90 days), along with intermittent preventive malaria treatment. The primary maternal outcome was anaemia at 36 weeks' gestation. The primary neonatal outcome was birthweight. Analyses were performed in the intention-to-treat population for mothers and liveborn neonates, according to their randomisation group. Safety outcomes included incidence of adverse events during infusion and all adverse events from randomisation to 4 weeks' post partum. The trial is registered with ANZCTR, ACTRN12618001268235. The trial has completed follow-up. FINDINGS: Between Nov 12, 2018, and March 2, 2021, 21 258 women were screened, and 862 randomly assigned to ferric carboxymaltose (n=430) or standard of care (n=432). Ferric carboxymaltose did not reduce anaemia prevalence at 36 weeks' gestation compared with standard of care (179 [52%] of 341 in the ferric carboxymaltose group vs 189 [57%] of 333 in the standard of care group; prevalence ratio [PR] 0·92, 95% CI 0·81 to 1·06; p=0·27). Anaemia prevalence was numerically lower in mothers randomly assigned to ferric carboxymaltose compared with standard of care at all timepoints, although significance was only observed at 4 weeks' post-treatment (PR 0·91 [0·85 to 0·97]). Birthweight did not differ between groups (mean difference -3·1 g [-75·0 to 68·9, p=0·93). There were no infusion-related serious adverse events or differences in adverse events by any organ class (including malaria; ≥1 adverse event: ferric carboxymaltose 183 [43%] of 430 vs standard of care 170 [39%] of 432; risk ratio 1·08 [0·92 to 1·27]; p=0·34). INTERPRETATION: In this malaria-endemic sub-Saharan African setting, treatment of anaemic pregnant women with ferric carboxymaltose was safe but did not reduce anaemia prevalence at 36 weeks' gestation or increase birthweight. FUNDING: Bill & Melinda Gates Foundation (INV-010612).


Assuntos
Anemia Ferropriva , Anemia , Malária , Recém-Nascido , Feminino , Humanos , Gravidez , Ferro/uso terapêutico , Gestantes , Segundo Trimestre da Gravidez , Peso ao Nascer , Anemia Ferropriva/tratamento farmacológico , Malária/tratamento farmacológico , Malária/prevenção & controle , Anemia/tratamento farmacológico , Malaui/epidemiologia
13.
Gates Open Res ; 7: 117, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38343768

RESUMO

Background: Anemia affects 40% of pregnant women globally, leading to maternal mortality, premature birth, low birth weight, and poor baby development. Iron deficiency causes over 40% of anemia cases in Africa. Oral iron supplementation is insufficient for Low-and-Middle-Income-Countries (LMICs) to meet current WHO targets. We hypothesized that a single intravenous dose of Ferric Carboxymaltose (FCM) may be more effective than oral iron treatment for anemia recovery, particularly in these settings where women present late for antenatal care. Methods: This is a two-arm parallel open-label individual-randomized controlled trial in third trimester, in malaria Rapid Diagnostic Test-negative pregnant women with moderate or severe anemia - capillary hemoglobin <10 g/dL - who are randomized to receive either parenteral iron - with FCM - or standard-of-care oral iron for the remainder of pregnancy. This is the sister trial to the second-trimester REVAMP trial, funded by the Bill and Melinda Gates Foundation (trial registration ACTRN12618001268235, Gates Grant number INV-010612). In REVAMP-TT, recruitment and treatment are performed within primary health centers. The trial will recruit 590 women across Zomba district, Malawi. The primary outcome is the proportion of anemic women - venous hemoglobin <11 g/dL - at 36 weeks' gestation or delivery (whichever occurs first). Other pre-specified key secondary clinical and safety outcomes include maternal iron-status and hypophosphatemia, neonate birth weight, infant growth and infant iron and hematological parameters. Discussion: This study will determine whether FCM, delivered within primary health centers, is effective, safe and feasible for treating moderate to severe anemia in third-trimester pregnant Malawian women. This intervention could have long-term benefits for maternal and child health, resulting in improved survival and child development.


