1.
Osteoporos Int ; 21(6): 969-76, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19693640

RESUMO

SUMMARY: A quantitative ultrasound (QUS) device for measurements at the proximal femur was developed and tested in vivo (Femur Ultrasound Scanner, FemUS). Hip fracture discrimination was as good as for DXA, and a high correlation with hip BMD was achieved. Our results show promise for enhanced QUS-based assessment of osteoporosis. INTRODUCTION: Dual X-ray absorptiometry (DXA) at the femur is the best predictor of hip fractures, better than DXA measurements at other sites. Calcaneal quantitative ultrasound (QUS) can be used to estimate the general osteoporotic fracture risk, but no femoral QUS measurement has been introduced yet. We developed a QUS scanner for measurements at the femur (Femur Ultrasound Scanner, FemUS) and tested its in vivo performance. METHODS: Using the FemUS device, we obtained femoral QUS and DXA on 32 women with recent hip fractures and 30 controls. Fracture discrimination and the correlation with femur bone mineral density (BMD) were assessed. RESULTS: Hip fracture discrimination using the FemUS device was at least as good as with hip DXA and calcaneal QUS. Significant correlations with total hip bone mineral density were found with a correlation coefficient R (2) up to 0.72 and a residual error of about one half of a T-score in BMD. CONCLUSIONS: QUS measurements at the proximal femur are feasible and show a good performance for hip fracture discrimination. Given the promising results, this laboratory prototype should be reengineered to a clinical applicable instrument. Our results show promise for further enhancement of QUS-based assessment of osteoporosis.


Assuntos
Densidade Óssea/fisiologia , Fêmur/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico por imagem , Absorciometria de Fóton/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Fêmur/fisiopatologia , Fraturas do Quadril/etiologia , Fraturas do Quadril/fisiopatologia , Humanos , Pessoa de Meia-Idade , Osteoporose Pós-Menopausa/complicações , Osteoporose Pós-Menopausa/diagnóstico por imagem , Osteoporose Pós-Menopausa/fisiopatologia , Fraturas por Osteoporose/fisiopatologia , Ultrassonografia
2.
Bone ; 40(1): 37-44, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16949896

RESUMO

Quantitative ultrasound (QUS) measurements at peripheral sites can be used to estimate osteoporotic fracture risk. However, measurements at these sites are less suitable to predict bone mineral density (BMD) or fracture risk at the central skeleton. We investigated whether direct QUS measurements at the femur would allow to estimate dual X-ray absorptiometry (DXA) BMD of the total proximal femur with errors comparable to established DXA accuracy errors. Two independent sets of femora were measured in Kiel (6 f, 4 m, age: 55-90) and Paris (19 f, 20 m age: 45-95) using different benchtop systems in the two laboratories. The femora were scanned in transverse transmission mode using focused US transducers of 500 kHz center frequency. The QUS values were averaged over a region similar to the total hip region of dual X-ray absorptiometry (DXA) measurements. BMD was measured using DXA. SOS and BMD correlated significantly (p<0.0001) in both data sets (R2=0.81-0.93). Correlations between BUA and BMD were also significant at p<0.001, but correlation coefficients were lower (R2=0.61-0.75). Residual errors for the estimation of BMD were 8%-10% for SOS as predictor, and 14%-16% for BUA as predictor. The residual error of 8 to 10% for the estimation of BMD from SOS is comparable to variabilities among different DXA femur subregions and accuracy errors of femoral DXA measurements caused by the impact of soft tissue. It is substantially smaller than the errors of 13% for the estimation of total femur BMD from spine BMD, 14% for the estimation of total femur BMD from calcaneus SOS or 16% for the estimation of ash weight from DXA. The results of the study show that SOS is able to predict total BMD with adequate accuracy. If femoral BMD could be obtained in vivo with comparable accuracy, femoral QUS would be suited for the assessment of bone status at one of the main osteoporotic fracture sites.


Assuntos
Densidade Óssea , Fêmur/diagnóstico por imagem , Ultrassonografia/normas , Absorciometria de Fóton , Cadáver , Feminino , Humanos , Ultrassom
3.
Calcif Tissue Int ; 77(3): 186-92, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16151672

RESUMO

Bone mineral density (BMD) measured with dual energy X-ray absorptiometry (DXA) techniques is the current gold standard for osteoporotic fracture risk prediction. Quantitative ultrasound (QUS) techniques in transmission measurements are, however, increasingly recognized as an alternative approach. It is feasible to select different QUS methods, one type being optimized to assess microarchitectural properties of bone structure and another to assess BMD. Broadband ultrasonic attenuation (BUA) and ultrasonic velocity (UV) measured on the proximal human femur have been shown to be both significantly correlated with BMD. However, a great diversity of algorithms has been reported to measure the time-of-flight used to derive UV values. The purpose of this study was to determine which procedure results in the optimal BMD prediction at the proximal femur from ultrasound measurements. Thirty-eight excised human femurs were measured in transmission with a pair of focused 0.5-MHz central frequency transducers. Two-dimensional scans were performed and radiofrequency (RF) signals were recorded digitally at each scan position. BUA was estimated and eight different signal processing techniques were performed to estimate UV. For each signal-processing technique UV was compared to BMD. We show that the best prediction of BMD was obtained with signal-processing techniques taking into account only the first part of the transmitted signal (r2BMD-SOS = 0.86). Moreover, we show that a linear multiple regression using both BUA and speed of sound (SOS) and applied to site-matched regions of interest improved the accuracy of BMD predictions (r2BMD-SOS/BUA = 0.95). Our results demonstrate that selecting specific signal-processing methods for QUS variables allows optimal assessment of BMD. Correlation is sufficiently high that this specific QUS method can be considered as a good surrogate of BMD.


Assuntos
Densidade Óssea , Fêmur/diagnóstico por imagem , Fêmur/metabolismo , Ultrassonografia/métodos , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...