Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Psychol ; 15: 1351425, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855302

RESUMO

Trustworthiness is the most significant predictor of trust and has a significant impact on people's levels of trust. Most trustworthiness-related research is empirical, and while it has a long history, it is challenging for academics to get insights that are applicable to their fields of study and to successfully transfer fragmented results into practice. In order to grasp their dynamic development processes through the mapping of network knowledge graphs, this paper is based on the Web of Science database and uses CiteSpace (6.2.R4) software to compile and visualize the 1,463 publications on trustworthy studies over the past 10 years. This paper aims to provide valuable references to theoretical research and the practice of Trustworthiness. The findings demonstrate that: over the past 10 years, trustworthiness-related research has generally increased in volume; trustworthiness research is concentrated in industrialized Europe and America, with American research findings having a bigger global impact; The University of California System, Harvard University, and Yale University are among the high-production institutions; the leading figures are represented by Alexander Todorov, Marco Brambilla, Bastian Jaeger, and others; the core authors are distinguished university scholars; however, the level of cooperation of the core author needs to be improved. The primary journal for publishing research on trustworthiness is the Journal of Personality and Social Psychology and Biology Letters. In addition, the study focuses on three distinct domains, involving social perception, facial clues, and artificial intelligence.

2.
Front Pharmacol ; 14: 1215307, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37841910

RESUMO

Introduction: In this study, we conducted a systematic review and meta-analysis to judge the effects of metformin on acute respiratory distress syndrome (ARDS) in a comprehensive and quantitative manner. Methods: We included studies that tested the effects of metformin on ALI or ARDS in in vivo studies. We excluded literature from which data could not be extracted or obtained. Electronic search was conducted to retrieve relevant literature from public databases, including PubMed, Web of Science, Embase, Scopus, and the Cochrane Central Register of Controlled Trials (inception to July 2023). Moreover, ProQuest Dissertations and Theses Global, Google Scholar, and Baidu scholar were inquired. Retrieved literature was screened and evaluated by pairs of reviewers independently according to pre-stated criteria. The Systematic Review Center for Laboratory Animal Experimentation risk of bias tool was used to evaluate the methodological quality of eligible literature. No restriction was exerted on publication status or language. Results: Fifteen preclinical studies were analyzed in this meta-analysis. Pooled results showed metformin effectively decreased pulmonary wet-to-dry weight ratios [SMD = -2.67 (-3.53 to -1.81), I2 = 56.6%], protein content [SMD = -3.74 (-6.76 to -0.72), I2 = 86.7%] and neutrophils [SMD = -3.47 (-4.69 to -2.26), I2 = 0%] in BALF, pulmonary malondialdehyde [SMD = -1.98 (-3.77 to -0.20), I2 = 74.2%] and myeloperoxidase activity [SMD = -3.15 (-4.79 to -1.52), I2 = 74.5%], lung injury scores [SMD = -4.19 (-5.65 to -2.74), I2 = 69.1%], and mortality at 24 h [RR = 0.43 (0.24-0.76), I2 = 0%] as well as 48 and 72 h. Conclusion: Metformin inhibited pulmonary inflammation and oxidative stress and improved experimental lung injury and survival rates in animal models of ARDS. Results from randomized controlled trials are needed.

3.
Medicine (Baltimore) ; 101(24): e29425, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35713451

RESUMO

PURPOSE: To explore the offset distribution of pupillary centres, the offset between the pupil centre and the coaxially sighted corneal light reflex (P-Dist) and their correlation in femtosecond laser combined with excimer laser in situ keratomileusis. METHODS: Randomly selected 194 patients (398 eyes) who underwent femtosecond-assisted laser in situ keratomileusis with preoperative use of WaveLight Allegro Topolyzer Corneal Topography (WaveLight Laser Technologies AG, Erlangen, Germany) to measure the pupil size and centre position. The P-Dist of the patients was recorded by the X and Y axis eyeball tracking adjustment program of the WaveLight Eagle Vision EX500 excimer laser system. RESULTS: The P-Dist was 0.214 ±â€Š0.092 mm in the right eyes and 0.228 ±â€Š0.105 mm in the left eyes (P = .041). Under scotopic conditions, the pupil centre of left eye X-axis was -0.046 ±â€Š0.091 mm, the right eye was -0.152 ±â€Š0.084 mm, with significant differences (P = .015), and the Y-axis direction showed no significant changes (P = .062). The white to white was positively correlated with changes of pupil diameter (scotopic pupil diameter-photopic pupil diameter) (r = 0.270, P < .001). The equivalent spherical mirror and measured centroid shift were negatively correlated (r = -0.214, P = .002). CONCLUSION: The angle kappa of the right eye is smaller than that of the left eye and from scotopic to photopic condition, the pupil centroid shift of both eyes to the nasal inferior side. If the cornea is too large, the low illumination environment should be maintained during the operation to improve the efficiency of pupil matching.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Córnea/cirurgia , Topografia da Córnea , Humanos , Lasers de Excimer , Miopia/cirurgia , Refração Ocular
4.
J Craniofac Surg ; 32(3): 1054-1058, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33252528

