Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38882716

RESUMO

During a radiological or nuclear emergency, occupational workers, members of the public, and emergency responders may be exposed to radionuclides, whether external or internal, through inhalation, ingestion, or wounds. In the case of internalized radiation exposure, prompt assessment of contamination is necessary to inform subsequent medical interventions. This review assembles the constituent considerations for managing nuclear and radiological incidents, focused on a parallel analysis of the evolution of radiation dose limits - notably in the emergency preparedness and response realm - alongside a discussion of triage systems and in vivo radionuclide detection tools. The review maps the development of international and national standards and regulations concerning radiation dose limits, illuminating how past incidents and accumulated knowledge have informed present emergency preparedness and response practices, specifically for internalized radiation. Additionally, the objectives and levels of radiation triage systems are explored in-depth, along with a global survey of practices and protocols. Finally, this review also focuses on in vivo detection systems and their capacities for radionuclide identification, prioritizing internalized gamma-emitting isotopes due to their broader relevance. Collectively, this study comprehensively addresses the intricacies of triage management following radiation emergencies, emphasizing the imperative for enhanced standardization and continued research in this critical domain.

2.
Phys Med Biol ; 68(5)2023 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-36780697

RESUMO

Dosimetric calculations, whether for radiation protection or nuclear medicine applications, are greatly influenced by the use of computational models of humans, called anthropomorphic phantoms. As anatomical models of phantoms have evolved and expanded, thus has the need for quantifying differences among each of these representations that yield variations in organ dose coefficients, whether from external radiation sources or internal emitters. This work represents an extension of previous efforts to quantify the differences in organ positioning within the body between a stylized and voxel phantom series. Where prior work focused on the organ depth distribution vis-à-vis the surface of the phantom models, the work described here quantifies the intra-organ and inter-organ distributions through calculation of the mean chord lengths. The revised Oak Ridge National Laboratory stylized phantom series and the University of Florida/National Cancer Institute voxel phantom series including a newborn, 1-, 5-, 10- and 15 year old, and adult phantoms were compared. Organ distances in the stylized phantoms were computed using a ray-tracing technique available through Monte Carlo radiation transport simulations in MCNP6. Organ distances in the voxel phantom were found using phantom matrix manipulation. Quantification of differences in organ chord lengths between the phantom series displayed that the organs of the stylized phantom series are typically situated farther away from one another than within the voxel phantom series. The impact of this work was to characterize the intra-organ and inter-organ distributions to explain the variations in updated internal dose coefficient quantities (i.e. specific absorbed fractions) while providing relevant data defining the spatial and volumetric organ distributions in the phantoms for use in subsequent internal dosimetric computations, with prospective relevance to patient-specific individualized dosimetry, as well as informing machine learning definition of organs using these reference models.


Assuntos
Proteção Radiológica , Radiometria , Recém-Nascido , Adulto , Humanos , Criança , Adolescente , Estudos Prospectivos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador , Imagens de Fantasmas , Método de Monte Carlo , Doses de Radiação
3.
Radiat Prot Dosimetry ; 198(6): 311-324, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35437606

RESUMO

Updated effective dose rate and exposure rate coefficients for age-specific receptors representing members of the public were computed for external exposures from age-specific patients administered 131I to treat thyroid dysfunction for patient release evaluation. Coefficients were compared to the simplified point source method described by United States Nuclear Regulatory Commission Regulatory Guide (RG) 8.39, which does not consider age-specific parameters, morphometry or time-dependent 131I biodistribution. Monte Carlo age-specific phantom simulations were correlated with modified continuous voiding patient biokinetic models approximating age-specific dose and exposure rates as a function of time postadministration. Dose rates resulted in an overapproximation by a factor of ~3 from differentiated thyroid cancer patients (5% uptake) and by ~2 from hyperthyroid patients (80%) at 8 h postadministration compared to RG8.39. This study provides a paradigm where age-specific morphometry and biokinetic integration must be jointly considered when developing patient release guidelines for 131I and future radionuclide therapies.


