1.
Environ Sci Pollut Res Int ; 28(19): 23958-23974, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33398734

RESUMO

Contaminants of emerging concern (CECs) are released daily into surface water, and their recalcitrant properties often require tertiary treatment. Electrochemical oxidation (EO) is often used as an alternative way to eliminate these compounds from water, although the literature barely addresses the neurotoxic effects of residual by-products. Therefore, this study investigated the performance of EO in the removal of five CECs (alprazolam, clonazepam, diazepam, lorazepam, and carbamazepine) and performed neurotoxicity evaluations of residual EO by-products in Wistar rat brain hippocampal slices. Platinum-coated titanium (Ti/Pt) and boron-doped diamond (BDD) electrodes were studied as anodes. Different current densities (13-75 A m-2), pH values (3-10), electrolyte dosages (NaCl), and matrix effects were assessed using municipal wastewater (MWW). The drugs were successfully degraded after 5 min of reaction for both the Ti/Pt and BDD electrodes when a current density of 75 A m-2 was applied. For Ti/Pt and BDD, neutral and acidic pH demonstrated better CEC removal performance, respectively. Compound degradation using MWW achieved 40% removal after 120 min for Ti/Pt and ranged between 33 and 52% for the BDD anode. For Ti/Pt, neurotoxicity studies using MWW indicated a decrease in reactive oxygen species (ROS) signals. However, when an artificial cerebrospinal fluid (ACSF) medium was reapplied, the signal recovered and increased to a value above the baseline, indicating that cells recovered part of their normal activity but remained in a different condition. For the BDD anode, the treated MWW did not cause significant ROS production variations, suggesting that he EO was effective in eliminating the toxicity of the treated solution.


Assuntos
Preparações Farmacêuticas , Poluentes Químicos da Água , Animais , Diamante , Eletrodos , Oxirredução , Ratos , Ratos Wistar , Águas Residuárias , Poluentes Químicos da Água/análise
2.
Environ Sci Pollut Res Int ; 26(32): 33281-33293, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31520394

RESUMO

The main goal of this study was to evaluate the removal of bromate from drinking water using a heterogeneous photocatalytic mili-photoreactor, based on NETmix technology. The NETmix mili-reactor consists of a network of channels and chambers imprinted in a back slab made of acrylic (AS) or stainless steel (SSS) sealed, through mechanical compression and o-rings, with an UVA-transparent front borosilicate glass slab (BGS). A plate of UVA-LEDs was placed above the BGS window. TiO2-P25 thin films were immobilized on the BGS (back-side illumination, BSI) or SSS (front-side illumination, FSI) by using a spray deposition method. The photoreduction rate of a 200 µg L-1 (1.56 µM) BrO3- solution was assessed taking into account the following: (i) catalyst film thickness, (ii) catalyst coated surface and illumination mechanism (BSI or FSI), (iii) solution pH, (iv) type and dose of sacrificial agent (SA), (v) reactor material, and (vi) water matrix. In acidic conditions (pH 3.0) and in the absence of light/catalyst/SA, 28% and 36% of BrO3- was reduced into Br- only by contacting with AS and SSS during 2-h, respectively. This effect prevailed during BSI experiments, but not for FSI ones since back SSS was coated with the photocatalyst. The results obtained have demonstrated that (i) the molar rate of disappearance of bromates was similar to the molar rate of formation of bromides; (ii) higher BrO3- reduction efficiencies were reached in the presence of an SA using the FSI at pH 3.0; (iii) formic acid ([BrO3-]:[CH2O2] molar ratio of 1:3) presented higher performance than humic acids (HA = 1 mg C L-1) as SA; (iv) high amounts of HA impaired the BrO3- photoreduction reaction; (v) SSS coated catalyst surface revealed to be stable for at least 4 consecutive cycles, keeping its photonic efficiency. Under the best operating conditions (FSI, 18 mL of 2% wt. TiO2-P25 suspension, pH 3.0), the use of freshwater matrices led to (i) equal or higher reaction rates, when compared with a synthetic water in the absence of SA, and (ii) lower reaction rates, when compared with a synthetic water containing formic acid with a [BrO3-]:[CH2O2] molar ratio of 1:3. Notwithstanding, heterogeneous TiO2 photocatalysis, using the NETmix mili-reactor can be used to promote the reduction of BrO3- into Br-, attaining concentrations below 10 µg L-1 (guideline value) after 2-h reaction. Graphical Abstract .


