1.
J Contemp Brachytherapy ; 12(2): 160-165, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32395140

RESUMO

PURPOSE: The aim of this study was to propose an index for evaluating dosimetric impact of inter-observer target delineation variability in brachytherapy. MATERIAL AND METHODS: The coverage with dosimetric concordance index (CDCI) is expressed as CDCIcommon and CDCIpair. The CDCIcommon is the mean coverage of target volume with common volume irradiated by prescription dose among all observers and represents the condition of worst target coverage. CDCIpair is the generalized form of CDCI, which is mean target coverage with common prescription volume obtained between all possible pairs of observers and represents more realistic coverage of target with dosimetric concordance. The index was used to evaluate the dosimetric impact of target delineation variability in optimized conformal plans on target volumes of five radiation oncologists for twenty patients of multi-catheter interstitial partial breast brachytherapy. RESULTS: The mean decline of 5.6 ±3.2% and 11.3 ±5.7% in CDCIpair and CDCIcommon, respectively, was observed comparing to coverage index (CI) of target volume in all patients due to inter-observer target variability. CDCIcommon and CDCIpair were found to have significant linear correlation (r = 0.964, p < 0.000). The difference between CDC and CI increased with the mean relative target volume among observers. Significant correlation (r = 0.962, p < 0.000) was also noted for the difference (Δ) in CDCIcommon and CDCIpair with CI of target volume. CONCLUSIONS: The recommended indices and difference between the dosimetric coverage of target volume (CI) with CDCI (ΔCDCI) can be used for evaluating dosimetric impact of the inter-observer target delineation variability.

2.
Radiother Oncol ; 129(1): 173-179, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30318170

RESUMO

PURPOSE: To investigate dosimetric impact of inter-observer variation in clinical target volume(CTV) delineation for patients undergoing interstitial partial breast brachytherapy. METHODS: Five radiation oncologists delineated CTV in twenty patients who underwent multi-catheter partial breast brachytherapy. Five treatment plans for each patient were graphically optimized for CTV of all observers and evaluated using coverage index(CI), external volume index(EI), overdose volume index(OI) and conformal index(COIN). In addition, volume enclosed by prescription isodose(V100), its spatial concordance(CIcommon), mean coverage of all CTVs with common volume of prescription dose(V100_common) and mean CTV coverage for all pairs of observer with common prescription volume of respective pairs(V100_pair) were also computed. RESULTS: The mean ±â€¯standard deviation(SD) of CI and COIN ranged from 0.756 ±â€¯0.076 to 0.840 ±â€¯0.070 and 0.591 ±â€¯0.090 to 0.673 ±â€¯0.06 respectively. When a plan made for CTV of individual observer was evaluated on CTV of all observers, the maximum variations(ρ < 0.05) in the mean CI,COIN,OI and EI were 10.6%,11.4%,10.6% and 72.7% respectively. The observed mean ±â€¯SD of V100, CIcommon of V100, CTV coverage with V100_common and V100_pair was 160.7 ±â€¯52.1, 0.70 ±â€¯0.09, 73.1 ±â€¯8.1% and 77.9 ±â€¯7.3% respectively. CONCLUSION: Inter-observer variation in delineation of CTV showed significant dosimetric impact with mean CTV coverage of 73.1% and 77.9% by common and paired prescription dose volume respectively among all observers.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Braquiterapia/instrumentação , Cateterismo , Catéteres , Feminino , Humanos , Variações Dependentes do Observador , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
3.
Brachytherapy ; 16(5): 1028-1034, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28600139

