Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
CJC Open ; 2(6): 555-562, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33305216

RESUMO

BACKGROUND: Despite current physical activity (PA) guidelines, children spend an average of 1-3 hours/day playing video games. Some video games offer physically active components as part of gameplay. We sought to determine if these active video games (AVGs) can elicit at least moderate PA in children, identify game elements important for PA, and determine if they are fun to play. METHODS: Twenty children aged 8 to 16 years underwent cardiopulmonary exercise testing to determine their heart rate (HR) at ventilatory threshold. Participants played 2 different AVGs, and the gaming time that each participant's HR was above the HR thresholds for moderate and vigorous PA was determined. Gameplay elements that supported or inhibited active gameplay were also identified. Participants also completed questionnaires on physical activity, game engagement, and game experience. RESULTS: The Dance Central Spotlight and Kung-Fu for Kinect AVGs produced at least moderate PA, for a mean of 54.3% ± 29.5% and 87.8% ± 21.8% of gameplay time, respectively. Full-body movements, player autonomy, and self-efficacy were observed to be important elements of good AVG design. Although participants enjoyed these AVGs, they still preferred their favorite games (game engagement score of 1.82 ± 0.67 vs 0.95 ± 0.70 [Dance Central Spotlight] and 1.39 ± 0.37 [Kung Fu for Kinect]). CONCLUSIONS: AVGs can provide at least moderate PA and are enjoyable to play, but most popular video games do not incorporate active components. The implementation of government policies and a rating system concerning PA in video games may help address the widespread sedentary lifestyle of children.


CONTEXTE: Malgré les lignes directrices actuelles sur l'activité physique, les enfants passent en moyenne entre une et trois heures par jour à jouer à des jeux vidéo. Comme la jouabilité de certains jeux vidéo comporte des activités physiques, nous avons cherché à déterminer si les jeux vidéo dynamiques (JVD) pouvaient permettre aux enfants d'atteindre un degré d'activité physique au moins modéré, à cerner les éléments de jeu qui sont importants pour l'activité physique et à déterminer si ces jeux étaient amusants. MÉTHODOLOGIE: Nous avons soumis 20 enfants de 8 à 16 ans à des épreuves d'effort cardiopulmonaire pour déterminer leur fréquence cardiaque (FC) au seuil ventilatoire. Les participants ont joué à deux JVD différents et nous avons déterminé la durée pendant laquelle la FC de chaque participant était supérieure aux seuils de FC correspondant à une activité physique modérée et intense. Nous avons aussi cerné les éléments de la jouabilité qui favorisaient ou empêchaient la jouabilité dynamique. Les participants ont en outre rempli des questionnaires sur l'activité physique, l'intérêt des jeux et l'expérience de jeu. RÉSULTATS: Deux JVD, Dance Central Spotlight et Kung-Fu for Kinect, ont produit un degré d'activité physique au moins modéré pendant respectivement 54,3 % ± 29,5 % et 87,8 % ± 21,8 % de la durée de jouabilité. Nous avons constaté que les mouvements du corps entier, l'autonomie des joueurs et l'auto-efficacité étaient des éléments importants de la bonne conception d'un JVD. Les participants ont aimé ces JVD, mais ils préféraient toujours leurs jeux favoris (score d'intérêt à l'égard du jeu de 1,82 ± 0,67 vs 0,95 ± 0,70 [Dance Central Spotlight] et 1,39 ± 0,37 [Kung Fu for Kinect]). CONCLUSIONS: Les JVD semblent produire un degré d'activité physique au moins modéré et sont amusants, mais la plupart des jeux vidéo populaires ne font pas faire d'activité physique. La mise en œuvre de politiques gouvernementales et l'adoption d'un système de cotation concernant l'activité physique associée aux jeux vidéo pourraient permettre de s'attaquer au problème répandu que représente la sédentarité chez les enfants.

2.
Patient Educ Couns ; 103(7): 1326-1334, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32089389

RESUMO

OBJECTIVES: We sought to describe and analyze the quantitative and qualitative feedback obtained from participants and their caregivers of the Smart Heart study, a successful 12-month lifestyle intervention for children with overweight or obesity and congenital heart disease that provided remote lifestyle counseling, to improve future lifestyle interventions in children. METHODS: Thirty-six participants and caregivers were polled using a standard program evaluation questionnaire at the end of the intervention. Feedback was compiled into themes, and facilitators and barriers to program success were identified. RESULTS: There was a high level of satisfaction with the intervention and staff interactions as well as a low perceived burden of participation. There were also specific concerns, including mixed impressions regarding technology usage and a less impressive indication of actual impactful behavior change. CONCLUSIONS: The study identified five themes, and corresponding facilitators and barriers to participant compliance, from the Smart Heart intervention feedback and offered suggestions for improving future lifestyle behavioral intervention study designs in children. PRACTICE IMPLICATIONS: Remote smartphone counseling is effective and efficient. It is recommended that the counseling messages are specific, the counseling schedule is patient-centric, patient burden is limited, methods with immediate patient feedback are used and family is included when feasible.


