Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Biosens Bioelectron ; 260: 116430, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38815465

RESUMO

Sweat contains abundant physiological and metabolic data to evaluate an individual's physical health. Since the non-exercise sweat secretion rate is low, with an average value of 1-10 µl h-1 cm-2, sweat is generally collected during exercise for existing wearable sweat sensors. To expand their applications to include daily scenarios, these sensors developed for sports and fitness are challenged by the difficulty of collecting trace amounts of sweat. This study proposes a wearable patch inspired by the hierarchical structure of Sarracenia trichomes, allowing for the spontaneous and fast collection of a small amount of secreted sweat. The patch contains microfluidic channels featuring a 20 µm-wide rib structure, fully utilizing the capillary force, thereby eliminating the issue of sweat hysteresis. Furthermore, with only 0.5 µl of the sweat secreted at the collection site, it can converge on the detection medium located within the center reservoir. Volunteer verification demonstrated a twofold increase in sweat collection efficiency compared to traditional wearable patches. This patch serves as an efficient sweat-collection configuration, promising potential for diverse in situ sweat colorimetric analyses.


Assuntos
Técnicas Biossensoriais , Desenho de Equipamento , Suor , Dispositivos Eletrônicos Vestíveis , Suor/química , Humanos , Técnicas Biossensoriais/instrumentação , Colorimetria/instrumentação
2.
Adv Mater ; 36(15): e2307782, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38303684

RESUMO

Bio/ecoresorbable electronic systems create unique opportunities in implantable medical devices that serve a need over a finite time period and then disappear naturally to eliminate the need for extraction surgeries. A critical challenge in the development of this type of technology is in materials that can serve as thin, stable barriers to surrounding ground water or biofluids, yet ultimately dissolve completely to benign end products. This paper describes a class of inorganic material (silicon oxynitride, SiON) that can be formed in thin films by plasma-enhanced chemical vapor deposition for this purpose. In vitro studies suggest that SiON and its dissolution products are biocompatible, indicating the potential for its use in implantable devices. A facile process to fabricate flexible, wafer-scale multilayer films bypasses limitations associated with the mechanical fragility of inorganic thin films. Systematic computational, analytical, and experimental studies highlight the essential materials aspects. Demonstrations in wireless light-emitting diodes both in vitro and in vivo illustrate the practical use of these materials strategies. The ability to select degradation rates and water permeability through fine tuning of chemical compositions and thicknesses provides the opportunity to obtain a range of functional lifetimes to meet different application requirements.


Assuntos
Implantes Absorvíveis , Eletrônica , Água/química
3.
ACS Appl Mater Interfaces ; 15(38): 45475-45484, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37703433

RESUMO

Hydrogen-containing nanocrystalline carbon films (n-C:H) with amorphous-nanocrystalline hydrocarbon composite structures exhibit excellent properties in diverse applications. Plasma-enhanced chemical vapor deposition (PECVD) is commonly employed to prepare n-C:H films due to its ability to create an adjustable deposition environment and control film compositions. However, the atomic-scale growth mechanism of n-C:H remains poorly understood, obstructing the design of the appropriate deposition parameters and film compositions. This paper employs a state-of-the-art hybrid molecular dynamics-time-stamped force-biased Monte Carlo model (MD/tfMC) to simulate the plasma-assisted growth of n-C:H. Our results reveal that optimizing the energy of ion bombardments, deposition temperature, and precursor's H:C ratio is crucial for achieving the nucleation and growth of highly ordered n-C:H films. These findings are further validated through experimental observations and density functional theory calculations, which show that hydrogen atoms can promote the formation of nanocrystalline carbon through chemical catalytic processes. Additionally, we find that the crystallinity reaches its optimum when the H/C ratio is equal to 1. These theoretical insights provide an effective strategy for the controlled preparation of hydrogen-containing nanocrystalline carbon films.

