Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
G Ital Cardiol (Rome) ; 23(6): 461-468, 2022 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-35674037

RESUMO

BACKGROUND: To assess the longitudinal changes in transcatheter aortic valve implantation (TAVI) practice and patients' outcomes in a high-volume Italian center. METHODS: We analyzed all patients undergoing TAVI at our Institution from June 2007 to August 2021. We stratified the overall population considering four time periods according to procedural advancements and changes in clinical practice: period 1 (2007-2009, n=107) vs period 2 (2010-2014, n=449) vs period 3 (2015-2019, n=864) vs period 4 (2019-2021, n=638). Baseline and procedural characteristics, and in-hospital outcomes among the four groups were compared. RESULTS: A total of 2058 patients underwent TAVI receiving all the available devices. Patients had a median age of 82 years (78-85) with no differences among time periods. A stepwise reduction of median Society of Thoracic Surgeons mortality risk score (3.7 [2.8-5.3] vs 3.6 [2.6-5.4] vs 3.6 [2.5-5.5] vs 3.3 [2.2-4.9]; p=0.01) was observed. In-hospital all-cause-death (7.5% vs 5.1% vs 2.9% vs 3.0%; p<0.05), major stroke (4.7% vs 0.7% vs 1.0% vs 0.8%; p<0.05), major vascular complications (17.8% vs 8.7% vs 10.5% vs 5.8%; p<0.05) and permanent pacemaker implantation (23.4% vs 12.0% vs 8.7% vs 8.8%; p<0.05) rates significantly lowered over time. Device success markedly improved (80.4% vs 87.1% vs 95.0% vs 96.3%; p<0.05) with significant improvement of paravalvular regurgitation after TAVI (moderate-to-severe 16.8% vs 8.1% vs 0.7% vs 0.2%; mild 61.4% vs 38.2% vs 38.5% vs 25.6%; p<0.05). CONCLUSIONS: All-cause death and in-hospital outcomes of patients undergoing TAVI significantly improved accordingly to technical advancements and changes in clinical practice over 15-year experience.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Int J Cardiol ; 352: 190-194, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35077726

RESUMO

BACKGROUND: The coronavirus 2019 (COVID-19) pandemic upset healthcare systems and their logistics worldwide. We sought to assess safety and effectiveness of an optimized logistics for transcatheter aortic valve implantation (TAVI) pathway developed during the COVID-19 pandemic. METHODS: This is a retrospective analysis. An optimized TAVI logistics based on performing TAVI work-up and procedure during the same hospitalization was used during the COVID-19 pandemic. In-hospital and 30-day outcomes of patients treated during the pandemic were compared with an historical cohort of patients undergoing TAVI with staged work-up before the pandemic within an homogeneous timeframe. RESULTS: Of 536 patients, 227 (42.4%) underwent TAVI during the COVID-19 pandemic with a reduction of 26.5% compared to the pre-pandemic period (n = 309). The median age was 81 (77-85) years and STS score was 3.4 (2.2-5.6)%. Lower rates of in-hospital major vascular complications (2.2% vs. 8.7%; p < 0.01) and life-threatening bleeding (0.4% vs. 4.2%; p = 0.01) were reported in the COVID-19 period, whereas no difference in acute kidney injury (7.0% vs. 7.4%, p = 0.85) rate was reported between COVID-19 and pre-COVID-19 periods. No difference in 30-day rates of all-cause death (4.0 vs. 4.5, p = 0.75) and of major adverse cardiovascular events (4.0 vs. 6.1, p = 0.26) were reported between COVID-19 and pre-COVID-19 periods. CONCLUSIONS: The use of optimized single-hospitalization logistics for TAVI workup and procedure developed during the COVID-19 pandemic, showed to be as safe and effective as the two-stage TAVI pathway previously adopted, allowing the minimization of potential exposure to COVID-19 infection and shortening times to treatment for severely symptomatic patients.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , COVID-19/epidemiologia , Atenção à Saúde , Humanos , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
3.
J Cardiovasc Echogr ; 32(3): 168-171, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36619783

RESUMO

We present the case of a 69-year-old man with an aortic biological prosthetic valve. In May 2019, the patient experienced increasing dyspnea and fatigue: A diagnosis of prosthetic aortic valve dysfunction was made, leading to severe valvular insufficiency. The dysfunction of the prosthetic valve seemed to be linked to a previous infective endocarditis: after ruling out active endocarditis, the patient was treated with an off-label valve-in-valve transcatheter aortic valve implantation.