Assuntos
Cuidadores , Estilo de Vida , Criança , Retroalimentação , Humanos , Obesidade , Sobrepeso
3.
J Hypertens ; 37(8): 1689-1698, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30950974

RESUMO

OBJECTIVES: The intima-media thickness of the common carotid artery (cIMT) is a good noninvasive surrogate marker for cardiovascular disease. Regular cIMT monitoring in children with congenital heart disease has great potential. We sought to determine which anthropomorphic and haemodynamic variables were significantly associated with the cIMT in paediatric patients with obesity and children with repaired coarctation of the aorta (CoA). METHODS: We measured the cIMT in 143 children aged 5 to less than 18 years including normal weight controls (n = 44), children with overweight/obesity (n = 73) and children with repaired CoA (n = 26). cIMT was compared and the association between the cIMT and patient characteristics, including obesity and blood pressure (BP), was investigated. RESULTS: BMI z score, sex and the presence of CoA were significant independent predictors of cIMT. The cIMT was significantly greater in children with overweight/obesity (0.53 ±â€Š0.06 mm) relative to normal weight controls (0.51 ±â€Š0.04 mm), as well as in CoA patients with abnormally high BP (0.57 ±â€Š0.08 mm) versus CoA patients with normal BP (0.52 ±â€Š0.05 mm) and controls (0.51 ±â€Š0.04 mm). CoA patients with normal BP did not have significantly increased cIMT. CONCLUSION: cIMT was positively associated with BMI z score, male sex and CoA repair in children. The increased cIMT in children with repaired CoA was because of those with abnormally high BP, which was masked in clinic for most of these patients. These findings warrant further investigations into the cIMT and other atherosclerotic risk factors to determine their potential clinical impact in these highly susceptible patients.


Assuntos
Coartação Aórtica/epidemiologia , Pressão Sanguínea/fisiologia , Espessura Intima-Media Carotídea , Hipertensão/epidemiologia , Adolescente , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Criança , Pré-Escolar , Humanos , Hipertensão/complicações , Obesidade Infantil
4.
J Cardiothorac Vasc Anesth ; 32(6): 2505-2511, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29903682

RESUMO

OBJECTIVES: There are substantial potential benefits to noninvasive cardiac monitoring methods, such as electrical cardiometry (EC), over more invasive methods, including significantly reduced risk of complications, lower up-front and operational costs, ease of use, and continuous monitoring. To take advantage of these technologies, clinical equivalence to currently established methods must be determined. The authors sought to determine if the noninvasive measurement of cardiac index (CI) by EC was clinically equivalent to thermodilution (TD) in adult patients with aortic stenosis (AS). DESIGN: This is a cross-sectional study comparing measurement devices in a single patient group. SETTING: Single-center, university teaching hospital. PARTICIPANTS: The study included 52 adult patients with aortic stenosis undergoing right heart catheterization. INTERVENTIONS: Cardiac output (CO) was measured concurrently using EC with an ICON device and TD in 52 participants with AS. CI values were to determine the accuracy and precision of EC in reference to TD. Percentage error (PE) was used to assess their clinical equivalence. The participants were divided further into groups (normal and overweight/obese) based on body mass index and the analysis was repeated. MEASUREMENTS AND MAIN RESULTS: CO measurement made by EC in adult patients with obesity or overweight was reduced significantly relative to TD. This was not observed in normal-weight adult AS patients. EC provided clinically equivalent measurements to TD for measuring CI in normal-weight adult AS patients (PE = 25.0%), but not for those adult AS patients with overweight or obesity (PE = 42.3%). CONCLUSION: Overall, the ICON device produced lower CO and index measurements relative to TD in adult patients with AS. Overweight and obesity also significantly affected the relative precision and accuracy of the ICON electrical cardiometric device to measure CI in these patients.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Obesidade/complicações , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo/fisiologia , Débito Cardíaco/fisiologia , Estudos Transversais , Impedância Elétrica , Feminino , Seguimentos , Humanos , Masculino , Obesidade/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sístole , Termodiluição/métodos
5.
Physiol Meas ; 39(5): 055003, 2018 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-29695645

