Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Methods Programs Biomed ; 247: 108083, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38402715

RESUMO

BACKGROUND: This study is undertaken to establish the accuracy and reliability of OrthoCalc, a 3D application designed for the evaluation of maxillary positioning. METHODS: We registered target virtual planned models, maxillary models from pre-operative and post-operative CT scans, and post-operative intra-oral scans to a common reference system, allowing for digital evaluation. To assess rotational changes, we introduced a novel measurement method based on virtual cuboid models. Displacement errors were calculated based on proposed registration matrices. We also compared OrthoCalc to established commercial medical software as a benchmark. RESULTS: Statistical significance calculated showed no significant differences between OrthoCalc and commercial software. the biggest error of 0.04 degree in rotation change was found in the yaw. A maximum displacement change of 0.75 mm was found in the X direction. CONCLUSIONS: Our study validates OrthoCalc as a precise and reliable tool for assessing maxillary position changes with six degrees of freedom in orthognathic surgery, endorsing its clinical utility.


Assuntos
Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Procedimentos Cirúrgicos Ortognáticos/métodos , Maxila/diagnóstico por imagem , Reprodutibilidade dos Testes , Fluxo de Trabalho , Software , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos
2.
Bone Res ; 2: 14010, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26273522

RESUMO

Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 µm) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (∼6 µm) to obtain high contrast 2D images. By using CTAn imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb.Th and Tb.Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...