Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 24(10): 2633-2643, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38639159

RESUMO

This study describes the function, optimization, and demonstration of a new class of passive, low-cost microfluidic flow meters based on birefringent chitosan biomembranes analyzed by polarized microscopy. We subjected the membrane to dynamic flow conditions while monitoring the real-time response of its optical properties. We obtained figures of merit, including the linear response operating range (0 to 65 µL min-1), minimum response time (250 ms), sensitivity (2.03% × 10-3 µL-1 min), and minimum sensor longevity (1 week). In addition, possible sources of interference were identified. Finally, we demonstrate the membrane as a low-cost flow rate measurement device for the close loop control of a commercial pressure-driven pump. Preliminary experiments using a basic PID controller with the membrane-based flow rate measurement device showed that stable control could be achieved and the system could reach steady-state behavior in less than 15 seconds. Analysis of fundamental limits to sensor response time indicate the potential for faster steady-state behaviour.

2.
Lab Chip ; 23(16): 3561-3570, 2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37403603

RESUMO

We present a generalizable fabrication method for a new class of analytical devices that merges virtually any microfluidic design with high-sensitivity on-chip attenuated total reflection (ATR) sampling using any standard Fourier transform infrared (FTIR) spectrometer. Termed "spectIR-fluidics", a major design feature is the integration of a multi-groove silicon ATR crystal into a microfluidic device, compared with previous approaches in which the ATR surface served as a structural support for the entire device. This was accomplished by the design, fabrication, and aligned bonding of a highly engineered ATR sensing layer, which con```tains a seamlessly embedded ATR crystal on the channel side and an optical access port that matched the spectrometer light path characteristics at the device exterior. The refocused role of the ATR crystal as a dedicated analytical element, combined with optimized light coupling to the spectrometer, results in limits of detection as low as 540 nM for a D-glucose solution, arbitrarily complex channel features that are fully enclosed, and up to 18 world-to-chip connections. Three purpose-built spectIR-fluidic cartridges are used in a series of validation experiments followed by several point-of-application studies on biofilms from the gut microbiota of plastic-consuming insects using a small portable spectrometer.


Assuntos
Biofilmes , Microfluídica , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Espectrofotometria Infravermelho , Dispositivos Lab-On-A-Chip
3.
Sci Rep ; 13(1): 3047, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36810614

RESUMO

A particle damper is applied to suppress the longitudinal vibration of underwater vehicle shafting in order to reduce vibration level and improve silence and stealth of underwater vehicles. The model of rubber-coated steel particle damper was established with discrete element method and PFC3D simulation software, the damping energy consumption law of collision and friction between particle and damper and between particle and particle investigated, the effects of particle radius, mass filling ratio, cavity length, excitation frequency, excitation amplitude, rotating speed and both stacking and motion states of particles on the system vibration suppression were discussed, and the bench test was carried out to verify the law. It revealed the mechanism of longitudinal vibration suppression of particle damping, established the intrinsic relationship between of total energy consumption of particle and vibration of system, and put forward the evaluating method of longitudinal vibration suppression effect by total energy consumption of particle and vibration reduction ratio. The research results show that the mechanical model of particle damper is reasonable and the simulation data is reliable; the rotating speed, mass filling ratio and cavity length have significant effects on the total energy consumption of particle and vibration reduction ratio.

4.
Anal Chem ; 93(42): 14076-14087, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34636233

RESUMO

We present a novel spectroscopy accessory that can easily convert any Fourier transform infrared (FTIR) spectrometer into a fully automated mapping and assaying system. The accessory uses a multiridge attenuated total reflection (ATR) wafer as the sensing element coupled with a moving aperture that is used to select the regions of interest on the wafer. In this demonstration, the accessory is combined with a series of parallel micropatterned channels, which are positioned co-linear with the light-coupling ridges on the opposite side of the ATR wafer. The ATR spectroscopy microfluidic assay accessory (ASMAA) was used in continuous mapping mode to scan perpendicular to the ATR ridges, revealing complex but repeatable oscillations in the spectral intensities. To understand this behavior, the light path through the optical components was simulated with consideration of the aperture position, ridge-to-channel alignment, and excitation beam profile. With this approach, the simulation reproduced the experimental mapping results and provided evidence that the measurement position and area changed with the aperture position. To demonstrate the assay mode, we obtained spectra along the centerline of individual microchannels and determined noise baselines and limits of detection.


Assuntos
Microfluídica , Análise de Fourier , Cintilografia , Espectroscopia de Infravermelho com Transformada de Fourier
5.
Anal Chem ; 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34133116

RESUMO

Microfluidic bioanalytical platforms are driving discoveries from synthetic biology to the health sciences. In this work, we present a platform for in vivo live-cell imaging and automated species detection in mixed cyanobacterial biofilms from cold climate environments. Using a multimodal microscope with custom optics applied to a chip with six parallel growth channels, we monitored biofilm dynamics via continuous imaging at natural irradiance levels. Machine learning algorithms were applied to the collected hyperspectral images for automatic segmentation of mixed-species biofilms into individual species of cyanobacteria with similar filamentous morphology. The coupling of microfluidic technology with modern multimodal imaging and computer vision systems provides a versatile platform for the study of cause-and-effect scenarios of cyanobacterial biofilms, which are important elements of many ecosystems, including lakes and rivers of the polar regions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...