1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 5437-5440, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892356

RESUMO

OBJECTIVE: We investigate the effect of selective single parameter personalization on the performance of multi-parameter models for pulse arrival time (PAT) based blood pressure (BP) surrogates. METHODS: Our data set stems from 15 surgery patients, and we selected from each patient 5 segments of 30 min length each. We evaluate the root mean squared BP tracking error of the two models with and without single parameter personalization. We further compare the BP tracking performance to a surrogate-free sample-and-hold approach, e.g., as afforded by conventional non-invasive blood pressure (NIBP) oscillometry. RESULTS: Parameter personalization is key to realizing a tracking performance benefit of PAT-based BP surrogates. The highest tracking error reduction of about 3.7 mmHg with respect to a sample-and-hold approach was reached with a personalized model which is linear in the pulse wave velocity domain. It achieves an estimation error of 7.8 mmHg with respect to a continuously measured invasive reference.Clinical Relevance-We give a performance analysis of PAT-based BP surrogates which are personalized to a patient with a single NIBP spot measurement. We show for surgery patients that patient-specific personalization enables continuous beat-to-beat BP monitoring over 30 min intervals with a average root mean squared error of less than 8 mmHg.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Pressão Sanguínea , Frequência Cardíaca , Humanos , Monitorização Fisiológica
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2561-2564, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018529

RESUMO

OBJECTIVE: We investigate an optimized non-uniform sampling strategy for blood pressure time series from the operating room (OR). Our aim is to obtain an approximate bound on the achievable reconstruction fidelity given an average sampling rate constraint. METHODS: Our data set consists of 117 hours of recordings of continuous invasive blood pressure from 28 surgery patients. We evaluate the root mean squared error (RMSE) of the zero-order hold sampling reconstruction of the blood pressure time series. We quantitatively compare the errors achieved by uniform versus optimized non-uniform sample placements for several average sample rates, ranging from 2 to 24 measurements per hour. RESULTS: An optimized non-uniform measurement schedule can lead to approximately 50% reduction of reconstruction RMSE for systolic, mean, and diastolic blood pressure time series with respect to uniform sampling, while maintaining the same average sampling rate.


Assuntos
Determinação da Pressão Arterial , Salas Cirúrgicas , Pressão Sanguínea , Humanos , Manejo de Espécimes , Sístole
3.
Int J Hyg Environ Health ; 208(5): 373-81, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16217921

RESUMO

OBJECTIVE: To investigate the relation between indoor environmental risk factors and respiratory symptoms in 7-8-year-old children living in the Dutch-German borderland. METHODS: A nested case-control study was conducted among children participating in a large longitudinal study on respiratory health. Parents of all 781 children with respiratory complaints and an equal number of randomly selected controls were asked to complete a questionnaire, including questions on indoor environment. RESULTS: The parents of 1191 children (76.2%) participated. Past exposure to environmental (OR = 2.73, 95% CI 1.14-6.67) as well as in utero exposure (OR = 2.28, 95% CI 1.15-4.53) to tobacco smoke, use of an unvented geyser for water heating (OR = 3.01, 95% CI 1.21-7.56), long-term exposure to dampness (OR = 2.98, 95% CI 1.10-8.28) or pets (OR = 2.18, 95% CI 1.39-3.42) increased the risk of asthmatic symptoms in 7-8-year-old children. A middle or low socio-economic status also increased the risk of asthmatic symptoms. An inverse association with asthmatic symptoms was seen for wall-to-wall carpeting (OR = 0.57, 95% CI 0.33-0.95) and insulation measures (OR = 0.46, 95% CI 0.25-0.83). Except for the presence of an unvented geyser, these environmental risk factors also presented a risk for coughing symptoms in children. CONCLUSION: This study showed an increased risk of respiratory symptoms in children exposed to several indoor environmental risk factors.


Assuntos
Poluição do Ar em Ambientes Fechados , Asma/etiologia , Tosse/etiologia , Exposição Ambiental , Animais , Animais Domésticos , Asma/epidemiologia , Estudos de Casos e Controles , Criança , Tosse/epidemiologia , Feminino , Fungos , Alemanha , Calefação/efeitos adversos , Habitação , Humanos , Umidade , Masculino , Países Baixos , Razão de Chances , Gravidez , Efeitos Tardios da Exposição Pré-Natal , Fatores de Risco , Fatores Sexuais , Poluição por Fumaça de Tabaco/efeitos adversos
4.
Gesundheitswesen ; 63(3): 166-9, 2001 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-11329908

RESUMO

AIM OF THE STUDY: In Westelijke Mijnstreek (WM), Midden-Limburg (ML), both The Netherlands, and Kreis Heinsberg (HS), Germany, the relationship between quality of the indoor environment and respiratory symptoms in children was studied, finally resulting in proposals for prevention of respiratory symptoms in the three regions. This paper presents the results of the first part of the study, investigating prevalences of respiratory complaints. METHODS AND RESULTS: A brief questionnaire was used to document prevalences of respiratory complaints, physicians diagnoses and treatment in about 7,000 children 5-6 resp. 7-8 years of age from HS, ML and WM, in 1995 and 1997. Prevalences of respiratory symptoms differed slightly between the regions, but there were differences in physician-diagnosed asthma and bronchitis and treatment of the children. PERSPECTIVES: The brief questionnaire is a useful instrument to get an overview on respiratory symptoms. Since 1995, it is used by several German Municipal Health Services for Public Health Reports.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Inquéritos Epidemiológicos , Pneumopatias Obstrutivas/epidemiologia , Poluição do Ar em Ambientes Fechados/efeitos adversos , Criança , Pré-Escolar , Estudos Transversais , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Pneumopatias Obstrutivas/etiologia , Masculino , Países Baixos/epidemiologia , Fatores de Risco