4.
J Clin Med ; 10(16)2021 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-34441762

RESUMO

BACKGROUND: Cardiology divisions reshaped their activities during the coronavirus disease 2019 (COVID-19) pandemic. This study aimed to analyze the organization of echocardiographic laboratories and echocardiography practice during the second wave of the COVID-19 pandemic in Italy, and the expectations for the post-COVID era. METHODS: We analyzed two different time periods: the month of November during the second wave of the COVID-19 pandemic (2020) and the identical month during 2019 (November 2019). RESULTS: During the second wave of the COVID-19 pandemic, the hospital activity was partially reduced in 42 (60%) and wholly interrupted in 3 (4%) echocardiographic laboratories, whereas outpatient echocardiographic activity was partially reduced in 41 (59%) and completely interrupted in 7 (10%) laboratories. We observed an important change in the organization of activities in the echocardiography laboratory which reduced the operator-risk and improved self-protection of operators by using appropriate personal protection equipment. Operators wore FFP2 in 58 centers (83%) during trans-thoracic echocardiography (TTE), in 65 centers (93%) during transesophageal echocardiography (TEE) and 63 centers (90%) during stress echocardiography. The second wave caused a significant reduction in number of echocardiographic exams, compared to November 2019 (from 513 ± 539 to 341 ± 299 exams per center, -34%, p < 0.001). On average, there was a significant increase in the outpatient waiting list for elective echocardiographic exams (from 32.0 ± 28.1 to 45.5 ± 44.9 days, +41%, p < 0.001), with a reduction of in-hospital waiting list (2.9 ± 2.4 to 2.4 ± 2.0 days, -17%, p < 0.001). We observed a large diffusion of point-of-care cardiac ultrasound (88%), with a significant increase of lung ultrasound usage in 30 centers (43%) during 2019, extended to all centers in 2020. Carbon dioxide production by examination is an indicator of the environmental impact of technology (100-fold less with echocardiography compared to other cardiac imaging techniques). It was ignored in 2019 by 100% of centers, and currently it is considered potentially crucial for decision-making in cardiac imaging by 65 centers (93%). CONCLUSIONS: In one year, major changes occurred in echocardiography practice and culture. The examination structure changed with extensive usage of point-of-care cardiac ultrasound and with lung ultrasound embedded by default in the TTE examination, as well as the COVID-19 testing.

5.
EuroIntervention ; 17(9): 728-735, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33589411

RESUMO

BACKGROUND: Vascular complications still represent an important issue after transcatheter aortic valve implantation (TAVI). AIMS: The aim of this study was to evaluate the effectiveness of upfront use of an adjunctive Angio-Seal (AS) plug-based system on top of suture-based devices (SBDs) for endovascular haemostasis after transfemoral (TF) TAVI. METHODS: From January 2019 to April 2020, 332 consecutive patients with preprocedural computed tomography angiography (CTA) assessment underwent fully percutaneous TF-TAVI. The primary outcomes were 30-day major vascular complications and major or life-threatening (LT) bleeding due to endovascular closure system failure. A total of 246 TF-TAVI patients (123 pairs), undergoing either isolated SBD or SBD+AS, were matched using the propensity-score method. RESULTS: At 30 days, patients receiving SBD+AS had lower rates of major/LT bleeding (1.6% vs 8.9%, odds ratio [OR] 0.17, 95% confidence interval [CI]: 0.04-0.78; p<0.01) and major vascular complications (1.6% vs 8.9%, OR 0.17, 95% CI: 0.04-0.78; p<0.01). In addition, the use of SBD+AS was associated with a significant cost saving related to the vascular event (mean difference -315.3 € per patient, 95% CI: -566.4 € to -64.1 €; p=0.01), and a higher probability of next-day discharge (NDD) after TAVI (30.9% vs 16.3%, OR 2.30, 95% CI: 1.25-4.25; p<0.01). No difference in all-cause 30-day mortality was observed (3.3% vs 1.6% for SBD and SBD+AS groups, respectively, OR 0.49, 95% CI: 0.09-2.74; p=0.41). CONCLUSIONS: An upfront combined strategy with an additional AS plug-based device on top of SBDs was shown to reduce major vascular complications and major/LT bleeding due to closure system failure after TF-TAVI. This approach was associated with a cost saving and with a higher probability of NDD compared to the use of isolated SBD. Visual summary. Effectiveness of the upfront combined strategy for endovascular haemostasis in transfemoral transcatheter aortic valve implantation using Angio-Seal on top of a suture-based device (SBD) versus the isolated use of SBD. LT: life-threatening; TF-TAVI: transfemoral transcatheter aortic valve implantation.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemostasia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
JACC Cardiovasc Interv ; 13(21): 2542-2555, 2020 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-33069648

