Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neurophotonics ; 6(2): 025003, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31037243

RESUMO

Blood vessel injury during image-guided brain biopsy poses a risk of hemorrhage. Approaches that reduce this risk may minimize related patient morbidity. We present here an intraoperative imaging device that has the potential to detect the brain vasculature in situ. The device uses multiple diffuse reflectance spectra acquired in an outward-viewing geometry to detect intravascular hemoglobin, enabling the construction of an optical image in the vicinity of the biopsy needle revealing the proximity to blood vessels. This optical detection system seamlessly integrates into a commercial biopsy system without disrupting the neurosurgical clinical workflow. Using diffusive brain tissue phantoms, we show that this device can detect 0.5-mm diameter absorptive carbon rods up to ∼ 2 mm from the biopsy window. We also demonstrate feasibility and practicality of the technique in a clinical environment to detect brain vasculature in an in vivo model system. In situ brain vascular detection may add a layer of safety to image-guided biopsies and minimize patient morbidity.

2.
J Biomed Opt ; 24(2): 1-10, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30767440

RESUMO

Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requirement of adjuvant treatment. Margin assessment is currently only performed by pathologists hours to days following surgery and the integration of a real-time surgical readout would benefit current prostatectomy procedures. Raman spectroscopy is a promising technology to assess surgical margins: its in vivo use during radical prostatectomy could help insure the extent of resected prostate and cancerous tissue is maximized. We thus present the design and development of a dual excitation Raman spectroscopy system (680- and 785-nm excitations) integrated to the robotic da Vinci surgical platform for in vivo use. Following validation in phantoms, spectroscopic data from 20 whole human prostates immediately following radical prostatectomy are obtained using the system. With this dataset, we are able to distinguish prostate from extra prostatic tissue with an accuracy, sensitivity, and specificity of 91%, 90.5%, and 96%, respectively. Finally, the integrated Raman spectroscopy system is used to collect preliminary spectroscopic data at the surgical margin in vivo in four patients.


Assuntos
Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Análise Espectral Raman/métodos , Sistemas Computacionais , Desenho de Equipamento , Humanos , Laparoscopia/métodos , Masculino , Recidiva Local de Neoplasia , Imagens de Fantasmas , Próstata/cirurgia , Prostatectomia/instrumentação , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Robóticos/instrumentação , Análise Espectral Raman/instrumentação
3.
J Biophotonics ; 12(3): e201800396, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30636032

RESUMO

Navigation-guided brain biopsies are the standard of care for diagnosis of several brain pathologies. However, imprecise targeting and tissue heterogeneity often hinder obtaining high-quality tissue samples, resulting in poor diagnostic yield. We report the development and first clinical testing of a navigation-guided fiberoptic Raman probe that allows surgeons to interrogate brain tissue in situ at the tip of the biopsy needle prior to tissue removal. The 900 µm diameter probe can detect high spectral quality Raman signals in both the fingerprint and high wavenumber spectral regions with minimal disruption to the neurosurgical workflow. The probe was tested in three brain tumor patients, and the acquired spectra in both normal brain and tumor tissue demonstrated the expected spectral features, indicating the quality of the data. As a proof-of-concept, we also demonstrate the consistency of the acquired Raman signal with different systems and experimental settings. Additional clinical development is planned to further evaluate the performance of the system and develop a statistical model for real-time tissue classification during the biopsy procedure.


Assuntos
Biópsia por Agulha/instrumentação , Encéfalo/patologia , Análise Espectral Raman/instrumentação , Desenho de Equipamento , Humanos
4.
BJU Int ; 122(2): 326-336, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29542855