4.
Curr Biol ; 33(20): 4330-4342.e5, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37734375

RESUMO

Many species living in groups can perform prosocial behaviors via voluntarily helping others with or without benefits for themselves. To provide a better understanding of the neural basis of such prosocial behaviors, we adapted a preference lever-switching task in which mice can prevent harm to others by switching from using a lever that causes shocks to a conspecific one that does not. We found the harm avoidance behavior was mediated by self-experience and visual and social contact but not by gender or familiarity. By combining single-unit recordings and analysis of neural trajectory decoding, we demonstrated the dynamics of anterior cingulate cortex (ACC) neural activity changes synchronously with the harm avoidance performance of mice. In addition, ACC neurons projected to the mediodorsal thalamus (MDL) to modulate the harm avoidance behavior. Optogenetic activation of the ACC-MDL circuit during non-preferred lever pressing (nPLP) and inhibition of this circuit during preferred lever pressing (PLP) both resulted in the loss of harm avoidance ability. This study revealed the ACC-MDL circuit modulates prosocial behavior to avoid harm to conspecifics and may shed light on the treatment of neuropsychiatric disorders with dysfunction of prosocial behavior.


Assuntos
Giro do Cíngulo , Comportamento de Ajuda , Camundongos , Animais , Giro do Cíngulo/fisiologia , Tálamo/fisiologia , Neurônios/fisiologia
5.
Front Neurosci ; 17: 1171612, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37662112

RESUMO

Learning is a complex process, during which our opinions and decisions are easily changed due to unexpected information. But the neural mechanism underlying revision and correction during the learning process remains unclear. For decades, prediction error has been regarded as the core of changes to perception in learning, even driving the learning progress. In this article, we reviewed the concept of reward prediction error, and the encoding mechanism of dopaminergic neurons and the related neural circuities. We also discussed the relationship between reward prediction error and learning-related behaviors, including reversal learning. We then demonstrated the evidence of reward prediction error signals in several neurological diseases, including Parkinson's disease and addiction. These observations may help to better understand the regulatory mechanism of reward prediction error in learning-related behaviors.

6.
Mater Horiz ; 10(11): 4992-5003, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37641877

RESUMO

Systems for capture, storage and analysis of eccrine sweat can provide insights into physiological health status, quantify losses of water, electrolytes, amino acids and/or other essential species, and identify exposures to adverse environmental species or illicit drugs. Recent advances in materials and device designs serve as the basis for skin-compatible classes of microfluidic platforms and in situ colorimetric assays for precise assessments of sweat rate, sweat loss and concentrations of wide-ranging types of biomarkers in sweat. This paper presents a set of findings that enhances the performance of these systems through the use of microfluidic networks, integrated valves and microscale optical cuvettes formed by three dimensional printing in hard/soft hybrid materials systems, for accurate spectroscopic and fluorometric assays. Field studies demonstrate the capability of these microcuvette systems to evaluate the concentrations of copper, chloride, and glucose in sweat, along with the pH of sweat, with laboratory-grade accuracy and sensitivity.


Assuntos
Microfluídica , Suor , Suor/química , Suor/metabolismo , Microfluídica/métodos , Dispositivos Lab-On-A-Chip , Epiderme , Pele/química , Pele/metabolismo
7.
Transl Psychiatry ; 13(1): 79, 2023 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-36878900

RESUMO

Animals need discriminating auditory fear memory (DAFM) to survive, but the related neural circuits of DAFM remain largely unknown. Our study shows that DAFM depends on acetylcholine (ACh) signal in the auditory cortex (ACx), which is projected from the nucleus basalis (NB). At the encoding stage, optogenetic inhibition of cholinergic projections of NB-ACx obfuscates distinct tone-responsive neurons of ACx recognizing from fear-paired tone to fear-unpaired tone signals, while simultaneously regulating the neuronal activity and reactivation of basal lateral amygdala (BLA) engram cells at the retrieval stage. This NBACh-ACx-BLA neural circuit for the modulation of DAFM is especially dependent on the nicotinic ACh receptor (nAChR). A nAChR antagonist reduces DAFM and diminishes the increased magnitude of ACx tone-responsive neuronal activity during the encoding stage. Our data suggest a critical role of NBACh-ACx-BLA neural circuit in DAFM: manipulation of the NB cholinergic projection to the ACx via nAChR during the encoding stage affects the activation of ACx tone-responsive neuron clusters and the BLA engram cells during the retrieval stage, thus modulating the DAFM.