Assuntos
Anemia Ferropriva , Anemia , Compostos Férricos , Maltose/análogos & derivados , Recém-Nascido , Criança , Feminino , Humanos , Gravidez , Ferro/uso terapêutico , Terceiro Trimestre da Gravidez , Gestantes , Anemia Ferropriva/tratamento farmacológico , Anemia/tratamento farmacológico , Hemoglobinas/análise , Malaui/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
J Pers Med ; 12(12)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36556285

RESUMO

Elevated levels of STIM1, an endoplasmic reticulum Ca2+ sensor/buffering protein, appear to be correlated with poor cancer prognosis in which microRNAs are also known to play critical roles. The purpose of this study is to investigate possible HBV origins of specific microRNAs we identified in a stem cell-like subpopulation of Huh-7 hepatocellular carcinoma (HCC) cell lines with enhanced STIM1 and/or Orai1 expression that mimicked poor cancer prognosis. Computational strategies including phylogenetic analyses were performed on miRNome data we obtained from an EpCAM- and CD133-expressing Huh-7 HCC stem cell-like subpopulation with enhanced STIM1 and/or Orai1 expression originally cultured in the present work. Results revealed two putative regions in the HBV genome based on the apparent clustering pattern of stem loop sequences of microRNAs, including miR3653. Reciprocal analysis of these regions identified critical human genes, of which their transcripts are among the predicted targets of miR3653, which was increased significantly by STIM1 or Orai1 enhancement. Briefly, this study provides phylogenetic evidence for a possible HBV-driven epigenetic remodeling that alters the expression pattern of Ca2+ homeostasis-associated genes in STIM1- or Orai1 overexpressing liver cancer stem-like cells for a possible mutual survival outcome. A novel region on HBV-X protein may affect liver carcinogenesis in a genotype-dependent manner. Therefore, detection of the viral genotype would have a clinical impact on prognosis of HBV-induced liver cancers.

15.
Clin Chem Lab Med ; 60(10): 1661-1668, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-35918785

RESUMO

OBJECTIVES: Testosterone testing is relevant for evaluating castration adequacy and diagnosis of castration-resistant prostate cancer (PCa). However, the recommended testosterone cut-off of 1.7 nmol/L (50 ng/dL) to define adequate castration is based on consensus and not validated for the automated immunoassays (AIA) used in today's medical laboratories. Furthermore, appropriate population intervals have not been determined by a state-of-the-art assay. We investigated the analytical suitability of this cut-off and the accuracy of the present-day AIAs for testosterone analysis in castrated PCa patients. METHODS: Leftover serum from 120 PCa patients castrated with luteinizing hormone-releasing hormone agonists was analysed for testosterone by five methods: Architect i2000 (Abbott), Access (Beckman), Cobas 6000 (Roche), Atellica (Siemens), LC-MS/MS. For all assays, the castration 95th, 97.5th and 99th percentile upper limits were determined. Furthermore, Passing-Bablok regression, mean bias and Spearman's correlation coefficients were compared to the LC-MS/MS method and total error based on biological variation. RESULTS: All castration upper limits, ranging from 0.472 nmol/L (LC-MS/MS) to 1.25 nmol/L (Access) (95% percentile), were significantly lower than the current castration cut-off (1.7 nmol/L). Slopes of Passing-Bablok regressions comparing the AIA with the LC-MS/MS method ranged from 1.4 (Cobas and Atellica) to 3.8 (Access). The Architect showed the highest correlation with LC-MS/MS (ρ=0.58). All AIA failed to meet the desirable total error criterion. CONCLUSIONS: These results suggest that a lower general testosterone castration cut-off may be more appropriate in evaluating the adequacy of castration in PCa and that present-day AIA lack analytical accuracy to quantify testosterone levels in castrated PCa.


Assuntos
Neoplasias da Próstata , Testosterona , Castração , Cromatografia Líquida , Humanos , Imunoensaio , Masculino , Espectrometria de Massas em Tandem
16.
BMJ Case Rep ; 15(7)2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35840164

RESUMO

A postmenopausal woman in her 60s was referred due to an elevated haemoglobin value found during her annual check-up. On physical examination, characteristic features of hyperandrogenism were observed which were not earlier mentioned. Laboratory investigations revealed polycythaemia accompanied by a normal erythropoietin and a negative analysis for JAK2-V617F mutation. A disproportionally and markedly elevated testosterone in combination with normal levels of adrenal androgens raised the suspicion of an ovarian source. CT scan showed nodular hyperdense lesions in both ovaries. A bilateral oophorectomy was performed and histological evaluation unfolded a Leydig cell ovarian tumour. Testosterone levels and haematological parameters normalised after surgery. Polycythaemia secondary to hyperandrogenism in postmenopausal women is an extremely rare condition and patients should be carefully analysed for the presence of androgen-secreting neoplasms. Diagnosis of the underlying pathology requires careful history, physical examination and comprehensive investigation. Treatment for this condition is surgery and resolves polycythaemia.