RESUMO

OBJECTIVE: To test if Raman spectroscopy (RS) is an appropriate tool for the diagnosis and possibly grading of prostate cancer (PCa). PATIENTS AND METHODS: Between 20 and 50 Raman spectra were acquired from 32 fresh and non-processed post-prostatectomy specimens using a macroscopic handheld RS probe. Each measured area was characterized and categorized according to histopathological criteria: tissue type (extraprostatic or prostatic); tissue malignancy (benign or malignant); cancer grade (Grade Groups [GGs] 1-5); and tissue glandular level. The data were analysed using machine-learning classification with neural network. RESULTS: The RS technique was able to distinguish prostate from extraprostatic tissue with a sensitivity of 82% and a specificity of 83% and benign from malignant tissue with a sensitivity of 87% and a specificity of 86%. In an exploratory fashion, RS differentiated benign from GG1 in 726/801 spectra (91%; sensitivity 80%, specificity 91%), from GG2 in 588/805 spectra (73%; sensitivity 76%, specificity 73%), from GG3 in 670/797 spectra (84%; sensitivity 86%, specificity 84%), from GG4 in 711/802 spectra (88%; sensitivity 77%, specificity 89%) and from GG5 in 729/818 spectra (89%; sensitivity 90%, specificity 89%). CONCLUSION: Current diagnostic approaches of PCa using needle biopsies have suboptimal cancer detection rates and a significant risk of infection. Standard non-targeted random sampling results in false-negative biopsies in 15-30% of patients, which affects clinical management. RS, a non-destructive tissue interrogation technique providing vibrational molecular information, resolved the highly complex architecture of the prostate and detect cancer with high accuracy using a fibre optic probe to interrogate radical prostatectomy (RP) specimens from 32 patients (947 spectra). This proof-of-principle paves the way for the development of in vivo tumour targeting spectroscopy tools for informed biopsy collection to address the clinical need for accurate PCa diagnosis and possibly to improve surgical resection during RP as a complement to histopathological analysis.


Assuntos
Próstata/patologia , Neoplasias da Próstata/patologia , Análise Espectral Raman/métodos , Idoso , Tecnologia de Fibra Óptica , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Manejo de Espécimes , Análise Espectral Raman/instrumentação , Análise Espectral Raman/normas , Vibração
5.
Sci Rep ; 8(1): 1792, 2018 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-29379121

RESUMO

Modern cancer diagnosis requires histological, molecular, and genomic tumor analyses. Tumor sampling is often achieved using a targeted needle biopsy approach. Targeting errors and cancer heterogeneity causing inaccurate sampling are important limitations of this blind technique leading to non-diagnostic or poor quality samples, and the need for repeated biopsies pose elevated patient risk. An optical technology that can analyze the molecular nature of the tissue prior to harvesting could improve cancer targeting and mitigate patient risk. Here we report on the design, development, and validation of an in situ intraoperative, label-free, cancer detection system based on high wavenumber Raman spectroscopy. This optical detection device was engineered into a commercially available biopsy system allowing tumor analysis prior to tissue harvesting without disrupting workflow. Using a dual validation approach we show that high wavenumber Raman spectroscopy can detect human dense cancer with >60% cancer cells in situ during surgery with a sensitivity and specificity of 80% and 90%, respectively. We also demonstrate for the first time the use of this system in a swine brain biopsy model. These studies set the stage for the clinical translation of this optical molecular imaging method for high yield and safe targeted biopsy.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patologia , Análise Espectral Raman/métodos , Adulto , Idoso , Animais , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Suínos
6.
Biomed Opt Express ; 9(9): 4294-4305, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30615702

RESUMO

For prostate cancer (PCa) patients, radical prostatectomy (complete removal of the prostate) is the only curative surgical option. To date, there is no clinical technique allowing for real-time assessment of surgical margins to minimize the extent of residual cancer. Here, we present a tissue interrogation technique using a dual excitation wavelength Raman spectroscopy system capable of sequentially acquiring fingerprint (FP) and high wavenumber (HWN) Raman spectra. Results demonstrate the ability of the system to detect PCa in post-prostatectomy specimens. In total, 477 Raman spectra were collected from 18 human prostate slices. Each area measured with Raman spectroscopy was characterized as either normal or cancer based on histopathological analyses, and each spectrum was classified based on supervised learning using support vector machines (SVMs). Based on receiver operating characteristic (ROC) analysis, FP (area under the curve [AUC] = 0.89) had slightly superior cancer detection capabilities compared with HWN (AUC = 0.86). Optimal performance resulted from combining the spectral information from FP and HWN (AUC = 0.91), suggesting that the use of these two spectral regions may provide complementary molecular information for PCa detection. The use of leave-one-(spectrum)-out (LOO) or leave-one-patient-out (LOPO) cross-validation produced similar classification results when combining FP with HWN. Our findings suggest that the application of machine learning using multiple data points from the same patient does not result in biases necessarily impacting the reliability of the classification models.

7.
Cancer Res ; 77(14): 3942-3950, 2017 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-28659435

RESUMO

Effectiveness of surgery as a cancer treatment is reduced when all cancer cells are not detected during surgery, leading to recurrences that negatively impact survival. To maximize cancer cell detection during cancer surgery, we designed an in situ intraoperative, label-free, optical cancer detection system that combines intrinsic fluorescence spectroscopy, diffuse reflectance spectroscopy, and Raman spectroscopy. Using this multimodal optical cancer detection system, we found that brain, lung, colon, and skin cancers could be detected in situ during surgery with an accuracy, sensitivity, and specificity of 97%, 100%, and 93%, respectively. This highly sensitive optical molecular imaging approach can profoundly impact a wide range of surgical and noninvasive interventional oncology procedures by improving cancer detection capabilities, thereby reducing cancer burden and improving survival and quality of life. Cancer Res; 77(14); 3942-50. ©2017 AACR.


Assuntos
Carcinoma in Situ/diagnóstico por imagem , Carcinoma in Situ/cirurgia , Monitorização Intraoperatória/métodos , Imagem Óptica/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Neoplasias do Colo/diagnóstico , Neoplasias do Colo/patologia , Neoplasias do Colo/cirurgia , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Monitorização Intraoperatória/instrumentação , Imagem Óptica/instrumentação , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/cirurgia , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Análise Espectral Raman/instrumentação , Análise Espectral Raman/métodos
8.
Analyst ; 142(8): 1185-1191, 2017 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-27845785

RESUMO

Ambient light artifacts can confound Raman spectroscopy measurements performed in a clinical setting such as during open surgery. However, requiring light sources to be turned off during intraoperative spectral acquisition can be impractical because it can slow down the procedure by requiring surgeons to acquire data under light conditions different from the routine clinical practice. Here a filter system is introduced allowing in vivo Raman spectroscopy measurements to be performed with the light source of a neurosurgical microscope turned on, without interfering with the standard procedure. Ex vivo and in vivo results on calf and human brain, respectively, show that when the new filter system is used there is no significant difference between Raman spectra acquired under pitch dark conditions or with the microscope light source turned on. This is important for the clinical translation of Raman spectroscopy because of the resulting decrease in total imaging time for each measurement and because the surgeon can now acquire spectroscopic data with no disruption of the surgical workflow.


Assuntos
Confiabilidade dos Dados , Microcirurgia , Análise Espectral Raman , Artefatos , Humanos , Iluminação
9.
Biomed Opt Express ; 7(12): 5129-5137, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28018730

RESUMO

Surgical treatment of brain cancer is limited by the inability of current imaging capabilities such as magnetic resonance imaging (MRI) to detect the entirety of this locally invasive cancer. This results in residual cancer cells remaining following surgery, leading to recurrence and death. We demonstrate that intraoperative Raman spectroscopy can detect invasive cancer cells centimeters beyond pathological T1-contrast-enhanced and T2-weighted MRI signals. This intraoperative optical guide can be used to detect invasive cancer cells and minimize post-surgical cancer burden. The detection of distant invasive cancer cells beyond MRI signal has the potential to increase the effectiveness of surgery and directly lengthen patient survival.

10.
Phys Med Biol ; 61(23): R370-R400, 2016 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-27804917

RESUMO

There is an urgent need for improved techniques for disease detection. Optical spectroscopy and imaging technologies have potential for non- or minimally-invasive use in a wide range of clinical applications. The focus here, in vivo Raman spectroscopy (RS), measures inelastic light scattering based on interaction with the vibrational and rotational modes of common molecular bonds in cells and tissue. The Raman 'signature' can be used to assess physiological status and can also be altered by disease. This information can supplement existing diagnostic (e.g. radiological imaging) techniques for disease screening and diagnosis, in interventional guidance for identifying disease margins, and in monitoring treatment responses. Using fiberoptic-based light delivery and collection, RS is most easily performed on accessible tissue surfaces, either on the skin, in hollow organs or intra-operatively. The strength of RS lies in the high biochemical information content of the spectra, that characteristically show an array of very narrow peaks associated with specific chemical bonds. This results in high sensitivity and specificity, for example to distinguish malignant or premalignant from normal tissues. A critical issue is that the Raman signal is often very weak, limiting clinical use to point-by-point measurements. However, non-linear techniques using pulsed-laser sources have been developed to enable in vivo Raman imaging. Changes in Raman spectra with disease are often subtle and spectrally distributed, requiring full spectral scanning, together with the use of tissue classification algorithms that must be trained on large numbers of independent measurements. Recent advances in instrumentation and spectral analysis have substantially improved the clinical feasibility of RS, so that it is now being investigated with increased success in a wide range of cancer types and locations, as well as for non-oncological conditions. This review covers recent advances and continuing challenges, with emphasis on clinical translation.


Assuntos
Imagem Molecular/métodos , Neoplasias/diagnóstico , Análise Espectral Raman/métodos , Humanos , Imagem Molecular/instrumentação
12.
Biomed Opt Express ; 6(7): 2380-97, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26203368

RESUMO

A detailed characterization study is presented of a Raman spectroscopy system designed to maximize the volume of resected cancer tissue in glioma surgery based on in vivo molecular tissue characterization. It consists of a hand-held probe system measuring spectrally resolved inelastically scattered light interacting with tissue, designed and optimized for in vivo measurements. Factors such as linearity of the signal with integration time and laser power, and their impact on signal to noise ratio, are studied leading to optimal data acquisition parameters. The impact of ambient light sources in the operating room is assessed and recommendations made for optimal operating conditions. In vivo Raman spectra of normal brain, cancer and necrotic tissue were measured in 10 patients, demonstrating that real-time inelastic scattering measurements can distinguish necrosis from vital tissue (including tumor and normal brain tissue) with an accuracy of 87%, a sensitivity of 84% and a specificity of 89%.

13.
Sci Transl Med ; 7(274): 274ra19, 2015 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-25673764

RESUMO

Cancers are often impossible to visually distinguish from normal tissue. This is critical for brain cancer where residual invasive cancer cells frequently remain after surgery, leading to disease recurrence and a negative impact on overall survival. No preoperative or intraoperative technology exists to identify all cancer cells that have invaded normal brain. To address this problem, we developed a handheld contact Raman spectroscopy probe technique for live, local detection of cancer cells in the human brain. Using this probe intraoperatively, we were able to accurately differentiate normal brain from dense cancer and normal brain invaded by cancer cells, with a sensitivity of 93% and a specificity of 91%. This Raman-based probe enabled detection of the previously undetectable diffusely invasive brain cancer cells at cellular resolution in patients with grade 2 to 4 gliomas. This intraoperative technology may therefore be able to classify cell populations in real time, making it an ideal guide for surgical resection and decision-making.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/cirurgia , Análise Espectral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
14.
Med Phys ; 37(4): 1565-70, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443477

RESUMO

PURPOSE: The purpose of this study is to determine the effect on the measured optical density of scanning on either side of a Gafchromic EBT and EBT2 film using an Epson (Epson Canada Ltd., Toronto, Ontario) 10000XL flat bed scanner. METHODS: Calibration curves were constructed using EBT2 film scanned in landscape orientation in both reflection and transmission mode on an Epson 10000XL scanner. Calibration curves were also constructed using EBT film. Potential errors due to an optical density difference from scanning the film on either side ("face up" or "face down") were simulated. RESULTS: Scanning the film face up or face down on the scanner bed while keeping the film angular orientation constant affects the measured optical density when scanning in reflection mode. In contrast, no statistically significant effect was seen when scanning in transmission mode. This effect can significantly affect relative and absolute dose measurements. As an application example, the authors demonstrate potential errors of 17.8% by inverting the film scanning side on the gamma index for 3%-3 mm criteria on a head and neck intensity modulated radiotherapy plan, and errors in absolute dose measurements ranging from 10% to 35% between 2 and 5 Gy. CONCLUSIONS: Process consistency is the key to obtaining accurate and precise results in Gafchromic film dosimetry. When scanning in reflection mode, care must be taken to place the film consistently on the same side on the scanner bed.


Assuntos
Dosimetria Fotográfica/métodos , Radiometria/métodos , Calibragem , Simulação por Computador , Relação Dose-Resposta à Radiação , Análise de Falha de Equipamento/métodos , Humanos , Óptica e Fotônica , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...