Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
Pathology ; 54(1): 49-54, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34955242

RESUMO

Previous reports have shown that quantification of high tumour grade is of prognostic significance for patients with prostate cancer. In particular, percent Gleason pattern 4 (GP4) has been shown to predict outcome in several studies, although conflicting results have also been reported. A major issue with these studies is that they rely on surrogate markers of outcome rather than patient survival. We have investigated the prognostic predictive value of quantifying GP4 in a series of prostatic biopsies containing Gleason score 3+4=7 and 4+3=7 tumours. It was found that the length of GP4 tumour determined from the measurement of all biopsy cores from a single patient, percent GP4 present and absolute GP4 were all significantly associated with distant progression of tumour, all-cause mortality and cancer-specific mortality over a 10-year follow-up period. Assessment of the relative prognostic significance showed that these parameters outperformed division of cases according to Gleason score (3+4=7 versus 4+3=7). International Society of Urological Pathology (ISUP) Grade Groups currently divide these tumours, according to Gleason grading guidelines, into grade 2 (3+4=7) and grade 3 (4+3=7). Our results indicate that this simple classification results in the loss of important prognostic information. In view of this we would recommend that ISUP Grade Groups 2 and 3 be amalgamated as grade 2 tumour with the percentage of GP4 carcinoma being appended to the final grade, e.g., 3+4=7 carcinoma with 40% pattern 4 tumour would be classified as ISUP Grade Group 2 (40%).


Assuntos
Adenocarcinoma/patologia , Prognóstico , Neoplasias da Próstata/patologia , Biópsia com Agulha de Grande Calibre , Humanos , Masculino , Gradação de Tumores/métodos , Próstata/patologia , Prostatectomia , Estudos Retrospectivos
2.
Anim Genet ; 51(1): 3-13, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31637754

RESUMO

Telomeres are genetically conserved nucleoprotein complexes located at the ends of chromosomes that preserve genomic stability. In large mammals, somatic cell telomeres shorten with age, owing to the end replication problem and lack of telomere-lengthening events (e.g. telomerase and ALT activity). Therefore, telomere length reflects cellular replicative reserve and mitotic potential. Environmental insults can accelerate telomere attrition in response to cell division and DNA damage. As such, telomere shortening is considered one of the major hallmarks of ageing. Much effort has been dedicated to understanding the environmental perturbations that accelerate telomere attrition and therapeutic strategies to preserve or extend telomeres. As telomere dynamics seem to reflect cumulative cellular stress, telomere length could serve as a biomarker of animal welfare. The assessment of telomere dynamics (i.e. rate of shortening) in conjunction with telomere-regulating genes and telomerase activity in racehorses could monitor long-term animal health, yet it could also provide some unique opportunities to address particular limitations with the use of other animal models in telomere research. Considering the ongoing efforts to optimise the health and welfare of equine athletes, the purpose of this review is to discuss the potential utility of assessing telomere length in Thoroughbred racehorses. A brief review of telomere biology in large and small mammals will be provided, followed by discussion on the biological implications of telomere length and environmental (e.g. lifestyle) factors that accelerate or attenuate telomere attrition. Finally, the utility of quantifying telomere dynamics in horses will be offered with directions for future research.


Assuntos
Cavalos/genética , Encurtamento do Telômero , Telômero/ultraestrutura , Animais , Instabilidade Genômica , Humanos
3.
Anim Genet ; 49(5): 452-456, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30051918

RESUMO

Thoroughbred racehorses possess superior cardiorespiratory fitness levels and are at the pinnacle of athletic performance compared to other breeds of horses. Although equine athletes have undergone years of artificial selection for racing performance, musculoskeletal injuries and illnesses are common and concerns relating to animal welfare have been proposed. Leukocyte telomere length is indicative of biological age, and accelerated telomere shortening occurs with excess physical and psychological stress. This study was designed to explore the association between leukocyte telomere length, biological factors (age, sex and coat colour), training status, winnings and race history parameters. Blood was collected from 146 Thoroughbred racehorses from around Geelong, Victoria, Australia. DNA was extracted from leukocytes; telomere length was measured using qPCR and analysed in context with traits obtained from the Racing Australia website. Age was inversely correlated with telomere length (r = -0.194, P = 0.019). The oldest horses (≥11 years) in the highest age quartile possessed shorter telomeres compared to younger horses in the first, second and third quartiles (≤2, 3-5 and 6-10 years respectively; P < 0.05). No statistically significant associations were observed between telomere length and biological factors, training status, winnings or race history parameters in age-adjusted analyses. The study findings suggest that Thoroughbred horses may undergo age-related telomere shortening similar to other mixed breeds and humans. Despite concerns from some quarters regarding the welfare of racehorses, there was a lack of accelerated biological ageing observed in the present study, as indicated by leukocyte telomere length.