RESUMO

PURPOSE: To investigate the change of clinical target volume (CTV) and its dosimetric impact during the course of accelerated partial breast irradiation (APBI) using intraoperative multicatheter interstitial brachytherapy after open cavity surgery. METHODS AND MATERIALS: Twenty-two patients of APBI with intraoperative placement of catheters underwent computed tomography scans for the treatment planning before the first (CT1) and the last (CT2) treatment fraction. Delineation of lumpectomy cavity and CTV was done consistently on both CT data sets by one of the coauthors. Optimum plan (PCT1) was made on CT1. PCT1 was manually reproduced in CT2 which yielded plan PCT2. Plans were compared using coverage index (CI), dose homogeneity index (DHI), external volume index (EI), overdose volume index (OI) and conformal index (COIN). RESULTS: The mean ± SD volume of lumpectomy cavity and CTV was 78.5 ± 40.7 cm3, 156.4 ± 69.0 cm3 for PCT1, and 84.7 ± 50.1 cm3 (p = 0.11), 165.7 ± 82.8 cm3 (p = 0.15) for PCT2, respectively. CTV volume increase by ≥ 10% was observed in 9 cases however decrease of ≥10% was observed in 5 cases. Mean (SD) of absolute pairwise difference in CTV volume was found to be 13.2 (6.7) %. For cases with increase in CTV volume, significant (p < 0.05) decrease of 8.4%, 12.2%, and 5.5% was observed in CI, EI, and COIN of CTV respectively. However for cases with shrinkage of CTV, significant (p = 0.004) increase of 45% in EI was observed, whereas COIN reduced significantly (p = 0.001) by 13.5%. Overall 22 cases showed significant decrease of 5.8% and 8.1% in mean CI and COIN, respectively. CONCLUSIONS: The change of CTV during the course of APBI using intraoperative multicatheter interstitial brachytherapy after open cavity surgery was found patient specific and showed a significant impact on coverage and conformity.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Cuidados Intraoperatórios , Adulto , Braquiterapia/instrumentação , Neoplasias da Mama/diagnóstico por imagem , Catéteres , Feminino , Humanos , Mastectomia Segmentar , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X
4.
J Contemp Brachytherapy ; 9(2): 139-145, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28533802

RESUMO

PURPOSE: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. MATERIAL AND METHODS: Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CIcommon, and CIgen), average shift in the center of mass (COM), and ratio of maximum and minimum volumes (Vmax/Vmin) of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step) for each catheter, total reference air kerma (TRAK), volume enclosed by prescription isodose (V100%) among observers and its spatial concordance were analyzed. RESULTS: The mean ± SD CIcommon of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and Vmax/Vmin decrease significantly (p < 0.05), as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm), respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm). The mean ± SD CIcommon of V100% was 0.75 ± 0.11. The mean observed Vmax/Vmin of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56) and 1.11 (range, 1.03 to 1.35), respectively. CONCLUSIONS: Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric impact on irradiation of breast tissue volume with prescription dose.

5.
J Med Phys ; 42(1): 9-13, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28405102

RESUMO

Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be -1.3%, 1.9%, -0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data.

7.
Phys Med Biol ; 61(7): 2680-704, 2016 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-26976308

RESUMO

Cavity theory is fundamental to understanding and predicting dosimeter response. Conventional cavity theories have been shown to be consistent with one another by deriving the electron (+positron) and photon fluence spectra with the FLURZnrc user-code (EGSnrc Monte-Carlo system) in large volumes under quasi-CPE for photon beams of 1 MeV and 10 MeV in three materials (water, aluminium and copper) and then using these fluence spectra to evaluate and then inter-compare the Bragg-Gray, Spencer-Attix and 'large photon' 'cavity integrals'. The behaviour of the 'Spencer-Attix dose' (aka restricted cema), D S-A(▵), in a 1-MeV photon field in water has been investigated for a wide range of values of the cavity-size parameter ▵: D S-A(▵) decreases far below the Monte-Carlo dose (D MC) for ▵ greater than ≈ 30 keV due to secondary electrons with starting energies below ▵ not being 'counted'. We show that for a quasi-scatter-free geometry (D S-A(▵)/D MC) is closely equal to the proportion of energy transferred to Compton electrons with initial (kinetic) energies above ▵, derived from the Klein-Nishina (K-N) differential cross section. (D S-A(▵)/D MC) can be used to estimate the maximum size of a detector behaving as a Bragg-Gray cavity in a photon-irradiated medium as a function of photon-beam quality (under quasi CPE) e.g. a typical air-filled ion chamber is 'Bragg-Gray' at (monoenergetic) beam energies ⩾260 keV. Finally, by varying the density of a silicon cavity (of 2.26 mm diameter and 2.0 mm thickness) in water, the response of different cavity 'sizes' was simulated; the Monte-Carlo-derived ratio D w/D Si for 6 MV and 15 MV photons varied from very close to the Spencer-Attix value at 'gas' densities, agreed well with Burlin cavity theory as ρ increased, and approached large photon behaviour for ρ ≈ 10 g cm(-3). The estimate of ▵ for the Si cavity was improved by incorporating a Monte-Carlo-derived correction for electron 'detours'. Excellent agreement was obtained between the Burlin 'd' factor for the Si cavity and D S-A(▵)/D MC at different (detour-corrected) ▵, thereby suggesting a further application for the D S-A(▵)/D MC ratio.


