Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258308

RESUMO

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Assuntos
Anti-Infecciosos , Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Antibacterianos/uso terapêutico , Fatores de Risco , Eletrônica , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
2.
Heart Rhythm O2 ; 4(10): 609-617, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37936670

RESUMO

Background: Mechanisms sustaining persistent atrial fibrillation (AF) remain unclear. Objectives: The study sought to evaluate both the clinical outcomes and response to ablation of potential drivers in patients with recurrent persistent AF recurrence following pulmonary vein isolation (PVI). Methods: A total of 100 patients with persistent AF of <2 years' duration underwent cryoballoon PVI (ECGI phenotyping of persistent AF based on driver burden and distribution to predict response to pulmonary vein isolation). Patients with documented recurrence of atrial arrhythmia within 12 months were recruited and underwent repeat PVI (if needed) followed by ablation of potential drivers (PDs) identified by electrocardiographic imaging (ECGI). PDs were defined as rotational activity >1.5 revolutions or focal activations. Cycle lengths were measured pre- and postablation. The primary outcome was freedom from atrial arrhythmia off antiarrhythmic drugs at 1 year as per guidelines. Results: Of 37 patients recruited, 26 had recurrent AF and underwent ECGI-guided ablation of PDs. An average of 6.4 ± 2.7 PDs were targeted per patient. The mean ablation time targeting PDs was 15.5 ± 6.9 minutes. An ablation response occurred in 20 patients (AF termination in 6, cycle length prolongation ≥10% in 14). At 1 year, 14 (54%) of 26 patients were free from arrhythmia, and 12 (46%) of 26 were off antiarrhythmic drugs. Considering the 96 patients who completed follow-up out of the original cohort of 100 patients undergoing cryoablation in this staged strategy, freedom from arrhythmia at 1 year following the last procedure was 72 (75%) of 96, or 70 (73%) of 96 off antiarrhythmic drugs. Conclusions: In patients with recurrent AF despite PVI, ECGI-guided ablation caused an acute response in a majority with reasonable long-term outcomes.

3.
Am J Cardiol ; 198: 79-87, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37210977

RESUMO

In this study, we aimed to examine the diagnostic yield of pericardial fluid biochemistry and cytology and their prognostic significance in patients with percutaneously drained pericardial effusions, with and without malignancy. This is a single-center, retrospective study of patients who underwent pericardiocentesis between 2010 and 2020. Data were extracted from electronic patient records, including procedural information, underlying diagnosis, and laboratory results. Patients were grouped into those with and without underlying malignancy. A Cox proportional hazards model was used to analyze the association of variables with mortality. The study included 179 patients; 50% had an underlying malignancy. There were no significant differences in pericardial fluid protein and lactate dehydrogenase between the 2 groups. Diagnostic yield from pericardial fluid analysis was greater in the malignant group (32% vs 11%, p = 0.002); 72% of newly diagnosed malignancies had positive fluid cytology. The 1-year survival was 86% and 33% in nonmalignant and malignant groups, respectively (p <0.001). Of 17 patients who died within the nonmalignant group, idiopathic effusions were the largest group (n = 6). In malignancy, lower pericardial fluid protein and higher serum C-reactive protein were associated with increased risk of mortality. In conclusion, pericardial fluid biochemistry has limited value in determining the etiology of pericardial effusions; fluid cytology is the most important diagnostic test. Mortality in malignant pericardial effusions may be associated with lower pericardial fluid protein levels and a higher serum C-reactive protein. Nonmalignant pericardial effusions do not have a benign prognosis and close follow-up is required.


Assuntos
Neoplasias , Derrame Pericárdico , Humanos , Pericardiocentese/métodos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/cirurgia , Derrame Pericárdico/etiologia , Líquido Pericárdico , Proteína C-Reativa , Estudos Retrospectivos , Neoplasias/complicações , Neoplasias/diagnóstico , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...