Assuntos
Cavalos/classificação , Cavalos/genética , Leucócitos/citologia , Telômero/genética , Animais , Austrália , Feminino , Cavalos/fisiologia , Masculino , Condicionamento Físico Animal
4.
Acta Physiol (Oxf) ; 222(1)2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28371392

RESUMO

Epigenetics is the study of gene expression changes that occur in the absence of altered genotype. Current evidence indicates a role for environmentally induced alterations to epigenetic modifications leading to health and disease changes across multiple generations. This phenomenon is called intergenerational or transgenerational epigenetic inheritance of health or disease. Environmental insults, in the form of toxins, plastics and particular dietary interventions, perturb the epigenetic landscape and influence the health of F1 through to F4 generations in rodents. There is, however, the possibility that healthy lifestyles and environmental factors, such as exercise training, could lead to favourable, heritable epigenetic modifications that augment transcriptional programmes protective of disease, including metabolic dysfunction, heart disease and cancer. The health benefits conferred by regular physical exercise training are unquestionable, yet many of the molecular changes may have heritable health implications for future generations. Similar to other environmental factors, exercise modulates the epigenome of somatic cells and researchers are beginning to study exercise epigenetics in germ cells. The germ cell epigenetic modifications affected by exercise offer a molecular mechanism for the inheritance of health and disease risk. The aims of this review are to: (i) provide an update on the expanding field of exercise epigenetics; (ii) offer an overview of data on intergenerational/transgenerational epigenetic inheritance of disease by environmental insults; (iii) to discuss the potential of exercise-induced intergenerational inheritance of health and disease risk; and finally, outline potential mechanisms and avenues for future work on epigenetic inheritance through exercise.


Assuntos
Epigênese Genética/fisiologia , Exercício Físico/fisiologia , Interação Gene-Ambiente , Animais , Regulação da Expressão Gênica/fisiologia , Humanos
5.
Clin Transl Radiat Oncol ; 7: 62-70, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29594231

RESUMO

Traditionally rectal symptoms following pelvic/prostate radiotherapy are correlated to the dosimetry of the anorectum or a substructure of this. It has been suggested that the perirectal fat space (PRS) surrounding the rectum may also be relevant. This study considers the delineation and dosimetry of the PRS related to both rectal bleeding and control-related toxicity. Initially, a case-control cohort of 100 patients from the RADAR study were chosen based on presence/absence of rectal control-related toxicity. Automated contouring was developed to delineate the PRS. 79 of the 100 auto-segmentations were considered successful. Balanced case-control cohorts were defined from these cases. Atlas of Complication Incidence (ACI) were generated to relate the DVH of the PRS with specific rectal symptoms; rectal bleeding and control-related symptoms (LENT/SOM). ACI demonstrated that control-related symptoms were related to the dose distribution to the PRS which was confirmed with Wilcoxon rank sum test (p < 0.05). To the authors knowledge this is the first study implicating the dose distribution to the PRS to the incidence of control-related symptoms of rectal toxicity.

6.
Artigo em Inglês | MEDLINE | ID: mdl-28004451

RESUMO

To describe the prevalence, severity and nature of depression in a sample of prostate cancer (PCa) survivors 10 years after diagnosis and treatment, 146 Australian patients from the RADAR trial who received their diagnosis 10 years previously completed the Zung Self-rating Depression Scale and a background questionnaire. Prevalence rates for clinically significant depression and severe depression were higher than those reported for the non-PCa men of the same age in Australia. The most common subtype of depression was Anhedonia, followed by Cognitive depression. Change in eating habits was the most powerful depression symptom predicting Anhedonia. By providing the first detailed documentation of major depression prevalence in PCa survivors, plus describing the nature of that depression, these data suggest that there is an ongoing need to provide treatments for these men and that those treatments should be focussed upon loss of previously available sources of enjoyment.


