Magn Reson Med ; 61(6): 1326-35, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19319903

RESUMO

A T(2) magnetization-preparation (T(2) Prep) sequence is proposed that is insensitive to B(1) field variations and simultaneously provides fat suppression without any further increase in specific absorption rate (SAR). Increased B(1) inhomogeneity at higher magnetic field strength (B(0) > or = 3T) necessitates a preparation sequence that is less sensitive to B(1) variations. For the proposed technique, T(2) weighting in the image is achieved using a segmented B(1)-insensitive rotation (BIR-4) adiabatic pulse by inserting two equally long delays, one after the initial reverse adiabatic half passage (AHP), and the other before the final AHP segment of a BIR-4 pulse. This sequence yields T(2) weighting with both B(1) and B(0) insensitivity. To simultaneously suppress fat signal (at the cost of B(0) insensitivity), the second delay is prolonged so that fat accumulates additional phase due to its chemical shift. Numerical simulations as well as phantom and in vivo image acquisitions were performed to show the efficacy of the proposed technique.


Assuntos
Algoritmos , Química Encefálica , Encéfalo/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Ondas de Rádio
2.
Magn Reson Med ; 49(2): 258-63, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12541245

RESUMO

The aim of this work was to demonstrate the feasibility of MRI-guided coronary artery catheterization and intervention in a dog model. Experiments were performed on 10 healthy dogs. A 9F introducer sheath was placed through a right carotid artery cutdown. A prototype 0.014-inch coronary MRI guidewire, a prototype 7 French MRI-guiding catheter, and two flexible surface coils were connected to a GE 1.5 T CV/i scanner for simultaneous visualization of the guidewire, guiding catheter, and chest anatomy. Images were displayed in real time on an in-room monitor. A nongated, single-slice fast gradient-echo sequence was used to obtain real-time images of the catheters and background anatomy during the intervention. Fifteen selective catheterizations were attempted in the coronary arteries, and all were successful. Selective injection of diluted gadolinium into the MRI-guiding catheter provided dynamic 2D projection coronary angiography in all cases, confirming successful catheterization. Percutaneous transluminal coronary angioplasty (PTCA) was attempted after two catheterizations, and all attempts were successful. Inflation of the balloon angioplasty catheter was performed successfully in the left anterior and circumflex arteries. Our results indicate that coronary artery catheterization and intracoronary balloon angioplasty are feasible with MRI guidance only. MRI guidance may be used as an alternative to X-ray guidance in coronary artery interventions in the future.


Assuntos
Angioplastia Coronária com Balão , Cateterismo/métodos , Vasos Coronários , Imageamento por Ressonância Magnética , Animais , Meios de Contraste , Vasos Coronários/anatomia & histologia , Cães , Estudos de Viabilidade , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos