Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Eur J Cardiothorac Surg ; 31(3): 482-5; discussion 485, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17239609

RESUMO

OBJECTIVE: LigaSure (Valleylab, Tyco Healthcare, Boulder, CO) is a novel instrument with widespread use in various surgical disciplines for vessel sealing. It uses heat energy to denature collagen and elastin and achieve vessel sealing. We investigated the safety of LigaSure in pulmonary arteries (PA) and veins (PV). METHODS: Twelve sheep were anesthetized and endotracheally intubated. Six underwent right lower lobectomy (Group 1) and six right upper lobectomy (Group 2). All of the vessels in both groups were divided with LigaSure. Diameters of vessels were measured. Intraoperatively, pulmonary artery pressures (PAP) were monitored in Group 1. Following vascular division, ephedrine was injected to increase PAP in Group 1. In Group 2, animals were followed and euthanized at 7 days. Both immediate and 7 day samples were obtained from divided vessel stumps. Conventional histology was done. Statistical analysis was performed using t-test and Fisher's exact test. RESULTS: Mean diameter of PAs (n=9) divided in Group 1 was 8.3mm (3-11) and of PVs (n=8) was 10.4mm (4-15). Mean PAP increased from 18 (27/9) to 27 (45/18)mmHg after ephedrine injection. Dehiscence rate was 2/6 in PAs and 3/6 in PVs larger than 9 mm in diameter. Mean diameter of PAs (n=8) divided in Group 2 was 5.7 mm (3-7) and of PVs (n=9) was 4.6mm (4-6). No early or late (7 days) vascular disruption was seen in Group 2. Bleeding incidence was significantly different between groups (Fisher's exact test p=0.015). Overall no dehiscence was observed in vessels less than 7 mm in diameter. Histology of intraoperative samples showed thermal injury and necrosis. Seven day samples showed short segment necrosis limited to the vessel wall, fibrosis, thrombus formation without inflammation, and minimal granulation tissue. CONCLUSIONS: LigaSure achieves perfect sealing in pulmonary vessels less than 7 mm in diameter in sheep intra- and postoperatively even following a pressure challenge. It can safely be used in segmental branches of PAs and PVs during open or thoracoscopic surgery.


Assuntos
Hemostasia Cirúrgica/instrumentação , Temperatura Alta/uso terapêutico , Artéria Pulmonar/cirurgia , Veias Pulmonares/cirurgia , Procedimentos Cirúrgicos Vasculares/instrumentação , Animais , Perda Sanguínea Cirúrgica/prevenção & controle , Hemostasia Cirúrgica/efeitos adversos , Hemostasia Cirúrgica/métodos , Ligadura/instrumentação , Ligadura/métodos , Desnaturação Proteica , Artéria Pulmonar/patologia , Veias Pulmonares/patologia , Carneiro Doméstico , Toracotomia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...