Assuntos
Algoritmos , Elétrons , Imagens de Fantasmas , Fótons , Radiometria/instrumentação , Radiometria/métodos
8.
Phys Med ; 32(1): 208-12, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26470807

RESUMO

AIM: The present study was to investigate the use of MOSFET as an vivo dosimeter for the application of Ir-192 HDR brachytherapy treatments. MATERIAL AND METHODS: MOSFET was characterized for dose linearity in the range of 50-1000 cGy, depth dose dependence from 2 to 7 cm, angular dependence. Signal fading was checked for two weeks. RESULT AND DISCUSSION: Dose linearity was found to be within 2% in the dose range (50-1000 cGy). The response varied within 8.07% for detector-source distance of 2-7 cm. The response of MOSFET with the epoxy side facing the source (0 degree) is the highest and the lowest response was observed at 90 and 270 degrees. Signal was stable during the study period. CONCLUSION: The detector showed high dose linearity and insignificant fading. But due to angular and depth dependence, care should be taken and corrections must be applied for clinical dosimetry.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Radioisótopos de Irídio/química , Radiometria/métodos , Calibragem , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Temperatura
9.
Brachytherapy ; 14(6): 953-62, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26489919

RESUMO

PURPOSE: To compare the dose accumulation for bladder and rectum by deformable image registration (DIR) and direct addition (DA) of dose volume histogram parameters in magnetic resonance image-guided adaptive brachytherapy (IGABT). Two DIR algorithms, contour- and intensity-based, also have been analyzed. METHODS AND MATERIALS: Patients (n = 21) treated with IGABT for carcinoma cervix under the IntErnational study on MRI-guided BRachytherapy in locally Advanced CErvical cancer protocol were analyzed. Each patient underwent two HDR-BT applications, 1-week apart with two fractions of 7 Gy each delivered per application. For each application, magnetic resonance imaging, volume delineation, reconstruction, treatment planning (BT1 and BT2), and dose evaluation were carried out. BT1 and BT2 images were registered using an intensity-based DIR, followed by deformable dose accumulation (DDA), which was then compared with DA. To compare the intensity-based DIR to other DIR approaches, nine patients were further evaluated using an in-house contour-based DIR algorithm for bladder dose accumulation. RESULTS: Mean (±standard deviation; range) percentage variation between DA and DDA was found to be 2.4% (±3.3;-1.8, 11.5) and 5.2% (±5.1;-1.7, 16.5) for the rectum and bladder, respectively. The differences between the DA and DDA were found to be statistically significant for both rectum (p = 0.008) and bladder (p = 0.0003). Intensity-based DIR algorithm resulted in a larger mean deviation between DDA and DA as compared with contour-based DIR, although statistically insignificant (p = 0.32). The difference between DDA and DA was 2.4 ± 2.0% and 1.3 ± 1.2%, for intensity- and contour-based DIR, respectively. CONCLUSIONS: DA of dose volume histogram parameters provides a good estimate to the dose to the organs at risk; DIR based on image intensities may lead to systematic underestimation of dose due to implausible DIR.


Assuntos
Algoritmos , Braquiterapia , Órgãos em Risco , Doses de Radiação , Radioterapia Guiada por Imagem , Reto , Bexiga Urinária , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Dosagem Radioterapêutica , Incerteza
10.
Phys Med Biol ; 60(20): 8187-212, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26439724

