Med Phys ; 49(4): e1-e49, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35032394

RESUMO

Modern fluoroscopes used for image guidance have become quite complex. Adding to this complexity are the many regulatory and accreditation requirements that must be fulfilled during acceptance testing of a new unit. Further, some of these acceptance tests have pass/fail criteria, whereas others do not, making acceptance testing a subjective and time-consuming task. The AAPM Task Group 272 Report spells out the details of tests that are required and gives visibility to some of the tests that while not yet required are recommended as good practice. The organization of the report begins with the most complicated fluoroscopes used in interventional radiology or cardiology and continues with general fluoroscopy and mobile C-arms. Finally, the appendices of the report provide useful information, an example report form and topics that needed their own section due to the level of detail.


Assuntos
Cardiologia , Radiologia Intervencionista , Fluoroscopia/métodos , Doses de Radiação , Radiologia Intervencionista/métodos , Relatório de Pesquisa
2.
Med Phys ; 42(1): 521-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25563290

RESUMO

PURPOSE: The authors describe a design for prepatient region of interest attenuators (ROIAs) to reduce dose area product (DAP) for clinical use. The authors describe a model to predict DAP values from x-ray technique parameters recorded during a clinical procedure for image sequences obtained in the presence or absence of ROIAs. The model was developed primarily to determine what the DAP to a patient undergoing cardiac catheterization with a ROIA would have been if no ROIA had been used allowing a determination of DAP reduction. METHODS: Copper ROIAs with thicknesses that vary gradually so as not to cause significant image artifacts were constructed. X-ray image sequences were acquired on a clinical catheterization system with and without ROIAs with varying x-ray technique parameters. DAP values were measured for all said exposures using an ionization chamber and compared to a model the authors developed. RESULTS: The model can predict DAP values within 3.5% on average with or without ROIAs when compared to ionization chamber measurements. CONCLUSIONS: The proposed experimental design is adequate for measuring DAP reductions on the order of 1.5-3.5 that are expected when introducing a ROIA during patient catheterization imaging.


Assuntos
Cateterismo Cardíaco/métodos , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/métodos , Artefatos , Fluoroscopia/métodos , Humanos , Modelos Teóricos , Doses de Radiação , Raios X