RESUMO

OBJECTIVES: The aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment. BACKGROUND: Certain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking. METHODS: RE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR. RESULTS: Among 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV-sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01). CONCLUSIONS: Unsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV-sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent [RE-ACCESS]; NCT04026204).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cateterismo , Humanos , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Risco , Resultado do Tratamento
7.
EuroIntervention ; 16(6): e494-e501, 2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32091404

RESUMO

AIMS: The aim of this study was to evaluate predictors and safety of next-day discharge (NDD) after transfemoral transcatheter aortic valve implantation (TF-TAVI) in unselected patients receiving either balloon-expandable or self-expanding devices. METHODS AND RESULTS: From June 2007 to August 2018, 1,232 consecutive patients undergoing TF-TAVI were discharged alive from our institution. They had a mean age of 80.9±5.4 years and an intermediate estimated surgical mortality risk; they received either balloon-expandable (26.1%) or self-expanding prostheses (73.9%). We compared patients discharged within 24 hours from the procedure (n=160, 13.0%) with those discharged later, and accounted for confounding variables through a propensity matching adjustment. After adjustment, no differences in all-cause mortality (1.2% vs 0.0%, for NDD and no-NDD matched groups, respectively, p=0.16) or permanent pacemaker implantation (PPI) after TAVI (0.6% vs 0.6%, respectively) were encountered at 30 days. At one year, no difference in the composite endpoint of all-cause death and heart failure (HF) rehospitalisation was encountered (Kaplan-Meier [KM] estimates 91.9% vs 90.6% for NDD and no-NDD matched groups, respectively, p=0.69). After excluding patients with post-procedural major complications from the unmatched population, prior PPI (OR 2.06, 95% CI: 1.21-3.51; p<0.01) and availability of preprocedural computed tomography angiography (CTA) (OR 1.71, 95% CI: 1.15-2.54; p<0.01) were found to be predictors of NDD after TAVI. CONCLUSIONS: NDD in unselected patients after TF-TAVI using either balloon-expandable or self-expanding devices was demonstrated to be a safe strategy up to one year in the absence of procedural complications. Patients with prior PPI and undergoing preprocedural CTA had a higher chance of NDD.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Alta do Paciente/normas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Feminino , Humanos , Tempo de Internação , Masculino , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
8.
J Cardiovasc Echogr ; 30(3): 154-161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33447506

RESUMO

BACKGROUND: According to the actual guidelines regarding severe aortic valve stenosis (AS), symptoms are the most important trigger for aortic valve replacement (AVR). However, the objective analysis of cardiological clinic can be confused, considering the aging population this disease affects and the comorbidities. OBJECTIVES: Looking for an objective marker of disease, useful for scheduling the correct AVR, we researched the relation between some biochemical markers of left ventricular (LV) dysfunction and its global longitudinal strain. MATERIALS AND METHODS: We analyzed 74 consecutive patients (82 ± 4 years) with severe AS. We identified 61 patients with symptoms (angina, dyspnea, and syncope) and 13 asymptomatic patients. The clinical and echocardiographic parameters were compared between these two groups. LV ejection fraction (LVEF), LV global longitudinal strain (LVGLS), NT-pro-B-type brain natriuretic peptide (BNP), troponin T (TNT), creatine kinase-MB (CPK-MB), and myoglobin were determined at the time of evaluation. RESULTS: Compared with the asymptomatic group, patients in the symptomatic group had a lower LVGLS (P = 0.002) and an increased pro-BNP (P = 0.0002). LVGLS showed a good correlation with pro-BNP as a marker of myocardial damage, with a linear increase of pro-BNP in patients with a linear decrease of LVGLS (r = 0.43). Despite the normal value of LVEF > 50% in asymptomatic patients, some of them (46%) have an early dysfunction of LVGLS. No other statistically significant difference emerged from the biochemical analysis, in TNT (P = 0.29), CPK-MB (P = 0.36), and myoglobin (P = 0.38). CONCLUSIONS: Pro-BNP and LVGLS can be considered an objective marker of clinical severity of AS disease, useful for management and scheduling of AVR, especially in asymptomatic patients.

9.
J Cardiovasc Echogr ; 28(3): 166-170, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30306020

RESUMO

BACKGROUND: A lot of studies have shown a positive effect of transcatheter aortic valve implantation (TAVI) on left ventricular ejection fraction (LVEF). OBJECTIVES: We aimed to investigate the effect of TAVI on left ventricular function and correlate this phenomenon with hypertrophy degree in an early follow-up. MATERIALS AND METHODS: Between August 2015 and July 2016, 250 consecutive patients with symptomatic severe aortic stenosis (AS) underwent TAVI in our institution. Given the aim of this analysis, only patients with an LVEF <50%, no more than moderate mitral valve regurgitation, successful valve implantation, and 1-month follow-up available were included in the study (n = 46). Patients were enrolled in a prospective database, with clinical and echocardiographic evaluations at 1 month after TAVI. RESULTS: All patients had severe symptomatic AS (mean transaortic pressure gradients: 44.1 ± 13.8 mmHg and mean aortic valve area: 0.66 ± 0.19 cm2). Mean baseline LVEF was 39.3 ± 8.8%. Significant hemodynamic improvement was observed after TAVI. Mean transvalvular aortic gradient decreased significantly from 44.1 ± 13.8 mmHg to 8.9 ± 4.2 mmHg (P < 0.005). A statistically significant improvement in LVEF compared to baseline was observed in the 1st month of follow-up (39.3 ± 8.8% vs. 44.1 ± 10.1%, P < 0.019). Overall, 52.2% of patients showed an increase in LVEF, 32.6% had no change, while only 2.2% had a decrease in LVEF. Interestingly, we found a significant reverse correlation between LVEF improvement and ventricular hypertrophy measured as diastolic interventricular septum thickness (Pearson index r = -0.42). Patients showing greater improvement in LVEF were those with less than moderate hypertrophy. CONCLUSIONS: Patients with depressed systolic function show a consistent and early LVEF recovery after TAVI. An impaired LVEF recovery is most likely among patients with more than moderate hypertrophy, probably responsible of left ventricular fibrosis that irremediably compromises systolic function.

10.
J Am Heart Assoc ; 7(15): e008440, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-30371244

RESUMO

Background Long-term data on durability of currently available transcatheter heart valves are sparse. We sought to assess the incidence of long-term (8-year) structural valve dysfunction and bioprosthetic valve failure in a cohort of patients with transcatheter aortic valve replacement ( TAVR ) who reached at least 5-year follow-up. Methods and Results Consecutive patients with at least 5-year follow-up available undergoing TAVR from June 4, 2007 to March 30, 2012 were included. Structural valve dysfunction and bioprosthetic valve failure were defined according to newly standardized European Association of Percutaneous Cardiovascular Interventions/ European Society of Cardiology/European Association for Cardio-Thoracic Surgery criteria and reported as cumulative incidence function to account for the competing risk of death. A total of 288 consecutive patients with a mean age of 80.7±5.3 years and with a mean Society of Thoracic Surgery mortality score of 8.1±5.1% were analyzed. Survival rate at 8 years was 29.8%. Mean pressure gradients decreased from 53.3±15.9 mm Hg (pre- TAVR ) to 10.5±4.5 mm Hg (in-hospital post- TAVR ) ( P<0.001). There was a small, not significant, increase in the transaortic gradient throughout follow-up. Bioprosthetic valve failure was observed in a total of 11 patients (8-year cumulative incidence function: 4.51%; 95% confidence interval , 1.95%-8.76%). Severe and moderate structural valve dysfunctions were reported in 7 patients (8-year cumulative incidence function: 2.39%; 95% confidence interval, 0.77%-5.71%) and 13 patients (8-year cumulative incidence function: 5.87%; 95% confidence interval , 3.06%-9.96%), respectively. Aortic valve reintervention (redo TAVR ) was successfully performed in 2 patients (0.7%) presenting with symptomatic severe restenosis and intraprosthetic regurgitation subsequent to endocarditis. Conclusions In an aged population of patients with symptomatic severe aortic stenosis treated with first-generation bioprostheses, TAVR was associated with a survival rate of 30% but low rates of bioprosthetic valve failure and structural valve dysfunction at 8 years.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Recidiva , Reoperação , Índice de Gravidade de Doença
11.
Circ Cardiovasc Interv ; 10(8)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28768757

RESUMO

BACKGROUND: We sought to describe an optimized approach to coronary artery disease (CAD) screening and management in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: When invasive coronary angiography showed CAD, the treatment strategy and completeness of revascularization was determined based on coronary anatomy. TAVR was performed in the same setting if percutaneous coronary intervention (PCI) was uncomplicated; otherwise TAVR was postponed. A total of 604 patients undergoing CAD screening at the time of TAVR procedure were prospectively included in this study. Severe CAD was found in 136 patients (22.5%). Among patients with severe CAD, 53 patients (8.8%) underwent uncomplicated PCI. After PCI, TAVR was postponed in 2 patients (0.3%). In 83 patients (13.8%), coronary angiography showed severe CAD that was left untreated. After TAVR, all-cause and cardiovascular 30-day mortality rates were 2.4% and 1.4%, respectively. Disabling stroke, myocardial infarction, and life-threatening bleeding occurred in 0.5%, 0.8%, and 4.0% of patients, respectively. Acute kidney injury II or III rate was 3.3%. At 2 years, all-cause mortality rate was 14.1%. Disabling stroke and myocardial infarction occurred in 2.5% and 1.8% of patients, respectively. Patients undergoing TAVR and PCI in the same session had similar rate of the composite of death, disabling stroke, and myocardial infarction when compared with patients without CAD, and patients with severe CAD left untreated (TAVR+PCI: 10.4%; severe CAD left untreated: 15.4%; no-CAD: 14.8%; P=0.765). CONCLUSIONS: In patients undergoing TAVR, screening of CAD with invasive coronary angiography and ad hoc PCI during TAVR is feasible and was not associated with increased periprocedural risks. PCI followed by TAVR in the same session had similar outcomes than TAVR in which PCI was not performed.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico , Programas de Rastreamento/estatística & dados numéricos , Intervenção Coronária Percutânea/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino
12.
EuroIntervention ; 12(8): e1031-e1038, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-26485733

RESUMO

AIMS: Long-term data on the durability of currently available transcatheter heart valves are limited. We sought to assess four-year clinical and echocardiographic outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis. METHODS AND RESULTS: Between June 2007 and February 2014, 450 consecutive patients with symptomatic severe aortic stenosis underwent TAVI in our institution. For the purposes of this study, we included only those patients undergoing successful TAVI with the CoreValve prosthesis who had a minimum follow-up of four years (n=125). Survival rates at one, two, three and four years were 83.2, 76.8, 73.6 and 66.3%, respectively. Aortic regurgitation was a common finding after the procedure, especially due to paravalvular regurgitation (PVR), which was observed in the majority of patients (71.5%), mostly mild (52.0%). Progression from mild acute PVR to moderate PVR at four-year follow-up was reported in three patients. No cases of severe PVR were observed. Prosthetic valve failure was reported in four patients (3.2%). CONCLUSIONS: Our study demonstrates that favourable outcomes after successful TAVI are associated with sustained clinical and functional cardiovascular benefits up to four-year follow-up. Signs of moderate prosthetic valve failure are present only in a small percentage of patients.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Falha de Prótese , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento
13.
Heart Vessels ; 31(3): 427-33, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25573258

RESUMO

The aim of this study was to compare the immediate outcome of patients undergoing transcatheter (TAVI) versus surgical aortic valve replacement with the sutureless Perceval bioprosthesis (SU-AVR). This is a retrospective multicenter analysis of 773 patients who underwent either TAVI (394 patients, mean age, 80.8 ± 5.5 years, mean EuroSCORE II 5.6 ± 4.9 %) or SU-AVR (379 patients, 77.4 ± 5.4 years, mean EuroSCORE II 4.0 ± 3.9 %) with or without concomitant myocardial revascularization. Data on SU-AVRs were provided by six European institutions (Belgium, Finland, Germany, Italy and Sweden) and data on TAVIs were provided by a single institution (Catania, Italy). In-hospital mortality was 2.6 % after SU-AVR and 5.3 % after TAVI (p = 0.057). TAVI was associated with a significantly high rate of mild (44.0 vs. 2.1 %) and moderate-severe paravalvular regurgitation (14.1 vs. 0.3 %, p < 0.0001) as well as the need for permanent pacemaker implantation (17.3 vs. 9.8 %, p = 0.003) compared with SU-AVR. The analysis of patients within the 25th and 75th percentiles interval of EuroSCORE II, i.e., 2.1-5.8 %, confirmed the findings of the overall series. One-to-one propensity score-matched analysis resulted in 144 pairs with similar baseline characteristics and operative risk. Among these matched pairs, in-hospital mortality (6.9 vs. 1.4 %, p = 0.035) was significantly higher after TAVI. SU-AVR with the Perceval prosthesis in intermediate-risk patients is associated with excellent immediate survival and is a valid alternative to TAVI in these patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos sem Sutura , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Europa (Continente) , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Pontuação de Propensão , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
Eur J Cardiothorac Surg ; 49(1): 220-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25653252

RESUMO

OBJECTIVES: The aim of this study was to analyse early postoperative outcomes and 2-year survival after aortic valve replacement (AVR) through a ministernotomy with a sutureless bioprosthesis implantation compared with a full sternotomy with implantation of a stented bioprosthesis. METHODS: Patients who underwent primary isolated non-emergent AVR at six European centres were included in the study. Of these, 182 (32%) underwent a ministernotomy with a sutureless bioprosthesis (ministernotomy sutureless group) and 383 (68%) a full sternotomy with a stented bioprosthesis (full sternotomy stented group). Propensity score matching was used to reduce selection bias. RESULTS: In the overall cohort, 30-day mortality was 1.6 and 2.1%, and 2-year survival was 92 and 92% in the ministernotomy sutureless group and in the full sternotomy stented group, respectively. Propensity score matching resulted in 171 pairs with similar characteristics and operative risk. Aortic cross-clamp (40 vs 65 min, P < 0.001) and cardiopulmonary bypass time (69 vs 87 min, P < 0.001) were shorter in the ministernotomy sutureless group. Patients undergoing ministernotomy received less packed red blood cells but the risk for postoperative permanent pacemaker implantation was higher. There were no differences regarding 30-day mortality or 2-year survival between the two groups. CONCLUSIONS: AVR through a ministernotomy with implantation of a sutureless bioprosthesis was associated with shorter aortic cross-clamp and cardiopulmonary bypass time and less transfusion of packed red blood cells, but a higher risk for postoperative permanent pacemaker implantation compared with a full sternotomy with a stented bioprosthesis.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Esternotomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Avaliação de Resultados em Cuidados de Saúde , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Esternotomia/mortalidade , Análise de Sobrevida , Resultado do Tratamento
15.
Semin Thorac Cardiovasc Surg ; 27(3): 257-63, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26708365

RESUMO

Despite optimal hemodynamics at rest, the performance of the aortic valve under stress conditions long after David I procedure is still debated. From 2001-2014, 73 patients underwent reimplantation with David I technique. Aortic valve function of 13 patients (age 61.2 ± 8.72) with a follow-up of at least 5 years (6.3 ± 0.9 years) was assessed at exercise echocardiographic stress test on a stationary cycle. Patients who had undergone concomitant procedure, with recurrent aortic insufficiency or mitral valve incompetence, were excluded. In all, 8 healthy volunteers served as controls. Transvalvular gradients progressively increased during the steps in both groups (P-within < 0.001), being higher in David patients (P-between < 0.001), but never reaching a clinical significance (David Peak gradient 23.8 ± 9.3 mmHg; Mean gradient 13.2 ± 5.1 mmHg). Effective orifice area (EOA) and EOA index did not change during the test in David patients, whereas Controls showed a progressive increase of functional valve area to a peak at 50 W (Controls EOA 4.0 ± 0.5 cm(2); EOA index 2.0 ± 0.3 cm(2)/m(2)). In conclusion, David I procedure ensures good hemodynamics during high-flow conditions at long-term follow-up. The reimplantation of the functional aortic annulus inside a rigid tube determines a paradoxical reduction of functional aortic valve area, secondary to the increased stroke volume, without any clinically relevant increase in transvalvular gradients. These data confirm the reliability of David I in the long term, even under physical stress conditions.


Assuntos
Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia sob Estresse/métodos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica/fisiologia , Procedimentos Cirúrgicos Vasculares/métodos , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
EuroIntervention ; 11(6): 690-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26499222

RESUMO

AIMS: The aim of this study was to compare outcomes with the use of two haemostasis strategies after transfemoral transcatheter aortic valve implantation (TAVI) - one Prostar® vs. two ProGlide® devices (Abbott Vascular Inc., Santa Clara, CA, USA). METHODS AND RESULTS: This was a retrospective study enrolling consecutive patients undergoing fully percutaneous transfemoral TAVI in our centre (Ferrarotto Hospital, Catania, Italy) from January 2012 to October 2014. All patients were dichotomised according to the vascular closure device (VCD) used for common femoral artery haemostasis (Prostar vs. ProGlide). All outcomes were defined according to VARC-2 criteria. The study population encompassed a total of 278 patients. Of these, 153 (55.1%) underwent TAVI using the Prostar, and 125 (44.9%) using two ProGlide devices. Vascular complications occurred in 48 patients (17.3%), being more frequent in the ProGlide group (11.8% vs. 24.0%, p=0.007). Patients who had TAVI using the ProGlide were also more likely to have a higher rate of percutaneous closure device failure (4.6% vs. 12.8%, p=0.013). Percutaneous peripheral intervention was performed in 13.7% and 28.0% of Prostar and ProGlide cases, respectively (p=0.003). CONCLUSIONS: Patients undergoing transfemoral TAVI had significantly lower rates of vascular complications and percutaneous closure device failures when the Prostar was used compared with two ProGlide devices.


Assuntos
Valva Aórtica , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Artéria Femoral , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Técnicas de Sutura , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/etiologia , Humanos , Itália , Masculino , Análise Multivariada , Razão de Chances , Punções , Radiografia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 8(12): 1595-604, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26386766

RESUMO

OBJECTIVES: The purpose of this study was to investigate the effect of the RenalGuard System (PLC Medical Systems, Milford, Massachusetts) on prevention of acute kidney injury (AKI) in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR is associated with varying degrees of post-procedural AKI. The RenalGuard System is a dedicated device designed for contrast-induced AKI prevention. Whether this device is also effective in patients with severe aortic stenosis undergoing TAVR is unexplored. METHODS: The present is an investigator-driven, single-center, prospective, open-label, registry-based randomized study that used the TAVR institutional registry of the Ferrarotto Hospital in Catania, Italy, as the platform for randomization, data collection, and follow-up assessment. A total of 112 consecutive patients undergoing TAVR were randomly assigned to hydration with normal saline solution controlled by the RenalGuard system and furosemide (RenalGuard group) or normal saline solution (control group). The primary endpoint was the incidence of Valve Academic Research Consortium-defined AKI in the first 72 h after the procedure. RESULTS: The AKI rate was lower in the RenalGuard group than in the control group (n = 3 [5.4%] vs. n =14 [25.0%], respectively, p = 0.014). The majority of patients (5.4% vs. 23.2%) developed a mild AKI (stage 1); severe damage (stage 3) occurred only in 1 patient in the control group (0.0% vs. 1.8%). No case of in-hospital renal failure requiring dialysis was reported. No significant differences in terms of mortality, cerebrovascular events, bleeding, and hospitalization for heart failure were noted in both groups at 30 days. CONCLUSIONS: Furosemide-induced diuresis with matched isotonic intravenous hydration using the RenalGuard system is an effective therapeutic tool to reduce the occurrence of AKI in patients undergoing TAVR.


Assuntos
Injúria Renal Aguda/prevenção & controle , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Meios de Contraste/efeitos adversos , Diurese/efeitos dos fármacos , Diuréticos/uso terapêutico , Hidratação/métodos , Furosemida/uso terapêutico , Implante de Prótese de Valva Cardíaca/métodos , Ácidos Tri-Iodobenzoicos/efeitos adversos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Feminino , Hidratação/efeitos adversos , Hidratação/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Infusões Intravenosas , Itália , Masculino , Estudos Prospectivos , Radiografia , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
18.
Heart ; 101(18): 1485-90, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26076940

RESUMO

BACKGROUND: The aim of this study was to assess the feasibility and the safety of early discharge (within 72 h) after transfemoral transcatheter aortic valve implantation (TAVI) and to identify baseline features and/or peri-procedural variables, which may affect post-TAVI length-of-stay (LoS) duration. METHODS AND RESULTS: Patients discharged within 72 h of TAVI (early discharge group) were compared with consecutive patients discharged after 3 days (late discharge group). Propensity-matched cohorts of patients with a 2:1 ratio were created to better control confounding bias. Among 465 patients, 107 (23.0%) were discharged within 3 days of the procedure. Multivariable regression analysis of unmatched patients demonstrated that baseline New York Heart Association (NYHA) class IV (OR: 0.22, 95% CI 0.05 to 0.96; p=0.045) and any bleeding (OR: 0.31, 95% CI 0.74 to 0.92; p=0.031) were less likely to be associated with early discharge after TAVI. Conversely, the year of procedure (OR: 1.66, 95% CI 1.25 to 2.20; p<0.001) and the presence of a permanent pacemaker (PPM) before TAVI (OR: 2.80, 95% CI 1.36 to 5.75; p=0.005) were associated with a higher probability of early discharge. In matched populations, patients in the early discharge group reported lower incidence of in-hospital bleeding (7.9% vs 19.4%, p=0.014), major vascular complications (2.3% vs 9.1%, p=0.038) and PPM implantation (7.9% vs18.5%, p=0.021), whereas after discharge, at 30-day, no significant differences were reported between groups in terms of death (2.2% vs 1.7%, p=0.540), bleeding (0.0% vs 1.1%, p=0.444), PPM implantation (1.1% vs 0.0%, p=0.333) and re-hospitalisation (1.1% vs 1.1%, p=1.000). CONCLUSIONS: Early discharge (within 72 h) after transfemoral TAVI is feasible and does not seem to jeopardise the early safety of the procedure, when performed in a subset of patients selected by clinical judgement. Patients undergoing TAVI in unstable haemodynamic compensation and patients experiencing bleeding after the procedure demonstrated to be poorly suitable to this approach, whereas increasing experience in post-TAVI management was associated with a reduction of LoS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Alta do Paciente/normas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Incidência , Tempo de Internação , Masculino , Avaliação de Resultados em Cuidados de Saúde , Marca-Passo Artificial/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Risco Ajustado , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
19.
Ann Thorac Surg ; 99(2): 524-30, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25483001

RESUMO

BACKGROUND: The aim of this study was to analyze early postoperative outcomes and 2-year survival after aortic valve replacement (AVR) with the sutureless Perceval bioprosthesis (Sorin Biomedica Cardio Srl, Salluggia, Italy) performed through ministernotomy compared with full sternotomy. METHODS: This was a study of 267 consecutive patients who underwent isolated AVR with the sutureless Perceval bioprosthesis between 2007 and 2014 at 6 European centers. Of these, 189 (70.8%) were performed through ministernotomy and 78 through a full sternotomy. Propensity score matching was used to reduce selection bias. RESULTS: In the overall cohort of ministernotomy and full sternotomy patients, in-hospital mortality was 1.1% and 2.6% and 2-year survival was 92% and 91%, respectively. Propensity score matching resulted in 56 pairs with similar characteristics and operative risk. Aortic cross-clamp (44 minutes in both groups, p = 0.931) and cardiopulmonary bypass time (69 vs 74 minutes, p = 0.363) did not differ between the groups. Apart from higher values in the ministernotomy group for postoperative peak gradients (28.1 vs 23.3 mm Hg, p = 0.026) and mean aortic valve gradients (15.2 vs 11.7 mm Hg, p = 0.011), early postoperative outcomes did not differ in the propensity-matched cohort. There were no differences in the in-hospital mortality rate or 2-year survival between the groups. CONCLUSIONS: AVR with the sutureless Perceval bioprosthesis through a ministernotomy was a safe and reproducible procedure that was not associated with prolonged aortic cross-clamp or cardiopulmonary bypass time compared with a full sternotomy. Early postoperative outcomes and 2-year survival were comparable between patients undergoing ministernotomy and full sternotomy.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Esternotomia/métodos , Idoso , Feminino , Humanos , Masculino , Desenho de Prótese , Suturas
20.
Heart Vessels ; 30(3): 386-95, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24820450

RESUMO

The hemodynamic load due to physical activity leads to structural and functional cardiac adaptations known as "Athlete's heart". We aimed to compare myocardial performance in different groups of trained athletes by means of 3D echocardiography and 3D speckle tracking echocardiography (3D-STE). 66 athletes [26 strength-trained athletes (STA) and 40 endurance athletes (ETA)] were prospectively enrolled. A control group of 40 sedentary subjects (sedentary group) was also included. All subjects underwent both standard and 3D evaluation of left ventricular (LV) function including 3D-STE. Left ventricular mass indexed for body surface area, LV end-diastolic (LV Dd) thickness of interventricular septum and posterior wall thickness mean values were significantly increased in athletes (p < 0.001, p < 0.01 and p < 0.001, respectively). LV diastolic diameter index had a significantly higher mean value in ETA in respect to sedentary group (p = 0.001). Despite a preserved mean value of LV ejection fraction (LV EF) in all the groups, subjects in STA group showed a significant reduction of strain in the longitudinal, radial and circumferential directions (p < 0.05 for all). Area strain mean value was also reduced in STA group (p < 0.01). In the overall population, an inverse relationship between longitudinal strain and LV Dd index (r = -0.260, p = 0.008), the E/A ratio (r = -0.249, p = 0.010) and the E' velocity (r = -0.259, p = 0.009) has been identified. Sport-specific patterns of ventricular morphological and functional remodeling are present in athletes performing different kinds of training. 3D-STE is a useful and feasible echocardiographic technique for the assessment of sport-specific pattern of deformational adaptations.


Assuntos
Atletas , Cardiomegalia Induzida por Exercícios , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica , Resistência Física , Função Ventricular Esquerda , Remodelação Ventricular , Adaptação Fisiológica , Adulto , Ciclismo , Fenômenos Biomecânicos , Estudos de Casos e Controles , Estudos Transversais , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Natação , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...