RESUMO

In small photon fields ionisation chambers can exhibit large deviations from Bragg-Gray behaviour; the EGSnrc Monte Carlo (MC) code system has been employed to investigate this 'Bragg-Gray breakdown'. The total electron (+positron) fluence in small water and air cavities in a water phantom has been computed for a full linac beam model as well as for a point source spectrum for 6 MV and 15 MV qualities for field sizes from 0.25 × 0.25 cm(2) to 10 × 10 cm(2). A water-to-air perturbation factor has been derived as the ratio of total electron (+positron) fluence, integrated over all energies, in a tiny water volume to that in a 'PinPoint 3D-chamber-like' air cavity; for the 0.25 × 0.25 cm(2) field size the perturbation factors are 1.323 and 2.139 for 6 MV and 15 MV full linac geometries respectively. For the 15 MV full linac geometry for field sizes of 1 × 1 cm(2) and smaller not only the absolute magnitude but also the 'shape' of the total electron fluence spectrum in the air cavity is significantly different to that in the water 'cavity'. The physics of this 'Bragg-Gray breakdown' is fully explained, making reference to the Fano theorem. For the 15 MV full linac geometry in the 0.25 × 0.25 cm(2) field the directly computed MC dose ratio, water-to-air, differs by 5% from the product of the Spencer-Attix stopping-power ratio (SPR) and the perturbation factor; this 'difference' is explained by the difference in the shapes of the fluence spectra and is also formulated theoretically. We show that the dimensions of an air-cavity with a perturbation factor within 5% of unity would have to be impractically small in these highly non-equilibrium photon fields. In contrast the dose to water in a 0.25 × 0.25 cm(2) field derived by multiplying the dose in the single-crystal diamond dosimeter (SCDDo) by the Spencer-Attix ratio is within 2.9% of the dose computed directly in the water voxel for full linac geometry at both 6 and 15 MV, thereby demonstrating that this detector exhibits quasi Bragg-Gray behaviour over a wide range of field sizes and beam qualities.


Assuntos
Elétrons , Modelos Teóricos , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Fótons , Radiometria/instrumentação , Humanos , Método de Monte Carlo , Radiometria/métodos , Água/química
11.
Phys Med Biol ; 60(2): 501-19, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25548933

RESUMO

The relationships between D, K and Kcol are of fundamental importance in radiation dosimetry. These relationships are critically influenced by secondary electron transport, which makes Monte-Carlo (MC) simulation indispensable; we have used MC codes DOSRZnrc and FLURZnrc. Computations of the ratios D/K and D/Kcol in three materials (water, aluminum and copper) for large field sizes with energies from 50 keV to 25 MeV (including 6-15 MV) are presented. Beyond the depth of maximum dose D/K is almost always less than or equal to unity and D/Kcol greater than unity, and these ratios are virtually constant with increasing depth. The difference between K and Kcol increases with energy and with the atomic number of the irradiated materials. D/K in 'sub-equilibrium' small megavoltage photon fields decreases rapidly with decreasing field size. A simple analytical expression for X̅, the distance 'upstream' from a given voxel to the mean origin of the secondary electrons depositing their energy in this voxel, is proposed: X̅(emp) ≈ 0.5R(csda)(E̅(0)), where E̅(0) is the mean initial secondary electron energy. These X̅(emp) agree well with 'exact' MC-derived values for photon energies from 5-25 MeV for water and aluminum. An analytical expression for D/K is also presented and evaluated for 50 keV-25 MeV photons in the three materials, showing close agreement with the MC-derived values.


Assuntos
Alumínio/efeitos da radiação , Cobre/efeitos da radiação , Fótons , Alumínio/química , Cobre/química , Elétrons , Método de Monte Carlo , Radiometria , Água/química
12.
J Med Phys ; 40(4): 190-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26865754

RESUMO

To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D2cm was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity.

13.
J Med Phys ; 40(4): 233-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26865760

RESUMO

The adequacy of setup margins for various sites in patients treated with helical tomotherapy was investigated. A total of 102 patients were investigated. The breakdown of the patients were as follows: Twenty-five patients each in brain, head and neck (H and N), and pelvis, while 12 patients in lung and 15 in craniospinal irradiation (CSI). Patients were immobilized on the institutional protocol. Altogether 2686 megavoltage computed tomography images were analyzed with 672, 747, 622, 333, and 312 fractions, respectively, from brain, H and N, pelvis, lung, and CSI. Overall systematic and random errors were calculated in three translational and three rotational directions. Setup margins were evaluated using van Herk formula. The calculated margins were compared with the margins in the clinical use for various directions and sites. We found that the clinical isotropic margin of 3 mm was adequate for brain patients. However, in the longitudinal direction it was found to be out of margin by 0.7 mm. In H and N, the calculated margins were well within the isotropic margin of 5 mm which is in clinical use. In pelvis, the calculated margin was within the limits, 8.3 mm versus 10 mm only in longitudinal direction, however, in vertical and lateral directions the calculated margins were out of clinical margins 11 mm versus 10 mm, and 8.7 mm versus 7.0, mm respectively. In lung, all the calculated margins were well within the margins used clinically. In CSI, the variation was found in the middle spine in the longitudinal direction. The clinical margins used in our hospital are adequate enough for sites H and N, lung, and brain, however, for CSI and pelvis the margins were found to be out of clinical margins.