Assuntos
Sobreviventes de Câncer/psicologia , Transtorno Depressivo/epidemiologia , Neoplasias da Próstata/psicologia , Idoso , Idoso de 80 Anos ou mais , Transtorno Depressivo/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência
7.
Eur Rev Med Pharmacol Sci ; 20(23): 5021-5031, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27981527

RESUMO

OBJECTIVE: Nonsteroidal anti-inflammatory drugs (NSAIDs) are assembled into two categories; cyclooxygenase (COX-1) sparing inhibitors of COX-2 and non-selective NSAIDs. Diclofenac (DICLO) is a non-selective NSAID that has been linked to serious side effects including gastric ulcers and renal injury. In this study, we examine the effect of poly(lactic-co-glycolic) acid nanoformulation on DICLO-associated adverse events and pharmacokinetics using a nanoparticle (NP) formulation previously developed in our laboratory. MATERIALS AND METHODS: Rats were administered a single dose of methylcellulose (VEH), blank NP, DICLO (10 mg/kg), or a DICLO-NP suspension equivalent to the DICLO dose. Urinary and blood parameters were measured at baseline and following treatment. Duodenal and gastric prostaglandin E2 (PGE2) and duodenal myeloperoxidase (MPO) were collected to assess inflammation at 24 hrs post-treatment. RESULTS: The mean percent change from baseline in sodium excretion rate (µmol/min/100 g body weight) differed significantly from VEH in the NP (p < 0.0001), DICLO (p < 0.0001), and DICLO-NP (p = 0.0001) groups. The differences among groups did not reach significance for plasma sodium or potassium concentrations, potassium excretion rate, gastric PGE2, or intestinal biomarker concentrations. Regarding renal histopathology, DICLO produced considerably more necrosis compared to VEH; while DICLO-NP did not elicit notable differences from VEH. CONCLUSIONS: Our results suggest that over the duration and dosage examined, DICLO-NP may reduce renal necrosis without influencing other side effects or drug characteristics.


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Diclofenaco/farmacocinética , Nefropatias/induzido quimicamente , Animais , Ciclo-Oxigenase 2 , Glicóis , Nanopartículas , Ratos
8.
Eur Rev Med Pharmacol Sci ; 20(22): 4818-4829, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27906418

RESUMO

OBJECTIVE: Celecoxib (CEL) is a nonsteroidal anti-inflammatory drug (NSAID) showing selective cycloxygenase-2 inhibition. While effective as a pain reducer, CEL exerts some negative influence on renal and gastrointestinal parameters. This study examined CEL pharmacodynamics and pharmacokinetics following drug reformulation as a poly(lactic-co-glycolic) acid nanoparticle (NP). MATERIALS AND METHODS: Rats were administered either vehicle (VEH) (methylcellulose solution), blank NP, 40 mg/kg CEL in methylcellulose, or an equivalent NP dose (CEL-NP). Plasma and urine (over 12 hrs) samples were collected prior to and post-treatment. The mean percent change from baseline of urine flow rate along with electrolyte concentrations in plasma and urine were assessed based on 100 g body weight. Using tissues collected 24 hrs post-treatment, gastrointestinal inflammation was estimated through duodenal and gastric prostaglandin E2 (PGE2) and duodenal myeloperoxidase (MPO) levels; while kidney tissue was examined for dilatation and necrosis. CEL concentration was assayed in renal tissue and plasma utilizing high-performance liquid chromatography. RESULTS: Although there were significant changes when comparing CEL and CEL-NP to VEH in plasma sodium concentration and potassium excretion rate, there was no significant variation between CEL and CEL-NP. There was a significant reduction of protective duodenal PGE2 in CEL compared to VEH (p = 0.0088) and CEL-NP (p = 0.02). In the CEL-NP formulation, t1/2, Cmax, AUC0-∞, and Vd/F increased significantly when compared to CEL. CONCLUSIONS: At the observed dosage and duration, CEL-NP may not affect CEL-associated electrolyte parameters in either plasma or urine; however, it does provide increased systemic exposure while potentially alleviating some gastrointestinal outcomes related to inflammation.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Anti-Inflamatórios não Esteroides/farmacocinética , Celecoxib/farmacologia , Celecoxib/farmacocinética , Animais , Glicóis , Poliésteres , Ratos
9.
Phys Med ; 32(12): 1690-1697, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27720692