RESUMO

PURPOSE: To investigate dynamic pupil changes after orbital blowout fracture repair. To compare postoperative changes in under photopic and mesopic pupil size and center position after orbital blowout fracture repair surgery. METHODS: The study evaluated 19 eyes. Pupils were imaged for pupil size and center position before and 3 months after orbital blowout fracture repair surgery. Pupil size changes were measured, and the correlation between preoperative and postoperative pupil centroid shift was evaluated. RESULTS: After repair, operative eyes exhibited a growth of 9.3% ±â€Š8.6% in pupil size, and contralateral eyes showed a growth of 8.6% ±â€Š8.2% (P = 0.011, P = 0.007). Similar findings were noted in mesopic conditions. Under mesopic conditions, the pupil of operative eyes in medial orbital wall fracture deviated 0.030 ±â€Š0.019 mm towards the nasal side along the X-axis (P = 0.031). The postoperative orbital floor fracture group demonstrated statistical significance at a spatial frequency of 5 (P = 0.041). CONCLUSIONS: Orbital blowout fracture repair surgery affects pupil size and center position.


Assuntos
Fraturas Orbitárias , Ossos Faciais , Humanos , Órbita , Fraturas Orbitárias/cirurgia , Pupila , Estudos Retrospectivos
5.
J Ophthalmol ; 2020: 9873504, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33083053

RESUMO

PURPOSE: To analyze the distribution of the offset between the pupil center and the coaxially sighted corneal light reflex (P-Dist), the effects of 50% and 100% angle kappa adjustments on refractive and visual quality in patients with moderate myopia were investigated. METHODS: A randomly selected 254 patients (254 eyes) with moderate myopia who underwent femtosecond laser-combined LASIK were examined. During the operation, the P-Dist of the patients was recorded by the x- and y-axis eyeball-tracking adjustment program of the WaveLight Eagle Vision EX500 excimer laser system. Preoperatively and 3 months postoperatively, the WaveLight® ALLEGRO Topolyzer was used to measure the pupil size and center position, and the wavefront sensor was used to measure the wavefront aberrations. The visual function tester (OPTEC 6500) measured contrast sensitivity. RESULTS: The average P-Dist was 0.220 ± 0.102 mm. When the P-Dist >0.220 mm, the postoperative residual cylinder was 0.29 ± 0.34 D in the group with the 50% adjustment and 0.40 ± 0.32 D in the 100% group, which was significantly higher than the 50% group (P=0.036). The coma was 0.21 ± 0.17 µm in the 50% adjusted group and 0.34 ± 0.25 µm in the 100% group, which was significantly higher than that in the 50% group (P=0.021). At the 1.5 c/d spatial frequency, contrast sensitivity in the adjusted 100% group was significantly lower than that in the 50% group under visual glare conditions (P=0.039). CONCLUSION: The postoperative visual acuity and spherical equivalent were not affected in the two groups. However, when P-Dist >0.220 mm, the residual astigmatism and coma were lower in the 50% group. Individualized operations for those with moderate myopia and large-angle kappa in which 100% adjustment is chosen may not result in a better visual quality effect than 50%.

6.
FEBS J ; 285(21): 4071-4081, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30188605

RESUMO

The phlda3 gene encodes a small, 127-amino acid protein with only a PH domain, and is involved in tumor suppression, proliferation of islet ß-cells, insulin secretion, glucose tolerance, and liver injury. However, the role of phlda3 in vascular development is unknown. Here, we show that phlda3 overexpression decreases the expression levels of hemangioblast markers scl, fli1, and etsrp and intersegmental vessel (ISV) markers flk1 and cdh5, and disrupts ISV development in tg(flk1:GFP) and tg(fli1:GFP) zebrafish. Moreover, phlda3 overexpression inhibits the activation of protein kinase B (AKT) in zebrafish embryos, and the developmental defects of ISVs by phlda3 overexpression were reversed by the expression of a constitutively active form of AKT. These data suggest that phlda3 is a negative regulator of hemangioblast specification and ISV development via AKT signaling.


Assuntos
Vasos Sanguíneos/embriologia , Embrião não Mamífero/patologia , Hemangioblastos/patologia , Neovascularização Patológica , Proteínas Nucleares/metabolismo , Proteínas de Peixe-Zebra/metabolismo , Peixe-Zebra/embriologia , Animais , Embrião não Mamífero/metabolismo , Regulação da Expressão Gênica no Desenvolvimento , Hemangioblastos/metabolismo , Proteínas Nucleares/genética , Proteínas Proto-Oncogênicas c-akt/metabolismo , Transdução de Sinais , Peixe-Zebra/fisiologia , Proteínas de Peixe-Zebra/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...