Assuntos
Córtex Auditivo , Receptores Nicotínicos , Animais , Neurônios Colinérgicos , Acetilcolina , Medo , Niacinamida , Colinérgicos/farmacologia
9.
Nat Commun ; 13(1): 5571, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36137999

RESUMO

In vivo optogenetics and photopharmacology are two techniques for controlling neuronal activity that have immense potential in neuroscience research. Their applications in tether-free groups of animals have been limited in part due to tools availability. Here, we present a wireless, battery-free, programable multilateral optofluidic platform with user-selected modalities for optogenetics, pharmacology and photopharmacology. This system features mechanically compliant microfluidic and electronic interconnects, capabilities for dynamic control over the rates of drug delivery and real-time programmability, simultaneously for up to 256 separate devices in a single cage environment. Our behavioral experiments demonstrate control of motor behaviors in grouped mice through in vivo optogenetics with co-located gene delivery and controlled photolysis of caged glutamate. These optofluidic systems may expand the scope of wireless techniques to study neural processing in animal models.


Assuntos
Neurociências , Optogenética , Animais , Encéfalo/fisiologia , Glutamatos , Camundongos , Optogenética/métodos , Tecnologia sem Fio
10.
Science ; 377(6601): 109-115, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35771907

RESUMO

Implantable devices capable of targeted and reversible blocking of peripheral nerve activity may provide alternatives to opioids for treating pain. Local cooling represents an attractive means for on-demand elimination of pain signals, but traditional technologies are limited by rigid, bulky form factors; imprecise cooling; and requirements for extraction surgeries. Here, we introduce soft, bioresorbable, microfluidic devices that enable delivery of focused, minimally invasive cooling power at arbitrary depths in living tissues with real-time temperature feedback control. Construction with water-soluble, biocompatible materials leads to dissolution and bioresorption as a mechanism to eliminate unnecessary device load and risk to the patient without additional surgeries. Multiweek in vivo trials demonstrate the ability to rapidly and precisely cool peripheral nerves to provide local, on-demand analgesia in rat models for neuropathic pain.


Assuntos
Implantes Absorvíveis , Bloqueio Nervoso , Neuralgia , Manejo da Dor , Nervos Periféricos , Animais , Materiais Biocompatíveis , Bloqueio Nervoso/instrumentação , Neuralgia/terapia , Manejo da Dor/instrumentação , Nervos Periféricos/fisiopatologia , Ratos
11.
World J Emerg Med ; 12(4): 287-292, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34512825

RESUMO

BACKGROUND: This study aims to compare the epidemiological, clinical and laboratory characteristics between patients with coronavirus disease (COVID-19) and influenza A (H1N1), and to develop a differentiating model and a simple scoring system. METHODS: We retrospectively analyzed the data from patients with COVID-19 and H1N1. The logistic regression model based on clinical and laboratory characteristics was constructed to distinguish COVID-19 from H1N1. Scores were assigned to each of independent discrimination factors based on their odds ratios. The performance of the prediction model and scoring system was assessed. RESULTS: A total of 236 patients were recruited, including 20 COVID-19 patients and 216 H1N1 patients. Logistic regression revealed that age >34 years, temperature ≤37.5 °C, no sputum or myalgia, lymphocyte ratio ≥20% and creatine kinase-myocardial band isoenzyme (CK-MB) >9.7 U/L were independent differentiating factors for COVID-19. The area under curves (AUCs) of the prediction model and scoring system in differentiating COVID-19 from H1N1 were 0.988 and 0.962, respectively. CONCLUSIONS: There are certain differences in clinical and laboratory features between patients with COVID-19 and H1N1. The simple scoring system may be a useful tool for the early identification of COVID-19 patients from H1N1 patients.