14.
Indian J Crit Care Med ; 18(9): 591-5, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25249743

RESUMO

BACKGROUND AND AIMS: With the expanding use of diagnostic and therapeutic radiological modalities in critically ill patients, doctors working in Intensive Care Units (ICUs) are increasingly exposed to ionizing radiation. This risk of radiation exposure occurs not only during bedside radiologic procedures, but also when ICU physicians accompany patients to radiology suites. The aim of this study was to quantify levels of radiation exposure among medical professionals working in the ICU. MATERIALS AND METHODS: The study was carried out prospectively over 6 months in the ICU of a tertiary-referral cancer hospital. Two teams consisting of 4 ICU resident doctors each were instructed to wear thermoluminescent dosimeters (TLDs) during their duty shifts. Standard radiation protection precautions were used throughout the study period. TLDs were also placed in selected areas of the ICU to measure the amount of scattered radiation. TLDs were analyzed at the end of every 3 months. RESULTS: The readings recorded on TLDs placed in the ICU were almost immeasurable. The mean value of residents' radiation exposure was 0.059 mSv, though the highest individual reading approached 0.1 mSv. The projected maximum yearly radiation exposure was 0.4 mSv. CONCLUSIONS: If standard radiation safety precautions are followed, the cumulative radiation exposure to ICU resident doctors is well within permissible limits and is not a cause of concern. However, with the increasing use of radiological procedures in the management of critically ill patients, there is a need to repeat such audits periodically to monitor radiation exposure.

15.
J Med Phys ; 39(1): 40-3, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24600171

RESUMO

The objective of this study was to investigate the dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiotherapy. The influence of titanium-mandibular plate with the screws on radiation dose was tested on four real bones from mandible with the metal and screws fixed. Radiochromic films were used for dosimetry. The bone and metal were inserted through the film at the center symmetrically. This was then placed in a small jig (7 cm × 7 cm × 10 cm) to hold the film vertically straight. The polymer granules (tissue-equivalent) were placed around the film for homogeneous scatter medium. The film was irradiated with 6 MV X-rays for 200 monitor units in Trilogy linear accelerator for 10 cm × 10 cm field size with source to axis distance of 100 cm at 5 cm. A single film was also irradiated without any bone and metal interface for reference data. The absolute dose and the vertical dose profile were measured from the film. There was 10% dose enhancement due to the backscatter radiation just adjacent to the metal-bone interface for all the materials. The extent of the backscatter effect was up to 4 mm. There is significant higher dose enhancement in the soft tissue/skin due to the backscatter radiation from the metallic components in the treatment region.

16.
Radiother Oncol ; 107(1): 58-62, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23453543

RESUMO

PURPOSE: Evaluation of Inter-application variation of doses and spatial location of D(2cm(3)) volumes of OARs during MR-image based cervix brachytherapy. MATERIALS AND METHODS: Twenty-seven patients treated with EMBRACE protocol were analyzed. Every patient had two applications, one week apart. For each application patient had undergone MR-imaging (MR-1 and MR-2), volume delineation, reconstruction, treatment planning (plan-1 and plan-2) and dose evaluation. Both the image series were then co-registered with applicator as the reference coordinate system (Eclipse planning system v8.6.14). Inter-application dose, volume and spatial location of D(2cm(3)) variation were evaluated. RESULTS: The largest inter-application systematic and random dose variations were observed for sigmoid as compared to rectum and bladder. The mean (±SD) of the relative D(2cm(3)) variations were 0.6(±15.1)%, 0.9(±13.1)% and 11.9(±37.5)% for rectum, bladder and sigmoid respectively. The overlap of D(2cm(3)) volumes was more than 50% in 16(59%), 8(30%) and 3(11%) patients for rectum, bladder and sigmoid, respectively. CONCLUSION: The 2cm(3) volumes between the applications/fractions are quite stable in topography for bladder and rectum, and hence the current practice of cumulative addition of D(2cm(3)) dose is expected to be valid for bladder and rectum. For sigmoid, significant topographical changes were seen, which need further validation in a larger patient population and in multi-centric settings.


Assuntos
Braquiterapia/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias do Colo do Útero/radioterapia , Colo Sigmoide/efeitos da radiação , Feminino , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Reto/efeitos da radiação , Bexiga Urinária/efeitos da radiação , Neoplasias do Colo do Útero/patologia
17.
Radiother Oncol ; 102(1): 130-4, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21885140

RESUMO

PURPOSE: Trans-abdominal ultrasonography (US) is capable of determining size, shape, thickness, and diameter of uterus, cervix and disease at cervix or parametria. To assess the potential value of US for image-guided cervical cancer brachytherapy, we compared US-findings relevant for brachytherapy to the corresponding findings obtained from MR imaging. MATERIALS AND METHODS: Twenty patients with biopsy proven cervical cancer undergoing definitive radiotherapy with/without concomitant Cisplatin chemotherapy and suitable for brachytherapy were invited to participate in this study. US and MR were performed in a similar reproducible patient positioning after intracavitary application. US mid-sagittal and axial image at the level of external cervical os was acquired. Reference points D1 to D9 and distances were identified with respect to central tandem and flange, to delineate cervix, central disease, and external surface of the uterus. RESULTS: Thirty-two applications using CT/MR compatible applicators were evaluable. The D1 and D3 reference distances which represent anterior surface had a strong correlation with R=0.92 and 0.94 (p<0.01). The D2 and D4 reference distances in contrast, which represent the posterior surface had a moderate (D2) and a strong (D4) correlation with R=0.63 and 0.82 (p<0.01). Of all, D2 reference distance showed the least correlation of MR and US. The D5 reference distance representing the fundal thickness from tandem tip had a correlation of 0.98. The reference distances for D6, D7, D8, and D9 had a correlation of 0.94, 0.82, 0.96, and 0.93, respectively. CONCLUSIONS: Our study evaluating the use of US, suggests a reasonably strong correlation with MR in delineating uterus, cervix, and central disease for 3D conformal intracavitary brachytherapy planning.


Assuntos
Braquiterapia/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Antineoplásicos/uso terapêutico , Cisplatino/uso terapêutico , Feminino , Humanos , Estadiamento de Neoplasias , Posicionamento do Paciente , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/patologia
18.
Int J Gynecol Cancer ; 21(6): 1110-6, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21633296

RESUMO

OBJECTIVE: The objectives are to report the dosimetric analysis, preliminary clinical outcome, and comparison with published data of 3-dimensional magnetic resonance-based high dose rate brachytherapy (BT) in cervical cancer. MATERIALS AND METHODS: The data set of 24 patients with cervical cancer treated with high dose-rate brachytherapy applications was analyzed. All patients received radiation with or without chemotherapy (10 patients received concomitant chemoradiation). Point A, International Commission on Radiation Units and Measurement (ICRU) point doses, and Groupe Europeen de Curietherapie-European Society for Therapeutic Radiology and Oncology dose volume parameters, namely, high-risk clinical target volume (HR-CTV), D90 and D100 doses, and dose to D0.1cc and D2cc, for rectum, bladder, and sigmoid, were calculated and correlated. RESULTS: Mean ± SD HR-CTV was 45.2 ± 15.8 cc. The mean ± SD point A dose was 73.4 ± 4.5 Gy (median, 74.3 Gy) total biologically equivalent dose in 2 Gy per fraction (EQD2), whereas mean ± SD D90 doses were 70.9 ± 10.6 GyEQD2 (median, 68). The mean ± SD ICRU rectal and bladder points were 63.5 ± 8.1 and 80.4 ± 34.4 GyEQD2, respectively. The D0.1cc and D2cc for rectum were 66.0 ± 9.9 GyEQD2 (median, 64.5) and 57.8 ± 7.7 GyEQD2 (median, 58.8), for bladder 139.1 ± 54.7 GyEQD2 (median, 131.9) and 93.4 ± 24.6 GyEQD2 (median, 91), and sigmoid were 109.4 ± 45.2 GyEQD2 (median, 91) and 74.6 ± 19.6 GyEQD2 (median, 69.6). With a median follow-up of 24 months, 3 patients had local nodal failure, 1 had right external iliac nodal failure, and 1 had left supraclavicular nodal failure. CONCLUSIONS: The 3-D magnetic resonance image-based high dose-rate brachytherapy approach in cervical cancers is feasible. In our experience, the HR-CTV volumes are large, and D0.1cc and D2cc doses to bladder and sigmoid are higher than published literature so far.


