Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Childs Nerv Syst ; 29(10): 1811-25, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23832074

RESUMO

INTRODUCTION: Hydrocephalus is still a not well-understood diagnostic and a therapeutic dilemma because of the lack of sufficient and comprehensive model of cerebrospinal fluid circulation and pathological alterations. CONCLUSIONS: Based on current studies, reviews, and knowledge of cerebrospinal fluid dynamics, brain water dynamics, intracranial pressure, and cerebral perfusion physiology, a new concept is deducted that can describe normal and pathological changes of cerebrospinal fluid circulation and pathophysiology of idiopathic intracranial hypertension.


Assuntos
Encéfalo/fisiologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Líquido Cefalorraquidiano/fisiologia , Hidrocefalia/fisiopatologia , Humanos , Fluxo Pulsátil/fisiologia
2.
Acta Neurochir Suppl ; 114: 165-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22327685

RESUMO

We investigated two commercially available probes for measurement of the partial pressure of brain tissue oxygen (PbrO2) and calculation of the index of brain tissue oxygen pressure reactivity (ORx) in 7 patients after aneurysmal subarachnoid hemorrhage (SAH). Simultaneous monitoring of PbrO2 using the Licox(®) probe and the multiparameter Raumedic probe (Neurovent PTO(®)), measuring PbrO2, intracranial pressure (ICP) and brain temperature (Neurovent PTO) was performed for a median of 9 days (range 7-17 days). Both probes provided stable monitoring throughout the desired period. Mean PbrO2 from Licox and Neurovent PTO was 16.1 ± 9.0 mmHg and 17.5 ± 11.9 mmHg respectively. Mean ORx was 0.35 ± 0.44 and 0.31 ± 0.43 respectively. There was a difference in the measurement of PbrO2 of -2.73 ± 10.1 mmHg (Licox - Raumedic). The difference in the two values for the calculated ORx was far smaller (0.03 ± 0.31; Licox - Raumedic) and the correlation coefficient higher than for both values of PbrO2 (0.76 for ORx vs. 0.56 for PbrO2). The calculation of the autoregulation parameter ORx seemed more independent of the measurement process than the measurement of PbrO2 itself and signifies the potential clinical importance of this parameter.


Assuntos
Temperatura Corporal/fisiologia , Encéfalo/metabolismo , Oxigênio/análise , Pressão Parcial , Adulto , Idoso , Algoritmos , Lesões Encefálicas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador
3.
Int J Comput Assist Radiol Surg ; 4(5): 487-95, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20033532

RESUMO

PURPOSE: The aim of this work was the evaluation of a navigated and power controlled milling system for spine surgery (navigated control spine). The navigation is based on a set of intraoperatively taken fluoroscopic images from different angles. A manually planned workspace limits the power of the mill and assures a higher automatisation degree than any other established navigation system for spine surgery. METHODS: Both a technical study in workspace planning from fluoroscopic images and a milling study on a spine phantom were performed with participants with different level of knowledge of spinal surgery. RESULTS: In the region of interest the workspace planning could be performed with a maximum excess of 1.40 mm for surgeons. In the study performing the milling of a standardised workspace the remnant bone after milling had a mean difference from the planned workspace margin of 1.96-2.12 mm in the region of most interest. Accurate handling of the mill still required a certain level of medical knowledge and experience. In both studies the time needed for application of the system proved acceptable for clinical purposes. DISCUSSION: This concept of navigated and power controlled spinal surgery has proven feasible in an experimental study. This navigation system seems therefore promising for clinical application.


Assuntos
Vértebras Lombares/cirurgia , Procedimentos Ortopédicos/métodos , Cirurgia Assistida por Computador , Competência Clínica , Dura-Máter/lesões , Fluoroscopia , Humanos , Procedimentos Ortopédicos/efeitos adversos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...