12.
Nat Mater ; 20(11): 1559-1570, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34326506

RESUMO

Flexible electronic/optoelectronic systems that can intimately integrate onto the surfaces of vital organ systems have the potential to offer revolutionary diagnostic and therapeutic capabilities relevant to a wide spectrum of diseases and disorders. The critical interfaces between such technologies and living tissues must provide soft mechanical coupling and efficient optical/electrical/chemical exchange. Here, we introduce a functional adhesive bioelectronic-tissue interface material, in the forms of mechanically compliant, electrically conductive, and optically transparent encapsulating coatings, interfacial layers or supporting matrices. These materials strongly bond both to the surfaces of the devices and to those of different internal organs, with stable adhesion for several days to months, in chemistries that can be tailored to bioresorb at controlled rates. Experimental demonstrations in live animal models include device applications that range from battery-free optoelectronic systems for deep-brain optogenetics and subdermal phototherapy to wireless millimetre-scale pacemakers and flexible multielectrode epicardial arrays. These advances have immediate applicability across nearly all types of bioelectronic/optoelectronic system currently used in animal model studies, and they also have the potential for future treatment of life-threatening diseases and disorders in humans.


Assuntos
Implantes Absorvíveis , Adesivos , Animais , Condutividade Elétrica , Eletrônica
13.
Nat Neurosci ; 24(7): 1035-1045, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33972800

RESUMO

Advanced technologies for controlled delivery of light to targeted locations in biological tissues are essential to neuroscience research that applies optogenetics in animal models. Fully implantable, miniaturized devices with wireless control and power-harvesting strategies offer an appealing set of attributes in this context, particularly for studies that are incompatible with conventional fiber-optic approaches or battery-powered head stages. Limited programmable control and narrow options in illumination profiles constrain the use of existing devices. The results reported here overcome these drawbacks via two platforms, both with real-time user programmability over multiple independent light sources, in head-mounted and back-mounted designs. Engineering studies of the optoelectronic and thermal properties of these systems define their capabilities and key design considerations. Neuroscience applications demonstrate that induction of interbrain neuronal synchrony in the medial prefrontal cortex shapes social interaction within groups of mice, highlighting the power of real-time subject-specific programmability of the wireless optogenetic platforms introduced here.


Assuntos
Optogenética/instrumentação , Comportamento Social , Tecnologia sem Fio/instrumentação , Animais , Camundongos
14.
BMC Nephrol ; 22(1): 176, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33985459

RESUMO

BACKGROUND: Combining tubular damage and functional biomarkers may improve prediction precision of acute kidney injury (AKI). Serum cystatin C (sCysC) represents functional damage of kidney, while urinary N-acetyl-ß-D-glucosaminidase (uNAG) is considered as a tubular damage biomarker. So far, there is no nomogram containing this combination to predict AKI in septic cohort. We aimed to compare the performance of AKI prediction models with or without incorporating these two biomarkers and develop an effective nomogram for septic patients in intensive care unit (ICU). METHODS: This was a prospective study conducted in the mixed medical-surgical ICU of a tertiary care hospital. Adults with sepsis were enrolled. The patients were divided into development and validation cohorts in chronological order of ICU admission. A logistic regression model for AKI prediction was first constructed in the development cohort. The contribution of the biomarkers (sCysC, uNAG) to this model for AKI prediction was assessed with the area under the receiver operator characteristic curve (AUC), continuous net reclassification index (cNRI), and incremental discrimination improvement (IDI). Then nomogram was established based on the model with the best performance. This nomogram was validated in the validation cohort in terms of discrimination and calibration. The decision curve analysis (DCA) was performed to evaluate the nomogram's clinical utility. RESULTS: Of 358 enrolled patients, 232 were in the development cohort (69 AKI), while 126 in the validation cohort (52 AKI). The first clinical model included the APACHE II score, serum creatinine, and vasopressor used at ICU admission. Adding sCysC and uNAG to this model improved the AUC to 0.831. Furthermore, incorporating them significantly improved risk reclassification over the predictive model alone, with cNRI (0.575) and IDI (0.085). A nomogram was then established based on the new model including sCysC and uNAG. Application of this nomogram in the validation cohort yielded fair discrimination with an AUC of 0.784 and good calibration. The DCA revealed good clinical utility of this nomogram. CONCLUSIONS: A nomogram that incorporates functional marker (sCysC) and tubular damage marker (uNAG), together with routine clinical factors may be a useful prognostic tool for individualized prediction of AKI in septic patients.