Assuntos
Radioisótopos do Iodo , Fatores Etários , Humanos , Radioisótopos do Iodo/uso terapêutico , Doses de Radiação , Distribuição Tecidual , Estados Unidos
4.
Health Phys ; 119(2): 163-175, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31913861

RESUMO

In the event of a radiological incident, the release of fission products into the surrounding environment and the ensuing external contamination present a challenge for triage assessment by emergency response personnel. Reference exposure rate and skin dose rate calibration data for emergency response personnel are currently lacking for cases where receptors are externally contaminated with fission products. Simulations were conducted to compute reference exposure rate coefficients and skin dose rate coefficients from photon-emitting fission products of radiological concern. To accomplish this task, simplified mathematical skin phantoms were created using surface area and height specifications from International Commission on Radiological Protection Publication 89. Simulations were conducted using Monte Carlo radiation transport code using newborn, 1-y-old, 5-y-old, 10-y-old, 15-y-old, and adult phantoms for 22 photon-emitting radionuclides. Exposure rate coefficient data were employed in a case study simulating the radionuclide inventory for a 17 × 17 Westinghouse pressurized water reactor, following three burn-up cycles at 14,600 MWd per metric ton of uranium. The decay times following the final cycle represent the relative activity fractions over a period of 0.5-30 d. The resulting data can be used as calibration standards for triage efforts in emergency response protocols.


Assuntos
Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Adolescente , Adulto , Calibragem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Cinética , Masculino , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação , Proteção Radiológica/estatística & dados numéricos , Liberação Nociva de Radioativos , Medição de Risco , Pele
5.
Health Phys ; 118(6): 615-622, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31658163

RESUMO

Iodine-131 is commonly used in medical diagnosis and therapy for patients with hyperthyroidism or differentiated thyroid cancer. Following treatment, patients may recuperate in a hotel room to avoid exposing family members. The main purpose of this study was to estimate external effective dose rate coefficients to a hotel worker who handles potentially contaminated bed linens due to secretions from I patients as sweat or urine. The external dose rate estimates were derived using Monte Carlo radiation transport code and the phantom with movable arms and legs to model a housekeeper standing in an upright position holding a pile of bed linens. Simulations further integrated the body burden of time-dependent biokinetic metabolism of I in the patient's body, differentiating between biokinetic excretion models of hyperthyroid vs. cancer patients. Organ absorbed dose rate and effective dose rate coefficients were calculated for three scenarios of bed linen contamination and estimated out to 5 d postadministration and compared to past I patient contamination measurements.


Assuntos
Roupas de Cama, Mesa e Banho , Radioisótopos do Iodo , Exposição Ocupacional/análise , Doses de Radiação , Exposição à Radiação/análise , Humanos , Radiometria , Fatores de Tempo
6.
Radiat Environ Biophys ; 57(4): 375-393, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30167867

RESUMO

Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory's articulated stylized adult phantom, "Phantom wIth Moving Arms and Legs" (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10- 9 to 20 MeV for the ICRP Publication 116 external exposure geometries-antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.


Assuntos
Nêutrons , Imagens de Fantasmas , Postura , Doses de Radiação , Radiometria/instrumentação , Humanos , Padrões de Referência
8.
Radiat Environ Biophys ; 56(4): 453-462, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28840329

RESUMO

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.


Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Humanos , Imersão , Masculino , Exposição Ocupacional/normas , Imagens de Fantasmas , Padrões de Referência , Pele/efeitos da radiação
9.
Radiat Environ Biophys ; 56(3): 255-267, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28493137

RESUMO

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios.


Assuntos
Imagens de Fantasmas , Exposição à Radiação/análise , Radiometria/instrumentação , Poluentes Radioativos do Solo/análise , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido
10.
Radiat Prot Dosimetry ; 174(2): 275-286, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-27150517

RESUMO

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge (CRPK) has undertaken a number of calculations in support of a revision to the United States Environmental Protection Agency (US EPA) Federal Guidance Report on external exposure to radionuclides in air, water and soil (FGR 12). Age-specific mathematical phantom calculations were performed for the conditions of submersion in radioactive air and immersion in water. Dose rate coefficients were calculated for discrete photon and electron energies and folded with emissions from 1252 radionuclides using ICRP Publication 107 decay data to determine equivalent and effective dose rate coefficients. The coefficients calculated in this work compare favorably to those reported in FGR12 as well as by other authors that employed voxel phantoms for similar exposure scenarios.