RESUMO

AIM: To investigate late gastrointestinal toxicity in a large pooled population of prostate cancer patients treated with radical radiotherapy. Normal tissue complication probability models were developed for late stool frequency and late rectal pain. METHODS AND MATERIALS: Population included 1336 patients, 3-year minimum follow-up, treated with 66-80Gy. Toxicity was scored with LENT-SOMA-scale. Two toxicity endpoints were considered: grade ⩾2 rectal pain and mean grade (average score during follow-up) in stool frequency >1. DVHs of anorectum were reduced to equivalent uniform dose (EUD). The best-value of the volume parameter n was determined through numerical optimization. Association between EUD/clinical factors and the endpoints was investigated by logistic analyses. Likelihood, Brier-score and calibration were used to evaluate models. External calibration was also carried out. RESULTS: 4% of patients (45/1122) reported mean stool frequency grade >1; grade ⩾2 rectal pain was present in the TROG 03.04 RADAR population only (21/677, 3.1%): for this endpoint, the analysis was limited to this population. Analysis of DVHs highlighted the importance of mid-range doses (30-50Gy) for both endpoints. EUDs calculated with n=1 (OR=1.04) and n=0.35 (OR=1.06) were the most suitable dosimetric descriptors for stool frequency and rectal pain respectively. The final models included EUD and cardiovascular diseases (OR=1.78) for stool frequency and EUD and presence of acute gastrointestinal toxicity (OR=4.2) for rectal pain. CONCLUSION: Best predictors of stool frequency and rectal pain are consistent with findings previously reported for late faecal incontinence, indicating an important role in optimization of mid-range dose region to minimize these symptoms highly impacting the quality-of-life of long surviving patients.


Assuntos
Fezes , Modelos Estatísticos , Dor/etiologia , Neoplasias da Próstata/radioterapia , Radioterapia/efeitos adversos , Reto/efeitos da radiação , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Radiometria , Reto/fisiopatologia , Reprodutibilidade dos Testes
10.
Pathology ; 47(6): 520-5, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26325671

RESUMO

In 2014 a consensus conference convened by the International Society of Urological Pathology (ISUP) adopted amendments to the criteria for Gleason grading and scoring (GS) for prostatic adenocarcinoma. The meeting defined a modified grading system based on 5 grading categories (grade 1, GS 3+3; grade 2, GS 3+4; grade 3, GS 4+3; grade 4, GS 8; grade 5, GS 9-10). In this study we have evaluated the prognostic significance of ISUP grading in 496 patients enrolled in the TROG 03.04 RADAR Trial. There were 19 grade 1, 118 grade 2, 193 grade 3, 88 grade 4 and 79 grade 5 tumours in the series, with follow-up for a minimum of 6.5 years. On follow-up 76 patients experienced distant progression of disease, 171 prostate specific antigen (PSA) progression and 39 prostate cancer deaths. In contrast to the 2005 modified Gleason system (MGS), the hazards of the distant and PSA progression endpoints, relative to grade 2, were significantly greater for grades 3, 4 and 5 of the 2014 ISUP grading scheme. Comparison of predictive ability utilising Harrell's concordance index, showed 2014 ISUP grading to significantly out-perform 2005 MGS grading for each of the three clinical endpoints.


Assuntos
Adenocarcinoma/patologia , Gradação de Tumores , Neoplasias da Próstata/patologia , Adenocarcinoma/mortalidade , Adenocarcinoma/terapia , Adulto , Idoso , Antagonistas de Androgênios/administração & dosagem , Antineoplásicos/administração & dosagem , Biópsia com Agulha de Grande Calibre , Quimiorradioterapia/métodos , Conferências de Consenso como Assunto , Difosfonatos/administração & dosagem , Humanos , Imidazóis/administração & dosagem , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Gradação de Tumores/métodos , Gradação de Tumores/normas , Patologia Cirúrgica/normas , Modelos de Riscos Proporcionais , Neoplasias da Próstata/mortalidade , Neoplasias da Próstata/terapia , Sociedades Médicas , Urologia/normas , Ácido Zoledrônico
11.
Eur Rev Med Pharmacol Sci ; 19(17): 3318-25, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26400540