Assuntos
Neoplasias do Colo do Útero/radioterapia , Adenocarcinoma/mortalidade , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Adulto , Idoso , Braquiterapia , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Europa (Continente) , Feminino , Humanos , Índia , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Guias de Prática Clínica como Assunto , Dosagem Radioterapêutica , Reto/patologia , Análise de Sobrevida , Bexiga Urinária/patologia , Neoplasias do Colo do Útero/mortalidade , Neoplasias do Colo do Útero/patologia
19.
Brachytherapy ; 10(4): 306-12, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21030317

RESUMO

PURPOSE: To compare inverse planning simulated annealing (IPSA) algorithm with the dose-point optimized (DPO) plan and manual/graphically optimized (GrO) plan for interstitial template brachytherapy for gynecologic cancers. METHODS AND MATERIALS: The data set of 10 consecutive patients was selected for this dosimetric study. For each patient, three plans were calculated: DPO, GrO, and IPSA. Dose-volume parameters from the three plans were compared to analyze the dosimetric outcome. RESULTS: Coverage of the clinical target volume (CTV) with GrO plan and IPSA algorithm was significantly better (mean V(100) of 88.8% and 89.1%; p=0.006) as compared with DPO plan (83.7%; p=0.62). Similarly, mean D(90) was same in both GrO plan and IPSA, 3.96±0.23 and 3.96±0.15Gy, respectively. DPO plans were homogeneous with homogeneity index being 0.82 as compared with 0.68±0.05 of GrO plan and 0.71±0.04 of IPSA. However, IPSA resulted in high conformity with conformity index of 0.78 as compared with 0.72 (p=0.001) and 0.68 (p≤0.001) for GrO and DPO plans, respectively. The dose to rectum (3.3±1.06Gy) and bladder (3.17±0.5Gy) was generally high for DPO plan. GrO plan reduced the dose to the rectum (2.91±0.63; p=0.011) and bladder (2.89±0.63Gy; p=0.003) significantly. IPSA resulted in a further reduction of the dose to rectum (2.79±0.67Gy; p=0.046) and bladder (2.81±0.67Gy; p=0.035), however with no statistical significance as compared with GrO plan. CONCLUSION: IPSA resulted in significant sparing of normal tissues without compromising CTV coverage as compared with DPO plan. However, IPSA did not show any significant improvement either in CTV coverage or in normal tissue sparing as compared with GrO plan. IPSA was found to be superior in terms of homogeneity and conformity as compared with GrO plan.


Assuntos
Braquiterapia/instrumentação , Neoplasias dos Genitais Femininos/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Feminino , Seguimentos , Humanos , Dosagem Radioterapêutica , Resultado do Tratamento
20.
Radiother Oncol ; 97(3): 501-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20846734

RESUMO

PURPOSE: Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns. MATERIALS AND METHODS: Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized. Dosimetric outcomes from these plans were compared based on dose-volume parameters. The ratio of Total Reference Air Kerma of ovoid to tandem (TRAK(O/T)) was used to compare the loading patterns. RESULTS: The volume of HR CTV ranged from 9-68 cc with a mean of 41(±16.2) cc. Mean V100 for standard, manual optimized and inverse plans was found to be not significant (p=0.35, 0.38, 0.4). Dose to bladder (7.8±1.6 Gy) and sigmoid (5.6±1.4 Gy) was high for standard plans; Manual optimization reduced the dose to bladder (7.1±1.7 Gy p=0.006) and sigmoid (4.5±1.0 Gy p=0.005) without compromising the HR CTV coverage. The inverse plan resulted in a significant reduction to bladder dose (6.5±1.4 Gy, p=0.002). TRAK was found to be 0.49(±0.02), 0.44(±0.04) and 0.40(±0.04) cGy m(-2) for the standard loading, manual optimized and inverse plans, respectively. It was observed that TRAK(O/T) was 0.82(±0.05), 1.7(±1.04) and 1.41(±0.93) for standard loading, manual optimized and inverse plans, respectively, while this ratio was 1 for the traditional loading pattern. CONCLUSIONS: Inverse planning offers good sparing of critical structures without compromising the target coverage. The average loading pattern of the whole patient cohort deviates from the standard Fletcher loading pattern.


Assuntos
Algoritmos , Braquiterapia/métodos , Neoplasias do Colo do Útero/radioterapia , Colo Sigmoide/efeitos da radiação , Feminino , Humanos , Imageamento por Ressonância Magnética , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reto/efeitos da radiação , Carga Tumoral , Bexiga Urinária/efeitos da radiação , Neoplasias do Colo do Útero/patologia