Assuntos
Bromatos/análise , Poluentes Químicos da Água/análise , Purificação da Água/métodos , Bromatos/química , Brometos , Catálise , Água Potável , Poluentes Químicos da Água/química
3.
Waste Manag ; 89: 114-128, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-31079725

RESUMO

This study aimed at developing an efficient multistage treatment strategy for a complex industrial landfill leachate: a leather tannery landfill leachate. Based on the leachate physicochemical characteristics, the following treatment train was delineated and tested: (i) initial biological process for removal of biodegradable organics, ammonium and alkalinity, (ii) coagulation/flocculation process for total removal of chromium and partial removal of recalcitrant organics and suspended solids, (iii) advanced oxidation process (AOP) or electrochemical AOP (EAOP) for degradation of recalcitrant organics and biodegradability enhancement, and (iv) final biological polishing step. Two initial biological treatment configurations were applied: one comprising nitrification and the other nitrification-denitrification. Coagulation/flocculation was optimized in terms of pH, coagulant dosage (iron(III) chloride) and flocculant nature and dosage. The following AOPs/EAOPs were tested: Fenton, photo-Fenton with UVA or UVC radiation (PF-UVA or PF-UVC), anodic oxidation (AO), electro-Fenton (EF) and photoelectro-Fenton with UVA radiation (PEF-UVA). The biological nitrification-denitrification was beneficial not only because it avoided the need for alkalinity addition during nitrification and decreased the amount of substrate added during denitrification, as expected. Over and above that, it reduced the acid consumption in the coagulation/flocculation, avoided the application of an additional stage comprising nitrites oxidation to nitrates prior to the AOP/EAOP, and improved the efficiency of Fenton's reaction based processes. Following nitrification-denitrification, the coagulation/flocculation was maximized at pH 3.0 and 400 mg Fe L-1 with no flocculant addition. The PEF-UVA process was the best AOP/EAOP. The final leachate fulfilled the discharge limits into waterbodies.


Assuntos
Poluentes Químicos da Água , Desnitrificação , Compostos Férricos , Peróxido de Hidrogênio , Ferro , Nitrificação , Oxirredução
4.
Environ Sci Pollut Res Int ; 24(7): 6195-6204, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26555882

RESUMO

The present study aims to assess the removal of 3-amino-5-methylisoxazole (AMI), a recalcitrant by-product resulting from the biological breakdown of some pharmaceuticals, applying a solar photo-Fenton process assisted by ferrioxalate complexes (SPFF) (Fe3+/H2O2/oxalic acid/UVA-Vis) and classical solar photo-Fenton process (SPF) (Fe2+/H2O2/UVA-Vis). The oxidation ability of SPFF was evaluated at different iron/oxalate molar ratios (1:3, 1:6, and 1:9, with [total iron] = 3.58 × 10-2 mM and [oxalic acid] = 1.07 × 10-1, 2.14 × 10-1 and 3.22 × 10-1 mM, respectively) and pH values (3.5-6.5), using low iron contents (2.0 mg Fe3+ L-1). Additionally, the use of other organic ligands such as citrate and ethylenediamine-N,N'-disuccinic acid (EDDS) was tested. The oxidation power of the classical SPF was assessed at different pH values (2.8-4.0) using 2.0 mg Fe2+ per liter. Furthermore, the effect of AMI concentration (2-20 mg L-1), presence of inorganic ions (Cl-, SO42-, NO3-, HCO3-, NH4+), and radical scavengers (sodium azide and D-mannitol) on the SPF method at pH 3.5 was also assessed. Experiments were done using a lab-scale photoreactor with a compound parabolic collector (CPC) under simulated solar radiation. A pilot-scale assay was conducted using the best operation conditions. While at near neutral pH, an iron/oxalate molar ratio of 1:9 led to the removal of 72 % of AMI after 90 min of SPFF, at pH 3.5, an iron/oxalate molar ratio of 1:3 was enough to achieve complete AMI degradation (below the detection limit) after 30 min of reaction. The SPF process at pH 3.5 underwent a slower AMI degradation, reaching total AMI degradation after 40 min of reaction. The scale up of SPF process showed a good reproducibility. Oxalic and oxamic acids were identified as the main low-molecular-weight carboxylic acids detected during the pilot-scale SPF reaction. Graphical abstract ᅟ.


Assuntos
Resíduos de Drogas/química , Peróxido de Hidrogênio/química , Ferro/química , Isoxazóis/química , Processos Fotoquímicos , Concentração de Íons de Hidrogênio , Ácido Oxálico/química , Oxirredução