Assuntos
Proteção Radiológica , Poluentes Radioativos , Ar , Humanos , Imagens de Fantasmas , Fótons , Doses de Radiação , Monitoramento de Radiação , Radioisótopos , Estados Unidos , Água
11.
Radiat Prot Dosimetry ; 172(4): 367-374, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26838066

RESUMO

As part of a broader effort to calculate effective dose rate coefficients for external exposure to photons and electrons emitted by radionuclides distributed in air, soil or water, age-specific stylized phantoms have been employed to determine dose coefficients relating dose rate to organs and tissues in the body. In this article, dose rate coefficients computed using the International Commission on Radiological Protection reference adult male voxel phantom are compared with values computed using the Oak Ridge National Laboratory adult male stylized phantom in an air submersion exposure geometry. Monte Carlo calculations for both phantoms were performed for monoenergetic source photons in the range of 30 keV to 5 MeV. These calculations largely result in differences under 10 % for photon energies above 50 keV, and it can be expected that both models show comparable results for the environmental sources of radionuclides.


Assuntos
Modelos Teóricos , Neoplasias/radioterapia , Imagens de Fantasmas , Fótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Ar , Algoritmos , Carga Corporal (Radioterapia) , Elétrons , Humanos , Masculino , Método de Monte Carlo , Órgãos em Risco , Proteção Radiológica , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
12.
Med Phys ; 42(4): 1851-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832075

RESUMO

PURPOSE: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ((131)I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered (131)I. METHODS: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with (131)I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the (131)I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient's bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of (131)I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after (131)I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ specific activities of (131)I in the thyroid, bladder, and combined remaining tissues were calculated as a function of time after administration. Exposures to members of the public were considered for (131)I patients with normal thyroid uptake (peak thyroid uptake of ∼27% of administered (131)I), differentiated thyroid cancer (DTC, 5% uptake), and hyperthyroidism (80% uptake). RESULTS: The scenario with the patient seated behind the member of the public yielded the highest dose rate estimate of seated public transportation exposure cases. The dose rate to the adjacent room guest was highest for the exposure scenario in which the hotel guest and patient are seated by a factor of ∼4 for the normal and differentiated thyroid cancer uptake cases and by a factor of ∼3 for the hyperthyroid case. CONCLUSIONS: It was determined that for all modeled cases, the DTC case yielded the lowest external dose rates, whereas the hyperthyroid case yielded the highest dose rates. In estimating external dose to members of the public from patients with (131)I therapy, consideration must be given to (patient- and case-specific) administered (131)I activities and duration of exposure for a more complete estimate. The method implemented here included a detailed calculation model, which provides a means to determine dose rate estimates for a range of scenarios. The method was demonstrated for variations of three scenarios, showing how dose rates are expected to vary with uptake, voiding pattern, and patient location.


Assuntos
Hipertireoidismo/radioterapia , Radioisótopos do Iodo/efeitos adversos , Radioisótopos do Iodo/uso terapêutico , Exposição à Radiação , Neoplasias da Glândula Tireoide/radioterapia , Cuidadores , Simulação por Computador , Humanos , Hipertireoidismo/metabolismo , Radioisótopos do Iodo/metabolismo , Modelos Biológicos , Método de Monte Carlo , Veículos Automotores , Casas de Saúde , Imagens de Fantasmas , Postura , Doses de Radiação , Glândula Tireoide/metabolismo , Glândula Tireoide/efeitos da radiação , Neoplasias da Glândula Tireoide/metabolismo , Fatores de Tempo , Bexiga Urinária/efeitos da radiação , Micção/efeitos da radiação
13.
Radiat Prot Dosimetry ; 155(3): 300-16, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23436621

RESUMO

The detonation of a radiological dispersion device may result in a situation where individuals inhale radioactive materials and require rapid assessment of internal contamination. The feasibility of using a 2×2-inch sodium-iodide detector to determine the committed effective dose to an individual following acute inhalation of gamma-emitting radionuclides was investigated. Experimental configurations of point sources with a polymethyl methacrylate slab phantom were used to validate Monte Carlo simulations. The validated detector model was used to simulate the responses for four detector positions on six different anthropomorphic phantoms. The nuclides examined included (241)Am, (60)Co, (137)Cs, (131)I and (192)Ir. Biokinetic modelling was employed to determine the distributed activity in the body as a function of post-inhalation time. The simulation and biokinetic data were used to determine time-dependent count-rate values at optimal detector locations on the body for each radionuclide corresponding to a target committed effective dose (E50) value of 250 mSv.


Assuntos
Poluentes Radioativos do Ar/análise , Exposição por Inalação/efeitos adversos , Método de Monte Carlo , Imagens de Fantasmas , Monitoramento de Radiação/instrumentação , Iodeto de Sódio/química , Contagem Corporal Total/instrumentação , Adulto , Antropometria , Criança , Simulação por Computador , Raios gama/efeitos adversos , Humanos , Polimetil Metacrilato/química , Doses de Radiação , Proteção Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA