RESUMO

BACKGROUND: Left atrial appendage (LAA) occlusion has been established as an alternative to systemic anticoagulation for stroke prevention in patients with atrial fibrillation; however, limitations of current devices have slowed adoption. We present preclinical evaluations of a novel device, the Conformal Left Atrial Appendage Seal (CLAAS). METHODS: An in vitro assessment of conformability was conducted to evaluate the two CLAAS devices (regular 27 mm and large 35 mm) and a Watchman 2.5 (27 mm). Devices were placed within silicone tubes and compressed in a vise submerged in a water bath at 37°C. Changes in device diameter and visual seal were noted. Acute (n = 1) and chronic 60-day (n = 6) canine studies with gross and histologic assessment were performed. RESULTS: Conformability bench tests demonstrated that the regular CLAAS implant was able to seal oval orifices from 20 × 30 mm to 15 × 33 mm and the large from 30 × 35 mm to 20 × 40 mm. As the CLAAS implant was compressed in the minor diameter, it increased in the major diameter, thereby filling the oval space, whereas the Watchman 2.5 showed gaps and maintained its round configuration when compressed in one direction. Seven devices were successfully implanted in the canine model with complete seal without thrombus. Histologic examination showed complete neointima covering with minimal inflammation at 60 days. CONCLUSIONS: Preclinical testing demonstrated the conformability of the CLAAS implant and its ability to seal the LAA. Clinical studies are ongoing to characterize the utility of the CLAAS implant in the treatment of patients with atrial fibrillation.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Dispositivo para Oclusão Septal , Animais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cães , Ecocardiografia , Desenho de Equipamento , Inflamação , Masculino , Neointima , Desenho de Prótese , Silicones , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
2.
Expert Rev Med Devices ; 4(6): 781-92, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18035944

RESUMO

Thousands of patients have had congenital defects of their intra-atrial septa successfully closed via percutaneous techniques in the cardiac catheterization laboratory for hemodynamic correction, stroke, migraine and decompression illness. However, currently available closure technologies leave a permanent cardiac implant in a relatively young patient population. As the first device incorporating a bioabsorbable material for the treatment of structural heart disease, BioSTAR is uniquely designed to remodel into native tissue following closure, providing a more natural method of defect repair. This paper reviews atrial morphology, with a focus on patent foramen ovale, indications both present and emerging, and the development of technologies that promote a healthy natural healing response, with a focus on the design, testing and clinical experience with BioSTAR.


Assuntos
Implantes Absorvíveis , Defeitos dos Septos Cardíacos/terapia , Cicatrização , Ensaios Clínicos como Assunto , Forame Oval Patente , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...