RESUMO

OBJECTIVE: To evaluate the equivalence of the ICON® electrical cardiometry (EC) haemodynamic monitor to measure cardiac output (CO) relative to transthoracic Doppler echocardiography (TTE) in paediatric patients with repaired coarctation of the aorta (CoA). APPROACH: A group of n = 28 CoA patients and n = 27 matched controls were enrolled. EC and TTE were performed synchronously on each participant and CO measurements compared using linear regression and Bland-Altman analysis. The CoA group was further subdivided into two groups, with n = 10 and without n = 18 increased left ventricular outflow tract velocity (iLVOTv) for comparison. MAIN RESULTS: CO measurements from EC and TTE in controls showed a strong correlation (R = 0.80, p < 0.001) and an acceptable percentage error (PE) of 28.1%. However, combining CoA and control groups revealed a moderate correlation (R = 0.57, p < 0.001) and a poor PE (44.2%). We suspected that the CO in a subset of CoA participants with iLVOTv was overestimated by TTE. Excluding the iLVOTv CoA participants improved the correlation (R = 0.77, p < 0.001) and resulted in an acceptable PE of 31.2%. SIGNIFICANCE: CO measurements in paediatric CoA patients in the absence of iLVOTv are clinically equivalent between EC and TTE. The presence of iLVOTv may impact the accuracy of CO measurement by TTE, but not EC.


Assuntos
Aorta/fisiopatologia , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Débito Cardíaco , Ecocardiografia Doppler , Eletrocardiografia , Coartação Aórtica/diagnóstico , Estudos de Casos e Controles , Criança , Feminino , Hemodinâmica , Humanos , Masculino
6.
Front Pediatr ; 5: 269, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29326907

RESUMO

BACKGROUND: Children with overweight/obesity and congenital heart disease (CHD) are at increased cardiovascular risk. A lifestyle intervention may help reduce these risks. We sought to determine the feasibility of a smartphone-based lifestyle intervention to improve cardiovascular health outcomes in children with overweight/obesity and CHD. METHODS: We examined the effect of bi-weekly nutrition and fitness counseling delivered via smartphone over 12 months. Thirty-four youth, previously diagnosed with CHD and with overweight or obesity, participated in the intervention. They were divided into two groups depending on whether the heart disease required surgical correction (operated, n = 19) or not (non-operated, n = 15). Anthropometry, body composition cardiorespiratory exercise capacity, and cardio-metabolic risk factors were assessed at baseline, 6 months, and 12 months. RESULTS: Statistically significant decreases in waist circumference (WC), body mass index z-score, WC z-score, and waist to height ratio z-score were observed at 6 and 12 months in the operated group. A significant linear increase in lean body mass was observed in both groups. The study also had a high retention rate and a low attrition rate. CONCLUSION: The observed changes in anthropometry were positive with significant improvement to some cardiovascular and metabolic risk indicators. However, this was only observed in the operated group suggesting that other factors, such as perception of condition and self-efficacy, may influence lifestyle behaviors. The results from this pilot study clearly demonstrate the feasibility to perform a larger controlled study on remote lifestyle intervention in children with congenital heart defects and overweight or obesity.

7.
J Transl Med ; 7: 55, 2009 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-19580657

RESUMO

BACKGROUND: As gene expression signatures may serve as biomarkers, there is a need to develop technologies based on mRNA expression patterns that are adaptable for translational research. Xceed Molecular has recently developed a Ziplex technology, that can assay for gene expression of a discrete number of genes as a focused array. The present study has evaluated the reproducibility of the Ziplex system as applied to ovarian cancer research of genes shown to exhibit distinct expression profiles initially assessed by Affymetrix GeneChip analyses. METHODS: The new chemiluminescence-based Ziplex gene expression array technology was evaluated for the expression of 93 genes selected based on their Affymetrix GeneChip profiles as applied to ovarian cancer research. Probe design was based on the Affymetrix target sequence that favors the 3' UTR of transcripts in order to maximize reproducibility across platforms. Gene expression analysis was performed using the Ziplex Automated Workstation. Statistical analyses were performed to evaluate reproducibility of both the magnitude of expression and differences between normal and tumor samples by correlation analyses, fold change differences and statistical significance testing. RESULTS: Expressions of 82 of 93 (88.2%) genes were highly correlated (p < 0.01) in a comparison of the two platforms. Overall, 75 of 93 (80.6%) genes exhibited consistent results in normal versus tumor tissue comparisons for both platforms (p < 0.001). The fold change differences were concordant for 87 of 93 (94%) genes, where there was agreement between the platforms regarding statistical significance for 71 (76%) of 87 genes. There was a strong agreement between the two platforms as shown by comparisons of log2 fold differences of gene expression between tumor versus normal samples (R = 0.93) and by Bland-Altman analysis, where greater than 90% of expression values fell within the 95% limits of agreement. CONCLUSION: Overall concordance of gene expression patterns based on correlations, statistical significance between tumor and normal ovary data, and fold changes was consistent between the Ziplex and Affymetrix platforms. The reproducibility and ease-of-use of the technology suggests that the Ziplex array is a suitable platform for translational research.