RESUMO

OBJECTIVE: Utilization of nonsteroidal anti-inflammatory drugs (NSAIDs), such as diclofenac, can produce gastrointestinal ulceration. Thus, cyclooxygenase-2-selective inhibitors, such as celecoxib, and protective agents (e.g. rebamipide) have been employed to alleviate harmful NSAID effects. This study sought to explore the influence of rebamipide on the hepatic outcomes following administration of two commonly prescribed NSAIDs. MATERIALS AND METHODS: Rats were given either vehicle or rebamipide (30 mg/kg) orally twice daily for two days, then on the third day respective groups were dosed with either vehicle, celecoxib (40 mg/kg), or diclofenac (10 mg/kg) in addition to a respective dose of vehicle or rebamipide. Livers were collected on day 4 following euthanasia. Hepatic tissue was examined via histopathology and assayed for oxidative stress and specific NSAID concentration. RESULTS: The liver sections were found to be free from structural changes. Oxidative stress biomarkers, reduced glutathione and malondialdehyde, were discovered to be unaltered among the groups tested. The hepatic NSAID concentrations were not significantly affected by the presence of rebamipide. CONCLUSIONS: The concomitant administration of rebamipide does not influence the hepatic condition of rats administered either celecoxib or diclofenac at the dosages and over the time course examined.


Assuntos
Alanina/análogos & derivados , Anti-Inflamatórios não Esteroides/uso terapêutico , Celecoxib/efeitos adversos , Inibidores de Ciclo-Oxigenase 2/efeitos adversos , Diclofenaco/efeitos adversos , Quinolonas/uso terapêutico , Alanina/administração & dosagem , Alanina/uso terapêutico , Animais , Anti-Inflamatórios não Esteroides/administração & dosagem , Masculino , Quinolonas/administração & dosagem , Ratos , Ratos Sprague-Dawley
12.
Phys Med Biol ; 59(13): N101-11, 2014 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-24921159

RESUMO

Dose constraints based on histograms provide a convenient and widely-used method for informing and guiding radiotherapy treatment planning. Methods of derivation of such constraints are often poorly described. Two non-parametric methods for derivation of constraints are described and investigated in the context of determination of dose-specific cut-points-values of the free parameter (e.g., percentage volume of the irradiated organ) which best reflect resulting changes in complication incidence. A method based on receiver operating characteristic (ROC) analysis and one based on a maximally-selected standardized rank sum are described and compared using rectal toxicity data from a prostate radiotherapy trial. Multiple test corrections are applied using a free step-down resampling algorithm, which accounts for the large number of tests undertaken to search for optimal cut-points and the inherent correlation between dose-histogram points. Both methods provide consistent significant cut-point values, with the rank sum method displaying some sensitivity to the underlying data. The ROC method is simple to implement and can utilize a complication atlas, though an advantage of the rank sum method is the ability to incorporate all complication grades without the need for grade dichotomization.


Assuntos
Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Seguimentos , Humanos , Curva ROC , Dosagem Radioterapêutica , Estatísticas não Paramétricas , Resultado do Tratamento
13.
Med Phys ; 38(9): 5167-75, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21978061

RESUMO

PURPOSE: To assess dose delivery accuracy to clinically significant points in a realistic patient geometry for two separate pelvic radiotherapy scenarios. METHODS: An inhomogeneous pelvic phantom was transported to 36 radiotherapy centers in Australia and New Zealand. The phantom was treated according to Phase III rectal and prostate trial protocols. Point dose measurements were made with thermoluminescent dosimeters (TLDs) and an ionisation chamber. Comprehensive site-demographic, treatment planning, and physical data were collected for correlation with measurement outcomes. RESULTS: Dose delivery to the prescription point for the rectal treatment was consistent with planned dose (mean difference between planned and measured dose - 0.1 ± 0.3% std err). Dose delivery in the region of the sacral hollow was consistently higher than planned (+1.2 ± 0.2%). For the prostate treatment, dose delivery to the prostate volume was consistent with planned doses (-0.49 ± 0.2%) and planned dose uniformity, though with a tendency to underdose the PTV at the prostate-rectal border. Measured out-of-field doses were significantly higher than planned. CONCLUSIONS: A phantom based on realistic anatomy and heterogeneity can be used to comprehensively assess the influence of multiple aspects of the radiotherapy treatment process on dose delivery. The ability to verify dose delivery for two trials with a single phantom was advantageous.