Assuntos
Hiperandrogenismo , Tumor de Células de Leydig , Neoplasias Ovarianas , Policitemia , Androgênios , Feminino , Humanos , Hiperandrogenismo/diagnóstico , Tumor de Células de Leydig/complicações , Tumor de Células de Leydig/diagnóstico , Tumor de Células de Leydig/cirurgia , Masculino , Neoplasias Ovarianas/complicações , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/cirurgia , Policitemia/complicações , Testosterona
17.
Scand J Clin Lab Invest ; 81(7): 585-592, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34686074

RESUMO

BACKGROUND: In 2017 the Atellica® UAS 800 urine sediment analyzer was introduced by Siemens Healthineers. We investigated its applicability in the standardization and automation of the laboratory urinalysis workflow, including the prediction of urine culture outcome and glomerular pathology. METHODS: We evaluated the performance characteristics of the Atellica® UAS 800 and its correlation with the iQ200 (Beckman Coulter). In addition, we studied the agreement between Atellica® UAS 800 and CLINITEK Novus® and determined the predictive value of bacteria and leukocyte counts for urine culture outcome. Furthermore, we investigated the ability of Atellica® UAS 800 to identify pathological casts and dysmorphic erythrocytes in comparison to manual microscopy. RESULTS: Erythrocyte and leukocyte analyses indicated high intra- and inter-run precisions and good correlations with the iQ200. We found that the Atellica® UAS 800 detects bacteria with higher sensitivity than the iQ200. The Atellica® UAS 800 and CLINITEK Novus® showed a high degree of conformity. We determined seven combinations of clinical cut-off values of bacteria and leukocytes for predicting urine culture outcome with sensitivity, specificity, and negative predictive values of 95%, 52%, and 93%, respectively. Using the Atellica® UAS 800, hyaline casts, erythrocyte casts, leukocyte casts, and dysmorphic erythrocytes were correctly recognized in 76%, 22%, 2%, and 39% of the samples, respectively. CONCLUSIONS: The Atellica® UAS 800 is a robust, fast, and user-friendly analyzer, which accurately quantifies erythrocytes, leukocytes, bacteria and squamous epithelial cells, and may be utilized for predicting positive urine cultures. The detection of clinically important pathological casts and dysmorphic erythrocytes proved insufficient.


Assuntos
Urinálise/instrumentação , Automação , Bactérias/metabolismo , Eritrócitos/citologia , Humanos , Leucócitos/citologia , Modelos Logísticos , Curva ROC , Sensibilidade e Especificidade
18.
Mikrobiyol Bul ; 55(3): 311-326, 2021 Jul.
Artigo em Turco | MEDLINE | ID: mdl-34416799