Assuntos
Acetilglucosaminidase/urina , Injúria Renal Aguda/etiologia , Biomarcadores/análise , Cistatina C/sangue , Nomogramas , Sepse/complicações , Idoso , Área Sob a Curva , Técnicas de Apoio para a Decisão , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Risco
15.
Sci Adv ; 7(7)2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33568482

RESUMO

Accurate, real-time monitoring of intravascular oxygen levels is important in tracking the cardiopulmonary health of patients after cardiothoracic surgery. Existing technologies use intravascular placement of glass fiber-optic catheters that pose risks of blood vessel damage, thrombosis, and infection. In addition, physical tethers to power supply systems and data acquisition hardware limit freedom of movement and add clutter to the intensive care unit. This report introduces a wireless, miniaturized, implantable optoelectronic catheter system incorporating optical components on the probe, encapsulated by soft biocompatible materials, as alternative technology that avoids these disadvantages. The absence of physical tethers and the flexible, biocompatible construction of the probe represent key defining features, resulting in a high-performance, patient-friendly implantable oximeter that can monitor localized tissue oxygenation, heart rate, and respiratory activity with wireless, real-time, continuous operation. In vitro and in vivo testing shows that this platform offers measurement accuracy and precision equivalent to those of existing clinical standards.

16.
Semin Immunopathol ; 43(1): 29-43, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33449155

RESUMO

The thymus is the primary organ for T-cell development, providing an essential microenvironment consisting of the appropriate cytokine milieu and specialized stromal cells. Thymus-seeding progenitors from circulation immigrate into the thymus and undergo the stepwise T-cell specification, commitment, and selection processes. The transcriptional factors, epigenetic regulators, and signaling pathways involved in the T-cell development have been intensively studied using mouse models. Despite our growing knowledge of T-cell development, major questions remain unanswered regarding the ontogeny and early events of T-cell development at the fetal stage, especially in humans. The recently developed single-cell RNA-sequencing technique provides an ideal tool to investigate the heterogeneity of T-cell precursors and the molecular mechanisms underlying the divergent fates of certain T-cell precursors at the single-cell level. In this review, we aim to summarize the current progress of the study on human thymus organogenesis and thymocyte and thymic epithelial cell development, which is to shed new lights on developing novel strategies for in vitro T-cell regeneration and thymus rejuvenation.


Assuntos
Células Estromais , Timócitos , Diferenciação Celular , Células Epiteliais , Humanos , RNA , Timo
18.
J Transl Int Med ; 9(4): 273-284, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35136726