Assuntos
Ensaios Clínicos como Assunto , Estudos Multicêntricos como Assunto , Pelve/anatomia & histologia , Imagens de Fantasmas , Radiometria/instrumentação , Radioterapia/métodos , Análise de Variância , Humanos , Masculino , Pelve/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Doses de Radiação , Tomografia Computadorizada por Raios X
14.
Med Phys ; 38(10): 5330-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21992351

RESUMO

PURPOSE: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. METHODS: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. RESULTS: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a "patient" to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. CONCLUSIONS: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.


Assuntos
Pelve/patologia , Imagens de Fantasmas , Radiometria/métodos , Radioterapia/métodos , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Humanos , Masculino , Teste de Materiais , Modelos Anatômicos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Software
15.
Clin Biochem ; 44(2-3): 208-15, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20950596

RESUMO

OBJECTIVES: To examine altered amino acid homeostasis as a predisposing factor of fatigue in female radiotherapy breast cancer patients. DESIGN AND METHODS: Participants underwent breast-conserving surgery and adjuvant breast irradiation and were free from significant fatigue pre-radiotherapy. The Functional Assessment of Cancer Therapy fatigue subscale was used to assess fatigue pre- and post-radiotherapy. Blood biochemistry factors and urinary and plasma amino acid levels were measured. RESULTS: One third of 27 patients developed fatigue and were designated as the fatigued cohort. It was possible to differentiate between fatigued subjects pre- and post-radiotherapy based upon their urinary amino acid profiles. Univariate analysis supported altered amino acid homeostasis within the fatigued cohort. Urinary levels of histidine and alanine were increased pre-radiotherapy whilst threonine, methionine, alanine, serine, asparagine and glutamine levels were higher after 5weeks of radiotherapy for the fatigued cohort. CONCLUSIONS: Fatigue was accompanied by altered amino acid homeostasis with increased amino acid excretion suggestive of a catabolic response.


Assuntos
Neoplasias da Mama , Fadiga , Aminoácidos/sangue , Neoplasias da Mama/sangue , Homeostase , Humanos , Projetos Piloto
16.
J Med Imaging Radiat Oncol ; 53(1): 119-31, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19453538

RESUMO

The present paper describes the logistics of the 2004-2008 Australasian Level III Dosimetry Intercomparison. Dosimetric intercomparisons (or 'audits') can be used in radiotherapy to evaluate the accuracy and quality of radiation delivery. An intercomparison was undertaken in New Zealand and Australia to evaluate the feasibility and logistics of ongoing dosimetric intercomparisons that evaluate all steps in the radiotherapy treatment process, known as a 'Level III' intercomparison. The study commenced in 2002 with the establishment of a study team, definition of the study protocol, acquisition of appropriate equipment and recruitment of participating radiotherapy centres. Measurements were undertaken between October 2004 and March 2008, and included collation of data on time, costs and logistics of the study. Forty independent Australian and New Zealand radiotherapy centres agreed to participate. Measurement visits were made to 37 of these centres. Data is presented on the costs of the study and the level of support required. The study involved the participation of 16 staff at the study centre who invested over 4000 hours in the study, and of over 200 professionals at participating centres. Recommendations are provided for future phantom-based intercomparisons. It is hoped that the present paper will be of benefit to any centres or groups contemplating similar activities by identifying the processes involved in establishing the study, the potential hazards and pitfalls, and expected resource requirements.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Radioterapia (Especialidade)/organização & administração , Radiometria/normas , Radioterapia Conformacional/normas , Australásia , Estudos de Viabilidade , Relações Interinstitucionais , Dosagem Radioterapêutica , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Med Imaging Radiat Oncol ; 52(5): 511-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19032399

RESUMO

The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres and a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 11-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless implanted fiducial markers are available for treatment guidance.