RESUMO

The SARS-CoV-2 virus, which caused the COVID-19 epidemic, caused more than 55 million cases and nearly 1.5 million deaths worldwide. For the microbiological diagnosis of the disease, the most valid method is detecting the presence of the viral genome by real-time reverse transcription polymerase chain reaction (rRT-PCR). However, due to the nature of the RNA viruses, frequent mutations may affect the sensitivity of the analyses made on the genetic material of the virus, such as PCR. In this study, we aimed to investigate the mutations in the primer-probe binding regions of the rRT-PCR panels used in COVID-19 diagnosis. SARS-CoV-2 whole genome sequence data (n= 194) isolated from COVID-19 cases in Turkey and uploaded on GISAID database from the centers in Istanbul (n= 78), Ankara (n= 58), Kars (n= 47), Bursa (n= 2), Adiyaman (n= 2), Erciyes (n= 1) and Kocaeli (n= 1) between March 17-September 14, 2020 were analyzed. In order to determine the nucleotide changes, SARS-CoV-2 sequences from Turkey were compared to the reference genome sequence (NC_045512.1) present in "GenBank" website. The constructed data set was aligned using the MAFFT program and was checked manually if the sequences were in the same frame by using the AliView program. Primer-probe binding sites of the thirteen SARS-CoV-2 rRT-PCR panels from seven different institutes (US CDC, China CDC, Charite CDC, Pasteur, HKU, Thailand, NIID) that are being used in COVID-19 diagnosis were evaluated in terms of nucleotide changes within the corresponding regions compared to the reference genome. Sequence diversities in the viral genomes were determined via positional nucleotide numerical calculator and entropy calculator modules and nucleotide and entropy changes in primer-probe binding regions for each rRT-PCR panel were examined. Among thirteen different primer-probe panels, nucleotide changes in the target regions of the seven primer-probe panels were determined. When viral sequences with nucleotide changes in the primer-probe binding regions were examined, the most common changes were observed in the "China CDC" N-forward primer and "US CDC" N3-forward primer binding regions. It is important that the kits to be used as diagnostic tests are designed specific to the regions with less nucleotide changes. Nucleotide changes may not be critical for DNA amplification for most PCR panels, but should be carefully monitored as they may affect the sensitivity of the assay. If the risk of alteration of the designed region is high, the primer - probe binding sites should be checked frequently and updated when necessary.


Assuntos
COVID-19 , SARS-CoV-2 , Teste para COVID-19 , Humanos , Nucleotídeos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade , Turquia
19.
BMJ Case Rep ; 14(8)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34433531

RESUMO

A 53-year-old woman was referred for medical evaluation of therapy-resistant dyslipidaemia accompanied by elevated creatine kinase levels. Because cessation or alteration of her medication did not improve laboratory abnormalities, hypothyroidism was considered, despite the fact that thyroid stimulating hormone levels were within the reference interval. On further evaluation, she was found to have panhypopituitarism and empty sella turcica as shown by MRI. These findings were unexpected since there was no clinical suspicion during detailed evaluation. When supplementary questions were asked, she brought up a history of severe postpartum haemorrhage 30 years ago, for which she underwent a hysterectomy. Based on these findings, the patient was diagnosed with Sheehan's syndrome. This syndrome is a rare but potentially life-threatening complication of postpartum haemorrhage, characterised by varying degrees of hypopituitarism that are most commonly presented many years after delivery. The patient recovered after adequate hormone replacement therapy.


Assuntos
Síndrome da Sela Vazia , Hipopituitarismo , Creatina Quinase , Feminino , Humanos , Hipopituitarismo/diagnóstico , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tireotropina
20.
Int J Biol Macromol ; 183: 35-44, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33901555

RESUMO

The study reports designing of a new, low-cost and environmentally friendly colorimetric and fluorometric sensor by using cellulose-based materials for detection and determination of Fe(III). To make powder cellulose (Cel) and filter paper (PCel) fluorescent, they were modified with hexamethylene diisocyanate (HMDI) and 4-sulfo-1,8-naphthalimide (Nap). Fluorescent Cel-Nap and PCel-Nap materials were used for spectroscopic detection of Fe(III). The working range of the designed sensor was determined as 1.0 × 10-5-4.5 × 10-5 M with a low limit of detection (LOD) (7.51 µM). Antimicrobial properties of cel-based compounds and Ag(I)-containing compounds were tested against five bacteria; Bacillus cereus, Streptococcus mutans, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and two fungi; Candida albicans and Candida tropicalis. The materials exhibited antimicrobial effects and their antifungal properties were more effective than their antibacterial properties.


Assuntos
Antibacterianos/farmacologia , Antifúngicos/farmacologia , Técnicas Biossensoriais , Celulose/farmacologia , Ferro/análise , Compostos de Prata/farmacologia , Antibacterianos/química , Antifúngicos/química , Bactérias/efeitos dos fármacos , Bactérias/crescimento & desenvolvimento , Candida/efeitos dos fármacos , Candida/crescimento & desenvolvimento , Celulose/química , Fluorometria , Isocianatos/química , Naftalimidas/química , Compostos de Prata/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...