Assuntos
Perfilação da Expressão Gênica/métodos , Luminescência , Medições Luminescentes/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Neoplasias Ovarianas/genética , Biomarcadores Tumorais , Linhagem Celular Tumoral , Sondas de DNA , Interpretação Estatística de Dados , Feminino , Expressão Gênica , Perfilação da Expressão Gênica/instrumentação , Humanos , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Reprodutibilidade dos Testes
8.
Atherosclerosis ; 191(1): 63-72, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16806233

RESUMO

Plasma lipid levels have been known to be risk factors for atherosclerosis for decades, and in recent years it has become accepted that inflammation is a crucial event in the pathogenesis of atherosclerosis. In this study, we investigated the relationship between plasma lipids and leukocytes by profiling and analyzing leukocyte gene expression in response to plasma lipid levels. We discovered several interesting patterns of leukocyte gene expression: (1) the expression of a number of immune response- and inflammation-related genes are correlated with plasma lipid levels; (2) genes involved in lipid metabolism and in the electron transport chain were positively correlated with triglycerides and low-density lipoprotein cholesterol (LDL) levels, and negatively correlated with high-density lipoprotein cholesterol (HDL) levels; (3) genes involved in platelet activation were negatively correlated with HDL levels; (4) transcription factors regulating lipogenesis-related genes were correlated with plasma lipid levels; (5) a number of genes correlated with plasma lipid levels were found to be located in the regions of known quantitative trait loci (QTLs) associated with hyperlipemia. Our findings suggest that leukocytes respond to changing plasma lipid levels by regulating a network of genes, including genes involved in immune response, and lipid and fatty acid metabolism.


Assuntos
Glicemia , Perfilação da Expressão Gênica , Leucócitos/metabolismo , Lipídeos/sangue , Adulto , Aterosclerose/metabolismo , Ácidos Graxos/metabolismo , Feminino , Regulação da Expressão Gênica , Humanos , Metabolismo dos Lipídeos , Masculino , Pessoa de Meia-Idade , Dados de Sequência Molecular
9.
J Lab Clin Med ; 147(3): 126-32, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16503242

RESUMO

In our genome-wide survey of gene expression in human peripheral blood cells using both an expressed sequence tag (EST) and a microarray hybridization approach, we identified the expression of a large proportion (approximately 80%) of the genes encoded in the human genome. Comparison of the peripheral blood transcriptome with genes expressed in nine different human tissue types revealed that expression of over 80% was shared with any given tissue. We also sought to determine whether those gene transcripts undetected by these methods were also expressed in peripheral blood cells. Using reverse-transcriptase-polymerase chain reaction, we detected additional tissue-specific gene transcripts including beta-myosin heavy chain (heart specific) and insulin (specific to pancreatic islet beta cells), in circulating blood cells. Arguably, the detection of low levels of tissue-specific transcripts could be considered products of "illegitimate" transcription; however, our study also demonstrates that environmental conditions affect the transcriptional regulation of insulin in the peripheral blood. We thus hypothesize that blood cells can act as sentinels of disease and that we could capitalize on this property of blood for the diagnosis/prognosis of disease (the "Sentinel Principle"). Peripheral blood is an ideal surrogate tissue as it is readily obtainable, provides a large biosensor pool in the form of gene transcripts, and response to changes in the macro- and micro-environments is detectable as alterations in the levels of these gene transcripts.


Assuntos
Sangue/metabolismo , Perfilação da Expressão Gênica , Técnicas de Diagnóstico Molecular/métodos , Transcrição Gênica/genética , Células Sanguíneas/metabolismo , Etiquetas de Sequências Expressas , Humanos , Cadeias Pesadas de Miosina/genética , Análise de Sequência com Séries de Oligonucleotídeos , Especificidade de Órgãos , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...