Assuntos
Ossos Pélvicos/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Próteses e Implantes , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Radioterapia Assistida por Computador/instrumentação , Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Med Imaging Radiat Oncol ; 52(5): 517-24, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19032400

RESUMO

The aims of this study were to investigate whether intrafraction prostate motion can affect the accuracy of online prostate positioning using implanted fiducial markers and to determine the effect of prostate rotations on the accuracy of the software-predicted set-up correction shifts. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Orthogonal electronic portal images were acquired to determine couch shifts before treatment. Verification images were also acquired during treatment to assess whether intrafraction motion had occurred. A limitation of the online image registration software is that it does not allow for in-plane prostate rotations (evident on lateral portal images) when aligning marker positions. The accuracy of couch shifts was assessed by repeating the registration measurements with separate software that incorporates full in-plane prostate rotations. Additional treatment time required for online positioning was also measured. For the patient group, the overall postalignment systematic prostate errors were less than 1.5 mm (1 standard deviation) in all directions (range 0.2-3.9 mm). The random prostate errors ranged from 0.8 to 3.3 mm (1 standard deviation). One patient exhibited intrafraction prostate motion, resulting in a postalignment prostate set-up error of more than 10 mm for one fraction. In 14 of 35 fractions, the postalignment prostate set-up error was greater than 5 mm in the anterior-posterior direction for this patient. Maximum prostate rotations measured from the lateral images varied from 2 degrees to 20 degrees for the patients. The differences between set-up shifts determined by the online software without in-plane rotations to align markers, and with rotations applied, was less than 1 mm (root mean square), with a maximum difference of 4.1 mm. Intrafraction prostate motion was found to reduce the effectiveness of the online set-up for one of the patients. A larger study is required to determine the magnitude of this problem for the patient population. The inability in the current software to incorporate in-plane prostate rotations is a limitation that should not introduce large errors, provided that the treatment isocentre is positioned near the centre of the prostate.


Assuntos
Ossos Pélvicos/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Próteses e Implantes , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Radioterapia Assistida por Computador/instrumentação , Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Sistemas On-Line , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Australas Phys Eng Sci Med ; 31(4): 268-79, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19239053

RESUMO

This paper describes the process and results of a survey of linear accelerator outputs as part of an Australasian Level III Dosimetry Intercomparison. This study involved the measurement of accelerator output under reference conditions ('Level I') with a small-volume ionisation chamber in water for 47 beams at 36 radiotherapy centres using the IAEA TRS 398 dose-to-water protocol. The mean ratio of measured to locally-determined accelerator output was 1.003 +/- 0.009 (1 standard deviation) with a range from 0.981 to 1.024. No correlation could be found between output ratio and accelerator type or local output calibration protocol. The small-volume chamber used satisfied most requirements for the study though showed some variation in sensitivity via repeated cross-calibration with a chamber calibrated at a primary standards laboratory.


Assuntos
Análise de Falha de Equipamento/estatística & dados numéricos , Aceleradores de Partículas/estatística & dados numéricos , Aceleradores de Partículas/normas , Garantia da Qualidade dos Cuidados de Saúde , Radiometria/instrumentação , Radiometria/normas , Austrália , Nova Zelândia , Radiometria/estatística & dados numéricos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Raios X
20.
Australas Phys Eng Sci Med ; 29(4): 300-2, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17260583

RESUMO

Dose calculations in brachytherapy planning typically don't take into account inhomogeneities and the material of applicators. We evaluated the justification of the latter by investigating the dose delivered in 192-Ir interstitial implants employing plastic catheters and steel needles using miniature LiF:Mg,Cu,P thermoluminescence dosimeters (TLDs) which fit in the applicators. Within the uncertainty of the measurement (+/- 5%) no difference could be found in the dose distribution from 192Ir in steel needles or plastic catheters. Computerized treatment planning (Philips/ADAC Pinnacle) was in good agreement with the measured data.


Assuntos
Artefatos , Materiais Biocompatíveis/química , Braquiterapia/instrumentação , Fluoretos/efeitos da radiação , Radioisótopos de Irídio/análise , Radioisótopos de Irídio/uso terapêutico , Compostos de Lítio/efeitos da radiação , Dosimetria Termoluminescente/instrumentação , Materiais Biocompatíveis/efeitos da radiação , Braquiterapia/métodos , Cateterismo , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Miniaturização , Agulhas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...