RESUMO

BACKGROUND: Systematic estimation of renal biomarkers in the intensive care unit (ICU) patients is lacking. Seventeen biomarkers were assessed to predict acute kidney injury (AKI) after admission to ICU. MATERIALS AND METHODS: A prospective, observational study was conducted in the general ICU of Guangdong Provincial People's Hospital. Seventeen serum or urine biomarkers were studied for their abilities alone or in combination for predicting AKI and severe AKI. RESULTS: Of 1498 patients, 376 (25.1%) developed AKI. Serum cystatin C (CysC) showed the best performance for predicting both AKI (area under the receiver operator characteristic curve [AUC] = 0.785, mean square error [MSE] = 0.118) and severe AKI (AUC = 0.883, MSE = 0.06). Regarding biomarkers combinations, CysC plus N-acetyl-ß-d-glucosaminidase-to-creatinine ratio (NAG/Cr) was the best for predicting AKI (AUC = 0.856, MSE = 0.21). At the same time, CysC plus lactic acid (LAC) performed the best for predicting severe AKI (AUC = 0.907, MSE = 0.058). Regarding combinations of biomarkers and clinical markers, CysC plus Acute Physiology and Chronic Health Evaluation (APACHE) II score showed the best performance for predicting AKI (AUC = 0.868, MSE = 0.407). In contrast, CysC plus Multiple Organ Dysfunction Score (MODS) had the highest predictive ability for severe AKI (AUC = 0.912, MSE = 0.488). CONCLUSION: Apart from CysC, the combination of most clinically available biomarkers or clinical markers does not significantly improve the forecasting ability, and the cost-benefit ratio is not economical.

19.
Adv Healthc Mater ; 10(4): e2000722, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32989913

RESUMO

Eccrine sweat contains a rich blend of electrolytes, metabolites, proteins, metal ions, and other biomarkers. Changes in the concentrations of these chemical species can indicate alterations in hydration status and they can also reflect health conditions such as cystic fibrosis, schizophrenia, and depression. Recent advances in soft, skin-interfaced microfluidic systems enable real-time measurement of local sweat loss and sweat biomarker concentrations, with a wide range of applications in healthcare. Uses in certain contexts involve, however, physical impacts on the body that can dynamically deform these platforms, with adverse effects on measurement reliability. The work presented here overcomes this limitation through the use of microfluidic structures constructed in relatively high modulus polymers, and designed in geometries that offer soft, system level mechanics when embedded low modulus elastomers. Analytical models and finite element analysis quantitatively define the relevant mechanics of these systems, and serve as the basis for layouts optimized to allow robust operation in demanding, rugged scenarios such as those encountered in football, while preserving mechanical stretchability for comfortable, water-tight bonding to the skin. Benchtop testing and on-body field studies of measurements of sweat loss and chloride concentration under imposed mechanical stresses and impacts demonstrate the key features of these platforms.


Assuntos
Microfluídica , Suor , Eletrólitos , Reprodutibilidade dos Testes , Pele
20.
IEEE Trans Biomed Eng ; 68(4): 1389-1398, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33079653

RESUMO

OBJECTIVE: High-density surface electromyography (HD-sEMG) has been utilized extensively in neuromuscular research. Despite its potential advantages, limitations in electrode design have largely prevented widespread acceptance of the technology. Commercial electrodes have limited spatial fidelity, because of a lack of sharpness of the signal, and variable signal stability. We demonstrate here a novel tattoo electrode that addresses these issues. Our dry HD electrode grid exhibits remarkable deformability which ensures superior conformity with the skin surface, while faithfully recording signals during different levels of muscle contraction. METHOD: We fabricated a 4 cm×3 cm tattoo HD electrode grid on a stretchable electronics membrane for sEMG applications. The grid was placed on the skin overlying the biceps brachii of healthy subjects, and was used to record signals for several hours while tracking different isometric contractions. RESULTS: The sEMG signals were recorded successfully from all 64 electrodes across the grid. These electrodes were able to faithfully record sEMG signals during repeated contractions while maintaining a stable baseline at rest. During voluntary contractions, broad EMG frequency content was preserved, with accurate reproduction of the EMG spectrum across the full signal bandwidth. CONCLUSION: The tattoo grid electrode can potentially be used for recording high-density sEMG from skin overlying major limb muscles. Layout programmability, good signal quality, excellent baseline stability, and easy wearability make this electrode a potentially valuable component of future HD electrode grid applications. SIGNIFICANCE: The tattoo electrode can facilitate high fidelity recording in clinical applications such as tracking the evolution and time-course of challenging neuromuscular degenerative disorders.


Assuntos
Tatuagem , Dispositivos Eletrônicos Vestíveis , Eletrodos , Eletromiografia , Humanos , Contração Isométrica , Músculo Esquelético
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...